Skip to main content
Top
Published in: European Radiology 8/2003

01-08-2003 | Cardiac

Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating

Authors: Tobias F. Jakobs, Bernd J. Wintersperger, Peter Herzog, Thomas Flohr, Christoph Suess, Andreas Knez, Maximilian F. Reiser, Christoph R. Becker

Published in: European Radiology | Issue 8/2003

Login to get access

Abstract

The aim of this study was to reduce radiation exposure in multislice CT (MSCT) coronary artery calcium screening using different tube settings, and to determinate its impact on the detection and quantification of coronary artery calcification. Forty-eight patients underwent routine MSCT coronary artery calcium scoring (Somatom VolumeZoom, Siemens, Forchheim, Germany) with retrospective ECG-gated data acquisition. Scanning was performed with a 4×2.5-mm collimation. In each patient data acquisition was performed twice using tube settings of 120 kVp with 133 mAs (protocol 1) and of 80 kVp with 300 mAs (protocol 2). Together with the 80-kVp protocol additional online ECG-related tube current modulation (ECG pulsing) was used. Three-millimeter overlapping slices (increment 1.5 mm) were calculated for each data set. Semi-automated calcium quantification was performed calculating absolute Ca-hydroxylapatite mass. In addition to patient examinations, the radiation exposure for both protocols was evaluated using computed tomography dose index (CTDI) phantom measurements. Protocol 2 showed a significantly lower patient radiation exposure than protocol 1 (0.72 vs 2.04 mSv; p<0.0001). The CTDI phantom measurements revealed a 65% reduction of radiation dose. Calcium scoring results of both protocols showed a high correlation (r=0.99; p<0.0001) for absolute Ca-Hydroxylapatite mass measurements. Using 80-kVp protocols patient radiation exposure can be significantly reduced in MSCT coronary artery calcium screening without affecting the detection and quantification of coronary artery calcification; therefore, this technique should be used with retrospective ECG-gated cardiac CT examinations in patients with regular sinus rhythm.
Literature
1.
go back to reference Friedewald ST, Wyngaarden JB, Smith LH (eds) (1988) Cecil's textbook of medicine, 18th edn. Saunders, Philadelphia, pp 179–183 Friedewald ST, Wyngaarden JB, Smith LH (eds) (1988) Cecil's textbook of medicine, 18th edn. Saunders, Philadelphia, pp 179–183
2.
go back to reference Tunstall-Pedoe H, Kuulasmaa K, Mahonen M, Tolonen H, Ruokokoski E, Amouyel P (1999) Contribution of trends in survival and coronary-event rates to changes in coronary heart disease mortality: 10-year results from 37 WHO MONICA project populations. Monitoring trends and determinants in cardiovascular disease. Lancet 353:1547–1557PubMed Tunstall-Pedoe H, Kuulasmaa K, Mahonen M, Tolonen H, Ruokokoski E, Amouyel P (1999) Contribution of trends in survival and coronary-event rates to changes in coronary heart disease mortality: 10-year results from 37 WHO MONICA project populations. Monitoring trends and determinants in cardiovascular disease. Lancet 353:1547–1557PubMed
3.
go back to reference O'Malley P, Taylor A, Gibbons R et al. (1999) Rationale and design of the prospective army coronary calcium (PACC) study: utility of electron-beam computed tomography as a screening test for coronary artery disease and as an intervention for risk factor modification amoung young, asymptomatic, active-duty United States Army personal. Am Heart J 137:932–941PubMed O'Malley P, Taylor A, Gibbons R et al. (1999) Rationale and design of the prospective army coronary calcium (PACC) study: utility of electron-beam computed tomography as a screening test for coronary artery disease and as an intervention for risk factor modification amoung young, asymptomatic, active-duty United States Army personal. Am Heart J 137:932–941PubMed
4.
go back to reference National Institutes of Health (2000) NHLBI launches 10-year study on early detection of heart disease. National Heart, Lung and Blood Institute, http://www.nhlbi.nih.gov/new/press/sep14–00.htm National Institutes of Health (2000) NHLBI launches 10-year study on early detection of heart disease. National Heart, Lung and Blood Institute, http://​www.​nhlbi.​nih.​gov/​new/​press/​sep14–00.htm
5.
go back to reference Laudon DA, Vukov LF, Breen JF, Rumberger JA, Wollan PC, Sheedy PF (1999) Use of electron-beam computed tomography in the evaluation of chest pain patients in the emergency department. Ann Emerg Med 33:15–21PubMed Laudon DA, Vukov LF, Breen JF, Rumberger JA, Wollan PC, Sheedy PF (1999) Use of electron-beam computed tomography in the evaluation of chest pain patients in the emergency department. Ann Emerg Med 33:15–21PubMed
6.
go back to reference Wexler L, Brundage B, Crouse J et al. (1996) Coronary artery calcification: pathophysiology, epidemiology, imaging methods and clinical implications. A statement for health professionals from the American Heart Association Writing Group. Circulation 94:1175–1192PubMed Wexler L, Brundage B, Crouse J et al. (1996) Coronary artery calcification: pathophysiology, epidemiology, imaging methods and clinical implications. A statement for health professionals from the American Heart Association Writing Group. Circulation 94:1175–1192PubMed
7.
