Skip to main content
Top
Published in: European Radiology 9/2007

01-09-2007 | Cardiac

Myocardial tagging with steady state free precession techniques and semi-automatic postprocessing—impact on diagnostic value

Authors: Thorsten R. C. Johnson, Nicole Bayrhof, Armin Huber, Joost P. A. Kuijer, Roger Luechinger, Olaf Dietrich, Dietrich Stoevesandt, Dorthe Pedersen, Maximilian F. Reiser, Stefan O. Schoenberg

Published in: European Radiology | Issue 9/2007

Login to get access

Abstract

Our aim was to determine the diagnostic value of myocardial tagging sequences with regard to the evaluable share of the cardiac cycle. Thirty-three patients were examined at 1.5 T using tagging sequences with gradient-echo (GRE) readout, 18 patients at 1.5 T with steady-state free precession (SSFP), and 11 patients at 3 T using GRE. Two observers graded image quality and determined the share of the cardiac cycle for which postprocessing could be performed (1, optimal; 2, little interaction; 3, whole cycle assessable; 4, diastole non-assessable; 5, systole incomplete; 6, non-diagnostic). With GRE at 1.5 T, median image quality was 4.0 (95% CI 4.0–5.0), while it was significantly better with 2.0 (2.0–3.0) using the SSFP technique and similar at 3 T with 2.9 (1.7–3.5). With GRE at 1.5 T, systole could be assessed in 69% of patients, and an evaluation of the whole cardiac cycle was not possible. With the SSFP sequence at 1.5 T and GRE at 3 T, an evaluation of the whole cardiac cycle was possible in 71% and 70% of the patients, respectively, and systole was assessable in all patients. Tagging sequences with SSFP readout at 1.5 T make a semi-automatic evaluation of the whole cardiac cycle feasible in a large share of patients.
Literature
1.
go back to reference Zerhouni EA, Parish DM, Rogers WJ, Yang A, Shapiro EP (1988) Human heart: tagging with MR imaging—a method for noninvasive assessment of myocardial motion. Radiology 169:59–63PubMed Zerhouni EA, Parish DM, Rogers WJ, Yang A, Shapiro EP (1988) Human heart: tagging with MR imaging—a method for noninvasive assessment of myocardial motion. Radiology 169:59–63PubMed
2.
go back to reference Axel L, Dougherty L (1989) MR imaging of motion with spatial modulation of magnetization. Radiology 171:841–845PubMed Axel L, Dougherty L (1989) MR imaging of motion with spatial modulation of magnetization. Radiology 171:841–845PubMed
3.
go back to reference Fischer SE, McKinnon GC, Maier SE, Boesiger P (1993) Improved myocardial tagging contrast. Magn Reson Med 30:191–200PubMedCrossRef Fischer SE, McKinnon GC, Maier SE, Boesiger P (1993) Improved myocardial tagging contrast. Magn Reson Med 30:191–200PubMedCrossRef
4.
go back to reference Mosher TJ, Smith MB (1990) A DANTE tagging sequence for the evaluation of translational sample motion. Magn Reson Med 15:334–339PubMedCrossRef Mosher TJ, Smith MB (1990) A DANTE tagging sequence for the evaluation of translational sample motion. Magn Reson Med 15:334–339PubMedCrossRef
5.
go back to reference Stuber M, Fischer SE, Scheidegger MB, Boesiger P (1999) Toward high-resolution myocardial tagging. Magn Reson Med 41:639–643PubMedCrossRef Stuber M, Fischer SE, Scheidegger MB, Boesiger P (1999) Toward high-resolution myocardial tagging. Magn Reson Med 41:639–643PubMedCrossRef
6.
go back to reference Peters DC, Epstein FH, McVeigh ER (2001) Myocardial wall tagging with undersampled projection reconstruction. Magn Reson Med 45:562–567PubMedCrossRef Peters DC, Epstein FH, McVeigh ER (2001) Myocardial wall tagging with undersampled projection reconstruction. Magn Reson Med 45:562–567PubMedCrossRef
7.
go back to reference Ryf S, Kissinger KV, Spiegel MA, Bornert P, Manning WJ, Boesiger P, Stuber M (2004) Spiral MR myocardial tagging. Magn Reson Med 51:237–242PubMedCrossRef Ryf S, Kissinger KV, Spiegel MA, Bornert P, Manning WJ, Boesiger P, Stuber M (2004) Spiral MR myocardial tagging. Magn Reson Med 51:237–242PubMedCrossRef
8.
9.
