Skip to main content
Top
Published in: European Radiology 7/2007

01-07-2007 | Computer Tomography

The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT

Authors: Johannes Wessling, Rainer Esseling, Rainer Raupach, Stefanie Fockenberg, Nani Osada, Joachim Gerß, Walter Heindel, Roman Fischbach

Published in: European Radiology | Issue 7/2007

Login to get access

Abstract

The purpose of this study was to assess the effect of dose reduction and the potential of noise reduction filters on image quality and the detection of liver lesions using MSCT. Twenty-nine patients with a total of 40 liver lesions underwent 16-slice CT (120 kV; 180 mAs). Virtual noise was added to CT raw datasets simulating effective mAs levels of 155, 130, 105, 80, 55, 30 and 10 mAs. All datasets were post-processed with an edge-preserving noise-reduction filter (ANR-3D), yielding a total of 15 datasets per patient. Ten radiologists performed independent evaluations of image quality, the presence of liver lesions and diagnostic confidence. Quantitative noise and contrast-to-noise ratios (CNR) were obtained. Superior image quality (P < 0.02), reduction of image noise (P < 0.001) and the increase of lesion-to-liver CNR (P < 0.001) were observed in images processed with the ANR-3D filter. Sensitivity for lesion detection remained unchanged down to 105 mAs (CTDIw 6.6 mGy) without filter and 80 mAs (CTDIw 5.1 mGy) with ANR-3D. Confidence was rated significantly higher for datasets reconstructed with ANR-3D. The use of a noise-reducing, but edge-preserving filter (ANR-3D) is a promising option to reduce further the radiation dose in liver CT.
Literature
1.
go back to reference UNSCEAR 2000 (2000) The United Nations Scientific Committee on the Effects of Atomic Radiation. Health Phys 79(3):314CrossRef UNSCEAR 2000 (2000) The United Nations Scientific Committee on the Effects of Atomic Radiation. Health Phys 79(3):314CrossRef
2.
go back to reference Diederich S, Thomas M, Semik M et al (2004) Screening for early lung cancer with low-dose spiral computed tomography: results of annual follow-up examinations in asymptomatic smokers. Eur Radiol 14(4):691–702PubMedCrossRef Diederich S, Thomas M, Semik M et al (2004) Screening for early lung cancer with low-dose spiral computed tomography: results of annual follow-up examinations in asymptomatic smokers. Eur Radiol 14(4):691–702PubMedCrossRef
3.
go back to reference Wessling J, Fischbach R, Meier N et al (2003) CT colonography: Protocol optimization with multi-detector row CT-Study in an anthropomorphic colon phantom. Radiology 228:753–759PubMedCrossRef Wessling J, Fischbach R, Meier N et al (2003) CT colonography: Protocol optimization with multi-detector row CT-Study in an anthropomorphic colon phantom. Radiology 228:753–759PubMedCrossRef
4.
go back to reference Jensch S, van Gelder RE, Venema HW et al (2006) Effective radiation doses in CT colonography: results of an inventory among research institutions. Eur Radiol 16(5):981–987PubMedCrossRef Jensch S, van Gelder RE, Venema HW et al (2006) Effective radiation doses in CT colonography: results of an inventory among research institutions. Eur Radiol 16(5):981–987PubMedCrossRef
5.
go back to reference Yu L, Pan X, La Riviere P, Pelizzari C, Pan T (2002) A novel algorithm for CT image reconstruction with enhanced noise properties (abstract). Radiology 225(P):255 Yu L, Pan X, La Riviere P, Pelizzari C, Pan T (2002) A novel algorithm for CT image reconstruction with enhanced noise properties (abstract). Radiology 225(P):255
6.
go back to reference Baum U, Anders K, Steinbichler G et al (2004) Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique. Eur Radiol 14(10):1873–1881PubMedCrossRef Baum U, Anders K, Steinbichler G et al (2004) Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique. Eur Radiol 14(10):1873–1881PubMedCrossRef
7.
go back to reference Kalra MK, Maher MM, Sahani DV et al (2003) Low-dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters—pilot study. Radiology 228:251–256PubMedCrossRef Kalra MK, Maher MM, Sahani DV et al (2003) Low-dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters—pilot study. Radiology 228:251–256PubMedCrossRef
8.
