Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study

Authors: Boris Schulz, Katrin Eichler, Petra Siebenhandl, Tatjana Gruber-Rouh, Christoph Czerny, Thomas Josef Vogl, Stephan Zangos

Published in: European Radiology | Issue 1/2013

Login to get access

Abstract

Objective

To analyse the feasibility and accuracy of robotic aided interventions on a phantom when using a modern C-arm-mounted cone beam computed tomography (CBCT) device in combination with needle guidance software.

Methods

A small robotic device capable of holding and guiding needles was attached to the intervention table. After acquiring a 3D data set the access path was planned on the CBCT workstation and shown on the intervention monitor. Then the robot was aligned to the live fluorosopic image. A total of 40 punctures were randomly conducted on a phantom armed with several targets (diameter 2 mm) in single and double oblique trajectory (n = 20 each). Target distance, needle deviation and time for the procedures were analysed.

Results

All phantom interventions (n = 40) could be performed successfully. Mean target access path within the phantom was 8.5 cm (min 4.2 cm, max 13.5 cm). Average needle tip deviation was 1.1 mm (min 0 mm, max 4.5 mm), time duration was 3:59 min (min 2:07 min, max 10:37 min).

Conclusion

When using the proposed robot device in a CBCT intervention suite, highly accurate needle-based interventional punctures are possible in a reasonable timely manner in single as well as in double oblique trajectories.

