Skip to main content
Top
Published in: CardioVascular and Interventional Radiology 4/2009

01-07-2009 | Clinical Investigation

Evaluation of Angiographic and Technical Aspects of Carotid Stenting with Diffusion-Weighted Magnetic Resonance Imaging

Authors: Stella Blasel, Elke Hattingen, Joachim Berkefeld, Wiebke Kurre, Gerald Morawe, Friedhelm Zanella, Richard Du Mesnil de Rochemont

Published in: CardioVascular and Interventional Radiology | Issue 4/2009

Login to get access

Abstract

The detection of clinically silent ischemic lesions on postprocedural diffusion-weighted magnetic resonance images has become a preferred method for the description of embolic risks. The purpose of this single-center study was to evaluate whether diffusion-weighted imaging (DWI) could determine material related or technical risk factors of filter-protected carotid stenting. Eighty-four patients with symptomatic severe (≥60%) carotid artery stenoses received filter-protected carotid stenting. Standard DWI (b = 1000) was performed within 48 h before and after carotid stenting. The occurrence and load of new postinterventional DWI lesions were assessed. Multivariate analysis was performed to determine risk factors associated with DWI lesions, with emphasis on technical factors such as use of different access devices (guiding catheter method vs. long carotid sheath method), type of stent (open-cell nitinol stent vs. closed-cell Wallstent), and protective device (filters with 80-μm vs. 110–120-μm pore size). Markers for generalized atherosclerosis and for degree and site of stenosis were assessed to allow comparison of adequate risk profiles. Access, protective device, and stent type were not significantly associated with new embolic DWI lesions when we compared patients with equivalent risk profiles (long carotid sheath method 48% [11 of 23] vs. guiding catheter method 44% [27 of 61], Wallstent 47% [15 of 32] vs. nitinol stent 44% [23 of 52], and small pore size filter 61% [11 of 18] vs. large pore size filter 41% [27 of 66]). Single-center DWI studies with a moderate number of cases are inadequate for proper assessment of the embolic risk of technical- or material-related risk factors in carotid stenting. Larger multicenter studies with more cases are needed.
Literature
1.
go back to reference Cotroneo AR, Iezzi R (2007) Cutting balloon angioplasty (CBA) versus conventional balloon angioplasty (PTA) in the pre-dilatation of carotid artery stenosis: our preliminary experience. Cardiovasc Intervent Radiol 30:1210–1217PubMedCrossRef Cotroneo AR, Iezzi R (2007) Cutting balloon angioplasty (CBA) versus conventional balloon angioplasty (PTA) in the pre-dilatation of carotid artery stenosis: our preliminary experience. Cardiovasc Intervent Radiol 30:1210–1217PubMedCrossRef
2.
go back to reference Diethrich EB, Ndiaye M, Reid DB (1996) Stenting in the carotid artery: initial experience in 110 patients. J Endovasc Surg 3:42–62PubMedCrossRef Diethrich EB, Ndiaye M, Reid DB (1996) Stenting in the carotid artery: initial experience in 110 patients. J Endovasc Surg 3:42–62PubMedCrossRef
3.
go back to reference Kastrup A, Groschel K, Schulz JB et al (2005) Clinical predictors of transient ischemic attack, stroke, or death within 30 days of carotid angioplasty and stenting. Stroke 36:787–791PubMedCrossRef Kastrup A, Groschel K, Schulz JB et al (2005) Clinical predictors of transient ischemic attack, stroke, or death within 30 days of carotid angioplasty and stenting. Stroke 36:787–791PubMedCrossRef
4.
go back to reference Mathias K, Jaeger H, Henning S (1999) Technique of stent angioplasty in atherosclerotic disease of the internal carotid artery. Carotid Intervent 1:41–46 Mathias K, Jaeger H, Henning S (1999) Technique of stent angioplasty in atherosclerotic disease of the internal carotid artery. Carotid Intervent 1:41–46
5.
