Skip to main content
Top
Published in: European Radiology 11/2010

01-11-2010 | Vascular-Interventional

Comparison of standard- and low-tube voltage MDCT angiography in patients with peripheral arterial disease

Authors: Daisuke Utsunomiya, Seitaro Oda, Yoshinori Funama, Kazuo Awai, Takeshi Nakaura, Yumi Yanaga, Toshinori Hirai, Yasuyuki Yamashita

Published in: European Radiology | Issue 11/2010

Login to get access

Abstract

Objective:

We investigated the effect of low-tube-voltage CT angiography with a reduced volume of contrast agent on qualitative and quantitative parameters and the radiation dose in patients with peripheral arterial disease.

Methods:

Eighty consecutive patients were divided into two groups; the protocol was 120 kVp and 1.8 ml/kg contrast agent (300 mgI/ml) in one group and 80 kVp and 1.2 ml/kg in the other. For quantitative analysis we calculated the mean arterial attenuation, the mean difference between maximum and minimum attenuation values, contrast-to-noise ratio (CNR), and figure of merit (FOM). For qualitative evaluation, we used visual scores.

Results:

There were no significant intergroup differences in mean arterial attenuation (120 vs. 80 kVp: 331.6 ± 61.6 vs. 354.9 ± 61.9 HU) and in the mean difference between maximum and minimum attenuation (120 vs. 80 kVp: 52.2 ± 25.5 vs. 61.5 ± 27.5 HU). While the mean CNR was significantly higher at 120 than 80 kVp (38.4 ± 18.8 vs. 31.1 ± 15.3), the mean FOM was not significantly different (120 vs. 80 kVp: 1.3 ± 1.5 vs. 1.2 ± 1.2), and there was no significant intergroup difference in visual scores. The mean dose-length product was significantly lower at 80 than 120 kVp (1,024.3 ± 151.3 vs. 1,464.7 ± 208.7 mGy·cm).

Conclusion:

