Abstract

Background

A small remnant liver volume is an important risk factor for posthepatectomy liver failure. ImageJ and OsiriX® are both free, open-source image processing software packages. The aim of the present study was to compare ImageJ and OsiriX® in performing prospective computed tomography (CT) volumetric analysis of the liver on a personal computer (PC) in patients undergoing major liver resection.

Methods

Patients scheduled for a right hemihepatectomy were eligible for inclusion. Two surgeons and one surgical trainee measured volumes of total liver, tumor, and future resection specimen prospectively with ImageJ and OsiriX®. A radiologist also measured these volumes with CT scanner-linked Aquarius iNtuition® software. Resection volumes were compared with the actual weights of the liver specimens removed during surgery, and differences between the measured liver volumes were analyzed.

Results

A total of 15 patients (8 men, 7 women) with a median age of 63 years (48–79 years) were included. There was a significant correlation between the measured weights of resection specimens and the volumes calculated prospectively with ImageJ and OsiriX® (r = 0.89; r = 0.83, respectively). There was also a significant correlation between the volumes measured with radiological software iNtuition® and the volumes measured with ImageJ and OsiriX® (r = 0.93; r = 0.95, respectively).

Conclusions

There were no major differences in total liver volumes, resection volumes, or tumour volumes for these three software packages. Prospective hepatic CT volumetry with ImageJ or OsiriX® is reliable and can be accurately used on a PC by nonradiologists. ImageJ and OsiriX® yield results comparable to the radiological software iNtuition®.
Literature
1.
go back to reference Shah SA, Haddad R, Al-Sukhni W et al (2006) Surgical resection of hepatic and pulmonary metastases from colorectal carcinoma. J Am Coll Surg 202:468–475CrossRefPubMed Shah SA, Haddad R, Al-Sukhni W et al (2006) Surgical resection of hepatic and pulmonary metastases from colorectal carcinoma. J Am Coll Surg 202:468–475CrossRefPubMed
2.
3.
go back to reference Scheele J, Altendorf-Hofmann A, Grube T et al (2001) Resection of colorectal liver metastases: what prognostic factors determine patient selection? Chirurg 72:547–560CrossRefPubMed Scheele J, Altendorf-Hofmann A, Grube T et al (2001) Resection of colorectal liver metastases: what prognostic factors determine patient selection? Chirurg 72:547–560CrossRefPubMed
4.
go back to reference Schindl MJ, Redhead DN, Fearon KC et al (2005) The value of residual liver volume as a predictor of hepatic dysfunction and infection after major liver resection. Gut 54:289–296CrossRefPubMed Schindl MJ, Redhead DN, Fearon KC et al (2005) The value of residual liver volume as a predictor of hepatic dysfunction and infection after major liver resection. Gut 54:289–296CrossRefPubMed
5.
go back to reference Shoup M, Gonen M, D’Angelica M et al (2003) Volumetric analysis predicts hepatic dysfunction in patients undergoing major liver resection. J Gastrointest Surg 7:325–330CrossRefPubMed Shoup M, Gonen M, D’Angelica M et al (2003) Volumetric analysis predicts hepatic dysfunction in patients undergoing major liver resection. J Gastrointest Surg 7:325–330CrossRefPubMed
6.
go back to reference Jarnagin WR, Gonen M, Fong Y et al (2002) Improvement in perioperative outcome after hepatic resection: analysis of 1,803 consecutive cases over the past decade. Ann Surg 236:397–407CrossRefPubMed Jarnagin WR, Gonen M, Fong Y et al (2002) Improvement in perioperative outcome after hepatic resection: analysis of 1,803 consecutive cases over the past decade. Ann Surg 236:397–407CrossRefPubMed
7.
go back to reference Karlo C, Reiner CS, Stolzmann P et al (2010) CT- and MRI-based volumetry of resected liver specimen: comparison to intraoperative volume and weight measurements and calculation of conversion factors. Eur J Radiol 75:107–111CrossRef Karlo C, Reiner CS, Stolzmann P et al (2010) CT- and MRI-based volumetry of resected liver specimen: comparison to intraoperative volume and weight measurements and calculation of conversion factors. Eur J Radiol 75:107–111CrossRef
8.
go back to reference Rasband W (1997–2005) ImageJ, 1.33 edn. National Institutes of Health, Bethesda Rasband W (1997–2005) ImageJ, 1.33 edn. National Institutes of Health, Bethesda
9.
go back to reference Kishi Y, Abdalla EK, Chun YS et al (2009) Three hundred and one consecutive extended right hepatectomies: evaluation of outcome based on systematic liver volumetry. Ann Surg, Aug 27 [Epub ahead of print] Kishi Y, Abdalla EK, Chun YS et al (2009) Three hundred and one consecutive extended right hepatectomies: evaluation of outcome based on systematic liver volumetry. Ann Surg, Aug 27 [Epub ahead of print]