go back to reference Safian RD, Bresnahan JF, Jaff MR et al (2006) Protected carotid stenting in high-risk patients with severe carotid artery stenosis. J Am Coll Cardiol 47:2384–2389PubMedCrossRef Safian RD, Bresnahan JF, Jaff MR et al (2006) Protected carotid stenting in high-risk patients with severe carotid artery stenosis. J Am Coll Cardiol 47:2384–2389PubMedCrossRef
6.
go back to reference White CJ, Iyer SS, Hopkins L et al (2006) Carotid stenting with distal protection in high surgical risk patients: the BEACH trial 30 day results. Catheter Cardiovasc Interv 67:503–512PubMedCrossRef White CJ, Iyer SS, Hopkins L et al (2006) Carotid stenting with distal protection in high surgical risk patients: the BEACH trial 30 day results. Catheter Cardiovasc Interv 67:503–512PubMedCrossRef
7.
go back to reference Wholey MH, Al-Mubarek N, Wholey MH (2003) Updated review of the global carotid artery stent registry. Catheter Cardiovasc Interv 60:259–266PubMedCrossRef Wholey MH, Al-Mubarek N, Wholey MH (2003) Updated review of the global carotid artery stent registry. Catheter Cardiovasc Interv 60:259–266PubMedCrossRef
8.
go back to reference Wholey MH, Wholey M, Mathias K et al (2000) Global experience in cervical carotid artery stent placement. Catheter Cardiovasc Interv 50:160–167PubMedCrossRef Wholey MH, Wholey M, Mathias K et al (2000) Global experience in cervical carotid artery stent placement. Catheter Cardiovasc Interv 50:160–167PubMedCrossRef
9.
go back to reference Wholey MH, Wholey MH, Jarmolowski CR et al (1997) Endovascular stents for carotid artery occlusive disease. J Endovasc Surg 4:326–338PubMedCrossRef Wholey MH, Wholey MH, Jarmolowski CR et al (1997) Endovascular stents for carotid artery occlusive disease. J Endovasc Surg 4:326–338PubMedCrossRef
10.
go back to reference Yadav JS, Roubin GS, Iyer S et al (1997) Elective stenting of the extracranial carotid arteries. Circulation 95:376–381PubMed Yadav JS, Roubin GS, Iyer S et al (1997) Elective stenting of the extracranial carotid arteries. Circulation 95:376–381PubMed
12.
go back to reference Naylor AR (2007) Where next after SPACE and EVA-3S: “the good, the bad and the ugly!”. Eur J Vasc Endovasc Surg 33:44–47PubMedCrossRef Naylor AR (2007) Where next after SPACE and EVA-3S: “the good, the bad and the ugly!”. Eur J Vasc Endovasc Surg 33:44–47PubMedCrossRef
13.
14.
go back to reference Beauchamp NJ, Barker PB, Wang PY et al (1999) Imaging of acute cerebral ischemia. Radiology 212:307–324PubMed Beauchamp NJ, Barker PB, Wang PY et al (1999) Imaging of acute cerebral ischemia. Radiology 212:307–324PubMed
15.
go back to reference Beauchamp NJ, Ulug AM, Passe TJ et al (1998) MR diffusion imaging in stroke: review and controversies. Radiographics 18:1269–1283PubMed Beauchamp NJ, Ulug AM, Passe TJ et al (1998) MR diffusion imaging in stroke: review and controversies. Radiographics 18:1269–1283PubMed
16.
go back to reference Bendszus M, Koltzenburg M, Burger R et al (1999) Silent embolism in diagnostic cerebral angiography and neurointerventional procedures: a prospective study. Lancet 354:1594–1597PubMedCrossRef Bendszus M, Koltzenburg M, Burger R et al (1999) Silent embolism in diagnostic cerebral angiography and neurointerventional procedures: a prospective study. Lancet 354:1594–1597PubMedCrossRef
17.
go back to reference Burdette JH, Elster AD, Ricci PE (1999) Acute cerebral infarction: quantification of spin-density and T2 shine-through phenomena on diffusion-weighted MR images. Radiology 212:333–339PubMed Burdette JH, Elster AD, Ricci PE (1999) Acute cerebral infarction: quantification of spin-density and T2 shine-through phenomena on diffusion-weighted MR images. Radiology 212:333–339PubMed
18.
go back to reference Burdette JH, Ricci PE, Petitti N et al (1998) Cerebral infarction: time course of signal intensity changes on diffusion-weighted MR images. Am J Roentgenol 171:791–795 Burdette JH, Ricci PE, Petitti N et al (1998) Cerebral infarction: time course of signal intensity changes on diffusion-weighted MR images. Am J Roentgenol 171:791–795
