Authors: Martin Gotthardt, M.D., Bodo Lohmann, M.D., Thomas M. Behr, M.D., Artur Bauhofer, Ph.D., Christiane Franzius, M.D., Meike L. Schipper, M.D., Maria Wagner, M.D., Helmut Höffken, M.D., Helmut Sitter, Ph.D., Matthias Rothmund, M.D., Klaus Joseph, M.D., Christoph Nies, M.D.

Published in: World Journal of Surgery | Issue 1/2004

Login to get access

Abstract

There is a considerable discrepancy in the literature concerning the sensitivity of parathyroid scintigraphy (PS) with 99mTc-MIBI. We therefore analyzed our own data and compared them to the literature in a metaanalysis. All patients who received 99mTc -MIBI scintigraphy and subsequent surgery in our department for the detection of enlarged parathyroid glands in primary (pHPT) or secondary (sHPT) hyperparathyroidism between 1991 and 1999 were included in our retrospective analysis. The results of surgery served as the gold standard. For a true positive result, the scintigraphy had to predict the exact location of parathyroid adenoma (PA) or parathyroid hyperplasia (PH). We then compared these data to the results of a nonstatistical systematic metaanalysis of the literature. Patients (178) underwent PS between 1991 and 1999; 139 were operated on and included in this study. Of these, 109 had pHPT and 30 had sHPT. The sensitivity and specificity of the PS were found to be 45% / 94% for pHPT and 39% / 40% for sHPT. Fifty-two studies concerning PS were included in the metaanalysis. Sensitivities reported varied from 39% to > 90%. Consideration of the different possible techniques used for PS could not explain these discrepancies. Our data show that the sensitivity of PS in clinical routine may be lower than expected from the literature. Our data are consistent with other studies and with partially unpublished clinical observations from other university hospitals. We believe that a well-designed and properly conducted prospective study is necessary to evaluate the reasons for the differences observed.
Literature
1.
go back to reference Taillifer, R, Boucher, Y, Potvin, C, et al. 1992Detection and localization of parathyroid adenomas in patients with hyperparathyroidism using a single radionuclide imaging procedure with technetium-99m-sestamibi (double phase study)J. Nucl. Med.3318011807PubMed Taillifer, R, Boucher, Y, Potvin, C,  et al. 1992Detection and localization of parathyroid adenomas in patients with hyperparathyroidism using a single radionuclide imaging procedure with technetium-99m-sestamibi (double phase study)J. Nucl. Med.3318011807PubMed
2.
go back to reference Giordano, A, Rubello, D, Casara, D 2001New trends in parathyroid scintigraphyEur. J. Nucl. Med.2814091420CrossRefPubMed Giordano, A, Rubello, D, Casara, D 2001New trends in parathyroid scintigraphyEur. J. Nucl. Med.2814091420CrossRefPubMed
3.
go back to reference Norman, JG, Chheda, H 1997Minimally invasive parathyroidectomy facilitated by intraoperative nuclear mappingSurgery1229981003PubMed Norman, JG, Chheda, H 1997Minimally invasive parathyroidectomy facilitated by intraoperative nuclear mappingSurgery1229981003PubMed
4.
go back to reference Norman, JG 1998Minimally invasive radioguided parathyroidectomy: an endocrine surgeon’s perspectiveJ. Nucl. Med.3915N24N Norman, JG 1998Minimally invasive radioguided parathyroidectomy: an endocrine surgeon’s perspectiveJ. Nucl. Med.3915N24N
5.
go back to reference Moka, D, Voth, E, Dietlein, M, et al. 2000Technetium 99m-MIBI SPECT: a highly sensitive diagnostic tool for localization of parathyroid adenomasSurgery1282935CrossRefPubMed Moka, D, Voth, E, Dietlein, M,  et al. 2000Technetium 99m-MIBI SPECT: a highly sensitive diagnostic tool for localization of parathyroid adenomasSurgery1282935CrossRefPubMed
6.
go back to reference Moka, D, Eschner, W, Voth, E, et al. 2000Iterative reconstruction: an improvement of technetium 99m-MIBI SPECT for the detection of parathyroid adenomas?Eur. J. Nucl. Med.27485489CrossRefPubMed Moka, D, Eschner, W, Voth, E,  et al. 2000Iterative reconstruction: an improvement of technetium 99m-MIBI SPECT for the detection of parathyroid adenomas?Eur. J. Nucl. Med.27485489CrossRefPubMed
7.
