Skip to main content
Top
Published in: European Radiology 3/2004

01-03-2004 | Cardiac

Steady-state free precession sequences in myocardial first-pass perfusion MR imaging: comparison with TurboFLASH imaging

Authors: Peter Hunold, Stefan Maderwald, Holger Eggebrecht, Florian M. Vogt, Jörg Barkhausen

Published in: European Radiology | Issue 3/2004

Login to get access

Abstract

The aim of this study was to compare the image quality of a saturation-recovery gradient-recalled echo (GRE; TurboFLASH) and a saturation-recovery SSFP (SR-TrueFISP) sequence for myocardial first-pass perfusion MRI. Eight patients with chronic myocardial infarction and 8 volunteers were examined with a TurboFLASH (TR 2.1 ms, TE 1 ms, FA 8°) and a SR-TrueFISP sequence (TR 2.1 ms, TE 0.9 ms, FA, 50°) on a 1.5 T scanner. During injection of 0.05 mmol/kg BW Gd-DTPA at 4 ml/s, three short axis slices (8 mm) of the left ventricle (LV) were simultaneously scanned during breath-hold. Maximum signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) between infarcted and normal myocardium, and percentage signal intensity change (PSIC) were measured within the LV lumen and in four regions of the LV myocardium for the three slices separately. For the LV lumen, SR-TrueFISP was superior in SNR and PSIC (factor 3.2 and 1.6, respectively). Mean maximum SNR, PSIC, and CNR during peak enhancement in the LV myocardium were higher for SR-TrueFISP compared with TurboFLASH (factor 2.4, 1.25, and 1.24, respectively). The SNR was higher in the septal portion of the ventricle than in anterior/posterior and lateral regions. The SR-TrueFISP provides higher SNR and improves image quality compared with TurboFLASH in first-pass myocardial perfusion MRI.
Literature
1.
go back to reference Gibbons RJ, Abrams J, Chatterjee K, Daley J, Deedwania PC, Douglas JS, Ferguson TB Jr, Fihn SD, Fraker TD Jr, Gardin JM, O’Rourke RA, Pasternak RC, Williams SV, Alpert JS, Antman EM, Hiratzka LF, Fuster V, Faxon DP, Gregoratos G, Jacobs AK, Smith SC Jr (2003) ACC/AHA 2002 guideline update for the management of patients with chronic stable angina—summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on the Management of Patients With Chronic Stable Angina). Circulation 107:149–158CrossRefPubMed Gibbons RJ, Abrams J, Chatterjee K, Daley J, Deedwania PC, Douglas JS, Ferguson TB Jr, Fihn SD, Fraker TD Jr, Gardin JM, O’Rourke RA, Pasternak RC, Williams SV, Alpert JS, Antman EM, Hiratzka LF, Fuster V, Faxon DP, Gregoratos G, Jacobs AK, Smith SC Jr (2003) ACC/AHA 2002 guideline update for the management of patients with chronic stable angina—summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on the Management of Patients With Chronic Stable Angina). Circulation 107:149–158CrossRefPubMed
2.
go back to reference Schwaiger M (1994) Myocardial perfusion imaging with PET. J Nucl Med 35:693–698PubMed Schwaiger M (1994) Myocardial perfusion imaging with PET. J Nucl Med 35:693–698PubMed
3.
go back to reference Go RT, Marwick TH, MacIntyre WJ, Saha GB, Neumann DR, Underwood DA, Simpfendorfer CC (1990) A prospective comparison of rubidium-82 PET and thallium-201 SPECT myocardial perfusion imaging utilizing a single dipyridamole stress in the diagnosis of coronary artery disease. J Nucl Med 31:1899–1905PubMed Go RT, Marwick TH, MacIntyre WJ, Saha GB, Neumann DR, Underwood DA, Simpfendorfer CC (1990) A prospective comparison of rubidium-82 PET and thallium-201 SPECT myocardial perfusion imaging utilizing a single dipyridamole stress in the diagnosis of coronary artery disease. J Nucl Med 31:1899–1905PubMed
4.
go back to reference Demer LL, Gould KL, Goldstein RA, Kirkeeide RL, Mullani NA, Smalling RW, Nishikawa A, Merhige ME (1989) Assessment of coronary artery disease severity by positron emission tomography: comparison with quantitative arteriography in 193 patients. Circulation 79:825–835PubMed Demer LL, Gould KL, Goldstein RA, Kirkeeide RL, Mullani NA, Smalling RW, Nishikawa A, Merhige ME (1989) Assessment of coronary artery disease severity by positron emission tomography: comparison with quantitative arteriography in 193 patients. Circulation 79:825–835PubMed
