Skip to main content
Top
Published in: World Journal of Surgery 1/2013

01-01-2013

Increased Detection of Non-recurrent Inferior Laryngeal Nerve (NRLN) During Thyroid Surgery Using Systematic Intraoperative Neuromonitoring (IONM)

Authors: G. Donatini, B. Carnaille, G. Dionigi

Published in: World Journal of Surgery | Issue 1/2013

Login to get access

Abstract

Background

Non-recurrent inferior laryngeal nerve (NRLN) is a rare anatomical variant with a reported incidence of 0.6–1.3 %. It carries a higher risk of palsy during thyroid surgery. Its detection is mandatory in order to avoid such complication.

Methods

Systematic intraoperative neuromonitoring (IONM) was carried out for 806 consecutive nerve at risk (NAR) patients in two centers (Lille and Varese). In 402 patients surgery to the right side was performed with IONM. The IONM of the inferior laryngeal nerve (ILN) was conducted as recommended by international guidelines (V1/R1/V2/R2).

Results

A NRLN was detected in 11 of 402 NAR (2.7 %). In the first center (Lille) the incidence of NRLN was 6.0 % (7/117). No loss of signal (LOS) was reported in this group of patients. Postoperative laryngoscopy was normal in all patients with NRLN.

Conclusions

The true incidence of NRLN may be higher than expected. Neurophysiology helps the surgeon to better understand the anatomy and function of nervous structures. Intraoperative neuromonitoring is a useful tool that should be systematically implemented in thyroid surgery to better understand the anatomy and physiology of the inferior laryngeal nerve. Its use may allow the surgeon to decrease the incidence of nerve palsy especially in case of NRLN. The IONM adjunct does not add significantly to the costs for thyroid surgery.
Literature
1.
go back to reference Henry JF, Audiffret J, Denizot A et al (1988) The nonrecurrent inferior laryngeal nerve: review of 33 cases including two on the left side. Surgery 104:977–984PubMed Henry JF, Audiffret J, Denizot A et al (1988) The nonrecurrent inferior laryngeal nerve: review of 33 cases including two on the left side. Surgery 104:977–984PubMed
3.
go back to reference Iacobone M, Viel G, Zanella S et al (2008) The usefulness of preoperative ultrasonographic identification of nonrecurrent inferior laryngeal nerve in neck surgery. Langenbecks Arch Surg 393:633–638PubMedCrossRef Iacobone M, Viel G, Zanella S et al (2008) The usefulness of preoperative ultrasonographic identification of nonrecurrent inferior laryngeal nerve in neck surgery. Langenbecks Arch Surg 393:633–638PubMedCrossRef
4.
go back to reference Avisse C, Marcus C, Delattre JF et al (1998) Right nonrecurrent inferior laryngeal nerve and arteria lusoria: the diagnostic and therapeutic implications of an anatomic anomaly. Review of 17 cases. Surg Radiol Anat 20:227–232PubMed Avisse C, Marcus C, Delattre JF et al (1998) Right nonrecurrent inferior laryngeal nerve and arteria lusoria: the diagnostic and therapeutic implications of an anatomic anomaly. Review of 17 cases. Surg Radiol Anat 20:227–232PubMed
5.
go back to reference Brauckhoff M, Gimm O, Thanh PN et al (2002) First experiences in intraoperative neurostimulation of the recurrent laryngeal nerve during thyroid surgery of children and adolescents. J Pediatr Surg 37:1414–1418PubMedCrossRef Brauckhoff M, Gimm O, Thanh PN et al (2002) First experiences in intraoperative neurostimulation of the recurrent laryngeal nerve during thyroid surgery of children and adolescents. J Pediatr Surg 37:1414–1418PubMedCrossRef
6.
go back to reference Brauckhoff M, Walls G, Brauckhoff K et al (2002) Identification of the non-recurrent inferior laryngeal nerve using intraoperative neurostimulation. Langenbecks Arch Surg 386:482–487PubMedCrossRef Brauckhoff M, Walls G, Brauckhoff K et al (2002) Identification of the non-recurrent inferior laryngeal nerve using intraoperative neurostimulation. Langenbecks Arch Surg 386:482–487PubMedCrossRef
