Abstract

Objectives

To determine the diagnostic value of the anterior chamber depth (ACD) of a globe as seen on CT for detecting open-globe injury.

Methods

We enrolled 28 patients with unilateral open-globe injury confirmed by surgery and 28 controls with other types of orbital trauma. The diagnostic value of the difference of the ACDs between globes was evaluated by ROC analysis. The diagnostic performance of the following CT findings suggesting open-globe injury was also determined from independent analysis by two readers, i.e. change in the ACD and the globe contour, obvious volume loss of the globe, dislocated/deformed lens, intraocular foreign body/air and intraocular haemorrhage.

Results

The ACD measurements were possible only in 15 patients with open-globe injuries. A difference in the ACDs ≥0.4 mm resulted in 0.85 of the area under the ROC curve with a sensitivity of 73% and specificity of 100% (p = 0.0001). The presence of one or more of the CT findings had a sensitivity of 92%, specificity of 85% and diagnostic accuracy of 89%.

Conclusions

Change in the ACD is a helpful CT finding for detecting open-globe injury. A difference in the ACDs ≥0.4 mm is a helpful diagnostic criterion with excellent specificity.
Literature
1.
go back to reference Rahman I, Maino A, Devadason D, Leatherbarrow B (2006) Open globe injuries: factors predictive of poor outcome. Eye 20:1336–1341CrossRefPubMed Rahman I, Maino A, Devadason D, Leatherbarrow B (2006) Open globe injuries: factors predictive of poor outcome. Eye 20:1336–1341CrossRefPubMed
2.
go back to reference Bord SP, Linden J (2008) Trauma to the globe and orbit. Emerg Med Clin North Am 26:97–123 vi–viiCrossRefPubMed Bord SP, Linden J (2008) Trauma to the globe and orbit. Emerg Med Clin North Am 26:97–123 vi–viiCrossRefPubMed
3.
go back to reference Joseph DP, Pieramici DJ, Beauchamp NJ Jr (2000) Computed tomography in the diagnosis and prognosis of open-globe injuries. Ophthalmology 107:1899–1906CrossRefPubMed Joseph DP, Pieramici DJ, Beauchamp NJ Jr (2000) Computed tomography in the diagnosis and prognosis of open-globe injuries. Ophthalmology 107:1899–1906CrossRefPubMed
4.
go back to reference Weissman JL, Beatty RL, Hirsch WL, Curtin HD (1995) Enlarged anterior chamber: CT finding of a ruptured globe. AJNR Am J Neuroradiol 16:936–938PubMed Weissman JL, Beatty RL, Hirsch WL, Curtin HD (1995) Enlarged anterior chamber: CT finding of a ruptured globe. AJNR Am J Neuroradiol 16:936–938PubMed
6.
go back to reference Sevel D, Krausz H, Ponder T, Centeno R (1983) Value of computed tomography for the diagnosis of a ruptured eye. J Comput Assist Tomogr 7:870–875CrossRefPubMed Sevel D, Krausz H, Ponder T, Centeno R (1983) Value of computed tomography for the diagnosis of a ruptured eye. J Comput Assist Tomogr 7:870–875CrossRefPubMed
7.
go back to reference Arey ML, Mootha VV, Whittemore AR, Chason DP, Blomquist PH (2007) Computed tomography in the diagnosis of occult open-globe injuries. Ophthalmology 114:1448–1452CrossRefPubMed Arey ML, Mootha VV, Whittemore AR, Chason DP, Blomquist PH (2007) Computed tomography in the diagnosis of occult open-globe injuries. Ophthalmology 114:1448–1452CrossRefPubMed
8.
go back to reference Xu L, Cao WF, Wang YX, Chen CX, Jonas JB (2008) Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing Eye Study. Am J Ophthalmol 145:929–936CrossRefPubMed Xu L, Cao WF, Wang YX, Chen CX, Jonas JB (2008) Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing Eye Study. Am J Ophthalmol 145:929–936CrossRefPubMed
9.
go back to reference Yi JH, Hong S, Seong GJ, Kang SY, Ma KT, Kim CY (2008) Anterior chamber measurements by pentacam and AS-OCT in eyes with normal open angles. Korean J Ophthalmol 22:242–245CrossRefPubMed Yi JH, Hong S, Seong GJ, Kang SY, Ma KT, Kim CY (2008) Anterior chamber measurements by pentacam and AS-OCT in eyes with normal open angles. Korean J Ophthalmol 22:242–245CrossRefPubMed
10.
go back to reference Mader TH, Werner RP, Chamberlain DG (2008) Corneal perforation and delayed anterior chamber collapse from a devil’s club thorn. Cornea 27:961–962CrossRefPubMed Mader TH, Werner RP, Chamberlain DG (2008) Corneal perforation and delayed anterior chamber collapse from a devil’s club thorn. Cornea 27:961–962CrossRefPubMed
Metadata
Title
Diagnostic value of the anterior chamber depth of a globe on CT for detecting open-globe injury
Authors
Seong Yun Kim
Jeong Hyun Lee
Yong Jae Lee
Byung Se Choi
Jin Woo Choi
Hyun Sin In
Sun Mi Kim
Jung Hwan Baek
Publication date
01-05-2010
Publisher
Springer-Verlag
Published in
European Radiology / Issue 5/2010
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-009-1653-6

Other articles of this Issue 5/2010

European Radiology 5/2010 Go to the issue