5.
go back to reference Manning WJ, Atkinson DJ, Grossman W, Paulin S, Edelman RR (1991) First-pass nuclear magnetic resonance imaging studies using gadolinium-DTPA in patients with coronary artery disease. J Am Coll Cardiol 18:959–965PubMed Manning WJ, Atkinson DJ, Grossman W, Paulin S, Edelman RR (1991) First-pass nuclear magnetic resonance imaging studies using gadolinium-DTPA in patients with coronary artery disease. J Am Coll Cardiol 18:959–965PubMed
6.
go back to reference Wilke NM, Jerosch-Herold M, Zenovich A, Stillman AE (1999) Magnetic resonance first-pass myocardial perfusion imaging: clinical validation and future applications. J Magn Reson Imaging 10:676–685CrossRefPubMed Wilke NM, Jerosch-Herold M, Zenovich A, Stillman AE (1999) Magnetic resonance first-pass myocardial perfusion imaging: clinical validation and future applications. J Magn Reson Imaging 10:676–685CrossRefPubMed
7.
go back to reference Keijer JT, van Rossum AC, van Eenige MJ, Bax JJ, Visser FC, Teule JJ, Visser CA (2000) Magnetic resonance imaging of regional myocardial perfusion in patients with single-vessel coronary artery disease: quantitative comparison with (201)Thallium-SPECT and coronary angiography. J Magn Reson Imaging 11:607–615CrossRefPubMed Keijer JT, van Rossum AC, van Eenige MJ, Bax JJ, Visser FC, Teule JJ, Visser CA (2000) Magnetic resonance imaging of regional myocardial perfusion in patients with single-vessel coronary artery disease: quantitative comparison with (201)Thallium-SPECT and coronary angiography. J Magn Reson Imaging 11:607–615CrossRefPubMed
8.
go back to reference Lauerma K, Virtanen KS, Sipila LM, Hekali P, Aronen HJ (1997) Multislice MRI in assessment of myocardial perfusion in patients with single-vessel proximal left anterior descending coronary artery disease before and after revascularization. Circulation 96:2859–2867PubMed Lauerma K, Virtanen KS, Sipila LM, Hekali P, Aronen HJ (1997) Multislice MRI in assessment of myocardial perfusion in patients with single-vessel proximal left anterior descending coronary artery disease before and after revascularization. Circulation 96:2859–2867PubMed
9.
go back to reference Panting JR, Gatehouse PD, Yang GZ, Jerosch-Herold M, Wilke N, Firmin DN, Pennell DJ (2001) Echo-planar magnetic resonance myocardial perfusion imaging: parametric map analysis and comparison with thallium SPECT. J Magn Reson Imaging 13:192–200CrossRefPubMed Panting JR, Gatehouse PD, Yang GZ, Jerosch-Herold M, Wilke N, Firmin DN, Pennell DJ (2001) Echo-planar magnetic resonance myocardial perfusion imaging: parametric map analysis and comparison with thallium SPECT. J Magn Reson Imaging 13:192–200CrossRefPubMed
10.
go back to reference Kraitchman DL, Chin BB, Heldman AW, Solaiyappan M, Bluemke DA (2002) MRI detection of myocardial perfusion defects due to coronary artery stenosis with MS-325. J Magn Reson Imaging 15:149–158CrossRefPubMed Kraitchman DL, Chin BB, Heldman AW, Solaiyappan M, Bluemke DA (2002) MRI detection of myocardial perfusion defects due to coronary artery stenosis with MS-325. J Magn Reson Imaging 15:149–158CrossRefPubMed
11.
go back to reference Schmitt M, Mohrs OK, Petersen SE, Kreitner KF, Voigtlander T, Wittlinger T, Horstick G, Ziegler S, Meyer J, Thelen M, Schreiber WG (2002) Evaluation of myocardial perfusion reserve in patients with CAD using contrast-enhanced MRI: a comparison between semiquantitative and quantitative methods. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:187–195 [in German]CrossRefPubMed Schmitt M, Mohrs OK, Petersen SE, Kreitner KF, Voigtlander T, Wittlinger T, Horstick G, Ziegler S, Meyer J, Thelen M, Schreiber WG (2002) Evaluation of myocardial perfusion reserve in patients with CAD using contrast-enhanced MRI: a comparison between semiquantitative and quantitative methods. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:187–195 [in German]CrossRefPubMed
12.
