Use of positive oral contrast agents in abdominopelvic computed tomography for blunt abdominal injury: meta-analysis and systematic review
Authors:
Chau Hung Lee, Benjamin Haaland, Arul Earnest, Cher Heng Tan
Published in:
European Radiology
|
Issue 9/2013
Login to get access
Abstract
Objectives
To determine whether positive oral contrast agents improve accuracy of abdominopelvic CT compared with no, neutral or negative oral contrast agent.
Methods
Literature was searched for studies evaluating the diagnostic performance of abdominopelvic CT with positive oral contrast agents against imaging with no, neutral or negative oral contrast agent. Meta-analysis reviewed studies correlating CT findings of blunt abdominal injury with positive and without oral contrast agents against surgical, autopsy or clinical outcome allowing derivation of pooled sensitivity and specificity. Systematic review was performed on studies with common design and reference standard.
Results
Thirty-two studies were divided into two groups. Group 1 comprised 15 studies comparing CT with positive and without oral contrast agents. Meta-analysis of five studies from group 1 provided no difference in sensitivity or specificity between CT with positive or without oral contrast agents. Group 2 comprised 17 studies comparing CT with positive and neutral or negative oral contrast agents. Systematic review of 12 studies from group 2 indicated that neutral or negative oral contrasts were as effective as positive oral contrast agents for bowel visualisation.
Conclusions
There is no difference in accuracy between CT performed with positive oral contrast agents or with no, neutral or negative oral contrast agent.
Key Points
• There is no difference in the accuracy of CT with or without oral contrast agent.
• There is no difference in the accuracy of CT with Gastrografin or water.
•Omission of oral contrast, utilising neutral or negative oral contrast agent saves time, costs and decreases risk of aspiration.