Abstract

The aim of this study was to evaluate the inter-observer and intra-observer agreement of the diagnosis of sub-segmental acute pulmonary embolism (PE) in an inpatient population explored by 16 slice multi-detector spiral computed tomography (MDCT). Four hundred consecutive inpatients were referred for MDCT for the clinical suspicion of acute PE. One hundred and seventy seven (44.2%) had a known cardio-respiratory disease at the time of examination. Inter-observer and intra-observer agreements for the diagnosis of acute PE and of sub-segmental acute PE were assessed blind and independently by three experienced readers and by kappa statistics. Seventy-five patients were diagnosed as having acute PE findings (19.5%), and clots were located exclusively within sub-segmental arteries in nine patients (12%). When clots were limited to sub-segmental or more distal branches of the pulmonary arteries, kappa values were found to be moderate (0.56) to very good (0.85) for the diagnosis of sub-segmental acute PE, whereas for the diagnosis of acute PE in the whole population, kappa values ranged from 0.84 to 0.97. Intra-observer agreement was found to be perfect (kappa=1). MDCT is a reproducible technique for the diagnosis of sub-segmental acute PE as well as for acute PE. In this inpatient population, sub-segmental acute PE was not a rare event.
Literature
1.
go back to reference Schibany N, Fleischmann D, Thallinger C et al (2001) Equipment availability and diagnostic strategies for suspected pulmonary embolism in Austria. Eur Radiol 11:2287–2294CrossRefPubMed Schibany N, Fleischmann D, Thallinger C et al (2001) Equipment availability and diagnostic strategies for suspected pulmonary embolism in Austria. Eur Radiol 11:2287–2294CrossRefPubMed
2.
go back to reference Kauczor HU, Heussel CP, Thelen M (1999) Update on diagnostic strategies of pulmonary embolism. Eur Radiol 9:262–275PubMed Kauczor HU, Heussel CP, Thelen M (1999) Update on diagnostic strategies of pulmonary embolism. Eur Radiol 9:262–275PubMed
3.
go back to reference Remy-Jardin M, Remy J, Wattinne L, Giraud F (1992) Central pulmonary thromboembolism: diagnosis with spiral volumetric CT with the single-breath-hold technique—comparison with pulmonary angiography. Radiology 185:381–387PubMed Remy-Jardin M, Remy J, Wattinne L, Giraud F (1992) Central pulmonary thromboembolism: diagnosis with spiral volumetric CT with the single-breath-hold technique—comparison with pulmonary angiography. Radiology 185:381–387PubMed
4.
go back to reference Blachere H, Latrabe V, Montaudon M et al (2000) Pulmonary embolism revealed on helical CT angiography: comparison with ventilation–perfusion radionuclide lung scanning. AJR Am J Roentgenol 174:1041–1047PubMed Blachere H, Latrabe V, Montaudon M et al (2000) Pulmonary embolism revealed on helical CT angiography: comparison with ventilation–perfusion radionuclide lung scanning. AJR Am J Roentgenol 174:1041–1047PubMed
5.
go back to reference Ghaye B, Szapiro D, Mastora I et al (2001) Peripheral pulmonary arteries: how far in the lung does multi-detector row spiral CT allow analysis? Radiology 219:629–636PubMed Ghaye B, Szapiro D, Mastora I et al (2001) Peripheral pulmonary arteries: how far in the lung does multi-detector row spiral CT allow analysis? Radiology 219:629–636PubMed
6.
go back to reference Remy-Jardin M, Baghaie F, Bonnel F, Masson P, Duhamel A, Remy J (2000) Thoracic helical CT: influence of subsecond scan time and thin collimation on evaluation of peripheral pulmonary arteries. Eur Radiol 10:1297–1303CrossRefPubMed Remy-Jardin M, Baghaie F, Bonnel F, Masson P, Duhamel A, Remy J (2000) Thoracic helical CT: influence of subsecond scan time and thin collimation on evaluation of peripheral pulmonary arteries. Eur Radiol 10:1297–1303CrossRefPubMed
7.
go back to reference Schoepf UJ, Kessler MA, Rieger CT et al (2001) Multislice CT imaging of pulmonary embolism. Eur Radiol 11:2278–2286PubMed Schoepf UJ, Kessler MA, Rieger CT et al (2001) Multislice CT imaging of pulmonary embolism. Eur Radiol 11:2278–2286PubMed
8.
go back to reference Schoepf UJ, Holzknecht N, Helmberger TK et al (2002) Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT. Radiology 222:483–490 Schoepf UJ, Holzknecht N, Helmberger TK et al (2002) Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT. Radiology 222:483–490
9.
