Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 1/2010

01-01-2010 | Orthopaedic Surgery

Dutch orthopedic blood management surveys 2002 and 2007: an increasing use of blood-saving measures

Authors: Wieger Geert Horstmann, Harmen B. Ettema, Cees C. P. M. Verheyen

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 1/2010

Login to get access

Abstract

Background

Hip and knee arthroplasties are frequently complicated by the need for allogeneic blood transfusions. The surveys were developed to assess the use of blood-saving measures in orthopedic surgery in the Netherlands in 2002 and 2007.

Study design and methods

In 2002 and 2007, a questionnaire on blood management measures after several orthopedic procedures was sent to all Dutch orthopedic departments (110 and 96, respectively).

Results

The response was 79% in 2002 and 84% in 2007. The use of preoperative autologous blood donation remained virtually unchanged in 2002 versus 2007 for both hip (10.9 and 10.5%) and knee (5.7 and 8.2%) arthroplasty. In 2007, there was a substantial increase in departments using erythropoietine for hip (31.6–66.1%) as well as knee (24.0–55.5%) arthroplasty. There was an increase of the use of autologous retransfusion of intraoperatively suctioned washed blood in hip (20.3–28.4%) as well as knee arthroplasty (8.9–16.1%) over the 5-year period, but it was predominantly used in revision hip arthroplasty (54.3%). The use of postoperative autologous retransfusion of filtered drained wound blood increased dramatically in 5 years time in hip (11.5–51.0%) and knee arthroplasty (15.9–59.3%).