10.
go back to reference Wigmore SJ, Redhead DN, Yan XJ et al (2001) Virtual hepatic resection using three-dimensional reconstruction of helical computed tomography angioportograms. Ann Surg 233:221–226CrossRefPubMed Wigmore SJ, Redhead DN, Yan XJ et al (2001) Virtual hepatic resection using three-dimensional reconstruction of helical computed tomography angioportograms. Ann Surg 233:221–226CrossRefPubMed
11.
go back to reference Dello SA, van Dam RM, Slangen JJ et al (2007) Liver volumetry plug and play: do it yourself with ImageJ. World J Surg 31:2215–2221CrossRefPubMed Dello SA, van Dam RM, Slangen JJ et al (2007) Liver volumetry plug and play: do it yourself with ImageJ. World J Surg 31:2215–2221CrossRefPubMed
12.
go back to reference Van der Vorst JR, van Dam RM, van Stiphout RS et al (2010) Virtual liver resection and volumetric analysis of the future liver remnant using open source image processing software. World J Surg 34:2426–2433CrossRefPubMed Van der Vorst JR, van Dam RM, van Stiphout RS et al (2010) Virtual liver resection and volumetric analysis of the future liver remnant using open source image processing software. World J Surg 34:2426–2433CrossRefPubMed
13.
go back to reference Lu Y, Wu Z, Liu C, Wang HH (2004) Hepatic volumetry with PhotoShop in personal computer. Hepatobiliary Pancreat Dis Int 3:82–85PubMed Lu Y, Wu Z, Liu C, Wang HH (2004) Hepatic volumetry with PhotoShop in personal computer. Hepatobiliary Pancreat Dis Int 3:82–85PubMed
14.
go back to reference Tu R, Xia LP, Yu AL et al (2007) Assessment of hepatic functional reserve by cirrhosis grading and liver volume measurement using CT. World J Gastroenterol 13:3956–3961PubMed Tu R, Xia LP, Yu AL et al (2007) Assessment of hepatic functional reserve by cirrhosis grading and liver volume measurement using CT. World J Gastroenterol 13:3956–3961PubMed
15.
go back to reference Dejong CHC, Garden OJ (2003) Neoplasms of the liver. In: Majid AA, Kingsnorth A (eds) Advanced surgical practice. Greenwich Medical Media, London, pp 146–156 Dejong CHC, Garden OJ (2003) Neoplasms of the liver. In: Majid AA, Kingsnorth A (eds) Advanced surgical practice. Greenwich Medical Media, London, pp 146–156
16.
go back to reference Bland JM, Altman DG (1995) Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 346:1085–1087CrossRefPubMed Bland JM, Altman DG (1995) Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 346:1085–1087CrossRefPubMed
17.
go back to reference Reiner CS, Karlo C, Petrowsky H et al (2009) Preoperative liver volumetry: how does the slice thickness influence the multidetector computed tomography- and magnetic resonance-liver volume measurements? J Comput Assist Tomogr 33:390–397CrossRefPubMed Reiner CS, Karlo C, Petrowsky H et al (2009) Preoperative liver volumetry: how does the slice thickness influence the multidetector computed tomography- and magnetic resonance-liver volume measurements? J Comput Assist Tomogr 33:390–397CrossRefPubMed
18.
go back to reference Lemke AJ, Brinkmann MJ, Schott T et al (2006) Living donor right liver lobes: preoperative CT volumetric measurement for calculation of intraoperative weight and volume. Radiology 240:736–742CrossRefPubMed Lemke AJ, Brinkmann MJ, Schott T et al (2006) Living donor right liver lobes: preoperative CT volumetric measurement for calculation of intraoperative weight and volume. Radiology 240:736–742CrossRefPubMed
19.
go back to reference Hwang S, Lee SG, Kim KH et al (2002) Correlation of blood-free graft weight and volumetric graft volume by an analysis of blood content in living donor liver grafts. Transplant Proc 34:3293–3294CrossRefPubMed Hwang S, Lee SG, Kim KH et al (2002) Correlation of blood-free graft weight and volumetric graft volume by an analysis of blood content in living donor liver grafts. Transplant Proc 34:3293–3294CrossRefPubMed
Metadata
Title
Prospective Volumetric Assessment of the Liver on a Personal Computer by Nonradiologists Prior to Partial Hepatectomy
Authors
Simon A. W. G. Dello
Jan H. M. B. Stoot
Rogier S. A. van Stiphout
Johanne G. Bloemen
Stephen J. Wigmore
Cornelis H. C. Dejong
Ronald M. van Dam
Publication date
01-02-2011
Publisher
Springer-Verlag
Published in
World Journal of Surgery / Issue 2/2011
Print ISSN: 0364-2313
Electronic ISSN: 1432-2323
DOI
https://doi.org/10.1007/s00268-010-0877-6

Other articles of this Issue 2/2011

World Journal of Surgery 2/2011 Go to the issue