7.
go back to reference Raffaelli M, Iacobone M, Henry JF (2000) The “false” nonrecurrent inferior laryngeal nerve. Surgery 128:1082–1087PubMedCrossRef Raffaelli M, Iacobone M, Henry JF (2000) The “false” nonrecurrent inferior laryngeal nerve. Surgery 128:1082–1087PubMedCrossRef
8.
go back to reference Dionigi G, Bacuzzi A, Barczynski M et al (2011) Implementation of systematic neuromonitoring training for thyroid surgery. Updates Surg 63:201–207PubMedCrossRef Dionigi G, Bacuzzi A, Barczynski M et al (2011) Implementation of systematic neuromonitoring training for thyroid surgery. Updates Surg 63:201–207PubMedCrossRef
9.
go back to reference Higgins TS, Gupta R, Ketcham AS et al (2011) Recurrent laryngeal nerve monitoring versus identification alone on post-thyroidectomy true vocal fold palsy: a meta-analysis. Laryngoscope 121:1009–1017 [Review]PubMedCrossRef Higgins TS, Gupta R, Ketcham AS et al (2011) Recurrent laryngeal nerve monitoring versus identification alone on post-thyroidectomy true vocal fold palsy: a meta-analysis. Laryngoscope 121:1009–1017 [Review]PubMedCrossRef
10.
go back to reference Dralle H, Dralle H, the International Intraoperative Monitoring Study Group (2011) Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope 121(Suppl 1):S1–S16 [Review]PubMed Dralle H, Dralle H, the International Intraoperative Monitoring Study Group (2011) Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope 121(Suppl 1):S1–S16 [Review]PubMed
11.
go back to reference Dionigi G, Chiang FY, Rausei S et al (2010) Surgical anatomy and neurophysiology of the vagus nerve (VN) for standardised intraoperative neuromonitoring (IONM) of the inferior laryngeal nerve (ILN) during thyroidectomy. Langenbecks Arch Surg 395:893–899PubMedCrossRef Dionigi G, Chiang FY, Rausei S et al (2010) Surgical anatomy and neurophysiology of the vagus nerve (VN) for standardised intraoperative neuromonitoring (IONM) of the inferior laryngeal nerve (ILN) during thyroidectomy. Langenbecks Arch Surg 395:893–899PubMedCrossRef
12.
go back to reference Barczynski M, Konturek A, Chicon S (2009) Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy. Br J Surg 96:240–246PubMedCrossRef Barczynski M, Konturek A, Chicon S (2009) Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy. Br J Surg 96:240–246PubMedCrossRef
13.
go back to reference Chiang FY, Lu IC, Tsai CJ et al (2012) Detecting and identifying nonrecurrent laryngeal nerve with the application of intraoperative neuromonitoring during thyroid and parathyroid operation. Am J Otolaryngol 33:1–5PubMedCrossRef Chiang FY, Lu IC, Tsai CJ et al (2012) Detecting and identifying nonrecurrent laryngeal nerve with the application of intraoperative neuromonitoring during thyroid and parathyroid operation. Am J Otolaryngol 33:1–5PubMedCrossRef
14.
go back to reference Brauckhoff M, Machens A, Sekulla C et al (2011) Latencies shorter than 3.5 ms after vagus nerve stimulation signify a nonrecurrent inferior laryngeal nerve before dissection. Ann Surg 253:1172–1177PubMedCrossRef Brauckhoff M, Machens A, Sekulla C et al (2011) Latencies shorter than 3.5 ms after vagus nerve stimulation signify a nonrecurrent inferior laryngeal nerve before dissection. Ann Surg 253:1172–1177PubMedCrossRef
Metadata
Title
Increased Detection of Non-recurrent Inferior Laryngeal Nerve (NRLN) During Thyroid Surgery Using Systematic Intraoperative Neuromonitoring (IONM)
Authors
G. Donatini
B. Carnaille
G. Dionigi
Publication date
01-01-2013
Publisher
Springer-Verlag
Published in
World Journal of Surgery / Issue 1/2013
Print ISSN: 0364-2313
Electronic ISSN: 1432-2323
DOI
https://doi.org/10.1007/s00268-012-1782-y

Other articles of this Issue 1/2013

World Journal of Surgery 1/2013 Go to the issue

Acknowledgments

2012 Acknowledgements