Published in: Archives of Orthopaedic and Trauma Surgery 12/2008

01-12-2008 | Orthopaedic Surgery

Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6–10 years follow-up

Authors: Rob E. Zwartelé, Paul G. M. Olsthoorn, Rudolf G. Pöll, Ronald Brand, H. Cornelis Doets

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 12/2008

Login to get access

Abstract

Introduction

A flattened cup was designed to create a more physiological load transfer to the pelvic bone compared to hemispherical cups, and to allow more bone contact compared to low-profile’ spherical cups. To investigate these theoretical advantages and the potential influence of the quality of the acetabular bone, a clinical study was performed in patients with osteoarthritis (OA) and inflammatory arthritis (IA). The aims of the study were (1) to evaluate the fixation of the cup, postoperatively and later when osseous integration should have taken place, (2) to assess perioperative complications such as acetabular fractures and (3) to monitor the polar gap, a potential risk factor for osteolysis.

Patients and methods

A prospective study was performed on all consecutive OA and IA patients with an indication for primary total hip arthroplasty (THA). Three hundred and nine OA patients (340 hips) and 65 IA patients (76 hips) were included. The acetabular component was the flattened press-fit EPF-PLUS® cup, the femoral component the tapered cementless Zweymueller SL-PLUS® stem. All revisions and complications were recorded.
Clinical and radiographical evaluation was performed on regular basis during 6–10 years.

Results

The incidence of early loosening of the cup was 0 out of 340 in the OA group and 1 out of 76 in the IA group. The incidence of acetabular fractures was 7 out of 340 in the OA group and 3 out of 76 in the IA group. Failure rate for the acetabular component due to aseptic loosening or osteolysis after 6–10 years was 0% in the OA group and 4.8% in the IA group. In all cases available for follow-up the polar gap had disappeared and full osseous integration had taken place in both the groups.