go back to reference Wintersperger BJ, Penzkofer HV, Knez A, Weber J, Reiser MF (1999) Multislice MR perfusion imaging and regional myocardial function analysis: complimentary findings in chronic myocardial ischemia. Int J Card Imaging 15:425–434CrossRefPubMed Wintersperger BJ, Penzkofer HV, Knez A, Weber J, Reiser MF (1999) Multislice MR perfusion imaging and regional myocardial function analysis: complimentary findings in chronic myocardial ischemia. Int J Card Imaging 15:425–434CrossRefPubMed
13.
go back to reference Plein S, Bloomer TN, Ridgway JP, Jones TR, Bainbridge GJ, Sivananthan MU (2001) Steady-state free precession magnetic resonance imaging of the heart: comparison with segmented k-space gradient-echo imaging. J Magn Reson Imaging 14:230–236CrossRefPubMed Plein S, Bloomer TN, Ridgway JP, Jones TR, Bainbridge GJ, Sivananthan MU (2001) Steady-state free precession magnetic resonance imaging of the heart: comparison with segmented k-space gradient-echo imaging. J Magn Reson Imaging 14:230–236CrossRefPubMed
14.
go back to reference Carr JC, Simonetti O, Bundy J, Li D, Pereles S, Finn JP (2001) Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 219:828–834PubMed Carr JC, Simonetti O, Bundy J, Li D, Pereles S, Finn JP (2001) Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 219:828–834PubMed
15.
go back to reference Barkhausen J, Hunold P, Jochims M, Eggebrecht H, Sabin GV, Erbel R, Debatin JF (2002) Comparison of gradient-echo and steady-state free precession sequences for 3D-navigator MR angiography of coronary arteries. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:725–730 [in German]CrossRefPubMed Barkhausen J, Hunold P, Jochims M, Eggebrecht H, Sabin GV, Erbel R, Debatin JF (2002) Comparison of gradient-echo and steady-state free precession sequences for 3D-navigator MR angiography of coronary arteries. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:725–730 [in German]CrossRefPubMed
16.
go back to reference Hunold P, Brandt-Mainz K, Freudenberg L, Vogt FM, Neumann T, Knipp S, Barkhausen J (2002) Evaluation of myocardial viability with contrast-enhanced magnetic resonance imaging: comparison of the late enhancement technique with positron emission tomography. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:867–873 [in German]CrossRefPubMed Hunold P, Brandt-Mainz K, Freudenberg L, Vogt FM, Neumann T, Knipp S, Barkhausen J (2002) Evaluation of myocardial viability with contrast-enhanced magnetic resonance imaging: comparison of the late enhancement technique with positron emission tomography. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:867–873 [in German]CrossRefPubMed
17.
go back to reference Firbank MJ, Coulthard A, Harrison RM, Williams ED (1999) A comparison of two methods for measuring the signal-to-noise ratio on MR images. Phys Med Biol 44:N261–N264CrossRefPubMed Firbank MJ, Coulthard A, Harrison RM, Williams ED (1999) A comparison of two methods for measuring the signal-to-noise ratio on MR images. Phys Med Biol 44:N261–N264CrossRefPubMed
18.
go back to reference Schreiber WG, Schmitt M, Kalden P, Horstick G, Gumbrich T, Petersen S, Mohrs O, Kreitner KF, Voigtlander T, Thelen M (2001) Perfusion MR imaging of the heart with TrueFISP. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:205–210 [in German]CrossRefPubMed Schreiber WG, Schmitt M, Kalden P, Horstick G, Gumbrich T, Petersen S, Mohrs O, Kreitner KF, Voigtlander T, Thelen M (2001) Perfusion MR imaging of the heart with TrueFISP. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:205–210 [in German]CrossRefPubMed
19.
go back to reference Schreiber WG, Schmitt M, Kalden P, Mohrs OK, Kreitner KF, Thelen M (2002) Dynamic contrast-enhanced myocardial perfusion imaging using saturation-prepared TrueFISP. J Magn Reson Imaging 16:641–652CrossRefPubMed Schreiber WG, Schmitt M, Kalden P, Mohrs OK, Kreitner KF, Thelen M (2002) Dynamic contrast-enhanced myocardial perfusion imaging using saturation-prepared TrueFISP. J Magn Reson Imaging 16:641–652CrossRefPubMed
20.