19.
go back to reference Crisostomo RA, Garcia MM, Tong DC (2003) Detection of diffusion-weighted MRI abnormalities in patients with transient ischemic attack: correlation with clinical characteristics. Stroke 34:932–937PubMedCrossRef Crisostomo RA, Garcia MM, Tong DC (2003) Detection of diffusion-weighted MRI abnormalities in patients with transient ischemic attack: correlation with clinical characteristics. Stroke 34:932–937PubMedCrossRef
20.
go back to reference de Rochemont R, Schneider S, Yan B et al (2006) Diffusion-weighted MR imaging lesions after filter-protected stenting of high-grade symptomatic carotid artery stenoses. Am J Neuroradiol 27:1321–1325 de Rochemont R, Schneider S, Yan B et al (2006) Diffusion-weighted MR imaging lesions after filter-protected stenting of high-grade symptomatic carotid artery stenoses. Am J Neuroradiol 27:1321–1325
21.
go back to reference Ghorab K, Macian F, Adoukounou T et al (2008) Carotid angioplasty stenting revisited: clinical and radiological (MRI) outcome. Cerebrovasc Dis 25:21–25PubMedCrossRef Ghorab K, Macian F, Adoukounou T et al (2008) Carotid angioplasty stenting revisited: clinical and radiological (MRI) outcome. Cerebrovasc Dis 25:21–25PubMedCrossRef
22.
go back to reference Jaeger H, Mathias K, Drescher R et al (2001) Clinical results of cerebral protection with a filter device during stent implantation of the carotid artery. Cardiovasc Intervent Radiol 24:249–256PubMedCrossRef Jaeger H, Mathias K, Drescher R et al (2001) Clinical results of cerebral protection with a filter device during stent implantation of the carotid artery. Cardiovasc Intervent Radiol 24:249–256PubMedCrossRef
23.
go back to reference Kidwell CS, Alger JR, Di Salle F et al (1999) Diffusion MRI in patients with transient ischemic attacks. Stroke 30:1174–1180PubMed Kidwell CS, Alger JR, Di Salle F et al (1999) Diffusion MRI in patients with transient ischemic attacks. Stroke 30:1174–1180PubMed
24.
go back to reference Lovblad KO, Laubach HJ, Baird AE et al (1998) Clinical experience with diffusion-weighted MR in patients with acute stroke. AJNR Am J Neuroradiol 19:1061–1066PubMed Lovblad KO, Laubach HJ, Baird AE et al (1998) Clinical experience with diffusion-weighted MR in patients with acute stroke. AJNR Am J Neuroradiol 19:1061–1066PubMed
25.
go back to reference Rovira A, Rovira-Gols A, Pedraza S et al (2002) Diffusion-weighted MR imaging in the acute phase of transient ischemic attacks. Am J Neuroradiol 23:77–83PubMed Rovira A, Rovira-Gols A, Pedraza S et al (2002) Diffusion-weighted MR imaging in the acute phase of transient ischemic attacks. Am J Neuroradiol 23:77–83PubMed
26.
go back to reference van Everdingen KJ, van der Grond J, Kappelle LJ et al (1998) Diffusion-weighted magnetic resonance imaging in acute stroke. Stroke 29:1783–1790PubMed van Everdingen KJ, van der Grond J, Kappelle LJ et al (1998) Diffusion-weighted magnetic resonance imaging in acute stroke. Stroke 29:1783–1790PubMed
27.
go back to reference Collaborators North American Symptomatic Carotid Endarterectomy Trial (1991) Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. N Engl J Med 325:445–453 Collaborators North American Symptomatic Carotid Endarterectomy Trial (1991) Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. N Engl J Med 325:445–453
28.
go back to reference Cosottini M, Michelassi MC, Puglioli M et al (2005) Silent cerebral ischemia detected with diffusion-weighted imaging in patients treated with protected and unprotected carotid artery stenting. Stroke 36:2389–2393PubMedCrossRef Cosottini M, Michelassi MC, Puglioli M et al (2005) Silent cerebral ischemia detected with diffusion-weighted imaging in patients treated with protected and unprotected carotid artery stenting. Stroke 36:2389–2393PubMedCrossRef
29.
