Skip to main content
Top
Published in: Heart and Vessels 6/2010

01-11-2010 | Original Article

Assessment of modified Blalock–Taussig shunt in children with congenital heart disease using multidetector-row computed tomography

Authors: Manal Mohamed Helmy Nabo, Yasunobu Hayabuchi, Miki Inoue, Noriko Watanabe, Miho Sakata, Shoji Kagami

Published in: Heart and Vessels | Issue 6/2010

Login to get access

Abstract

The purpose of this study was to assess the feasibility of multidetector-row computed tomography (MDCT) for the evaluation of modified Blalock–Taussig (B–T) shunt in children with congenital heart disease associated with reduced pulmonary blood flow. A total of 25 consecutive patients (mean age, 2.6 ± 3.6 years; range, 2 months–16 years) underwent MDCT angiography of the thorax with a 16-detector row scanner prior to cardiac catheterization. A total of 39 shunts (right, 22; left, 17) were included in the study. Conventional angiographic findings were used as the gold standard for the detection of B–T shunts. Shunt diameter was measured quantitatively and independently at four sites (the subclavian artery site, the pulmonary artery site, the widest site, and the stenotic site) on MDCT and on conventional invasive angiography. All B–T shunts were depicted on multiplanar reconstruction (MPR), maximum intensity projection (MIP), curved planar reconstruction (CPR), and three-dimensional volume-rendered (VR) images, enabling evaluation in all patients except for one with occluded shunt. There were excellent correlations between MDCT- and conventional angiography-based measurements of shunt diameter at the subclavian artery site, pulmonary artery site, and the widest site (R 2 = 0.46, 0.74 and 0.64, respectively; p < 0.0001 for each), although systematic overestimation was observed for MDCT (mean percentage of overestimation, 23.1 ± 32.4%). Stenotic site diameter and degree of stenosis showed a mild correlation (R 2 = 010 and 0.25, respectively; p < 0.01 for each). This study demonstrates that MDCT is a promising tool for the detection of lesions in B–T shunts.
Literature
1.
go back to reference Ilbawi MN, Grieco J, DeLeon SY, Idriss FS, Muster AJ, Berry TE, Klich J (1984) Modified Blalock–Taussig shunt in newborn infants. J Thorac Cardiovasc Surg 88:770–775PubMed Ilbawi MN, Grieco J, DeLeon SY, Idriss FS, Muster AJ, Berry TE, Klich J (1984) Modified Blalock–Taussig shunt in newborn infants. J Thorac Cardiovasc Surg 88:770–775PubMed
2.
go back to reference Motz R, Wessel A, Ruschewski W, Bürsch J (1999) Reduced frequency of occlusion of aorto-pulmonary shunts in infants receiving aspirin. Cardiol Young 9:474–477CrossRefPubMed Motz R, Wessel A, Ruschewski W, Bürsch J (1999) Reduced frequency of occlusion of aorto-pulmonary shunts in infants receiving aspirin. Cardiol Young 9:474–477CrossRefPubMed
3.
go back to reference Smith VC, Caggiano AV, Knauf DG, Alexander JA (1991) The Blalock–Taussig shunt in the newborn infant. J Thorac Cardiovasc Surg 102:602–605PubMed Smith VC, Caggiano AV, Knauf DG, Alexander JA (1991) The Blalock–Taussig shunt in the newborn infant. J Thorac Cardiovasc Surg 102:602–605PubMed
4.
go back to reference Fenton KN, Siewers RD, Rebovich B, Pigula FA (2003) Interim mortality in infants with systemic-to-pulmonary artery shunts. Ann Thorac Surg 76:152–156CrossRefPubMed Fenton KN, Siewers RD, Rebovich B, Pigula FA (2003) Interim mortality in infants with systemic-to-pulmonary artery shunts. Ann Thorac Surg 76:152–156CrossRefPubMed
5.
go back to reference Gillespie MJ, Rome JJ (2008) Transcatherter treatment for systemic-to-pulmonary shunt obstruction in infants and children. Catheter Cardiovasc Interv 71:928–935CrossRefPubMed Gillespie MJ, Rome JJ (2008) Transcatherter treatment for systemic-to-pulmonary shunt obstruction in infants and children. Catheter Cardiovasc Interv 71:928–935CrossRefPubMed
