Excerpt

I read with interest an article recently published in World Journal of Surgery in which Genta et al. reported the use of ultrasound-guided fine-needle aspiration cytology(US-FNAC), sentinel node biopsy(SNB), and frozen section of a node in breast cancer [1], and I wish make a suggestion that might further refine axillary management in breast cancer. …
Literature
1.
go back to reference Genta F, Zanon E, Camanni M, et al. (2007) Cost/accuracy ratio analysis in breast cancer patients undergoing ultrasound-guided fine-needle aspiration cytology, sentinel node biopsy, and frozen section of node. World J Surg 31:1157–1165CrossRef Genta F, Zanon E, Camanni M, et al. (2007) Cost/accuracy ratio analysis in breast cancer patients undergoing ultrasound-guided fine-needle aspiration cytology, sentinel node biopsy, and frozen section of node. World J Surg 31:1157–1165CrossRef
2.
go back to reference Tan M (2006) Surmounting the challenges of sentinel lymph node biopsy for breast cancer in non-tertiary centres and community-based practices. Aust N Z J Surg 76:306–309CrossRef Tan M (2006) Surmounting the challenges of sentinel lymph node biopsy for breast cancer in non-tertiary centres and community-based practices. Aust N Z J Surg 76:306–309CrossRef
3.
go back to reference Sener SF, Winchester DJ, Brinkmann E, et al. (2004) Failure of sentinel lymph node mapping in patients with breast cancer. J Am Coll Surg 198:732–736PubMedCrossRef Sener SF, Winchester DJ, Brinkmann E, et al. (2004) Failure of sentinel lymph node mapping in patients with breast cancer. J Am Coll Surg 198:732–736PubMedCrossRef
4.
go back to reference Brancato B, Zappa M, Bricolo D, et al. (2004) Role of ultrasound-guided fine needle cytology of axillary lymph nodes in breast carcinoma staging. Radiol Med (Torino) 108:345–355 Brancato B, Zappa M, Bricolo D, et al. (2004) Role of ultrasound-guided fine needle cytology of axillary lymph nodes in breast carcinoma staging. Radiol Med (Torino) 108:345–355
5.
go back to reference Paajanen H, Kilponen VM, Heikkinen J, et al. (2006) Feasibility of axillary ultrasound in the quality assessment of sentinel node biopsy in breast cancer surgery. Scand J Surg 95:195–198PubMed Paajanen H, Kilponen VM, Heikkinen J, et al. (2006) Feasibility of axillary ultrasound in the quality assessment of sentinel node biopsy in breast cancer surgery. Scand J Surg 95:195–198PubMed
6.
go back to reference Ciatto S, Brancato B, Risso G, et al. (2007) Accuracy of fine needle aspiration cytology (FNAC) of axillary lymph nodes as a triage test in breast cancer staging. Br Cancer Res Treat 103:85–91CrossRef Ciatto S, Brancato B, Risso G, et al. (2007) Accuracy of fine needle aspiration cytology (FNAC) of axillary lymph nodes as a triage test in breast cancer staging. Br Cancer Res Treat 103:85–91CrossRef
Metadata
Title
Cost/Accuracy Ratio Analysis in Breast Cancer Patients Undergoing Ultrasound-Guided Fine-Needle Aspiration Cytology, Sentinel Node Biopsy, and Frozen Section of Node
Author
Mona P. Tan
Publication date
01-01-2008
Publisher
Springer-Verlag
Published in
World Journal of Surgery / Issue 1/2008
Print ISSN: 0364-2313
Electronic ISSN: 1432-2323
DOI
https://doi.org/10.1007/s00268-007-9254-5

Other articles of this Issue 1/2008

World Journal of Surgery 1/2008 Go to the issue

Letter

Reply