go back to reference Zwanenburg JJM, Kuijer JPA, Marcus JT, Heethaar RM (2003) Steady-state free precession with myocardial tagging: CSPAMM in a single breathhold. Magn Reson Med 49:722–730PubMedCrossRef Zwanenburg JJM, Kuijer JPA, Marcus JT, Heethaar RM (2003) Steady-state free precession with myocardial tagging: CSPAMM in a single breathhold. Magn Reson Med 49:722–730PubMedCrossRef
10.
go back to reference Johnson T, Hahn D, Sandstede J (2004) Quantitative analysis of left ventricular wall motion with MRI tagging. Radiologe 44:158–163PubMedCrossRef Johnson T, Hahn D, Sandstede J (2004) Quantitative analysis of left ventricular wall motion with MRI tagging. Radiologe 44:158–163PubMedCrossRef
11.
go back to reference Kramer U, Deshpande V, Fenchel M, Klumpp B, Laub G, Finn JP, Claussen CD, Miller S (2006) Cardiac MR tagging: optimization of sequence parameters and comparison at 1.5 T and 3.0 T in a volunteer study. Rofo 178:515–524PubMed Kramer U, Deshpande V, Fenchel M, Klumpp B, Laub G, Finn JP, Claussen CD, Miller S (2006) Cardiac MR tagging: optimization of sequence parameters and comparison at 1.5 T and 3.0 T in a volunteer study. Rofo 178:515–524PubMed
12.
go back to reference Matter C, Nagel E, Stuber M, Boesiger P, Hess OM (1996) Assessment of systolic and diastolic LV function by MR myocardial tagging. Basic Res Cardiol 91(Suppl 2):23–28PubMedCrossRef Matter C, Nagel E, Stuber M, Boesiger P, Hess OM (1996) Assessment of systolic and diastolic LV function by MR myocardial tagging. Basic Res Cardiol 91(Suppl 2):23–28PubMedCrossRef
13.
go back to reference Stuber M, Scheidegger MB, Fischer SE, Nagel E, Steinemann F, Hess OM, Boesiger P (1999) Alterations in the local myocardial motion pattern in patients suffering from pressure overload due to aortic stenosis. Circulation 100:361–368PubMed Stuber M, Scheidegger MB, Fischer SE, Nagel E, Steinemann F, Hess OM, Boesiger P (1999) Alterations in the local myocardial motion pattern in patients suffering from pressure overload due to aortic stenosis. Circulation 100:361–368PubMed
14.
go back to reference Sandstede JJ, Johnson T, Harre K, Beer M, Hofmann S, Pabst T, Kenn W, Voelker W, Neubauer S, Hahn D (2002) Cardiac systolic rotation and contraction before and after valve replacement for aortic stenosis: a myocardial tagging study using MR imaging. AJR Am J Roentgenol 178:953–958PubMed Sandstede JJ, Johnson T, Harre K, Beer M, Hofmann S, Pabst T, Kenn W, Voelker W, Neubauer S, Hahn D (2002) Cardiac systolic rotation and contraction before and after valve replacement for aortic stenosis: a myocardial tagging study using MR imaging. AJR Am J Roentgenol 178:953–958PubMed
15.
go back to reference Nagel E, Stuber M, Lakatos M, Scheidegger MB, Boesiger P, Hess OM (2000) Cardiac rotation and relaxation after anterolateral myocardial infarction. Coron Artery Dis 11:261–267PubMedCrossRef Nagel E, Stuber M, Lakatos M, Scheidegger MB, Boesiger P, Hess OM (2000) Cardiac rotation and relaxation after anterolateral myocardial infarction. Coron Artery Dis 11:261–267PubMedCrossRef
16.
go back to reference Dornier C, Somsen GA, Ivancevic MK, Osman NF, Didier D, Righetti A, Vallee JP (2004) Comparison between tagged MRI and standard cine MRI for evaluation of left ventricular ejection fraction. Eur Radiol 14:1348–1352PubMedCrossRef Dornier C, Somsen GA, Ivancevic MK, Osman NF, Didier D, Righetti A, Vallee JP (2004) Comparison between tagged MRI and standard cine MRI for evaluation of left ventricular ejection fraction. Eur Radiol 14:1348–1352PubMedCrossRef
17.
go back to reference Kuijpers D (2005) Diagnosis of coronary artery disease with dobutamine-stress MRI. Eur Radiol 15(Suppl 2):B48–B51PubMed Kuijpers D (2005) Diagnosis of coronary artery disease with dobutamine-stress MRI. Eur Radiol 15(Suppl 2):B48–B51PubMed
18.
go back to reference Strach K, Meyer C, Schild H, Sommer T (2006) Cardiac stress MR imaging with dobutamine. Eur Radiol 16:2728–2738PubMedCrossRef Strach K, Meyer C, Schild H, Sommer T (2006) Cardiac stress MR imaging with dobutamine. Eur Radiol 16:2728–2738PubMedCrossRef
19.