The 80-kVp protocol allows for reduction of the radiation dose by approximately 30% and the volume of contrast agent by more than 30% without deterioration of vascular enhancement and image quality.
Literature
1.
go back to reference Rubin GD (2003) MDCT imaging of the aorta and peripheral vessels. Eur J Radiol 45(Suppl 1):S42–S49CrossRefPubMed Rubin GD (2003) MDCT imaging of the aorta and peripheral vessels. Eur J Radiol 45(Suppl 1):S42–S49CrossRefPubMed
2.
go back to reference Fleischmann D, Lammer J (2006) Peripheral CT angiography for interventional treatment planning. Eur Radiol 16(Suppl 7):M58–M64PubMed Fleischmann D, Lammer J (2006) Peripheral CT angiography for interventional treatment planning. Eur Radiol 16(Suppl 7):M58–M64PubMed
3.
go back to reference Schernthaner R, Stadler A, Lomoschitz F et al (2008) Multidetector CT angiography in the assessment of peripheral arterial occlusive disease: accuracy in detecting the severity, number, and length of stenoses. Eur Radiol 18:665–671CrossRefPubMed Schernthaner R, Stadler A, Lomoschitz F et al (2008) Multidetector CT angiography in the assessment of peripheral arterial occlusive disease: accuracy in detecting the severity, number, and length of stenoses. Eur Radiol 18:665–671CrossRefPubMed
4.
go back to reference Met R, Bipat S, Legemate DA, Reekers JA, Koelemay MJ (2009) Diagnostic performance of computed tomography angiography in peripheral arterial disease: a systematic review and meta-analysis. Jama 301:415–424CrossRefPubMed Met R, Bipat S, Legemate DA, Reekers JA, Koelemay MJ (2009) Diagnostic performance of computed tomography angiography in peripheral arterial disease: a systematic review and meta-analysis. Jama 301:415–424CrossRefPubMed
5.
go back to reference Paraskevas KI, Giannoukas AD, Mikhailidis DP (2009) Renal function impairment in peripheral arterial disease: an important parameter that should not be neglected. Ann Vasc Surg 23:690–699CrossRefPubMed Paraskevas KI, Giannoukas AD, Mikhailidis DP (2009) Renal function impairment in peripheral arterial disease: an important parameter that should not be neglected. Ann Vasc Surg 23:690–699CrossRefPubMed
6.
go back to reference Thomsen HS, Morcos SK (2009) Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT–a pooled analysis of two randomized trials. Eur Radiol 19:891–897CrossRefPubMed Thomsen HS, Morcos SK (2009) Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT–a pooled analysis of two randomized trials. Eur Radiol 19:891–897CrossRefPubMed
7.
go back to reference Nakayama Y, Awai K, Funama Y et al (2006) Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography. AJR Am J Roentgenol 187:W490–W497CrossRefPubMed Nakayama Y, Awai K, Funama Y et al (2006) Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography. AJR Am J Roentgenol 187:W490–W497CrossRefPubMed
8.
go back to reference Schueller-Weidekamm C, Schaefer-Prokop CM, Weber M, Herold CJ, Prokop M (2006) CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings. Radiology 241:899–907CrossRefPubMed Schueller-Weidekamm C, Schaefer-Prokop CM, Weber M, Herold CJ, Prokop M (2006) CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings. Radiology 241:899–907CrossRefPubMed
9.
go back to reference Funama Y, Awai K, Nakayama Y et al (2005) Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology 237:905–910CrossRefPubMed Funama Y, Awai K, Nakayama Y et al (2005) Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology 237:905–910CrossRefPubMed
10.
go back to reference Leschka S, Stolzmann P, Schmid FT et al (2008) Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose. Eur Radiol 18:1809–1817CrossRefPubMed Leschka S, Stolzmann P, Schmid FT et al (2008) Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose. Eur Radiol 18:1809–1817CrossRefPubMed
11.
go back to reference Yanaga Y, Awai K, Nakaura T et al (2009) Effect of contrast injection protocols with dose adjusted to the estimated lean patient body weight on aortic enhancement at CT angiography. AJR Am J Roentgenol 192:1071–1078CrossRefPubMed Yanaga Y, Awai K, Nakaura T et al (2009) Effect of contrast injection protocols with dose adjusted to the estimated lean patient body weight on aortic enhancement at CT angiography. AJR Am J Roentgenol 192:1071–1078CrossRefPubMed
12.
go back to reference Fleischmann D, Hallett RL, Rubin GD (2006) CT angiography of peripheral arterial disease. J Vasc Interv Radiol 17:3–26CrossRefPubMed Fleischmann D, Hallett RL, Rubin GD (2006) CT angiography of peripheral arterial disease. J Vasc Interv Radiol 17:3–26CrossRefPubMed
13.