go back to reference Patel S, Kazerooni EA, Cascade PN (2003) Pulmonary embolism: optimization of small pulmonary artery visualization at multi-detector row CT. Radiology 227:455–460PubMed Patel S, Kazerooni EA, Cascade PN (2003) Pulmonary embolism: optimization of small pulmonary artery visualization at multi-detector row CT. Radiology 227:455–460PubMed
10.
go back to reference Coche E, Pawlak S, Dechambre S, Maldague B (2003) Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction. Eur Radiol 13:815–822PubMed Coche E, Pawlak S, Dechambre S, Maldague B (2003) Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction. Eur Radiol 13:815–822PubMed
11.
go back to reference Remy-Jardin M, Remy J, Baghaie F, Fribourg M, Artaud D, Duhamel A (2000) Clinical value of thin collimation in the diagnostic workup of pulmonary embolism. AJR Am J Roentgenol 175:407–411PubMed Remy-Jardin M, Remy J, Baghaie F, Fribourg M, Artaud D, Duhamel A (2000) Clinical value of thin collimation in the diagnostic workup of pulmonary embolism. AJR Am J Roentgenol 175:407–411PubMed
12.
go back to reference Remy-Jardin M, Remy J, Artaud D, Deschildre F, Duhamel A (1997) Peripheral pulmonary arteries: optimization of the spiral CT acquisition protocol. Radiology 204:157–163PubMed Remy-Jardin M, Remy J, Artaud D, Deschildre F, Duhamel A (1997) Peripheral pulmonary arteries: optimization of the spiral CT acquisition protocol. Radiology 204:157–163PubMed
13.
go back to reference Stein PD, Henry JW (1997) Prevalence of acute pulmonary embolism in central and subsegmental pulmonary arteries and relation to probability interpretation of ventilation/perfusion lung scans. Chest 111:1246–1248PubMed Stein PD, Henry JW (1997) Prevalence of acute pulmonary embolism in central and subsegmental pulmonary arteries and relation to probability interpretation of ventilation/perfusion lung scans. Chest 111:1246–1248PubMed
14.
go back to reference Qanadli SD, Hajjam ME, Mesurolle B et al (2000) Pulmonary embolism detection: prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients. Radiology 217:447–455PubMed Qanadli SD, Hajjam ME, Mesurolle B et al (2000) Pulmonary embolism detection: prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients. Radiology 217:447–455PubMed
15.
go back to reference de Monye W, van Strijen MJ, Huisman MV, Kieft GJ, Pattynama PM (2000) Suspected pulmonary embolism: prevalence and anatomic distribution in 487 consecutive patients. Advances in New Technologies Evaluating the Localisation of Pulmonary Embolism (ANTELOPE) Group. Radiology 215:184–188PubMed de Monye W, van Strijen MJ, Huisman MV, Kieft GJ, Pattynama PM (2000) Suspected pulmonary embolism: prevalence and anatomic distribution in 487 consecutive patients. Advances in New Technologies Evaluating the Localisation of Pulmonary Embolism (ANTELOPE) Group. Radiology 215:184–188PubMed
16.
go back to reference Revel MP, Petrover D, Hernigou A, Lefort C, Meyer G, Frija G (2005) Diagnosing pulmonary embolism with four-detector row helical CT: prospective evaluation of 216 outpatients and inpatients. Radiology 234:265–273PubMed Revel MP, Petrover D, Hernigou A, Lefort C, Meyer G, Frija G (2005) Diagnosing pulmonary embolism with four-detector row helical CT: prospective evaluation of 216 outpatients and inpatients. Radiology 234:265–273PubMed
17.
go back to reference Goodman LR, Lipchik RJ, Kuzo RS, Liu Y, McAuliffe TL, O’Brien DJ (2000) Subsequent pulmonary embolism: risk after a negative helical CT pulmonary angiogram—prospective comparison with scintigraphy. Radiology 215:535–542 Goodman LR, Lipchik RJ, Kuzo RS, Liu Y, McAuliffe TL, O’Brien DJ (2000) Subsequent pulmonary embolism: risk after a negative helical CT pulmonary angiogram—prospective comparison with scintigraphy. Radiology 215:535–542
18.
go back to reference Musset D, Parent F, Meyer G et al (2002) Diagnostic strategy for patients with suspected pulmonary embolism: a prospective multicentre outcome study. Lancet 360:1914–1920 Musset D, Parent F, Meyer G et al (2002) Diagnostic strategy for patients with suspected pulmonary embolism: a prospective multicentre outcome study. Lancet 360:1914–1920
19.