go back to reference Marcus JT, Gotte MJW, Van Rossum AC, Kuijer JPA, Heethaar RM, Axel L, Visser CA (1997) Myocardial function in infarcted and remote regions early after infarction in man: assessment by magnetic resonance tagging and strain analysis. Magn Reson Med 38:803–810PubMedCrossRef Marcus JT, Gotte MJW, Van Rossum AC, Kuijer JPA, Heethaar RM, Axel L, Visser CA (1997) Myocardial function in infarcted and remote regions early after infarction in man: assessment by magnetic resonance tagging and strain analysis. Magn Reson Med 38:803–810PubMedCrossRef
20.
go back to reference Kramer CM, Rogers WJ, Theobald TM, Power TP, Petruolo S, Reichek N (1996) Remote noninfarcted region dysfunction soon after first anterior myocardial infarction. A magnetic resonance tagging study. Circulation 94:660–666PubMed Kramer CM, Rogers WJ, Theobald TM, Power TP, Petruolo S, Reichek N (1996) Remote noninfarcted region dysfunction soon after first anterior myocardial infarction. A magnetic resonance tagging study. Circulation 94:660–666PubMed
21.
go back to reference Sandstede J, Machann H, Machann W, Beer M, Johnson T, Harre K, Pabst T, Kenn W, Hahn D (2002) Interindividual-variability of the analysis of regional myocardial wall function after myocardial infarction and revascularization. Rofo 174:1147–1153PubMed Sandstede J, Machann H, Machann W, Beer M, Johnson T, Harre K, Pabst T, Kenn W, Hahn D (2002) Interindividual-variability of the analysis of regional myocardial wall function after myocardial infarction and revascularization. Rofo 174:1147–1153PubMed
22.
go back to reference Osman NF, Kerwin WS, McVeigh ER, Prince JL (1999) Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging. Magn Reson Med 42:1048–1060PubMedCrossRef Osman NF, Kerwin WS, McVeigh ER, Prince JL (1999) Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging. Magn Reson Med 42:1048–1060PubMedCrossRef
23.
go back to reference Ryf S, Spiegel MA, Gerber M, Boesiger P (2002) Myocardial tagging with 3D-CSPAMM. J Magn Reson Imaging 16:320–325PubMedCrossRef Ryf S, Spiegel MA, Gerber M, Boesiger P (2002) Myocardial tagging with 3D-CSPAMM. J Magn Reson Imaging 16:320–325PubMedCrossRef
24.
go back to reference Gotte MJW, van Rossum AC, Twisk JWR, Kuijer JPA, Marcus JT, Visser CA (2001) Quantification of regional contractile function after infarction: strain analysis superior to wall thickening analysis in discriminating infarct from remote myocardium. J Am Coll Cardiol 37:808–817PubMedCrossRef Gotte MJW, van Rossum AC, Twisk JWR, Kuijer JPA, Marcus JT, Visser CA (2001) Quantification of regional contractile function after infarction: strain analysis superior to wall thickening analysis in discriminating infarct from remote myocardium. J Am Coll Cardiol 37:808–817PubMedCrossRef
25.
go back to reference Gutberlet M, Schwinge K, Freyhardt P, Spors B, Grothoff M, Denecke T, Ludemann L, Noeske R, Niendorf T, Felix R (2005) Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging: comparison of 1.5 T vs. 3.0 T. Eur Radiol 15:1586–1597PubMedCrossRef Gutberlet M, Schwinge K, Freyhardt P, Spors B, Grothoff M, Denecke T, Ludemann L, Noeske R, Niendorf T, Felix R (2005) Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging: comparison of 1.5 T vs. 3.0 T. Eur Radiol 15:1586–1597PubMedCrossRef
26.
go back to reference Schar M, Kozerke S, Fischer SE, Boesiger P (2004) Cardiac SSFP imaging at 3 Tesla. Magn Reson Med 51:799–806PubMedCrossRef Schar M, Kozerke S, Fischer SE, Boesiger P (2004) Cardiac SSFP imaging at 3 Tesla. Magn Reson Med 51:799–806PubMedCrossRef
Metadata
Title
Myocardial tagging with steady state free precession techniques and semi-automatic postprocessing—impact on diagnostic value
Authors
Thorsten R. C. Johnson
Nicole Bayrhof
Armin Huber
Joost P. A. Kuijer
Roger Luechinger
Olaf Dietrich
Dietrich Stoevesandt
Dorthe Pedersen
Maximilian F. Reiser
Stefan O. Schoenberg
Publication date
01-09-2007
Publisher
Springer-Verlag
Published in
European Radiology / Issue 9/2007
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-007-0639-5

Other articles of this Issue 9/2007

European Radiology 9/2007 Go to the issue