6.
go back to reference Sreeram N, Emmel M, Ben-Mime L, Brockmeier K, Bennink G (2008) Transcatheter recanalization of acutely occluded modified systemic to pulmonary artery shunts in infancy. Clin Res Cardiol 97:181–186CrossRefPubMed Sreeram N, Emmel M, Ben-Mime L, Brockmeier K, Bennink G (2008) Transcatheter recanalization of acutely occluded modified systemic to pulmonary artery shunts in infancy. Clin Res Cardiol 97:181–186CrossRefPubMed
7.
go back to reference Noda M, Takagi A, Kuwatsuru R, Mitsuhashi N, Kasanuki H (2008) Prognostic significance of multiple-detector computed tomography in conjunction with TIMI risk score for patients with non-ST elevation acute coronary syndrome. Heart Vessels 23:161–166CrossRefPubMed Noda M, Takagi A, Kuwatsuru R, Mitsuhashi N, Kasanuki H (2008) Prognostic significance of multiple-detector computed tomography in conjunction with TIMI risk score for patients with non-ST elevation acute coronary syndrome. Heart Vessels 23:161–166CrossRefPubMed
8.
go back to reference Pan NH, Yang HY, Hsieh MH, Chen YJ (2008) Coronary calcium score from multislice computed tomography correlates with QT dispersion and left ventricular wall thickness. Heart Vessels 23:155–160CrossRefPubMed Pan NH, Yang HY, Hsieh MH, Chen YJ (2008) Coronary calcium score from multislice computed tomography correlates with QT dispersion and left ventricular wall thickness. Heart Vessels 23:155–160CrossRefPubMed
9.
go back to reference Komatsu S, Sato Y, Ichikawa M, Kunimasa T, Ito S, Takagi T, Lee T, Matsumoto N, Takayama T, Ichikawa M, Hirayama A, Mishima M, Saito S, Kodama K (2008) Anomalous coronary arteries in adults detected by multislice computed tomography: presentation of cases from multicenter registry and review of the literature. Heart Vessels 23:26–34CrossRefPubMed Komatsu S, Sato Y, Ichikawa M, Kunimasa T, Ito S, Takagi T, Lee T, Matsumoto N, Takayama T, Ichikawa M, Hirayama A, Mishima M, Saito S, Kodama K (2008) Anomalous coronary arteries in adults detected by multislice computed tomography: presentation of cases from multicenter registry and review of the literature. Heart Vessels 23:26–34CrossRefPubMed
10.
go back to reference Hayabuchi Y, Mori K, Kitagawa T, Inoue M, Kagami S (2007) Accurate quantification of pulmonary artery diameter in patients with cyanotic congenital heart disease using multidetector-row computed tomography. Am Heart J 154:783–788CrossRefPubMed Hayabuchi Y, Mori K, Kitagawa T, Inoue M, Kagami S (2007) Accurate quantification of pulmonary artery diameter in patients with cyanotic congenital heart disease using multidetector-row computed tomography. Am Heart J 154:783–788CrossRefPubMed
11.
go back to reference Goo HW, Park IS, Ko JK, Kim YH, Seo DM, Park JJ (2005) Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients. Int J Cardiovasc Imaging 21:347–365CrossRefPubMed Goo HW, Park IS, Ko JK, Kim YH, Seo DM, Park JJ (2005) Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients. Int J Cardiovasc Imaging 21:347–365CrossRefPubMed
12.
go back to reference Okada M, Matsunaga N, Ito K, Takano K, Fujiwara M, Ueda K (2002) Modified Blalock–Taussig shunt patency for pulmonary atresia: assessment with electron beam CT. J Comput Assist Tomogr 26:368–372CrossRefPubMed Okada M, Matsunaga N, Ito K, Takano K, Fujiwara M, Ueda K (2002) Modified Blalock–Taussig shunt patency for pulmonary atresia: assessment with electron beam CT. J Comput Assist Tomogr 26:368–372CrossRefPubMed
13.
go back to reference Choi BW, Park YH, Lee JK, Kim MJ, Kim DJ, Ryu SJ, Cho BK, Choe KO (2003) Evaluation of the post-shunt status with electron beam computed tomography in cyanotic congenital heart disease. Yonsei Med J 44:249–258PubMed Choi BW, Park YH, Lee JK, Kim MJ, Kim DJ, Ryu SJ, Cho BK, Choe KO (2003) Evaluation of the post-shunt status with electron beam computed tomography in cyanotic congenital heart disease. Yonsei Med J 44:249–258PubMed