go back to reference Callister TQ, Raggi P, Cooli B, Lippolis NJ, Russo DJ (1998) Effect of HMG-CoA reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography. N Engl J Med 339:1972–1978PubMed Callister TQ, Raggi P, Cooli B, Lippolis NJ, Russo DJ (1998) Effect of HMG-CoA reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography. N Engl J Med 339:1972–1978PubMed
8.
go back to reference Becker C, Jakobs T, Aydemir S et al. (2000) Helical and single-slice conventional versus electron beam CT for quantification of coronary artery calcification. AJR 174:543–547PubMed Becker C, Jakobs T, Aydemir S et al. (2000) Helical and single-slice conventional versus electron beam CT for quantification of coronary artery calcification. AJR 174:543–547PubMed
9.
go back to reference Becker C, Kleffel T, Crispin A et al. (2001) Coronary artery calcium measurement: agreement of multirow detector and electron beam CT. AJR 176:1295–1298 Becker C, Kleffel T, Crispin A et al. (2001) Coronary artery calcium measurement: agreement of multirow detector and electron beam CT. AJR 176:1295–1298
10.
go back to reference Ohnesorge B, Flohr T, Becker CR et al. (2000) Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 217:564–571PubMed Ohnesorge B, Flohr T, Becker CR et al. (2000) Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 217:564–571PubMed
11.
go back to reference Becker C, Schätzl M, Feist H et al. (1999) Assessment of the effective dose for routine protocols in conventional CT, electron beam CT and coronary angiography. RoFo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 170:90–104 Becker C, Schätzl M, Feist H et al. (1999) Assessment of the effective dose for routine protocols in conventional CT, electron beam CT and coronary angiography. RoFo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 170:90–104
12.
go back to reference Ohnesorge B, Flohr T, Fischbach R, Kopp AF, Knez A, Schröder S, Schöpf UJ, Crispin A, Klotz E, Reiser MF, Becker CR (2002) Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. Eur Radiol 12:1532–1540CrossRefPubMed Ohnesorge B, Flohr T, Fischbach R, Kopp AF, Knez A, Schröder S, Schöpf UJ, Crispin A, Klotz E, Reiser MF, Becker CR (2002) Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. Eur Radiol 12:1532–1540CrossRefPubMed
13.
go back to reference Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217:430–435PubMed Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217:430–435PubMed
14.
go back to reference Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086PubMed Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086PubMed
15.
go back to reference Ohnesorge B, Flohr T, Becker CR, Kopp AF, Knez A, Reiser MF (2000) Dose evaluation and dose reduction strategies for ECG-gated multislice spiral CT of the heart. Radiology 217:487PubMed Ohnesorge B, Flohr T, Becker CR, Kopp AF, Knez A, Reiser MF (2000) Dose evaluation and dose reduction strategies for ECG-gated multislice spiral CT of the heart. Radiology 217:487PubMed
16.
go back to reference Bongartz G, Golding SJ, Jurik AG, Leonardi M, van Meerten EvP, Geleijns J, Jessen KA, Panzer W, Shrimpton PC, Tosi G (1999) European guidelines on quality criteria for computed tomography. Report EUR 16262 EN, http://www.drs.dk/guidelines/ct/quality/default.htm, ISBN 92-828-7478-8 Bongartz G, Golding SJ, Jurik AG, Leonardi M, van Meerten EvP, Geleijns J, Jessen KA, Panzer W, Shrimpton PC, Tosi G (1999) European guidelines on quality criteria for computed tomography. Report EUR 16262 EN, http://​www.​drs.​dk/​guidelines/​ct/​quality/​default.​htm, ISBN 92-828-7478-8
17.
go back to reference Becker CR, Schoepf UJ, Reiser MF (2003) Coronary artery calcium scoring: medicine and politics. Eur Radiol 13:445–447PubMed Becker CR, Schoepf UJ, Reiser MF (2003) Coronary artery calcium scoring: medicine and politics. Eur Radiol 13:445–447PubMed
18.
go back to reference Hong C, Bae KT et al. (2002) Coronary artery calcium measurement with multi-detector row CT: in vitro assessment of effect of radiation dose. Radiology 225:901–906PubMed Hong C, Bae KT et al. (2002) Coronary artery calcium measurement with multi-detector row CT: in vitro assessment of effect of radiation dose. Radiology 225:901–906PubMed
19.
go back to reference Ulzheimer S, Kalender WA (2003) Assessment of calcium scoring performance in cardiac computed tomography. Eur Radiol 13:484–497PubMed Ulzheimer S, Kalender WA (2003) Assessment of calcium scoring performance in cardiac computed tomography. Eur Radiol 13:484–497PubMed
20.
go back to reference Klingenbeck K, Schaller S, Flohr T, Ohnesorge B, Kopp AF, Baum U (1999) Subsecond multislice computed tomography: basics and applications. Eur J Radiol 31:110–124PubMed Klingenbeck K, Schaller S, Flohr T, Ohnesorge B, Kopp AF, Baum U (1999) Subsecond multislice computed tomography: basics and applications. Eur J Radiol 31:110–124PubMed
Metadata
Title
Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating
Authors
Tobias F. Jakobs
Bernd J. Wintersperger
Peter Herzog
Thomas Flohr
Christoph Suess
Andreas Knez
Maximilian F. Reiser
Christoph R. Becker
Publication date
01-08-2003
Publisher
Springer-Verlag
Published in
European Radiology / Issue 8/2003
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-1895-7

Other articles of this Issue 8/2003

European Radiology 8/2003 Go to the issue

Gastrointestinal

Colorectal tuberculosis