go back to reference Frush DP, Slack CC, Hollingsworth CL et al (2002) Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients. AJR Am J Roentgenol 179:1107–1113PubMed Frush DP, Slack CC, Hollingsworth CL et al (2002) Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients. AJR Am J Roentgenol 179:1107–1113PubMed
9.
go back to reference Leidecker C, Fuchs T, Kachelriess M, Schaller S, Kalender W (2002) Comparison of different methods for adding virtual noise to measured raw data in order to estimate the dose reduction potential for clinical protocols in CT (abstract). Radiology 225(P):592 Leidecker C, Fuchs T, Kachelriess M, Schaller S, Kalender W (2002) Comparison of different methods for adding virtual noise to measured raw data in order to estimate the dose reduction potential for clinical protocols in CT (abstract). Radiology 225(P):592
10.
go back to reference Kalender WA, Schmidt B, Zankl M, Schmidt MA (1999) PC program for estimating organdose and effective dose values in computed tomography. Eur Radiol 9:555–562PubMedCrossRef Kalender WA, Schmidt B, Zankl M, Schmidt MA (1999) PC program for estimating organdose and effective dose values in computed tomography. Eur Radiol 9:555–562PubMedCrossRef
11.
go back to reference Wormanns D, Ludwig K, Beyer F et al (2005) Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT. Eur Radiol 15:14–22PubMedCrossRef Wormanns D, Ludwig K, Beyer F et al (2005) Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT. Eur Radiol 15:14–22PubMedCrossRef
12.
go back to reference Cohnen M, Fischer H, Hamacher J et al (2000) CT of the head by use of reduced current and kilovoltage: relationship between image quality and dose reduction. AJNR 21:1654–1660PubMed Cohnen M, Fischer H, Hamacher J et al (2000) CT of the head by use of reduced current and kilovoltage: relationship between image quality and dose reduction. AJNR 21:1654–1660PubMed
13.
go back to reference Iannaccone R, Laghi A, Catalano C et al (2003) Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience. Eur Radiol 13(6):1297–1302PubMed Iannaccone R, Laghi A, Catalano C et al (2003) Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience. Eur Radiol 13(6):1297–1302PubMed
14.
go back to reference Diederich S, Lenzen H, Windmann R et al (1999) Pulmonary nodules: experimental and clinical studies at low-dose CT. Radiology 213:289–298PubMed Diederich S, Lenzen H, Windmann R et al (1999) Pulmonary nodules: experimental and clinical studies at low-dose CT. Radiology 213:289–298PubMed
15.
go back to reference Greess H, Nomayr A, Wolf H et al (2002) Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose). Eur Radiol 12(6):1571–1576PubMedCrossRef Greess H, Nomayr A, Wolf H et al (2002) Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose). Eur Radiol 12(6):1571–1576PubMedCrossRef
16.
17.
go back to reference Itoh S, Koyama S, Ikeda M et al (2001) Further reduction of radiation dose in helical CT for lung cancer screening using small tube current and a newly designed filter. J Thorac Imaging 16:81–88PubMedCrossRef Itoh S, Koyama S, Ikeda M et al (2001) Further reduction of radiation dose in helical CT for lung cancer screening using small tube current and a newly designed filter. J Thorac Imaging 16:81–88PubMedCrossRef
18.
go back to reference Kalra MK, Prasad S, Saini S et al (2002) Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: effect on image quality. Am J Roentgenol 179(5):1101–1106 Kalra MK, Prasad S, Saini S et al (2002) Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: effect on image quality. Am J Roentgenol 179(5):1101–1106
19.
go back to reference Kalra MK, Maher MM, Blake MA et al (2004) Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters. Radiology 232:791–797PubMedCrossRef Kalra MK, Maher MM, Blake MA et al (2004) Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters. Radiology 232:791–797PubMedCrossRef
Metadata
Title
The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT
Authors
Johannes Wessling
Rainer Esseling
Rainer Raupach
Stefanie Fockenberg
Nani Osada
Joachim Gerß
Walter Heindel
Roman Fischbach
Publication date
01-07-2007
Publisher
Springer-Verlag
Published in
European Radiology / Issue 7/2007
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0545-2

Other articles of this Issue 7/2007

European Radiology 7/2007 Go to the issue