14.
go back to reference Duerinckx AJ, Wexler L, Banerjee A, Higgins SS, Hardy CE, Helton G, Rhee J, Mahboubi S, Higgins CB (1994) Postoperative evaluation of pulmonary arteries in congenital heart surgery by magnetic resonance imaging: comparison with echocardiography. Am Heart J 128:1139–1146CrossRefPubMed Duerinckx AJ, Wexler L, Banerjee A, Higgins SS, Hardy CE, Helton G, Rhee J, Mahboubi S, Higgins CB (1994) Postoperative evaluation of pulmonary arteries in congenital heart surgery by magnetic resonance imaging: comparison with echocardiography. Am Heart J 128:1139–1146CrossRefPubMed
15.
go back to reference Ichikawa T, Endo J, Koizumi J, Ro A, Kobayashi M, Saito M, Kawada S, Hashimoto T, Imai Y (2008) Visualization of the azygos arch valves on multidetector-row computed tomography. Heart Vessels 23:118–123CrossRefPubMed Ichikawa T, Endo J, Koizumi J, Ro A, Kobayashi M, Saito M, Kawada S, Hashimoto T, Imai Y (2008) Visualization of the azygos arch valves on multidetector-row computed tomography. Heart Vessels 23:118–123CrossRefPubMed
16.
go back to reference Hayashi H, Hidaka F, Kiriyama T, Sato H, Takagi R, Kumita S (2008) A left ventricular lipoma diagnosed on three-dimensional electrocardiogram-gated cardiac computed tomography. Heart Vessels 23:366–369CrossRefPubMed Hayashi H, Hidaka F, Kiriyama T, Sato H, Takagi R, Kumita S (2008) A left ventricular lipoma diagnosed on three-dimensional electrocardiogram-gated cardiac computed tomography. Heart Vessels 23:366–369CrossRefPubMed
17.
go back to reference Nabuchi A, Kurata A, Okuyama H, Kondo T, Muto Y, Endo Y (2008) Three-dimensional images of extra-routine grafts in CABG by multidetector computed tomography. Ann Thorac Cardiovasc Surg 14:333–335PubMed Nabuchi A, Kurata A, Okuyama H, Kondo T, Muto Y, Endo Y (2008) Three-dimensional images of extra-routine grafts in CABG by multidetector computed tomography. Ann Thorac Cardiovasc Surg 14:333–335PubMed
18.
go back to reference Mueller J, Jeudy J, Poston R, White CS (2007) Cardiac CT angiography after coronary bypass surgery: prevalence of incidental findings. Am J Roentgenol 189:414–419CrossRef Mueller J, Jeudy J, Poston R, White CS (2007) Cardiac CT angiography after coronary bypass surgery: prevalence of incidental findings. Am J Roentgenol 189:414–419CrossRef
19.
go back to reference Godart F, Qureshi SA, Simha A, Deverall PB, Anderson DR, Baker EJ, Tynan M (1998) Effects of modified and classic Blalock–Taussig shunts on the pulmonary arterial tree. Ann Thorac Surg 66:512–517CrossRefPubMed Godart F, Qureshi SA, Simha A, Deverall PB, Anderson DR, Baker EJ, Tynan M (1998) Effects of modified and classic Blalock–Taussig shunts on the pulmonary arterial tree. Ann Thorac Surg 66:512–517CrossRefPubMed
20.
go back to reference Ishizaka T, Yagihara T, Yamamoto F, Nishigaki K, Matsuki O, Uemura H, Yamashita K, Kamiya T, Kawashima Y (1996) Results of unifocalization for pulmonary atresia, ventricular septal defect and major aortopulmonary collateral arteries: patency of pulmonary vascular segments. Eur J Cardiothorac Surg 10:331–337CrossRefPubMed Ishizaka T, Yagihara T, Yamamoto F, Nishigaki K, Matsuki O, Uemura H, Yamashita K, Kamiya T, Kawashima Y (1996) Results of unifocalization for pulmonary atresia, ventricular septal defect and major aortopulmonary collateral arteries: patency of pulmonary vascular segments. Eur J Cardiothorac Surg 10:331–337CrossRefPubMed
21.
go back to reference Ley S, Zaporozhan J, Arnold R, Eichhorn J, Schenk JP, Ulmer H, Kreitner KF, Kauczor HU (2007) Preoperative assessment and follow-up of congenital abnormalities of the pulmonary arteries using CT and MRI. Eur Radiol 17:151–162CrossRefPubMed Ley S, Zaporozhan J, Arnold R, Eichhorn J, Schenk JP, Ulmer H, Kreitner KF, Kauczor HU (2007) Preoperative assessment and follow-up of congenital abnormalities of the pulmonary arteries using CT and MRI. Eur Radiol 17:151–162CrossRefPubMed