Conclusion

There is an evident increase in the preoperative use of erythropoietin and the postoperative use of autologous retransfusion of drained blood among Dutch orthopedic departments. There appears to be an increasing awareness and positive attitude among Dutch orthopedic surgeons to implement perioperative blood-saving measures.
Appendix
Available only for authorised users
Literature
3.
go back to reference Bierbaum BE, Callaghan JJ, Galante JO, Rubash HE, Tooms RE, Welch RB (1999) An analysis of blood management in patients having a total hip or knee arthroplasty. J Bone Joint Surg Am 81:2–10PubMed Bierbaum BE, Callaghan JJ, Galante JO, Rubash HE, Tooms RE, Welch RB (1999) An analysis of blood management in patients having a total hip or knee arthroplasty. J Bone Joint Surg Am 81:2–10PubMed
4.
go back to reference Salido JA, Marin LA, Gomez LA, Zorrilla P, Martinez C (2002) Preoperative hemoglobin levels and the need for transfusion after prosthetic hip and knee surgery: analysis of predictive factors. J Bone Joint Surg Am 84-A:216–220PubMed Salido JA, Marin LA, Gomez LA, Zorrilla P, Martinez C (2002) Preoperative hemoglobin levels and the need for transfusion after prosthetic hip and knee surgery: analysis of predictive factors. J Bone Joint Surg Am 84-A:216–220PubMed
5.
go back to reference Lemos MJ, Healy WL (1996) Blood transfusion in orthopedic operations. J Bone Joint Surg Am 78:1260–1270PubMed Lemos MJ, Healy WL (1996) Blood transfusion in orthopedic operations. J Bone Joint Surg Am 78:1260–1270PubMed
6.
go back to reference Keating EM, Meding JB (2002) Perioperative blood management practices in elective orthopedic surgery. J Am Acad Orthop Surg 10:393–400PubMed Keating EM, Meding JB (2002) Perioperative blood management practices in elective orthopedic surgery. J Am Acad Orthop Surg 10:393–400PubMed
10.
go back to reference Blumberg N (1997) Allogeneic transfusion and infection: economic and clinical implications. Semin Hematol 34:34–40PubMed Blumberg N (1997) Allogeneic transfusion and infection: economic and clinical implications. Semin Hematol 34:34–40PubMed
12.
go back to reference Innerhofer P, Klingler A, Klimmer C, Fries D, Nussbaumer W (2005) Risk for postoperative infection after transfusion of white blood cell-filtered allogeneic or autologous blood components in orthopedic patients undergoing primary arthroplasty. Transfusion 45:103–110. doi:10.1111/j.1537-2995.2005.04149.x CrossRefPubMed Innerhofer P, Klingler A, Klimmer C, Fries D, Nussbaumer W (2005) Risk for postoperative infection after transfusion of white blood cell-filtered allogeneic or autologous blood components in orthopedic patients undergoing primary arthroplasty. Transfusion 45:103–110. doi:10.​1111/​j.​1537-2995.​2005.​04149.​x CrossRefPubMed
15.
go back to reference Henry DA, Carless PA, Moxey AJ, O’Connell D, Forgie MA, Wells PS, Fergusson D (2002) Pre-operative autologous donation for minimising perioperative allogeneic blood transfusion. Cochrane Database Syst Rev 2:CD003602 Henry DA, Carless PA, Moxey AJ, O’Connell D, Forgie MA, Wells PS, Fergusson D (2002) Pre-operative autologous donation for minimising perioperative allogeneic blood transfusion. Cochrane Database Syst Rev 2:CD003602
16.
go back to reference Forgie MA, Wells PS, Laupacis A, Fergusson D (1998) Preoperative autologous donation decreases allogeneic transfusion but increases exposure to all red blood cell transfusion: results of a meta-analysis. International study of perioperative transfusion (ISPOT) Investigators. Arch Intern Med 158(6):610–616. doi:10.1001/archinte.158.6.610 CrossRefPubMed Forgie MA, Wells PS, Laupacis A, Fergusson D (1998) Preoperative autologous donation decreases allogeneic transfusion but increases exposure to all red blood cell transfusion: results of a meta-analysis. International study of perioperative transfusion (ISPOT) Investigators. Arch Intern Med 158(6):610–616. doi:10.​1001/​archinte.​158.​6.​610 CrossRefPubMed
17.
