01-02-2006 | Technical Developments

Automatic determination of minimal cardiac motion phases for computed tomography imaging: initial experience

Authors: Martin H. K. Hoffmann, Jonathan Lessick, Robert Manzke, Florian T. Schmid, Edward Gershin, Daniel T. Boll, Shmuel Rispler, Andrik J. Aschoff, Michael Grass

Published in: European Radiology | Issue 2/2006

Login to get access

Abstract

Low motion phases for cardiac computed tomography reconstructions are currently detected manually in a user-dependent selection process which is often time consuming and suboptimal. The concept of motion maps was recently introduced to achieve automatic phase selection. This pilot study compared the accuracy of motion-map phase selection to that with manual iterative selection. The study included 20 patients, consisting of one group with low and one with high heart rate. The technique automatically derives a motion strength function between multiple low-resolution reconstructions through the cardiac cycle, with periods of lowest difference between neighboring phases indicating minimal cardiac motion. A high level of agreement was found for phase selection achieved with the motion map approach compared with the manual iterative selection process. The motion maps allowed automated quiescent phase detection of the cardiac cycle in 85% of cases, with best results at low heart rates and for the left coronary artery. They can also provide additional information such as the presence of breathing artifacts. Motion maps show promise as a rapid off-line tool to automatically detect quiescent cardiac phases in a variety of patients.
Literature
1.
go back to reference Heuschmid M, Kuttner A, Flohr T et al (2002) Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: first experiences. Rofo Fortschr Geb Rontgenstrahlen Neuen Bildgeb Verfahr 174:721–724 Heuschmid M, Kuttner A, Flohr T et al (2002) Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: first experiences. Rofo Fortschr Geb Rontgenstrahlen Neuen Bildgeb Verfahr 174:721–724
2.
go back to reference Kopp AF, Kuttner A, Heuschmid M, Schroder S, Ohnesorge B, Claussen CD (2002) Multidetector-row CT cardiac imaging with 4 and 16 slices for coronary CTA and imaging of atherosclerotic plaques. Eur Radiol 12(Suppl 2):S17–S24 Kopp AF, Kuttner A, Heuschmid M, Schroder S, Ohnesorge B, Claussen CD (2002) Multidetector-row CT cardiac imaging with 4 and 16 slices for coronary CTA and imaging of atherosclerotic plaques. Eur Radiol 12(Suppl 2):S17–S24
3.
go back to reference Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054 Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054
4.
go back to reference Rumberger JA (2002) Noninvasive coronary angiography using computed tomography: ready to kick it up another notch? Circulation 106:2036–2038 Rumberger JA (2002) Noninvasive coronary angiography using computed tomography: ready to kick it up another notch? Circulation 106:2036–2038
5.
go back to reference Hoffmann MHK, Shi H, Schmid FT, Gelman H, Brambs H-J, Aschoff AJ (2004) Noninvasive coronary imaging with MDCT in comparison to invasive conventional coronary angiography: a fast-developing technology. AJR Am J Roentgenol 182:601–608 Hoffmann MHK, Shi H, Schmid FT, Gelman H, Brambs H-J, Aschoff AJ (2004) Noninvasive coronary imaging with MDCT in comparison to invasive conventional coronary angiography: a fast-developing technology. AJR Am J Roentgenol 182:601–608
6.
go back to reference Hoffmann MHK, Shi H, Lieberknecht M, Aschoff AJ, Haerer W, Brambs H-J (2003) Sixteen-slice computed tomography and magnetic resonance imaging of calcified pericardium. Circulation 108:48e–49e Hoffmann MHK, Shi H, Lieberknecht M, Aschoff AJ, Haerer W, Brambs H-J (2003) Sixteen-slice computed tomography and magnetic resonance imaging of calcified pericardium. Circulation 108:48e–49e
7.
go back to reference Shi H, Aschoff AJ, Brambs HJ, Hoffmann MH (2004) Multislice CT imaging of anomalous coronary arteries. Eur Radiol 14:2172–2181 Shi H, Aschoff AJ, Brambs HJ, Hoffmann MH (2004) Multislice CT imaging of anomalous coronary arteries. Eur Radiol 14:2172–2181
8.
go back to reference van Ooijen PM, Dorgelo J, Zijlstra F, Oudkerk M (2004) Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT. Eur Radiol 14:2163–2171 van Ooijen PM, Dorgelo J, Zijlstra F, Oudkerk M (2004) Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT. Eur Radiol 14:2163–2171
9.
go back to reference Hamoir XL, Flohr T, Hamoir V et al (2005) Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time. Eur Radiol 15:296–304 Hamoir XL, Flohr T, Hamoir V et al (2005) Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time. Eur Radiol 15:296–304
10.
go back to reference Hong C, Becker CR, Huber A et al (2001) ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220:712–717 Hong C, Becker CR, Huber A et al (2001) ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220:712–717
11.
go back to reference Nieman K, Rensing BJ, van Geuns RJ et al (2002) Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 88:470–474 Nieman K, Rensing BJ, van Geuns RJ et al (2002) Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 88:470–474
12.
go back to reference Herzog C, Abolmaali N, Balzer JO et al (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678 Herzog C, Abolmaali N, Balzer JO et al (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678
13.