22.
go back to reference Hayabuchi Y, Mori K, Kitagawa T, Sakata M, Kagami S (2007) Polytetrafluoroethylene graft calcification in patients with surgically repaired congenital heart disease: evaluation using multidetector-row computed tomography. Am Heart J 153:806.e1–806.e8 Hayabuchi Y, Mori K, Kitagawa T, Sakata M, Kagami S (2007) Polytetrafluoroethylene graft calcification in patients with surgically repaired congenital heart disease: evaluation using multidetector-row computed tomography. Am Heart J 153:806.e1–806.e8
23.
go back to reference Donofrio MT, Clark BJ, Ramaciotti C, Jacob ML, Fellows KE, Weinberg PM, Fogel MA (1999) Regional wall motion and strain of transplanted hearts in pediatric patients using magnetic resonance tagging. Am J Physiol 277:R1481–R1487PubMed Donofrio MT, Clark BJ, Ramaciotti C, Jacob ML, Fellows KE, Weinberg PM, Fogel MA (1999) Regional wall motion and strain of transplanted hearts in pediatric patients using magnetic resonance tagging. Am J Physiol 277:R1481–R1487PubMed
24.
go back to reference Be’eri E, Maier SE, Landzberg MJ, Chung T, Geva T (1998) In vivo evaluation of Fontan pathway flow dynamics by multidimensional phase-velocity magnetic resonance imaging. Circulation 98:2873–2882PubMed Be’eri E, Maier SE, Landzberg MJ, Chung T, Geva T (1998) In vivo evaluation of Fontan pathway flow dynamics by multidimensional phase-velocity magnetic resonance imaging. Circulation 98:2873–2882PubMed
25.
go back to reference Roos JE, Willmann JK, Weishaupt D, Lachat M, Marincek B, Hilfiker PR (2002) Thoracic aorta: motion artifact reduction with retrospective and prospective electrocardiography-assisted multi-detector row CT. Radiology 222:271–277CrossRefPubMed Roos JE, Willmann JK, Weishaupt D, Lachat M, Marincek B, Hilfiker PR (2002) Thoracic aorta: motion artifact reduction with retrospective and prospective electrocardiography-assisted multi-detector row CT. Radiology 222:271–277CrossRefPubMed
26.
go back to reference Hein PA, Romano VC, Lembcke A, May J, Rogalla P (2009) Initial experience with a chest pain protocol using 320-slice volume MDCT. Eur Radiol 19:1148–1155CrossRefPubMed Hein PA, Romano VC, Lembcke A, May J, Rogalla P (2009) Initial experience with a chest pain protocol using 320-slice volume MDCT. Eur Radiol 19:1148–1155CrossRefPubMed
27.
go back to reference Morin RL, Gerber TC, McCollough CH (2003) Radiation dose in computed tomography of the heart. Circulation 107:917–922CrossRefPubMed Morin RL, Gerber TC, McCollough CH (2003) Radiation dose in computed tomography of the heart. Circulation 107:917–922CrossRefPubMed
28.
go back to reference Kuon E, Dahm JB, Robinson DM, Empen K, Günther M, Wucherer W (2005) Radiation-reducing planning of cardiac catheterisation. Z Kardiol 94:663–673CrossRefPubMed Kuon E, Dahm JB, Robinson DM, Empen K, Günther M, Wucherer W (2005) Radiation-reducing planning of cardiac catheterisation. Z Kardiol 94:663–673CrossRefPubMed
29.
go back to reference Bacher K, Bogaert E, Lapere R, De Wolf D, Thierens H (2005) Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 111:83–89CrossRefPubMed Bacher K, Bogaert E, Lapere R, De Wolf D, Thierens H (2005) Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 111:83–89CrossRefPubMed
Metadata
Title
Assessment of modified Blalock–Taussig shunt in children with congenital heart disease using multidetector-row computed tomography
Authors
Manal Mohamed Helmy Nabo
Yasunobu Hayabuchi
Miki Inoue
Noriko Watanabe
Miho Sakata
Shoji Kagami
Publication date
01-11-2010
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 6/2010
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-010-0007-2

Other articles of this Issue 6/2010

Heart and Vessels 6/2010 Go to the issue