Key Points

Percutaneous image-guided biopsy is an important contribution of modern radiology.
A compact robotic device has been developed which may facilitate such procedures.
Accurate needle-based interventions are possible in a timely manner.
Complex trajectories and even deep access paths are possible.
Literature
1.
go back to reference Gupta R, Cheung AC, Bartling SH et al (2008) Flat-panel volume CT: fundamental principles, technology, and applications. Radiographics 28:2009–2022PubMedCrossRef Gupta R, Cheung AC, Bartling SH et al (2008) Flat-panel volume CT: fundamental principles, technology, and applications. Radiographics 28:2009–2022PubMedCrossRef
2.
go back to reference Vogl TJ, Naguib NN, Nour-Eldin NE, Lehnert T, Mbalisike E (2009) C-arm computed tomography for transarterial chemoperfusion and chemo-embolization of thoracic lesions. Radiologe 49:837–841PubMedCrossRef Vogl TJ, Naguib NN, Nour-Eldin NE, Lehnert T, Mbalisike E (2009) C-arm computed tomography for transarterial chemoperfusion and chemo-embolization of thoracic lesions. Radiologe 49:837–841PubMedCrossRef
3.
go back to reference Kamran M, Nagaraja S, Byrne JV (2010) C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology. Neuroradiology 52:319–327PubMedCrossRef Kamran M, Nagaraja S, Byrne JV (2010) C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology. Neuroradiology 52:319–327PubMedCrossRef
4.
go back to reference Jin KN, Park CM, Goo JM et al (2010) Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems. Eur Radiol 20:2108–2115PubMedCrossRef Jin KN, Park CM, Goo JM et al (2010) Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems. Eur Radiol 20:2108–2115PubMedCrossRef
5.
go back to reference Zangos S, Melzer A, Eichler K et al (2011) MR-compatible assistance system for biopsy in a high-field-strength system: initial results in patients with suspicious prostate lesions. Radiology 259:903–910PubMedCrossRef Zangos S, Melzer A, Eichler K et al (2011) MR-compatible assistance system for biopsy in a high-field-strength system: initial results in patients with suspicious prostate lesions. Radiology 259:903–910PubMedCrossRef
6.
go back to reference Rasmus M, Huegli RW, Bilecen D, Jacob AL (2007) Robotically assisted CT-based procedures. Minim Invasive Ther Allied Technol 16:212–216PubMedCrossRef Rasmus M, Huegli RW, Bilecen D, Jacob AL (2007) Robotically assisted CT-based procedures. Minim Invasive Ther Allied Technol 16:212–216PubMedCrossRef
7.
go back to reference Onogi S, Morimoto K, Sakuma I et al (2005) Development of the needle insertion robot for percutaneous vertebroplasty. Med Image Comput Comput Assist Interv 8:105–113PubMed Onogi S, Morimoto K, Sakuma I et al (2005) Development of the needle insertion robot for percutaneous vertebroplasty. Med Image Comput Comput Assist Interv 8:105–113PubMed
8.
go back to reference Fichtinger G, Fiene JP, Kennedy CW et al (2008) Robotic assistance for ultrasound-guided prostate brachytherapy. Med Image Anal 12:535–545PubMedCrossRef Fichtinger G, Fiene JP, Kennedy CW et al (2008) Robotic assistance for ultrasound-guided prostate brachytherapy. Med Image Anal 12:535–545PubMedCrossRef
9.
go back to reference Cleary K, Melzer A, Watson V, Kronreif G, Stoianovici D (2006) Interventional robotic systems: applications and technology state-of-the-art. Minim Invasive Ther Allied Technol 15:101–113PubMedCrossRef Cleary K, Melzer A, Watson V, Kronreif G, Stoianovici D (2006) Interventional robotic systems: applications and technology state-of-the-art. Minim Invasive Ther Allied Technol 15:101–113PubMedCrossRef
10.
go back to reference Penzkofer T, Isfort P, Bruners P et al (2010) Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments. Eur Radiol 20:2656–2662PubMedCrossRef Penzkofer T, Isfort P, Bruners P et al (2010) Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments. Eur Radiol 20:2656–2662PubMedCrossRef
11.
go back to reference Tam AL, Mohamed A, Pfister M et al (2010) C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty. Spine 35:1095–1099PubMed Tam AL, Mohamed A, Pfister M et al (2010) C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty. Spine 35:1095–1099PubMed
12.
go back to reference Tovar-Arriaga S, Tita R, Pedraza-Ortega JC, Gorrostieta E, Kalender WA (2011) Development of a robotic FD-CT-guided navigation system for needle placement-preliminary accuracy tests. Int J Med Robot 7:225–236PubMedCrossRef Tovar-Arriaga S, Tita R, Pedraza-Ortega JC, Gorrostieta E, Kalender WA (2011) Development of a robotic FD-CT-guided navigation system for needle placement-preliminary accuracy tests. Int J Med Robot 7:225–236PubMedCrossRef
13.
go back to reference Yanof J, Haaga J, Klahr P et al (2001) CT-integrated robot for interventional procedures: preliminary experiment and computer-human interfaces. Comput Aided Surg 6:352–359PubMedCrossRef Yanof J, Haaga J, Klahr P et al (2001) CT-integrated robot for interventional procedures: preliminary experiment and computer-human interfaces. Comput Aided Surg 6:352–359PubMedCrossRef
14.
go back to reference Schell B, Eichler K, Mack MG et al (2012) Robot-assisted biopsies in a high-field MRI system - first clinical results. Rofo 184:42–47PubMedCrossRef Schell B, Eichler K, Mack MG et al (2012) Robot-assisted biopsies in a high-field MRI system - first clinical results. Rofo 184:42–47PubMedCrossRef
15.
go back to reference Cleary K, Freedman M, Clifford M, Lindisch D, Onda S, Jiang L (2001) Image-guided robotic delivery system for precise placement of therapeutic agents. J Control Release 74:363–368PubMedCrossRef Cleary K, Freedman M, Clifford M, Lindisch D, Onda S, Jiang L (2001) Image-guided robotic delivery system for precise placement of therapeutic agents. J Control Release 74:363–368PubMedCrossRef
16.
go back to reference Pfleiderer SO, Marx C, Vagner J, Franke RP, Reichenbach JR, Kaiser WA (2005) Magnetic resonance-guided large-core breast biopsy inside a 1.5-T magnetic resonance scanner using an automatic system: in vitro experiments and preliminary clinical experience in four patients. Invest Radiol 40:458–463PubMedCrossRef Pfleiderer SO, Marx C, Vagner J, Franke RP, Reichenbach JR, Kaiser WA (2005) Magnetic resonance-guided large-core breast biopsy inside a 1.5-T magnetic resonance scanner using an automatic system: in vitro experiments and preliminary clinical experience in four patients. Invest Radiol 40:458–463PubMedCrossRef
17.
go back to reference Cadeddu JA, Bzostek A, Schreiner S et al (1997) A robotic system for percutaneous renal access. J Urol 158:1589–1593PubMedCrossRef Cadeddu JA, Bzostek A, Schreiner S et al (1997) A robotic system for percutaneous renal access. J Urol 158:1589–1593PubMedCrossRef
18.
go back to reference Ritter M, Rassweiler MC, Hacker A, Michel MS (2012) Laser-guided percutaneous kidney access with the Uro Dyna-CT: first experience of three-dimensional puncture planning with an ex vivo model. World J Urol. doi:10.1007/s00345-012-0847-8 Ritter M, Rassweiler MC, Hacker A, Michel MS (2012) Laser-guided percutaneous kidney access with the Uro Dyna-CT: first experience of three-dimensional puncture planning with an ex vivo model. World J Urol. doi:10.​1007/​s00345-012-0847-8
19.
go back to reference Murayama Y, Irie K, Saguchi T et al (2011) Robotic digital subtraction angiography systems within the hybrid operating room. Neurosurgery 68:1427–1432PubMed Murayama Y, Irie K, Saguchi T et al (2011) Robotic digital subtraction angiography systems within the hybrid operating room. Neurosurgery 68:1427–1432PubMed
20.
go back to reference Schulz B, Heidenreich R, Heidenreich M, et al. (2012) Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications. Eur J Radiol. doi:10.1016/j.ejrad.2012.01.010 Schulz B, Heidenreich R, Heidenreich M, et al. (2012) Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications. Eur J Radiol. doi:10.​1016/​j.​ejrad.​2012.​01.​010
21.
Metadata
Title
Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study
Authors
Boris Schulz
Katrin Eichler
Petra Siebenhandl
Tatjana Gruber-Rouh
Christoph Czerny
Thomas Josef Vogl
Stephan Zangos
Publication date
01-01-2013
Publisher
Springer-Verlag
Published in
European Radiology / Issue 1/2013
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-012-2585-0

Other articles of this Issue 1/2013

European Radiology 1/2013 Go to the issue