Skip to main content
Top
Published in: CardioVascular and Interventional Radiology 2/2012

01-04-2012 | Clinical Investigation

Perforation of the IVC: Rule Rather Than Exception After Longer Indwelling Times for the Günther Tulip and Celect Retrievable Filters

Authors: Jeremy C. Durack, Antonio C. Westphalen, Stephanie Kekulawela, Shiv B. Bhanu, David E. Avrin, Roy L. Gordon, Robert K. Kerlan

Published in: CardioVascular and Interventional Radiology | Issue 2/2012

Login to get access

Abstract

Purpose

This study was designed to assess the incidence, magnitude, and impact upon retrievability of vena caval perforation by Günther Tulip and Celect conical inferior vena cava (IVC) filters on computed tomographic (CT) imaging.

Methods

Günther Tulip and Celect IVC filters placed between July 2007 and May 2009 were identified from medical records. Of 272 IVC filters placed, 50 (23 Günther Tulip, 46%; 27 Celect, 54%) were retrospectively assessed on follow-up abdominal CT scans performed for reasons unrelated to the filter. Computed tomography scans were examined for evidence of filter perforation through the vena caval wall, tilt, or pericaval tissue injury. Procedure records were reviewed to determine whether IVC filter retrieval was attempted and successful.

Results

Perforation of at least one filter component through the IVC was observed in 43 of 50 (86%) filters on CT scans obtained between 1 and 880 days after filter placement. All filters imaged after 71 days showed some degree of vena caval perforation, often as a progressive process. Filter tilt was seen in 20 of 50 (40%) filters, and all tilted filters also demonstrated vena caval perforation. Transjugular removal was attempted in 12 of 50 (24%) filters and was successful in 11 of 12 (92%).