go back to reference Achenbach S, Ropers D, Holle J, Muschiol G, Daniel WG, Moshage W (2000) In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology 216:457–463 Achenbach S, Ropers D, Holle J, Muschiol G, Daniel WG, Moshage W (2000) In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology 216:457–463
14.
go back to reference Wang Y, Vidan E, Bergman GW (1999) Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology 213:751–758 Wang Y, Vidan E, Bergman GW (1999) Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology 213:751–758
15.
go back to reference Manzke R, Koehler T, Nielsen T, Hawkes D, Grass M (2004) Automatic phase determination for retrospectively gated cardiac CT. Med Phys 31:3345–3362 Manzke R, Koehler T, Nielsen T, Hawkes D, Grass M (2004) Automatic phase determination for retrospectively gated cardiac CT. Med Phys 31:3345–3362
16.
go back to reference Manzke R, Grass M, Köhler T, Hawkes D (2004) Automatic phase point determination for cardiac CT imaging. SPIE Proc 5370:690–700 Manzke R, Grass M, Köhler T, Hawkes D (2004) Automatic phase point determination for cardiac CT imaging. SPIE Proc 5370:690–700
17.
go back to reference Grass M, Manzke R, Nielsen T et al (2003) Helical cardiac cone beam reconstruction using retrospective ECG gating. Phys Med Biol 48:3069–3084 Grass M, Manzke R, Nielsen T et al (2003) Helical cardiac cone beam reconstruction using retrospective ECG gating. Phys Med Biol 48:3069–3084
18.
go back to reference Manzke R, Grass M, Nielsen T, Shechter G, Hawkes D (2003) Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction. Med Phys 30:3072–3080 Manzke R, Grass M, Nielsen T, Shechter G, Hawkes D (2003) Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction. Med Phys 30:3072–3080
19.
go back to reference Shechter G, Naveh G, Altman A, Proksa R, Grass M (2003) Cardiac image reconstruction on a 16-slice CT scanner using a retrospectively ECG-gated, multi-cycle 3D back-projection algorithm. SPIE Proc 5032:1820–1828 Shechter G, Naveh G, Altman A, Proksa R, Grass M (2003) Cardiac image reconstruction on a 16-slice CT scanner using a retrospectively ECG-gated, multi-cycle 3D back-projection algorithm. SPIE Proc 5032:1820–1828
20.
go back to reference Hoffmann MHK, Shi H, Manzke R et al (2005) Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 234:86–97 Hoffmann MHK, Shi H, Manzke R et al (2005) Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 234:86–97
21.
go back to reference Bland J, Altman D (1995) Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 346:1085–1087 Bland J, Altman D (1995) Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 346:1085–1087
22.
go back to reference Manzke R, Grass M, Hawkes D (2004) Artifact analysis and reconstruction improvement in helical cardiac cone beam CT. IEEE Trans Med Imag 23:1150–1164 Manzke R, Grass M, Hawkes D (2004) Artifact analysis and reconstruction improvement in helical cardiac cone beam CT. IEEE Trans Med Imag 23:1150–1164
23.
go back to reference Kundel HL, Polansky M (2003) Measurement of observer agreement. Radiology 228:303–308 Kundel HL, Polansky M (2003) Measurement of observer agreement. Radiology 228:303–308
24.
go back to reference Applegate KE, Tello R, Ying J (2003) Hypothesis testing III: counts and medians. Radiology 228:603–608 Applegate KE, Tello R, Ying J (2003) Hypothesis testing III: counts and medians. Radiology 228:603–608
25.
go back to reference Zou KH, Tuncali K, Silverman SG (2003) Correlation and simple linear regression. Radiology 227:617–628 Zou KH, Tuncali K, Silverman SG (2003) Correlation and simple linear regression. Radiology 227:617–628
26.
go back to reference Kopp A, Schroeder S, Kuettner A et al (2002) Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients. Eur Heart J 23:1714–1725 Kopp A, Schroeder S, Kuettner A et al (2002) Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients. Eur Heart J 23:1714–1725
27.
go back to reference Cattin P, Dave H, Grunenfelder J, Szekely G, Turina M, Zund G (2004) Trajectory of coronary motion and its significance in robotic motion cancellation. Eur J Cardiothorac Surg 25:786–790 Cattin P, Dave H, Grunenfelder J, Szekely G, Turina M, Zund G (2004) Trajectory of coronary motion and its significance in robotic motion cancellation. Eur J Cardiothorac Surg 25:786–790
28.
go back to reference Saranathan M, Ho V, Hood M, Foo T, Hardy C (2001) Adaptive vessel tracking: automated computation of vessel trajectories for improved efficiency in 2D coronary MR angiography. J Magn Reson Imaging 14:368–373 Saranathan M, Ho V, Hood M, Foo T, Hardy C (2001) Adaptive vessel tracking: automated computation of vessel trajectories for improved efficiency in 2D coronary MR angiography. J Magn Reson Imaging 14:368–373
29.
go back to reference Vembar M, Garcia MJ, Heuscher DJ et al (2003) A dynamic approach to identifying desired physiological phases for cardiac imaging using multislice spiral CT. Med Phys 30:1683–1693 Vembar M, Garcia MJ, Heuscher DJ et al (2003) A dynamic approach to identifying desired physiological phases for cardiac imaging using multislice spiral CT. Med Phys 30:1683–1693
Metadata
Title
Automatic determination of minimal cardiac motion phases for computed tomography imaging: initial experience
Authors
Martin H. K. Hoffmann
Jonathan Lessick
Robert Manzke
Florian T. Schmid
Edward Gershin
Daniel T. Boll
Shmuel Rispler
Andrik J. Aschoff
Michael Grass
Publication date
01-02-2006
Publisher
Springer-Verlag
Published in
European Radiology / Issue 2/2006
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2849-z

Other articles of this Issue 2/2006

European Radiology 2/2006 Go to the issue