go back to reference Muhling OM, Dickson ME, Zenovich A, Huang Y, Wilson BV, Wilson RF, Anand IS, Seethamraju RT, Jerosch-Herold M, Wilke NM (2001) Quantitative magnetic resonance first-pass perfusion analysis: inter- and intraobserver agreement. J Cardiovasc Magn Reson 3:247–256CrossRefPubMed Muhling OM, Dickson ME, Zenovich A, Huang Y, Wilson BV, Wilson RF, Anand IS, Seethamraju RT, Jerosch-Herold M, Wilke NM (2001) Quantitative magnetic resonance first-pass perfusion analysis: inter- and intraobserver agreement. J Cardiovasc Magn Reson 3:247–256CrossRefPubMed
21.
go back to reference Schwitter J, Nanz D, Kneifel S, Bertschinger K, Buchi M, Knusel PR, Marincek B, Luscher TF, Schulthess GK von (2001) Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: a comparison with positron emission tomography and coronary angiography. Circulation 103:2230–2235PubMed Schwitter J, Nanz D, Kneifel S, Bertschinger K, Buchi M, Knusel PR, Marincek B, Luscher TF, Schulthess GK von (2001) Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: a comparison with positron emission tomography and coronary angiography. Circulation 103:2230–2235PubMed
22.
go back to reference Zur Y, Stokar S, Bendel P (1988) An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magn Reson Med 6:175–193PubMed Zur Y, Stokar S, Bendel P (1988) An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magn Reson Med 6:175–193PubMed
23.
go back to reference Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: true fast imaging with steady-state precession vs fast low-angle shot cine MR imaging—feasibility study. Radiology 219:264–269PubMed Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: true fast imaging with steady-state precession vs fast low-angle shot cine MR imaging—feasibility study. Radiology 219:264–269PubMed
24.
go back to reference Foo TK, Ho VB, Marcos HB, Hood MN, Choyke PL (2002) MR angiography using steady-state free precession. Magn Reson Med 48:699–706CrossRefPubMed Foo TK, Ho VB, Marcos HB, Hood MN, Choyke PL (2002) MR angiography using steady-state free precession. Magn Reson Med 48:699–706CrossRefPubMed
25.
go back to reference Spuentrup E, Bornert P, Botnar RM, Groen JP, Manning WJ, Stuber M (2002) Navigator-gated free-breathing three-dimensional balanced fast field echo (TrueFISP) coronary magnetic resonance angiography. Invest Radiol 37:637–642CrossRefPubMed Spuentrup E, Bornert P, Botnar RM, Groen JP, Manning WJ, Stuber M (2002) Navigator-gated free-breathing three-dimensional balanced fast field echo (TrueFISP) coronary magnetic resonance angiography. Invest Radiol 37:637–642CrossRefPubMed
26.
go back to reference Overall WR, Nishimura DG, Hu BS (2002) Fast phase-contrast velocity measurement in the steady state. Magn Reson Med 48:890–898CrossRefPubMed Overall WR, Nishimura DG, Hu BS (2002) Fast phase-contrast velocity measurement in the steady state. Magn Reson Med 48:890–898CrossRefPubMed
27.
go back to reference Klocke FJ, Simonetti OP, Judd RM, Kim RJ, Harris KR, Hedjbeli S, Fieno DS, Miller S, Chen V, Parker MA (2001) Limits of detection of regional differences in vasodilated flow in viable myocardium by first-pass magnetic resonance perfusion imaging. Circulation 104:2412–2416PubMed Klocke FJ, Simonetti OP, Judd RM, Kim RJ, Harris KR, Hedjbeli S, Fieno DS, Miller S, Chen V, Parker MA (2001) Limits of detection of regional differences in vasodilated flow in viable myocardium by first-pass magnetic resonance perfusion imaging. Circulation 104:2412–2416PubMed
Metadata
Title
Steady-state free precession sequences in myocardial first-pass perfusion MR imaging: comparison with TurboFLASH imaging
Authors
Peter Hunold
Stefan Maderwald
Holger Eggebrecht
Florian M. Vogt
Jörg Barkhausen
Publication date
01-03-2004
Publisher
Springer-Verlag
Published in
European Radiology / Issue 3/2004
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-2176-1

Other articles of this Issue 3/2004

European Radiology 3/2004 Go to the issue

Letter to the Editor

Letter to the Editor

Letter to the Editor

Reply