Computer-aided detection of pulmonary embolism: Influence on radiologists’ detection performance with respect to vessel segments
Authors:
Marco Das, Georg Mühlenbruch, Anita Helm, Annemarie Bakai, Marcos Salganicoff, Sven Stanzel, Jianming Liang, Matthias Wolf, Rolf W. Günther, Joachim Ernst Wildberger
Published in:
European Radiology
|
Issue 7/2008
Login to get access
Abstract
The purpose was to assess the sensitivity of a CAD software prototype for the detection of pulmonary embolism in MDCT chest examinations with regard to vessel level and to assess the influence on radiologists’ detection performance. Forty-three patients with suspected PE were included in this retrospective study. MDCT chest examinations with a standard PE protocol were acquired at a 16-slice MDCT. All patient data were read by three radiologists (R1, R2, R3), and all thrombi were marked. A CAD prototype software was applied to all datasets, and each finding of the software was analyzed with regard to vessel level. The standard of reference was assessed in a consensus read. Sensitivity for the radiologists and CAD software was assessed. Thirty-three patients were positive for PE, with a total of 215 thrombi. The mean overall sensitivity for the CAD software alone was 83% (specificity, 80%). Radiologist sensitivity was 77% = R3, 82% = R2, and R1 = 87%. With the aid of the CAD software, sensitivities increased to 98% (R1), 93% (R2), and 92% (R3) (p<0.0001). CAD performance at the lobar level was 87%, at the segmental 90% and at the subsegmental 77%. With the use of CAD for PE, the detection performance of radiologists can be improved.