go back to reference Carless PA, Henry DA, Moxey AJ (2006) O’connell DL, Brown T, Fergusson DA. Cell salvage for minimising perioperative allogeneic blood transfusion. Cochrane Database Syst Rev 4:CD001888 Carless PA, Henry DA, Moxey AJ (2006) O’connell DL, Brown T, Fergusson DA. Cell salvage for minimising perioperative allogeneic blood transfusion. Cochrane Database Syst Rev 4:CD001888
18.
go back to reference Levy O, Martinowitz U, Oran A, Tauber C, Horoszowski H (1999) The use of fibrin tissue adhesive to reduce blood loss and the need for blood transfusion after total knee arthroplasty. A prospective, randomized, multicenter study. J Bone Joint Surg Am 81(11):1580–1588PubMed Levy O, Martinowitz U, Oran A, Tauber C, Horoszowski H (1999) The use of fibrin tissue adhesive to reduce blood loss and the need for blood transfusion after total knee arthroplasty. A prospective, randomized, multicenter study. J Bone Joint Surg Am 81(11):1580–1588PubMed
19.
go back to reference Molloy DO, Archbold HA, Ogonda L, McConway J, Wilson RK, Beverland DE (2007) Comparison of topical fibrin spray and tranexamic acid on blood loss after total knee replacement: a prospective, randomised controlled trial. J Bone Joint Surg Br 89(3):306–309. doi:10.1302/0301-620X.89B3.17565 CrossRefPubMed Molloy DO, Archbold HA, Ogonda L, McConway J, Wilson RK, Beverland DE (2007) Comparison of topical fibrin spray and tranexamic acid on blood loss after total knee replacement: a prospective, randomised controlled trial. J Bone Joint Surg Br 89(3):306–309. doi:10.​1302/​0301-620X.​89B3.​17565 CrossRefPubMed
20.
go back to reference Wang GJ, Hungerford DS, Savory CG, Rosenberg AG, Mont MA, Burks SG, Mayers SL, Spotnitz WD (2001) Use of fibrin sealant to reduce bloody drainage and haemoglobin loss after total knee arthroplasty. J Bone Joint Surg Am 83:1503–1505PubMed Wang GJ, Hungerford DS, Savory CG, Rosenberg AG, Mont MA, Burks SG, Mayers SL, Spotnitz WD (2001) Use of fibrin sealant to reduce bloody drainage and haemoglobin loss after total knee arthroplasty. J Bone Joint Surg Am 83:1503–1505PubMed
21.
go back to reference Carless PA, Henry DA, Anthony DM (2003) Fibrin sealant use for minimising peri-operative allogeneic blood transfusion. Cochrane Database Syst Rev 2:CD004171 Carless PA, Henry DA, Anthony DM (2003) Fibrin sealant use for minimising peri-operative allogeneic blood transfusion. Cochrane Database Syst Rev 2:CD004171
22.
go back to reference Lassen MR, Solgaard S, Kjersgaard AG, Olsen C, Lind B, Mittet K, Ganes HC (2006) A pilot study of the effects of Vivostat patient-derived fibrin sealant in reducing blood loss in primary hip arthroplasty. Clin Appl Thromb Hemost 12(3):352–357. doi:10.1177/1076029606291406 CrossRefPubMed Lassen MR, Solgaard S, Kjersgaard AG, Olsen C, Lind B, Mittet K, Ganes HC (2006) A pilot study of the effects of Vivostat patient-derived fibrin sealant in reducing blood loss in primary hip arthroplasty. Clin Appl Thromb Hemost 12(3):352–357. doi:10.​1177/​1076029606291406​ CrossRefPubMed
23.
go back to reference Everts PA, Overdevest EP, Jakimowicz JJ, Oosterbos CJ, Schönberger JP, Knape JT, van Zundert A (2007) The use of autologous platelet-leukocyte gels to enhance the healing process in surgery, a review. Surg Endosc 21(11):2063–2068. doi:10.1007/s00464-007-9293-x ReviewCrossRefPubMed Everts PA, Overdevest EP, Jakimowicz JJ, Oosterbos CJ, Schönberger JP, Knape JT, van Zundert A (2007) The use of autologous platelet-leukocyte gels to enhance the healing process in surgery, a review. Surg Endosc 21(11):2063–2068. doi:10.​1007/​s00464-007-9293-x ReviewCrossRefPubMed
24.
go back to reference Berghoff WJ, Pietrzak WS, Rhodes RD (2006) Platelet-rich plasma application during closure following total knee arthroplasty. Orthopedics 29(7):590–598PubMed Berghoff WJ, Pietrzak WS, Rhodes RD (2006) Platelet-rich plasma application during closure following total knee arthroplasty. Orthopedics 29(7):590–598PubMed
25.
go back to reference Gardner MJ, Demetrakopoulos D, Klepchick PR, Mooar PA (2007) The efficacy of autologous platelet gel in pain control and blood loss in total knee arthroplasty. An analysis of the haemoglobin, narcotic requirement and range of motion. Int Orthop 31(3):309–313. doi:10.1007/s00264-006-0174-z CrossRefPubMed Gardner MJ, Demetrakopoulos D, Klepchick PR, Mooar PA (2007) The efficacy of autologous platelet gel in pain control and blood loss in total knee arthroplasty. An analysis of the haemoglobin, narcotic requirement and range of motion. Int Orthop 31(3):309–313. doi:10.​1007/​s00264-006-0174-z CrossRefPubMed
