Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 6/2005

01-07-2005 | Original Article

Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures

Authors: R. Arora, M. Lutz, D. Fritz, R. Zimmermann, J. Oberladstätter, M. Gabl

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 6/2005

Login to get access

Abstract

Introduction

This study investigates the clinical and radiological results of open reduction and internal fixation of unstable distal radial fractures using a palmar placed interlocking plate system with no substitutes for treatment of the dorsal metaphyseal fracture void.

Materials and methods

Nineteen patients with a mean age of 61 years (range 49–78 years) and a dorsally displaced distal radial fracture were treated using a palmar placed 2.4 mm interlocking plate system. All 17 women and 2 men were followed up according to the study protocol. Standardised radiographs in anteroposterior and lateral projection were performed before reduction and at 2, 6, 12 and 24 weeks after surgery. Radiological measurements included palmar tilt, radial inclination and radial shortening as defined by ulnar variance and intra-articular steps. Clinical assessment included active range of motion (ARM) of the wrist, pain according to a visual analogue scale (VAS), grip power, working ability, Disability of Arm, Shoulder and Hand-Score (DASH Score) and Mayo Wrist Score.

Results

At final follow-up after a minimum of 11 months, the palmar tilt was +1°, radial inclination 19.8° and ulnar variance 1.0 mm. Mean loss of palmar tilt measured 1.9°, radial inclination 1.3° and ulnar variance 0.4 mm. Mean wrist extension measured 58°, wrist flexion 41°, pronation 83° and supination 84°. The Mayo Wrist Score showed 21% excellent, 58% good, 16% fair and 5% poor results.