Interpretation

This study shows that the flattened press-fit acetabular component creates adequate initial mechanical stability to allow osseous integration and that the cup can be safely used in both OA and IA patients. However, after 6–10 years, in the IA group failure of the cup due to aseptic loosening occurred once and failure due to osteolysis occurred three times, while these type of failures did not occur in the OA group.
Literature
1.
go back to reference Adler E, Stuchin SA, Kummer FJ (1992) Stability of press-fit acetabular cups. J Arthroplasty 7(3):295PubMedCrossRef Adler E, Stuchin SA, Kummer FJ (1992) Stability of press-fit acetabular cups. J Arthroplasty 7(3):295PubMedCrossRef
2.
go back to reference Åkesson K, Onsten I, Obrant KJ (1994) Periarticular bone in rheumatoid arthritis versus arthrosis. Histomorphometry in 103 hip biopsies. Acta Orthop Scand 65:135PubMed Åkesson K, Onsten I, Obrant KJ (1994) Periarticular bone in rheumatoid arthritis versus arthrosis. Histomorphometry in 103 hip biopsies. Acta Orthop Scand 65:135PubMed
3.
go back to reference Bogoch E, Gschwend N, Bogoch B et al (1988) Juxtaarticular bone loss in experimental inflammatory arthritis. J Orthop Res 6:648PubMedCrossRef Bogoch E, Gschwend N, Bogoch B et al (1988) Juxtaarticular bone loss in experimental inflammatory arthritis. J Orthop Res 6:648PubMedCrossRef
4.
go back to reference Bogoch ER, Moran EL (1999) Bone abnormalities in the surgical treatment of patients with rheumatoid arthritis. Clin Orthop 366:8PubMedCrossRef Bogoch ER, Moran EL (1999) Bone abnormalities in the surgical treatment of patients with rheumatoid arthritis. Clin Orthop 366:8PubMedCrossRef
5.
go back to reference Brooker AF, Bowerman JW, Robinson RA et al (1973) Ectopic ossification following total hip replacement. J Bone Joint Surg Am 51:737 Brooker AF, Bowerman JW, Robinson RA et al (1973) Ectopic ossification following total hip replacement. J Bone Joint Surg Am 51:737
6.
go back to reference Carlsson AS, Gentz C, Sanzen L (1986) Socket loosening after hip arthroplasty. Acta Orthop Scand 57:97PubMedCrossRef Carlsson AS, Gentz C, Sanzen L (1986) Socket loosening after hip arthroplasty. Acta Orthop Scand 57:97PubMedCrossRef
7.
go back to reference Creighton MG, Callaghan JJ, Olejniczak JP et al (1998) Total hip arthroplasty with cement in patients who have rheumatoid arthritis. J Bone Joint Surg Am 80(10):1439PubMed Creighton MG, Callaghan JJ, Olejniczak JP et al (1998) Total hip arthroplasty with cement in patients who have rheumatoid arthritis. J Bone Joint Surg Am 80(10):1439PubMed
8.
go back to reference DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20PubMed DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20PubMed
9.
go back to reference Della Valle GJ, Berger RA, Shott S et al (2004) Primary total hip arthroplasty with a porous-coated acetabular component. J Bone Joint Surg Am 86(6):1217PubMed Della Valle GJ, Berger RA, Shott S et al (2004) Primary total hip arthroplasty with a porous-coated acetabular component. J Bone Joint Surg Am 86(6):1217PubMed
10.
go back to reference Dorr LD, Wan Z, Cohen J (1998) Hemisperic titanium porous coated acetabular component without screw fixation. Clin Orthop Relat Res 351:158PubMedCrossRef Dorr LD, Wan Z, Cohen J (1998) Hemisperic titanium porous coated acetabular component without screw fixation. Clin Orthop Relat Res 351:158PubMedCrossRef
11.
go back to reference Effenberger H, Ramsauer T, Böhm G et al (2002) Successful hip arthroplasty using cementless titanium implants in rheumatoid arthritis. Arch Orthop Trauma Surg 122(2):80PubMedCrossRef Effenberger H, Ramsauer T, Böhm G et al (2002) Successful hip arthroplasty using cementless titanium implants in rheumatoid arthritis. Arch Orthop Trauma Surg 122(2):80PubMedCrossRef
12.
go back to reference Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures.Treatment by mold arthroplasty. J Bone Joint Surg Am 51:737PubMed Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures.Treatment by mold arthroplasty. J Bone Joint Surg Am 51:737PubMed
13.
go back to reference Kaplan EL, Meier P (1958) Nonparametric estimation of the life table method in analyzing survival. J Chronic Dis 53:457 Kaplan EL, Meier P (1958) Nonparametric estimation of the life table method in analyzing survival. J Chronic Dis 53:457
14.
go back to reference Katsimihas M, Taylor AH, Lee MB et al (2003) Cementless acetabular replacement in patients with rheumatoid arthritis. J Arthroplasty 18:16PubMedCrossRef Katsimihas M, Taylor AH, Lee MB et al (2003) Cementless acetabular replacement in patients with rheumatoid arthritis. J Arthroplasty 18:16PubMedCrossRef
15.
go back to reference Larsen A, Dale K, Eek M (1977) Radiographic evaluation of rheumatoid arthritis and related conditions by standard reference films. Acta Radiol Diagn 18:481 Larsen A, Dale K, Eek M (1977) Radiographic evaluation of rheumatoid arthritis and related conditions by standard reference films. Acta Radiol Diagn 18:481
16.
go back to reference MacKenzie JR, Callaghan JJ, Pedersen DP, Brown TD (1994) Areas of contact and extent of gaps with implantation of oversized acetabular components in total hip arthroplasty. Clin Orthop Relat Res 298:127–136PubMed MacKenzie JR, Callaghan JJ, Pedersen DP, Brown TD (1994) Areas of contact and extent of gaps with implantation of oversized acetabular components in total hip arthroplasty. Clin Orthop Relat Res 298:127–136PubMed