go back to reference Kastrup A, Groschel K, Krapf H et al (2003) Early outcome of carotid angioplasty and stenting with and without cerebral protection devices: a systematic review of the literature. Stroke 34:813–819PubMedCrossRef Kastrup A, Groschel K, Krapf H et al (2003) Early outcome of carotid angioplasty and stenting with and without cerebral protection devices: a systematic review of the literature. Stroke 34:813–819PubMedCrossRef
30.
go back to reference Zahn R, Mark B, Niedermaier N et al (2004) Embolic protection devices for carotid artery stenting: better results than stenting without protection? Eur Heart J 25:1550–1558PubMedCrossRef Zahn R, Mark B, Niedermaier N et al (2004) Embolic protection devices for carotid artery stenting: better results than stenting without protection? Eur Heart J 25:1550–1558PubMedCrossRef
31.
go back to reference Hauth EA, Drescher R, Jansen C et al (2006) Complications and follow-up after unprotected carotid artery stenting. Cardiovasc Intervent Radiol 29:511–518PubMedCrossRef Hauth EA, Drescher R, Jansen C et al (2006) Complications and follow-up after unprotected carotid artery stenting. Cardiovasc Intervent Radiol 29:511–518PubMedCrossRef
32.
go back to reference Kastrup A, Gröschel K, Nägele T et al (2008) Effects of age and symptom status on silent ischemic lesions after carotid stenting with and without the use of distal filter devices. AJNR Am J Neuroradiol 29:608–612PubMedCrossRef Kastrup A, Gröschel K, Nägele T et al (2008) Effects of age and symptom status on silent ischemic lesions after carotid stenting with and without the use of distal filter devices. AJNR Am J Neuroradiol 29:608–612PubMedCrossRef
33.
go back to reference Hobson RW, Howard VJ, Roubin GS et al (2004) Carotid artery stenting is associated with increased complications in octogenarians: 30-day stroke and death rates in the CREST lead-in phase. J Vasc Surg 40:1106–1111PubMedCrossRef Hobson RW, Howard VJ, Roubin GS et al (2004) Carotid artery stenting is associated with increased complications in octogenarians: 30-day stroke and death rates in the CREST lead-in phase. J Vasc Surg 40:1106–1111PubMedCrossRef
34.
go back to reference Stanziale SF, Marone LK, Boules TN et al (2006) Carotid artery stenting in octogenarians is associated with increased adverse outcomes. J Vasc Surg 43:297–304PubMedCrossRef Stanziale SF, Marone LK, Boules TN et al (2006) Carotid artery stenting in octogenarians is associated with increased adverse outcomes. J Vasc Surg 43:297–304PubMedCrossRef
35.
go back to reference Sayeed S, Stanziale SF, Wholey MH et al (2008) Angiographic lesion characteristics can predict adverse outcomes after carotid artery stenting. J Vasc Surg 47:81–87PubMedCrossRef Sayeed S, Stanziale SF, Wholey MH et al (2008) Angiographic lesion characteristics can predict adverse outcomes after carotid artery stenting. J Vasc Surg 47:81–87PubMedCrossRef
36.
go back to reference Ringleb PA, Allenberg J, Bruckmann H et al (2006) 30 day results from the SPACE trial of stent-protected angioplasty versus carotid endarterectomy in symptomatic patients: a randomised non-inferiority trial. Lancet 368:1239–1247PubMedCrossRef Ringleb PA, Allenberg J, Bruckmann H et al (2006) 30 day results from the SPACE trial of stent-protected angioplasty versus carotid endarterectomy in symptomatic patients: a randomised non-inferiority trial. Lancet 368:1239–1247PubMedCrossRef
Metadata
Title
Evaluation of Angiographic and Technical Aspects of Carotid Stenting with Diffusion-Weighted Magnetic Resonance Imaging
Authors
Stella Blasel
Elke Hattingen
Joachim Berkefeld
Wiebke Kurre
Gerald Morawe
Friedhelm Zanella
Richard Du Mesnil de Rochemont
Publication date
01-07-2009
Publisher
Springer-Verlag
Published in
CardioVascular and Interventional Radiology / Issue 4/2009
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-009-9526-6

Other articles of this Issue 4/2009

CardioVascular and Interventional Radiology 4/2009 Go to the issue