go back to reference van Strijen MJ, de Monye W, Kieft GJ et al (2003) Diagnosis of pulmonary embolism with spiral CT as a second procedure following scintigraphy. Eur Radiol 13:1501–1507PubMed van Strijen MJ, de Monye W, Kieft GJ et al (2003) Diagnosis of pulmonary embolism with spiral CT as a second procedure following scintigraphy. Eur Radiol 13:1501–1507PubMed
20.
go back to reference Perrier A, Bounameaux H (1998) Ultrasonography of leg veins in patients suspected of having pulmonary embolism. Ann Intern Med 128:243; author reply 244–245 Perrier A, Bounameaux H (1998) Ultrasonography of leg veins in patients suspected of having pulmonary embolism. Ann Intern Med 128:243; author reply 244–245
21.
go back to reference Perrier A, Roy PM, Sanchez O et al (2005) Multidetector-row computed tomography in suspected pulmonary embolism. N Engl J Med 352:1760–1768PubMed Perrier A, Roy PM, Sanchez O et al (2005) Multidetector-row computed tomography in suspected pulmonary embolism. N Engl J Med 352:1760–1768PubMed
22.
go back to reference Oser RF, Zuckerman DA, Gutierrez FR, Brink JA (1996) Anatomic distribution of pulmonary emboli at pulmonary angiography: implications for cross-sectional imaging. Radiology 199:31–35PubMed Oser RF, Zuckerman DA, Gutierrez FR, Brink JA (1996) Anatomic distribution of pulmonary emboli at pulmonary angiography: implications for cross-sectional imaging. Radiology 199:31–35PubMed
23.
go back to reference Moser KM (1990) Venous thromboembolism. Am Rev Respir Dis 141:235–249PubMed Moser KM (1990) Venous thromboembolism. Am Rev Respir Dis 141:235–249PubMed
24.
go back to reference Directive Européenne EUR 16262 (1997) Quality criteria for computed tomography Directive Européenne EUR 16262 (1997) Quality criteria for computed tomography
25.
go back to reference Boyden E (1955) Segmental anatomy of the lungs. McGraw-Hill, New York Boyden E (1955) Segmental anatomy of the lungs. McGraw-Hill, New York
26.
go back to reference Altmann D (1992) Practical statistics for medical research. Chapman & Hall, London Altmann D (1992) Practical statistics for medical research. Chapman & Hall, London
27.
go back to reference Drucker EA, Rivitz SM, Shepard JA et al (1998) Acute pulmonary embolism: assessment of helical CT for diagnosis. Radiology 209:235–241PubMed Drucker EA, Rivitz SM, Shepard JA et al (1998) Acute pulmonary embolism: assessment of helical CT for diagnosis. Radiology 209:235–241PubMed
28.
go back to reference Remy-Jardin M, Remy J, Deschildre F et al (1996) Diagnosis of pulmonary embolism with spiral CT: comparison with pulmonary angiography and scintigraphy. Radiology 200:699–706PubMed Remy-Jardin M, Remy J, Deschildre F et al (1996) Diagnosis of pulmonary embolism with spiral CT: comparison with pulmonary angiography and scintigraphy. Radiology 200:699–706PubMed
29.
go back to reference Teigen CL, Maus TP, Sheedy PF II et al (1995) Pulmonary embolism: diagnosis with contrast-enhanced electron-beam CT and comparison with pulmonary angiography. Radiology 194:313–319PubMed Teigen CL, Maus TP, Sheedy PF II et al (1995) Pulmonary embolism: diagnosis with contrast-enhanced electron-beam CT and comparison with pulmonary angiography. Radiology 194:313–319PubMed
30.
go back to reference Chartrand-Lefebvre C, Howarth N, Lucidarme O et al (1999) Contrast-enhanced helical CT for pulmonary embolism detection: inter- and intraobserver agreement among radiologists with variable experience. AJR Am J Roentgenol 172:107–112PubMed Chartrand-Lefebvre C, Howarth N, Lucidarme O et al (1999) Contrast-enhanced helical CT for pulmonary embolism detection: inter- and intraobserver agreement among radiologists with variable experience. AJR Am J Roentgenol 172:107–112PubMed
31.
go back to reference Ruiz Y, Caballero P, Caniego JL et al (2003) Prospective comparison of helical CT with angiography in pulmonary embolism: global and selective vascular territory analysis. Interobserver agreement. Eur Radiol 13:823–829PubMed Ruiz Y, Caballero P, Caniego JL et al (2003) Prospective comparison of helical CT with angiography in pulmonary embolism: global and selective vascular territory analysis. Interobserver agreement. Eur Radiol 13:823–829PubMed
32.