Conclusions

Longer indwelling times usually result in vena caval perforation by retrievable Günther Tulip and Celect IVC filters. Although infrequently reported in the literature, clinical sequelae from IVC filter components breaching the vena cava can be significant. We advocate filter retrieval as early as clinically indicated and increased attention to the appearance of IVC filters on all follow-up imaging studies.
Literature
1.
go back to reference Stein PD, Kayali F, Olson RE (2004) Twenty-one-year trends in the use of inferior vena cava filters. Arch Intern Med 164(14):1541–1545PubMedCrossRef Stein PD, Kayali F, Olson RE (2004) Twenty-one-year trends in the use of inferior vena cava filters. Arch Intern Med 164(14):1541–1545PubMedCrossRef
2.
go back to reference Jaff MR, Goldhaber SZ, Tapson VF (2005) High utilization rate of vena cava filters in deep vein thrombosis. Thromb Haemost 93:1117–1119PubMed Jaff MR, Goldhaber SZ, Tapson VF (2005) High utilization rate of vena cava filters in deep vein thrombosis. Thromb Haemost 93:1117–1119PubMed
3.
go back to reference Athanasoulis CA, Kaufman JA, Halpern EF et al (2000) Inferior vena cava filters: review of a 26-year single-center clinical experience. Radiology 216:54–66PubMed Athanasoulis CA, Kaufman JA, Halpern EF et al (2000) Inferior vena cava filters: review of a 26-year single-center clinical experience. Radiology 216:54–66PubMed
4.
go back to reference Ray CE, Mitchell E, Zipser S et al (2006) Outcomes with retrievable inferior vena cava filters: a multicenter study. J Vasc Interv Radiol 17:1595–1604PubMedCrossRef Ray CE, Mitchell E, Zipser S et al (2006) Outcomes with retrievable inferior vena cava filters: a multicenter study. J Vasc Interv Radiol 17:1595–1604PubMedCrossRef
5.
go back to reference Karmy-Jones R, Jurkovich GJ, Velmahos GC et al (2007) Practice patterns and outcomes of retrievable vena cava filters in trauma patients: an AAST multicenter study. J Trauma 62:17–24PubMedCrossRef Karmy-Jones R, Jurkovich GJ, Velmahos GC et al (2007) Practice patterns and outcomes of retrievable vena cava filters in trauma patients: an AAST multicenter study. J Trauma 62:17–24PubMedCrossRef
6.
go back to reference White RH, Zhou H, Kim J et al (2000) A population-based study of the effectiveness of inferior vena cava filter use among patients with venous thromboembolism. Arch Intern Med 160:2033–2041PubMedCrossRef White RH, Zhou H, Kim J et al (2000) A population-based study of the effectiveness of inferior vena cava filter use among patients with venous thromboembolism. Arch Intern Med 160:2033–2041PubMedCrossRef
7.
go back to reference Girard P, Stern J, Parent F (2002) Medical literature and vena cava filters: so far so weak. Chest 122(3):963–967PubMedCrossRef Girard P, Stern J, Parent F (2002) Medical literature and vena cava filters: so far so weak. Chest 122(3):963–967PubMedCrossRef
8.
go back to reference Ray CE, Kaufman JA (1996) Complications of inferior vena cava filters. Abdom Imaging 21(4):368–374PubMedCrossRef Ray CE, Kaufman JA (1996) Complications of inferior vena cava filters. Abdom Imaging 21(4):368–374PubMedCrossRef
9.
go back to reference Greenfield L, Proctor M (2000) Filter complications and their management. Semin Vasc Surg 13:213–216PubMed Greenfield L, Proctor M (2000) Filter complications and their management. Semin Vasc Surg 13:213–216PubMed
10.
go back to reference Sadaf A, Rasuli P, Olivier A et al (2007) Significant caval penetration by the Celect inferior vena cava filter: attributable to filter design? J Vasc Interv Radiol 18(11):1447–1450PubMedCrossRef Sadaf A, Rasuli P, Olivier A et al (2007) Significant caval penetration by the Celect inferior vena cava filter: attributable to filter design? J Vasc Interv Radiol 18(11):1447–1450PubMedCrossRef
11.
go back to reference Dardik A, Campbell KA, Yeo CJ et al (1997) Vena cava filter ensnarement and delayed migration: an unusual series of cases. J Vasc Surg 26:869–874PubMedCrossRef Dardik A, Campbell KA, Yeo CJ et al (1997) Vena cava filter ensnarement and delayed migration: an unusual series of cases. J Vasc Surg 26:869–874PubMedCrossRef
12.
go back to reference Koenker R, Hallock K (2001) Quantile regression: an introduction. J Econ Perspect 15:143–156CrossRef Koenker R, Hallock K (2001) Quantile regression: an introduction. J Econ Perspect 15:143–156CrossRef
13.
go back to reference Ota S, Yamada N, Tsuji A et al (2008) The Günther-Tulip retrievable IVC filter: clinical experience in 118 consecutive patients. Circ J 72:287–292PubMedCrossRef Ota S, Yamada N, Tsuji A et al (2008) The Günther-Tulip retrievable IVC filter: clinical experience in 118 consecutive patients. Circ J 72:287–292PubMedCrossRef
14.
go back to reference Sangwaiya MJ, Marentis TC, Walker TG et al (2009) Safety and effectiveness of the Celect inferior vena cava filter: preliminary results. J Vasc Interv Radiol 20:1188–1192PubMedCrossRef Sangwaiya MJ, Marentis TC, Walker TG et al (2009) Safety and effectiveness of the Celect inferior vena cava filter: preliminary results. J Vasc Interv Radiol 20:1188–1192PubMedCrossRef
15.
go back to reference Smouse HB, Van Alstine WG, Mack S et al (2009) Deployment performance and retrievability of the Cook Celect vena cava filter. J Vasc Interv Radiol 20:375–383PubMedCrossRef Smouse HB, Van Alstine WG, Mack S et al (2009) Deployment performance and retrievability of the Cook Celect vena cava filter. J Vasc Interv Radiol 20:375–383PubMedCrossRef
16.