26.
go back to reference Carless PA, Rubens FD, Anthony DM, O’Connell D, Henry DA (2003) Platelet-rich-plasmapheresis for minimising peri-operative allogeneic blood transfusion. Cochrane Database Syst Rev 2:CD004172 Carless PA, Rubens FD, Anthony DM, O’Connell D, Henry DA (2003) Platelet-rich-plasmapheresis for minimising peri-operative allogeneic blood transfusion. Cochrane Database Syst Rev 2:CD004172
30.
go back to reference Dramis A, Plewes J (2006) Autologous blood transfusion after primary unilateral total knee replacement surgery. Acta Orthop Belg 72(1):15–17PubMed Dramis A, Plewes J (2006) Autologous blood transfusion after primary unilateral total knee replacement surgery. Acta Orthop Belg 72(1):15–17PubMed
33.
go back to reference Henry DA, Carless PA, Moxey AJ, O’Connell D, Stokes BJ, McClelland B, Laupacis A, Fergusson D (2007) Anti-fibrinolytic use for minimising perioperative allogeneic blood transfusion. Cochrane Database Syst Rev 4:CD001886 Henry DA, Carless PA, Moxey AJ, O’Connell D, Stokes BJ, McClelland B, Laupacis A, Fergusson D (2007) Anti-fibrinolytic use for minimising perioperative allogeneic blood transfusion. Cochrane Database Syst Rev 4:CD001886
34.
go back to reference Weber EW, Slappendel R, Durieux ME, Dirksen R, van der Heide H, Spruit M (2003) COX 2 selectivity of non-steroidal anti-inflammatory drugs and perioperative blood loss in hip surgery. A randomized comparison of indomethacin and meloxicam. Eur J Anaesthesiol 20(12):963–966. doi:10.1097/00003643-200312000-00005 CrossRefPubMed Weber EW, Slappendel R, Durieux ME, Dirksen R, van der Heide H, Spruit M (2003) COX 2 selectivity of non-steroidal anti-inflammatory drugs and perioperative blood loss in hip surgery. A randomized comparison of indomethacin and meloxicam. Eur J Anaesthesiol 20(12):963–966. doi:10.​1097/​00003643-200312000-00005 CrossRefPubMed
35.
go back to reference Hill SR, Carless PA, Henry DA, Carson JL, Hebert PC, McClelland DB, Henderson KM (2002) Transfusion thresholds and other strategies for guiding allogeneic red blood cell transfusion. Cochrane Database Syst Rev 2:CD002042 Hill SR, Carless PA, Henry DA, Carson JL, Hebert PC, McClelland DB, Henderson KM (2002) Transfusion thresholds and other strategies for guiding allogeneic red blood cell transfusion. Cochrane Database Syst Rev 2:CD002042
36.
go back to reference Paul JE, Ling E, Lalonde C, Thabane L (2007) Deliberate hypotension in orthopedic surgery reduces blood loss and transfusion requirements: a meta-analysis of randomized controlled trials. Can J Anaesth 54(10):799–810CrossRefPubMed Paul JE, Ling E, Lalonde C, Thabane L (2007) Deliberate hypotension in orthopedic surgery reduces blood loss and transfusion requirements: a meta-analysis of randomized controlled trials. Can J Anaesth 54(10):799–810CrossRefPubMed
39.
go back to reference Karakaya D, Ustün E, Tür A, Bariş S, Sarihasan B, Sahinoğlu H, Güldoğuş F (1999) Acute normovolemic hemodilution and nitroglycerin-induced hypotension: comparative effects on tissue oxygenation and allogeneic blood transfusion requirement in total hip arthroplasty. J Clin Anesth 11(5):368–374. doi:10.1016/S0952-8180(99)00063-X CrossRefPubMed Karakaya D, Ustün E, Tür A, Bariş S, Sarihasan B, Sahinoğlu H, Güldoğuş F (1999) Acute normovolemic hemodilution and nitroglycerin-induced hypotension: comparative effects on tissue oxygenation and allogeneic blood transfusion requirement in total hip arthroplasty. J Clin Anesth 11(5):368–374. doi:10.​1016/​S0952-8180(99)00063-X CrossRefPubMed
40.
go back to reference Shapira Y, Gurman G, Artru AA, Ousyscher IE, Lam AM, Kollender Y, Meller I (1997) Combined hemodilution and hypotension monitored with jugular bulb oxygen saturation, EEG, and ECG decreases transfusion volume and length of ICU stay for major orthopedic surgery. J Clin Anesth 9(8):643–649. doi:10.1016/S0952-8180(97)00193-1 CrossRefPubMed Shapira Y, Gurman G, Artru AA, Ousyscher IE, Lam AM, Kollender Y, Meller I (1997) Combined hemodilution and hypotension monitored with jugular bulb oxygen saturation, EEG, and ECG decreases transfusion volume and length of ICU stay for major orthopedic surgery. J Clin Anesth 9(8):643–649. doi:10.​1016/​S0952-8180(97)00193-1 CrossRefPubMed
