Abstract

Introduction: Lengthening procedures are often complicated by loosening of pins. It has been reported that coating with hydroxyapatite improves fixation and reduces the rate of pin-track infection. Materials and Methods: We compared 47 hydroxyapatite-coated Schanz screws (HA screws) in 12 monolateral fixators mounted at the University Hospital Hamburg–Eppendorf with 45 standard stainless steel screws in 9 monolateral fixators mounted at the St Josefs-Hospital Wiesbaden by measuring the insertion and extraction torque values. The average implantation period was 7 months for the hydroxyapatite-coated screws and 5.4 months for the uncoated screws. We established the quotient of the maximum extraction torque over insertion torque which shows the change in the fixation strength with respect to time, the fixation index. It eliminates the influence of the varying pin–bone contact. Results: There was no significant difference in the rate of infection. In the Schanz screws without signs of infection the index was 1.92 for the HA screws and 0.76 for the stainless steel screws (= 0.0002) giving evidence of the improvement of the fixation by the coating. Conclusion: HA coating resulted in improved fixation of Schanz screws in bone and may be useful in prolonged external fixation of the lower leg. The fixation index proved to be a simple tool for the evaluation of the fixation strength of Schanz screws.
Literature
1.
go back to reference Augat P, Claes L, Hanselmann KF, Suger G, Fleischmann W (1995) Increase of stability in fracture fixation by hydroxyapatite-coated bone screws. J Appl Biomater 6:99–104PubMedCrossRef Augat P, Claes L, Hanselmann KF, Suger G, Fleischmann W (1995) Increase of stability in fracture fixation by hydroxyapatite-coated bone screws. J Appl Biomater 6:99–104PubMedCrossRef
2.
go back to reference Cordoba F, Dong SS, Robinson M, States BS, Nimni ME (1993) Effects of microcrystalline hydroxyapatite on bone marrow stromal cell osteogenesis. 39th Annual meeting, Orthopaedic Research Society, San Francisco, CA, pp 15–18 Cordoba F, Dong SS, Robinson M, States BS, Nimni ME (1993) Effects of microcrystalline hydroxyapatite on bone marrow stromal cell osteogenesis. 39th Annual meeting, Orthopaedic Research Society, San Francisco, CA, pp 15–18
3.
go back to reference Dávid A, Pommer A, Eitenmüller J, Muhr G (1993) Der Einfluß der Hydroxylapatit-Beschichtung von AO/ASIF-Schrauben auf die Haftfestigkeit im Knochen. Unfallchirurg 96:12–17PubMed Dávid A, Pommer A, Eitenmüller J, Muhr G (1993) Der Einfluß der Hydroxylapatit-Beschichtung von AO/ASIF-Schrauben auf die Haftfestigkeit im Knochen. Unfallchirurg 96:12–17PubMed
4.
go back to reference Harada Y, Wang JT, Doppalapudi VA, Willis AA, Jasty M, Harris WH, Goldring SR (1994) Effects of hydroxyapatite/tricalciumphosphate particulates on human macrophage/monocytes in vitro. 40th Annual meeting, Orthopaedic Research Society, New Orleans, LA, pp 21–24 Harada Y, Wang JT, Doppalapudi VA, Willis AA, Jasty M, Harris WH, Goldring SR (1994) Effects of hydroxyapatite/tricalciumphosphate particulates on human macrophage/monocytes in vitro. 40th Annual meeting, Orthopaedic Research Society, New Orleans, LA, pp 21–24
5.
go back to reference Magyar G, Toksvig-Larsen S, Moroni A (1997) Hydroxyapatite coating of threaded pins enhances fixation. J Bone Joint Surg Br 79-B:487–489 doi: 0301–620X/97/37190 Magyar G, Toksvig-Larsen S, Moroni A (1997) Hydroxyapatite coating of threaded pins enhances fixation. J Bone Joint Surg Br 79-B:487–489 doi: 0301–620X/97/37190
6.
go back to reference Meiss L (1991) Experimentelle Untersuchungen und klinische Ergebnisse zur Stimulation der Knochenregeneration mit zerkleinerter Kortikalis und porösen Kalziumphosphatkeramiken (Trikalziumphosphat und Hydroxiapatit). Hefte zur Unfallheilkunde, Heft 216, Huggler AH, Kuner EH (Hrsg.), Springer, Berlin Heidelberg New York, pp 85–97 Meiss L (1991) Experimentelle Untersuchungen und klinische Ergebnisse zur Stimulation der Knochenregeneration mit zerkleinerter Kortikalis und porösen Kalziumphosphatkeramiken (Trikalziumphosphat und Hydroxiapatit). Hefte zur Unfallheilkunde, Heft 216, Huggler AH, Kuner EH (Hrsg.), Springer, Berlin Heidelberg New York, pp 85–97
7.
go back to reference Moroni A, Aspenberg P, Toksvig-Larsen S, Falzarano G, Giannini S (1998) Enhanced fixation with hydroxyapatite coated pins. Clin Orthop Relat Res 346:171–177PubMedCrossRef Moroni A, Aspenberg P, Toksvig-Larsen S, Falzarano G, Giannini S (1998) Enhanced fixation with hydroxyapatite coated pins. Clin Orthop Relat Res 346:171–177PubMedCrossRef
8.
go back to reference Moroni A, Toksvig-Larsen S, Maltarello MC, Orienti L, Stea S, Giannini S (1998) A comparison of hydroxyapatite-coated, titanium-coated and uncoated tapered external fixation pins. J Bone Joint Surg Am 80-A:547–554 Moroni A, Toksvig-Larsen S, Maltarello MC, Orienti L, Stea S, Giannini S (1998) A comparison of hydroxyapatite-coated, titanium-coated and uncoated tapered external fixation pins. J Bone Joint Surg Am 80-A:547–554