go back to reference Diffin DC, Leyendecker JR, Johnson SP, Zucker RJ, Grebe PJ (1998) Effect of anatomic distribution of pulmonary emboli on interobserver agreement in the interpretation of pulmonary angiography. AJR Am J Roentgenol 171:1085–1089PubMed Diffin DC, Leyendecker JR, Johnson SP, Zucker RJ, Grebe PJ (1998) Effect of anatomic distribution of pulmonary emboli on interobserver agreement in the interpretation of pulmonary angiography. AJR Am J Roentgenol 171:1085–1089PubMed
33.
go back to reference Baile EM, King GG, Muller NL et al (2000) Spiral computed tomography is comparable to angiography for the diagnosis of pulmonary embolism. Am J Respir Crit Care Med 161:1010–1015PubMed Baile EM, King GG, Muller NL et al (2000) Spiral computed tomography is comparable to angiography for the diagnosis of pulmonary embolism. Am J Respir Crit Care Med 161:1010–1015PubMed
34.
go back to reference Schoepf UJ, Costello P (2004) Images in cardiovascular medicine. Isolated subsegmental pulmonary embolus diagnosed by multidetector-row computed tomography. Circulation 109:e220–e221PubMed Schoepf UJ, Costello P (2004) Images in cardiovascular medicine. Isolated subsegmental pulmonary embolus diagnosed by multidetector-row computed tomography. Circulation 109:e220–e221PubMed
35.
go back to reference Henry JW, Relyea B, Stein PD (1995) Continuing risk of thromboemboli among patients with normal pulmonary angiograms. Chest 107:1375–1378PubMed Henry JW, Relyea B, Stein PD (1995) Continuing risk of thromboemboli among patients with normal pulmonary angiograms. Chest 107:1375–1378PubMed
36.
go back to reference Tetalman MR, Hoffer PB, Heck LL, Kunzmann A, Gottschalk A (1973) Perfusion lung scan in normal volunteers. Radiology 106:593–594PubMed Tetalman MR, Hoffer PB, Heck LL, Kunzmann A, Gottschalk A (1973) Perfusion lung scan in normal volunteers. Radiology 106:593–594PubMed
37.
go back to reference Raptopoulos V, Boiselle PM (2001) Multi-detector row spiral CT pulmonary angiography: comparison with single-detector row spiral CT. Radiology 221:606–613PubMed Raptopoulos V, Boiselle PM (2001) Multi-detector row spiral CT pulmonary angiography: comparison with single-detector row spiral CT. Radiology 221:606–613PubMed
38.
go back to reference Garg K, Welsh CH, Feyerabend AJ et al (1998) Pulmonary embolism: diagnosis with spiral CT and ventilation–perfusion scanning—correlation with pulmonary angiographic results or clinical outcome. Radiology 208:201–208PubMed Garg K, Welsh CH, Feyerabend AJ et al (1998) Pulmonary embolism: diagnosis with spiral CT and ventilation–perfusion scanning—correlation with pulmonary angiographic results or clinical outcome. Radiology 208:201–208PubMed
39.
go back to reference Goodman LR, Curtin JJ, Mewissen MW et al (1995) Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: helical CT versus angiography. AJR Am J Roentgenol 164:1369–1374PubMed Goodman LR, Curtin JJ, Mewissen MW et al (1995) Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: helical CT versus angiography. AJR Am J Roentgenol 164:1369–1374PubMed
40.
go back to reference Coche E, Verschuren F, Keyeux A et al (2003) Diagnosis of acute pulmonary embolism in outpatients: comparison of thin-collimation multi-detector row spiral CT and planar ventilation–perfusion scintigraphy. Radiology 229:757–765PubMed Coche E, Verschuren F, Keyeux A et al (2003) Diagnosis of acute pulmonary embolism in outpatients: comparison of thin-collimation multi-detector row spiral CT and planar ventilation–perfusion scintigraphy. Radiology 229:757–765PubMed
41.
go back to reference Wildberger JE, Mahnken AH, Das M, Kuttner A, Lell M, Gunther RW (2005) CT imaging in acute pulmonary embolism: diagnostic strategies. Eur Radiol 15:919–929PubMed Wildberger JE, Mahnken AH, Das M, Kuttner A, Lell M, Gunther RW (2005) CT imaging in acute pulmonary embolism: diagnostic strategies. Eur Radiol 15:919–929PubMed
Metadata
Title
Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism
Authors
S. Brunot
O. Corneloup
V. Latrabe
M. Montaudon
F. Laurent
Publication date
01-10-2005
Publisher
Springer-Verlag
Published in
European Radiology / Issue 10/2005
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2844-4

Other articles of this Issue 10/2005

European Radiology 10/2005 Go to the issue

Calendar of Events

Calendar of Events 15/10