42.
go back to reference Winkler M, Akça O, Birkenberg B, Hetz H, Scheck T, Arkiliç CF, Kabon B, Marker E, Grübl A, Czepan R, Greher M, Goll V, Gottsauner-Wolf F, Kurz A, Sessler DI (2000) Aggressive warming reduces blood loss during hip arthroplasty. Anesth Analg 91(4):978–984. doi:10.1097/00000539-200010000-00039 CrossRefPubMed Winkler M, Akça O, Birkenberg B, Hetz H, Scheck T, Arkiliç CF, Kabon B, Marker E, Grübl A, Czepan R, Greher M, Goll V, Gottsauner-Wolf F, Kurz A, Sessler DI (2000) Aggressive warming reduces blood loss during hip arthroplasty. Anesth Analg 91(4):978–984. doi:10.​1097/​00000539-200010000-00039 CrossRefPubMed
47.
go back to reference Dauphin A, Raymer KE, Stanton EB, Fuller HD (1997) Comparison of general anesthesia with and without lumbar epidural for total hip arthroplasty: effects of epidural block on hip arthroplasty. J Clin Anesth 9(3):200–203. doi:10.1016/S0952-8180(97)00035-4 CrossRefPubMed Dauphin A, Raymer KE, Stanton EB, Fuller HD (1997) Comparison of general anesthesia with and without lumbar epidural for total hip arthroplasty: effects of epidural block on hip arthroplasty. J Clin Anesth 9(3):200–203. doi:10.​1016/​S0952-8180(97)00035-4 CrossRefPubMed
48.
go back to reference Rodgers A, Walker N, Schug S, McKee A, Kehlet H, van Zundert A, Sage D, Futter M, Saville G, Clark T, MacMahon S (2000) Reduction of postoperative mortality and morbidity with epidural or spinal anaesthesia: results from overview of randomised trials. BMJ 321(7275):1493–1497. doi:10.1136/bmj.321.7275.1493 ReviewCrossRefPubMed Rodgers A, Walker N, Schug S, McKee A, Kehlet H, van Zundert A, Sage D, Futter M, Saville G, Clark T, MacMahon S (2000) Reduction of postoperative mortality and morbidity with epidural or spinal anaesthesia: results from overview of randomised trials. BMJ 321(7275):1493–1497. doi:10.​1136/​bmj.​321.​7275.​1493 ReviewCrossRefPubMed
49.
go back to reference Freedman J, Luke K, Escobar M, Vernich L, Chiavetta JA (2008) Experience of a network of transfusion coordinators for blood conservation (Ontario Transfusion Coordinators [ONTraC]). Transfusion 48(2):237–250PubMed Freedman J, Luke K, Escobar M, Vernich L, Chiavetta JA (2008) Experience of a network of transfusion coordinators for blood conservation (Ontario Transfusion Coordinators [ONTraC]). Transfusion 48(2):237–250PubMed
50.
go back to reference Wong CJ, Vandervoort MK, Vandervoort SL, Donner A, Zou G, MacDonald JK, Freedman J, Karkouti K, MacDonald SJ, Feagan BG (2007) A cluster-randomized controlled trial of a blood conservation algorithm in patients undergoing total hip joint arthroplasty. Transfusion 47(5):832–841. doi:10.1111/j.1537-2995.2007.01197.x CrossRefPubMed Wong CJ, Vandervoort MK, Vandervoort SL, Donner A, Zou G, MacDonald JK, Freedman J, Karkouti K, MacDonald SJ, Feagan BG (2007) A cluster-randomized controlled trial of a blood conservation algorithm in patients undergoing total hip joint arthroplasty. Transfusion 47(5):832–841. doi:10.​1111/​j.​1537-2995.​2007.​01197.​x CrossRefPubMed
51.
go back to reference Pierson JL, Hannon TJ, Earles DR (2004) A blood-conservation algorithm to reduce blood transfusions after total hip and knee arthroplasty. J Bone Joint Surg Am 86-A(7):1512–1518PubMed Pierson JL, Hannon TJ, Earles DR (2004) A blood-conservation algorithm to reduce blood transfusions after total hip and knee arthroplasty. J Bone Joint Surg Am 86-A(7):1512–1518PubMed
52.
Metadata
Title
Dutch orthopedic blood management surveys 2002 and 2007: an increasing use of blood-saving measures
Authors
Wieger Geert Horstmann
Harmen B. Ettema
Cees C. P. M. Verheyen
Publication date
01-01-2010
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 1/2010
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-009-0910-0

Other articles of this Issue 1/2010

Archives of Orthopaedic and Trauma Surgery 1/2010 Go to the issue