9.
go back to reference Moroni A, Faldini C, Marchetti S, Manca M, Consoli V, Giannini S (2001) Improvement of the bone–pin interface strength in osteoporotic bone with use of hydroxyapatite-coated tapered external fixation pins. J Bone Joint Surg Am 83-A 717–721PubMed Moroni A, Faldini C, Marchetti S, Manca M, Consoli V, Giannini S (2001) Improvement of the bone–pin interface strength in osteoporotic bone with use of hydroxyapatite-coated tapered external fixation pins. J Bone Joint Surg Am 83-A 717–721PubMed
10.
go back to reference Moroni A, Heikkila J, Magyar G, Toksvig-Larsen S, Giannini S (2001) Fixation strength and pin tract infection of hydroxyapatite-coated tapered pins. Clin Orthop Relat Res 388:209–217PubMedCrossRef Moroni A, Heikkila J, Magyar G, Toksvig-Larsen S, Giannini S (2001) Fixation strength and pin tract infection of hydroxyapatite-coated tapered pins. Clin Orthop Relat Res 388:209–217PubMedCrossRef
11.
go back to reference Moroni A, Faldini C, Pegreffi F, Giannini S (2004) HA-coated screws decrease the incidence of fixation failure in osteoporotic trochanteric fractures. Clin Orthop Relat Res 425:87–92PubMedCrossRef Moroni A, Faldini C, Pegreffi F, Giannini S (2004) HA-coated screws decrease the incidence of fixation failure in osteoporotic trochanteric fractures. Clin Orthop Relat Res 425:87–92PubMedCrossRef
12.
go back to reference Pettine KA, Chao EY, Kelly PJ (1993) Analysis of the external fixator pin–bone interface. Clin Orthop Relat Res 293:18–27PubMed Pettine KA, Chao EY, Kelly PJ (1993) Analysis of the external fixator pin–bone interface. Clin Orthop Relat Res 293:18–27PubMed
13.
go back to reference Placzek R, Hempfing A, Meiss AL (2001) Evaluation of hydroxyapatite-coated Schanz screws used in the Heidelberg external fixation system (HEFS). Biomed Tech 46:172–175 Placzek R, Hempfing A, Meiss AL (2001) Evaluation of hydroxyapatite-coated Schanz screws used in the Heidelberg external fixation system (HEFS). Biomed Tech 46:172–175
14.
go back to reference Placzek R, Deuretzbacher G, Meiss AL (2002) Bone fixation strength of the hydroxyapatite-coated Schanz-screws of the Heidelberg external fixation system (HEFS)—determination of torque in clinical application and in a cadaver tibia. Biomed Tech 47:323–325CrossRef Placzek R, Deuretzbacher G, Meiss AL (2002) Bone fixation strength of the hydroxyapatite-coated Schanz-screws of the Heidelberg external fixation system (HEFS)—determination of torque in clinical application and in a cadaver tibia. Biomed Tech 47:323–325CrossRef
15.
go back to reference Pizà G, Caja VL, Gonzàlez-Viejo MA, Navarro A (2004) Hydroxyapatite-coated external-fixation pins; the effect on pin loosening and pin-track infection in leg lengthening for short stature. J Bone Joint Surg Br 86-B:892–897 doi: 10.1302/0301–620X.86B.13875 Pizà G, Caja VL, Gonzàlez-Viejo MA, Navarro A (2004) Hydroxyapatite-coated external-fixation pins; the effect on pin loosening and pin-track infection in leg lengthening for short stature. J Bone Joint Surg Br 86-B:892–897 doi: 10.1302/0301–620X.86B.13875
16.
go back to reference Pommer A, Muhr G, Dàvid A (2002) Hydroxyapatite-coated Schanz pins in external fixators used for distraction osteogenesis: a randomised, controlled trial. J Bone Joint Surg Am 84:1162–1166PubMedCrossRef Pommer A, Muhr G, Dàvid A (2002) Hydroxyapatite-coated Schanz pins in external fixators used for distraction osteogenesis: a randomised, controlled trial. J Bone Joint Surg Am 84:1162–1166PubMedCrossRef
17.
go back to reference Sandén B, Olerud C, Petrén-Mallmin M, Larsson S (2002) Hydroxyapatite coating improves fixation of pedicle screws: a clinical study. J Bone Joint Surg Br 84:387–391 doi: 0301–620X/02/312388 Sandén B, Olerud C, Petrén-Mallmin M, Larsson S (2002) Hydroxyapatite coating improves fixation of pedicle screws: a clinical study. J Bone Joint Surg Br 84:387–391 doi: 0301–620X/02/312388
18.
go back to reference Schmidt HG, Neikes M, Wittek F (1990) Die Klassifikation der Osteomyelitis. Aktuelle Traumatol 20(6):303–309PubMed Schmidt HG, Neikes M, Wittek F (1990) Die Klassifikation der Osteomyelitis. Aktuelle Traumatol 20(6):303–309PubMed
Metadata
Title
The fixation strength of hydroxyapatite-coated Schanz screws and standard stainless steel Schanz screws in lower extremity lengthening
A comparison based on a new torque value index: the fixation index
Authors
R. Placzek
M. Ruffer
G. Deuretzbacher
E. Heijens
A. L. Meiss
Publication date
01-08-2006
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 6/2006
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-006-0142-5

Other articles of this Issue 6/2006

Archives of Orthopaedic and Trauma Surgery 6/2006 Go to the issue