go back to reference Chintalapudi UB, Gutierrez OH, Azodo MV (1997) Greenfield filter caval perforation causing an aortic mural thrombus and femoral artery occlusion. Cathet Cardiovasc Diagn 41:53–55PubMedCrossRef Chintalapudi UB, Gutierrez OH, Azodo MV (1997) Greenfield filter caval perforation causing an aortic mural thrombus and femoral artery occlusion. Cathet Cardiovasc Diagn 41:53–55PubMedCrossRef
17.
go back to reference Goldman HB, Hanna K, Dmochowski RR (1996) Ureteral injury secondary to an inferior vena caval filter. J Urol 156:1763PubMedCrossRef Goldman HB, Hanna K, Dmochowski RR (1996) Ureteral injury secondary to an inferior vena caval filter. J Urol 156:1763PubMedCrossRef
18.
go back to reference Sarkar MR, Lemminger FM (1997) An unusual case of upper gastrointestinal hemorrhage—perforation of a vena cava filter into the duodenum. Vasa 26:305–307PubMed Sarkar MR, Lemminger FM (1997) An unusual case of upper gastrointestinal hemorrhage—perforation of a vena cava filter into the duodenum. Vasa 26:305–307PubMed
19.
go back to reference Woodward EB, Farber A, Wagner WH et al (2002) Delayed retroperitoneal arterial hemorrhage after inferior vena cava (IVC) filter insertion: case report and literature review of caval perforations by IVC filters. Ann Vasc Surg 16:193–196PubMedCrossRef Woodward EB, Farber A, Wagner WH et al (2002) Delayed retroperitoneal arterial hemorrhage after inferior vena cava (IVC) filter insertion: case report and literature review of caval perforations by IVC filters. Ann Vasc Surg 16:193–196PubMedCrossRef
20.
go back to reference Turba UC, Arslan B, Meuse M et al (2010) Gunter tulip filter retrieval experience: predictors of successful retrieval. Cardiovasc Intervent Radiol 33:732–738PubMedCrossRef Turba UC, Arslan B, Meuse M et al (2010) Gunter tulip filter retrieval experience: predictors of successful retrieval. Cardiovasc Intervent Radiol 33:732–738PubMedCrossRef
21.
go back to reference Smouse HB, Rosenthal D, Ha VT et al (2009) Long-term retrieval success rate profile for the Günther Tulip vena cava filter. J Vasc Interv Radiol 20:871–877PubMedCrossRef Smouse HB, Rosenthal D, Ha VT et al (2009) Long-term retrieval success rate profile for the Günther Tulip vena cava filter. J Vasc Interv Radiol 20:871–877PubMedCrossRef
22.
go back to reference Mission JF, Kerlan RK Jr, Tan JH et al (2010) Rates and predictors of plans for inferior vena cava filter retrieval in hospitalized patients. J Gen Intern Med 25(4):321–325PubMedCrossRef Mission JF, Kerlan RK Jr, Tan JH et al (2010) Rates and predictors of plans for inferior vena cava filter retrieval in hospitalized patients. J Gen Intern Med 25(4):321–325PubMedCrossRef
23.
go back to reference Greenfield LJ (2006) The PREPIC Study Group. Eight-year follow-up of patients with permanent vena cava filters in the prevention of pulmonary embolism: the PREPIC (Prevention du Risque d’Embolie Pulmonaire par Interruption Cave) Randomized Study. Perspect Vasc Surg Endovasc Ther 18:187–188PubMedCrossRef Greenfield LJ (2006) The PREPIC Study Group. Eight-year follow-up of patients with permanent vena cava filters in the prevention of pulmonary embolism: the PREPIC (Prevention du Risque d’Embolie Pulmonaire par Interruption Cave) Randomized Study. Perspect Vasc Surg Endovasc Ther 18:187–188PubMedCrossRef
24.
go back to reference Kuo WT, Cupp JS, Louie JD et al (2010) Retrieval of permanently-embedded IVC filters and description of the laser-assisted sheath technique: radiographic-histopathologic correlation. J Vasc Interv Radiol Suppl 21(2):4CrossRef Kuo WT, Cupp JS, Louie JD et al (2010) Retrieval of permanently-embedded IVC filters and description of the laser-assisted sheath technique: radiographic-histopathologic correlation. J Vasc Interv Radiol Suppl 21(2):4CrossRef
25.
go back to reference Stavropoulos SW, Dixon RG, Burke CT et al (2008) Embedded inferior vena cava filter removal: use of endobronchial forceps. J Vasc Interv Radiol 19:1297–1301PubMedCrossRef Stavropoulos SW, Dixon RG, Burke CT et al (2008) Embedded inferior vena cava filter removal: use of endobronchial forceps. J Vasc Interv Radiol 19:1297–1301PubMedCrossRef
26.
go back to reference Rubenstein L, Chun AK, Chew M et al (2007) Loop-snare technique for difficult inferior vena cava filter retrievals. J Vasc Interv Radiol 18:1315–1318PubMedCrossRef Rubenstein L, Chun AK, Chew M et al (2007) Loop-snare technique for difficult inferior vena cava filter retrievals. J Vasc Interv Radiol 18:1315–1318PubMedCrossRef
27.
go back to reference Kuo WT, Bostaph AS, Loh CT et al (2006) Retrieval of trapped Günther Tulip inferior vena cava filters: snare-over-guide wire loop technique. J Vasc Interv Radiol 17:1845–1849PubMedCrossRef Kuo WT, Bostaph AS, Loh CT et al (2006) Retrieval of trapped Günther Tulip inferior vena cava filters: snare-over-guide wire loop technique. J Vasc Interv Radiol 17:1845–1849PubMedCrossRef
Metadata
Title
Perforation of the IVC: Rule Rather Than Exception After Longer Indwelling Times for the Günther Tulip and Celect Retrievable Filters
Authors
Jeremy C. Durack
Antonio C. Westphalen
Stephanie Kekulawela
Shiv B. Bhanu
David E. Avrin
Roy L. Gordon
Robert K. Kerlan
Publication date
01-04-2012
Publisher
Springer-Verlag
Published in
CardioVascular and Interventional Radiology / Issue 2/2012
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-011-0151-9

Other articles of this Issue 2/2012

CardioVascular and Interventional Radiology 2/2012 Go to the issue

Obituary

In Memoriam