Conclusion

The treatment of unstable, dorsally dislocated, distal radius fractures AO types A3, C1 and C2, with a palmar placed 2.4 mm interlocking plate system and without additional treatment of the metaphyseal defects showed good radiological and functional results with minimal loss of reduction.
Literature
1.
go back to reference Axelrod TS, McMurtry RY (1990) Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius. J Hand Surg Am 15:1–11PubMed Axelrod TS, McMurtry RY (1990) Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius. J Hand Surg Am 15:1–11PubMed
2.
go back to reference Campbell DA (2000) Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal Radius plate. J Hand Surg Br 25:528–534CrossRefPubMed Campbell DA (2000) Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal Radius plate. J Hand Surg Br 25:528–534CrossRefPubMed
3.
go back to reference Carter PR, Frederick HA, Laseter GF (1998) Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: a multicenter study of 73 fractures. J Hand Surg Am 23:300–307PubMed Carter PR, Frederick HA, Laseter GF (1998) Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: a multicenter study of 73 fractures. J Hand Surg Am 23:300–307PubMed
4.
go back to reference Dias JJ, Wray CC, Jones JM (1987) Osteoporosis and Colle‘s fractures in the elderly. J Hand Surg Br 12:57–59PubMed Dias JJ, Wray CC, Jones JM (1987) Osteoporosis and Colle‘s fractures in the elderly. J Hand Surg Br 12:57–59PubMed
5.
go back to reference Dobretz H, Kutscha-Lissberg E (2002) Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 27:1-6PubMed Dobretz H, Kutscha-Lissberg E (2002) Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 27:1-6PubMed
6.
go back to reference Fernandez DL, Geissler WB (1991) Treatment of displaced articular fractures of the radius. J Hand Surg Am 16:375–384PubMed Fernandez DL, Geissler WB (1991) Treatment of displaced articular fractures of the radius. J Hand Surg Am 16:375–384PubMed
7.
go back to reference Garn Sm, Poznanski AK, Nagy JM (1971) Bone measurement in the differential diagnosis of osteopenia and osteoporosis. Radiology 100:509–518PubMed Garn Sm, Poznanski AK, Nagy JM (1971) Bone measurement in the differential diagnosis of osteopenia and osteoporosis. Radiology 100:509–518PubMed
8.
go back to reference Germann G, Wind G, Harth A (1999) The DASH Questionnaire—a new instrument for evaluating upper extremity treatment outcome. Handchir Mikrochir Plast Chir 31:149–152CrossRefPubMed Germann G, Wind G, Harth A (1999) The DASH Questionnaire—a new instrument for evaluating upper extremity treatment outcome. Handchir Mikrochir Plast Chir 31:149–152CrossRefPubMed
9.
go back to reference Green DP, O‘Brien ET (1978) Open reduction of carpal dislocations: indications and operative techniques. J Hand Surg Am 3:250-265PubMed Green DP, O‘Brien ET (1978) Open reduction of carpal dislocations: indications and operative techniques. J Hand Surg Am 3:250-265PubMed
10.
go back to reference Hirasawa Y, Katsumi Y, Akiyoshi T, Tamai K, Tokioka T (1990) Clinical and micro angiographic studies on rupture of the E.P.L. tendon after distal radius fractures. J Hand Surg Br 15:51–57PubMed Hirasawa Y, Katsumi Y, Akiyoshi T, Tamai K, Tokioka T (1990) Clinical and micro angiographic studies on rupture of the E.P.L. tendon after distal radius fractures. J Hand Surg Br 15:51–57PubMed
11.
go back to reference Hove LM, Helland P, Molster AO (1999) Dynamic traction for unstable fractures of the distal radius. J Hand Surg Br 24:210–214CrossRefPubMed Hove LM, Helland P, Molster AO (1999) Dynamic traction for unstable fractures of the distal radius. J Hand Surg Br 24:210–214CrossRefPubMed
12.
go back to reference Hove LM, Nilsen PT, Furnes O, Oulie HE, Solheim E, Molster AO (1997) Open reduction and internal fixation of displaced intraarticular fractures of the distal radius. Thirty-one patients followed for 3–7 years. Acta Orthop Scand 68:59–63PubMed Hove LM, Nilsen PT, Furnes O, Oulie HE, Solheim E, Molster AO (1997) Open reduction and internal fixation of displaced intraarticular fractures of the distal radius. Thirty-one patients followed for 3–7 years. Acta Orthop Scand 68:59–63PubMed
13.
go back to reference Jupiter JB et al (1997) Repair of five distal radius fractures with an investigational cancellous bone cement: a preliminary report. J Orthop Trauma 11:110–116CrossRefPubMed Jupiter JB et al (1997) Repair of five distal radius fractures with an investigational cancellous bone cement: a preliminary report. J Orthop Trauma 11:110–116CrossRefPubMed
14.
go back to reference Kamano M, Honda Y, Kazuki K, Yasuda M (2002) Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop 397:403–408PubMed Kamano M, Honda Y, Kazuki K, Yasuda M (2002) Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop 397:403–408PubMed
15.
go back to reference Kambouroglou GK, Axelrod TS (1998) Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: a brief report. J Hand Surg Am 23:737–741PubMed Kambouroglou GK, Axelrod TS (1998) Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: a brief report. J Hand Surg Am 23:737–741PubMed
16.
go back to reference Leung F et al (2003) Palmar plate fixation of AO Type C2 Fracture of distal radius using a locking compression plate—a biomechanical study in a cadaveric model. J Hand Surg Br 28:263–266CrossRefPubMed Leung F et al (2003) Palmar plate fixation of AO Type C2 Fracture of distal radius using a locking compression plate—a biomechanical study in a cadaveric model. J Hand Surg Br 28:263–266CrossRefPubMed
17.
go back to reference Nunley JA, Rowan PR (1999) Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius. J Hand Surg Am 24:1279–1280CrossRefPubMed Nunley JA, Rowan PR (1999) Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius. J Hand Surg Am 24:1279–1280CrossRefPubMed
18.
go back to reference Orbay JL, Fernandez DL (2004) Volar fixed-angle plate fixation for unstable distal radius fracture in the elderly patient. J Hand Surg Am 29:96–102CrossRefPubMed Orbay JL, Fernandez DL (2004) Volar fixed-angle plate fixation for unstable distal radius fracture in the elderly patient. J Hand Surg Am 29:96–102CrossRefPubMed
19.
go back to reference Pechlaner S (1993) Distale intraartikuläre Radiusfrakturen: Indikation und Technik der offenen Reposition und Plattenosteosynthese. Orthopäde 22:46–51 Pechlaner S (1993) Distale intraartikuläre Radiusfrakturen: Indikation und Technik der offenen Reposition und Plattenosteosynthese. Orthopäde 22:46–51
20.
go back to reference Ring D, Jupiter JB, Brennwald J, Buchler U, Hastings H 2nd (1997) Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg Am 22:777–784PubMed Ring D, Jupiter JB, Brennwald J, Buchler U, Hastings H 2nd (1997) Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg Am 22:777–784PubMed
21.
go back to reference Ring D, Prommersberger K, Jupiter JB (2004) Combined dorsal and volar plate fixation of complex fractures of the distal part of the radius. J Bone Joint Surg Am 86:1646–1652 Ring D, Prommersberger K, Jupiter JB (2004) Combined dorsal and volar plate fixation of complex fractures of the distal part of the radius. J Bone Joint Surg Am 86:1646–1652
22.
go back to reference Sailer R, Pechlaner S, Gabl M (1992) Plattenosteosynthese der Speiche. Eigenes Implantat und Technik. Handchir Mikrochir Plast Chir 24:284–291PubMed Sailer R, Pechlaner S, Gabl M (1992) Plattenosteosynthese der Speiche. Eigenes Implantat und Technik. Handchir Mikrochir Plast Chir 24:284–291PubMed
23.
go back to reference Schupp A, Tuttlies C, Möhlig T, Siebert HR (2003) Distal radius fracture 2.4 mm locking compression plates. Are they worth the effort? Der Chirurg 74:1009–1017CrossRef Schupp A, Tuttlies C, Möhlig T, Siebert HR (2003) Distal radius fracture 2.4 mm locking compression plates. Are they worth the effort? Der Chirurg 74:1009–1017CrossRef
24.
go back to reference Zimmermann R et al (2003) Injectable calcium phosphate bone cement Norian SRS for the treatment of intra-articular compression fractures of the distal radius in osteoporotic women. Arch Orthop Trauma Surg 123:22–27PubMed Zimmermann R et al (2003) Injectable calcium phosphate bone cement Norian SRS for the treatment of intra-articular compression fractures of the distal radius in osteoporotic women. Arch Orthop Trauma Surg 123:22–27PubMed
Metadata
Title
Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures
Authors
R. Arora
M. Lutz
D. Fritz
R. Zimmermann
J. Oberladstätter
M. Gabl
Publication date
01-07-2005
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 6/2005
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-005-0820-8

Other articles of this Issue 6/2005

Archives of Orthopaedic and Trauma Surgery 6/2005 Go to the issue