17.
go back to reference Massin P, Schmidt L, Engh CA (1989) Evaluation of cementless acetabular component migration. J Arthroplasty 4:245PubMedCrossRef Massin P, Schmidt L, Engh CA (1989) Evaluation of cementless acetabular component migration. J Arthroplasty 4:245PubMedCrossRef
18.
go back to reference Müller U, Gautier E, Roeder C et al (2003) The relationship between cup design and the radiological signs of aseptic loosening in total hip arthroplasty. J Bone Joint Surg Br 85:31PubMedCrossRef Müller U, Gautier E, Roeder C et al (2003) The relationship between cup design and the radiological signs of aseptic loosening in total hip arthroplasty. J Bone Joint Surg Br 85:31PubMedCrossRef
19.
go back to reference Oettmeier R, Babisch J (1992) Osteologic standardization of human coxarthrosis using histomorphometry and its relevance for hip alloarthroplasty. Pathol Res Pract 188:620PubMed Oettmeier R, Babisch J (1992) Osteologic standardization of human coxarthrosis using histomorphometry and its relevance for hip alloarthroplasty. Pathol Res Pract 188:620PubMed
20.
go back to reference Oosterbos CJ, Rahmy AI, Tonino AJ et al (2004) High survival rate of hydroxyapatite-coated hip prostheses: 100 consecutive hips followed for 10 years. Acta Orthop Scand 75:127–133PubMedCrossRef Oosterbos CJ, Rahmy AI, Tonino AJ et al (2004) High survival rate of hydroxyapatite-coated hip prostheses: 100 consecutive hips followed for 10 years. Acta Orthop Scand 75:127–133PubMedCrossRef
21.
go back to reference Paprosky WG, Perona PG, Lawrence JM (1994) Acetabular defect classification and surgical reconstruction in revision arthroplasty. J Arthroplasty 1:33CrossRef Paprosky WG, Perona PG, Lawrence JM (1994) Acetabular defect classification and surgical reconstruction in revision arthroplasty. J Arthroplasty 1:33CrossRef
22.
go back to reference Spears IR, Pfleiderer M, Schneider E et al (2000) Interfacial conditions between a press-fit acetabular cup and bone during daily activities: implications for achieving bone in-growth. J Biomech 33:1471PubMedCrossRef Spears IR, Pfleiderer M, Schneider E et al (2000) Interfacial conditions between a press-fit acetabular cup and bone during daily activities: implications for achieving bone in-growth. J Biomech 33:1471PubMedCrossRef
23.
go back to reference Spears IR, Pfeiderer M, Schneider E et al (2001) The effect of interfacial parameters on cup-bone relative micromotions. A finite element investigation. J Biomech 34:113–120PubMedCrossRef Spears IR, Pfeiderer M, Schneider E et al (2001) The effect of interfacial parameters on cup-bone relative micromotions. A finite element investigation. J Biomech 34:113–120PubMedCrossRef
24.
go back to reference Thomason HC, Lachiewicz PF (2001) The influence of technique on fixation of primary total hip arthroplasty in patients with rheumatoid arthritis. J Arthroplasty 16:628PubMedCrossRef Thomason HC, Lachiewicz PF (2001) The influence of technique on fixation of primary total hip arthroplasty in patients with rheumatoid arthritis. J Arthroplasty 16:628PubMedCrossRef
25.
go back to reference Trancik T, Mils W, Vinson N (1989) The effect of indomethacin, aspirin, and ibuprofen on bone ingrowth into a porous-coated implant. Clin Orthop Relat Res 249:113PubMed Trancik T, Mils W, Vinson N (1989) The effect of indomethacin, aspirin, and ibuprofen on bone ingrowth into a porous-coated implant. Clin Orthop Relat Res 249:113PubMed
26.
go back to reference Van der Lugt JC, Onstenk R, Nelissen RG (2003) Primary Stanmore total hip arthroplasty with increased cup loosening in rheumatoid patients. Int Orthop 27:291PubMedCrossRef Van der Lugt JC, Onstenk R, Nelissen RG (2003) Primary Stanmore total hip arthroplasty with increased cup loosening in rheumatoid patients. Int Orthop 27:291PubMedCrossRef
27.
go back to reference Widmer KD, Zurfluh B, Morscher EW (2002) Load transfer and fixation mode of press-fit acetabular sockets. J Arthroplasty 17:926PubMedCrossRef Widmer KD, Zurfluh B, Morscher EW (2002) Load transfer and fixation mode of press-fit acetabular sockets. J Arthroplasty 17:926PubMedCrossRef
28.
go back to reference Wroblewski BM, Siney PD, Fleming PA (2007) Charnley low-frictional torque arthroplasty in young rheumatoid and juvenile rheumatoid arthritis: 292 hips followed for an average of 15 years. Acta Orthop 78:206–210PubMedCrossRef Wroblewski BM, Siney PD, Fleming PA (2007) Charnley low-frictional torque arthroplasty in young rheumatoid and juvenile rheumatoid arthritis: 292 hips followed for an average of 15 years. Acta Orthop 78:206–210PubMedCrossRef
Metadata
Title
Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6–10 years follow-up
Authors
Rob E. Zwartelé
Paul G. M. Olsthoorn
Rudolf G. Pöll
Ronald Brand
H. Cornelis Doets
Publication date
01-12-2008
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 12/2008
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-008-0731-6

Other articles of this Issue 12/2008

Archives of Orthopaedic and Trauma Surgery 12/2008 Go to the issue