go back to reference Nakaya Y, Kim T, Hori M et al (2009) Sixty-four-slice multidetector row computed tomographic angiography of aortoiliac and lower extremity arteries: efficacy of test injection using a monitoring scan at knee level. J Comput Assist Tomogr 33:20–25CrossRefPubMed Nakaya Y, Kim T, Hori M et al (2009) Sixty-four-slice multidetector row computed tomographic angiography of aortoiliac and lower extremity arteries: efficacy of test injection using a monitoring scan at knee level. J Comput Assist Tomogr 33:20–25CrossRefPubMed
14.
go back to reference Jessen KA, Shrimpton PC, Geleijns J, Panzer W, Tosi G (1999) Dosimetry for optimisation of patient protection in computed tomography. Appl Radiat Isot 50:165–172CrossRefPubMed Jessen KA, Shrimpton PC, Geleijns J, Panzer W, Tosi G (1999) Dosimetry for optimisation of patient protection in computed tomography. Appl Radiat Isot 50:165–172CrossRefPubMed
15.
go back to reference Sigal-Cinqualbre AB, Hennequin R, Abada HT, Chen X, Paul JF (2004) Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 231:169–174CrossRefPubMed Sigal-Cinqualbre AB, Hennequin R, Abada HT, Chen X, Paul JF (2004) Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 231:169–174CrossRefPubMed
16.
go back to reference Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217:430–435PubMed Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217:430–435PubMed
17.
go back to reference Utsunomiya D, Awai K, Tamura Y et al (2006) 16-MDCT aortography with a low-dose contrast material protocol. AJR Am J Roentgenol 186:374–378CrossRefPubMed Utsunomiya D, Awai K, Tamura Y et al (2006) 16-MDCT aortography with a low-dose contrast material protocol. AJR Am J Roentgenol 186:374–378CrossRefPubMed
18.
go back to reference Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, Pavlicek W (2009) Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193:764–771CrossRefPubMed Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, Pavlicek W (2009) Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193:764–771CrossRefPubMed
19.
go back to reference Silva AC, Lawder HJ, Hara A, Kujak J, Pavlicek W (2010) Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol 194:191–199CrossRefPubMed Silva AC, Lawder HJ, Hara A, Kujak J, Pavlicek W (2010) Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol 194:191–199CrossRefPubMed
20.
go back to reference Yanaga Y, Awai K, Funama Y et al (2009) Low-dose MDCT urography: feasibility study of low-tube-voltage technique and adaptive noise reduction filter. AJR Am J Roentgenol 193:W220–W229CrossRefPubMed Yanaga Y, Awai K, Funama Y et al (2009) Low-dose MDCT urography: feasibility study of low-tube-voltage technique and adaptive noise reduction filter. AJR Am J Roentgenol 193:W220–W229CrossRefPubMed
21.
go back to reference Loewe C, Schoder M, Rand T et al (2002) Peripheral vascular occlusive disease: evaluation with contrast-enhanced moving-bed MR angiography versus digital subtraction angiography in 106 patients. AJR Am J Roentgenol 179:1013–1021PubMed Loewe C, Schoder M, Rand T et al (2002) Peripheral vascular occlusive disease: evaluation with contrast-enhanced moving-bed MR angiography versus digital subtraction angiography in 106 patients. AJR Am J Roentgenol 179:1013–1021PubMed
22.
go back to reference Ouwendijk R, de Vries M, Pattynama PM et al (2005) Imaging peripheral arterial disease: a randomized controlled trial comparing contrast-enhanced MR angiography and multi-detector row CT angiography. Radiology 236:1094–1103CrossRefPubMed Ouwendijk R, de Vries M, Pattynama PM et al (2005) Imaging peripheral arterial disease: a randomized controlled trial comparing contrast-enhanced MR angiography and multi-detector row CT angiography. Radiology 236:1094–1103CrossRefPubMed
23.
go back to reference Ouwendijk R, de Vries M, Stijnen T et al (2008) Multicenter randomized controlled trial of the costs and effects of noninvasive diagnostic imaging in patients with peripheral arterial disease: the DIPAD trial. AJR Am J Roentgenol 190:1349–1357CrossRefPubMed Ouwendijk R, de Vries M, Stijnen T et al (2008) Multicenter randomized controlled trial of the costs and effects of noninvasive diagnostic imaging in patients with peripheral arterial disease: the DIPAD trial. AJR Am J Roentgenol 190:1349–1357CrossRefPubMed
24.
go back to reference Nakayama Y, Awai K, Funama Y et al (2005) Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise. Radiology 237:945–951CrossRefPubMed Nakayama Y, Awai K, Funama Y et al (2005) Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise. Radiology 237:945–951CrossRefPubMed
Metadata
Title
Comparison of standard- and low-tube voltage MDCT angiography in patients with peripheral arterial disease
Authors
Daisuke Utsunomiya
Seitaro Oda
Yoshinori Funama
Kazuo Awai
Takeshi Nakaura
Yumi Yanaga
Toshinori Hirai
Yasuyuki Yamashita
Publication date
01-11-2010
Publisher
Springer-Verlag
Published in
European Radiology / Issue 11/2010
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-010-1841-4

Other articles of this Issue 11/2010

European Radiology 11/2010 Go to the issue