go back to reference Walgenbach, S, Dutkowski, P, Andreas, J, et al. 199999mTc-MIBI Szintigraphie vor Eingriffen wegen Hyperparathyreoidismus? (99mTc-MIBI scintigraphy before parathyroid surgery?)Zentralblatt f. Chirurgie124214219 Walgenbach, S, Dutkowski, P, Andreas, J,  et al. 199999mTc-MIBI Szintigraphie vor Eingriffen wegen Hyperparathyreoidismus? (99mTc-MIBI scintigraphy before parathyroid surgery?)Zentralblatt f. Chirurgie124214219
8.
go back to reference Moka, D, Voth, E, Larena-Avellaneda, A, et al. 199799mTc-MIBI-SPECT zur prôoperativen Lokalisationsdiagnostik kleiner Nebenschilddrüsenadenome (99mTc-MIBI SPECT for preoperative localization of small parathyroid adenomas)Nuklearmedizin36240244PubMed Moka, D, Voth, E, Larena-Avellaneda, A,  et al. 199799mTc-MIBI-SPECT zur prôoperativen Lokalisationsdiagnostik kleiner Nebenschilddrüsenadenome (99mTc-MIBI SPECT for preoperative localization of small parathyroid adenomas)Nuklearmedizin36240244PubMed
9.
go back to reference Grünwald, F, Spôth, G, Menzel, C, et al. 1995Nebenschilddrüsenszintigrpahie mit 99mTc-MIBI (Parathyroid scintigraphy with 99mTc-MIBI)Med. Klin.90450455PubMed Grünwald, F, Spôth, G, Menzel, C,  et al. 1995Nebenschilddrüsenszintigrpahie mit 99mTc-MIBI (Parathyroid scintigraphy with 99mTc-MIBI)Med. Klin.90450455PubMed
10.
go back to reference Schönemann, B, Wurm, K, Bihl, H, et al. 1996Zum Stellenwert der 99mTc-MIBI-Szintigraphie bei der Lokalisationsdiagnostik des Hyperparathyreoidismus. Eine prospektive Studie. (The value of 99mTc-MIBI scintigraphy in diagnostic localization of hyperparathyroidism. A prospective study)Chirurg673236PubMed Schönemann, B, Wurm, K, Bihl, H,  et al. 1996Zum Stellenwert der 99mTc-MIBI-Szintigraphie bei der Lokalisationsdiagnostik des Hyperparathyreoidismus. Eine prospektive Studie. (The value of 99mTc-MIBI scintigraphy in diagnostic localization of hyperparathyroidism. A prospective study)Chirurg673236PubMed
11.
go back to reference Joseph, K, Welcke, U, Höffken, H, et al. 1994Szintigraphische Darstellung von Adenomen der Nebenschilddrüse mit 99mTc-Sestamibi in einem Strumaendemiegebiet (scintigraphic detection of parathyroid adenomas with 99mTc-Sestamibi in an endemic goiter area)Nuklearmedizin339398PubMed Joseph, K, Welcke, U, Höffken, H,  et al. 1994Szintigraphische Darstellung von Adenomen der Nebenschilddrüse mit 99mTc-Sestamibi in einem Strumaendemiegebiet (scintigraphic detection of parathyroid adenomas with 99mTc-Sestamibi in an endemic goiter area)Nuklearmedizin339398PubMed
12.
go back to reference Evans, M, Pollock, VA 1985A score system for evaluating random control clinical trials of prophylaxis of abdominal surgical wound infectionBr. J. Surg.72256260PubMed Evans, M, Pollock, VA 1985A score system for evaluating random control clinical trials of prophylaxis of abdominal surgical wound infectionBr. J. Surg.72256260PubMed
13.
go back to reference Bland, CJ, Meurer, LN, Maldonado, G 1995A systemic approach to conducting a non-statistical meta-analysis of research literatureAcad. Med.70642653PubMed Bland, CJ, Meurer, LN, Maldonado, G 1995A systemic approach to conducting a non-statistical meta-analysis of research literatureAcad. Med.70642653PubMed
14.
go back to reference McHenry, CR, Lee, K, Saadey, J, et al. 1996Parathyroid localization with technetium-99m-sestamibi: a prospective evaluationJ. Am. Coll. Surg.1832530PubMed McHenry, CR, Lee, K, Saadey, J,  et al. 1996Parathyroid localization with technetium-99m-sestamibi: a prospective evaluationJ. Am. Coll. Surg.1832530PubMed
15.
go back to reference Ishibashi, M, Nishida, H, Hiromatsu, Y, et al. 1998Comparison of technetium-99m-MIBI, technetium-99m-terofosmin, ultrasound and MRI for localization of abnormal parathyroid glandsJ. Nucl. Med.39320324PubMed Ishibashi, M, Nishida, H, Hiromatsu, Y,  et al. 1998Comparison of technetium-99m-MIBI, technetium-99m-terofosmin, ultrasound and MRI for localization of abnormal parathyroid glandsJ. Nucl. Med.39320324PubMed
16.
go back to reference Feo, ML, Colagrande, S, Biagini, C, et al. 2000Parathyroid glands: combination of 99mTc MIBI scintigraphy and US for demonstration of parathyroid glands and nodulesRadiology214393402PubMed Feo, ML, Colagrande, S, Biagini, C,  et al. 2000Parathyroid glands: combination of 99mTc MIBI scintigraphy and US for demonstration of parathyroid glands and nodulesRadiology214393402PubMed
17.
go back to reference Torregrosa, JV, Fernandez-Cruz, L, Canalejo, A, et al. 200099mTc-sestamibi scintigraphy and cell cycle in parathyroid glands of secondary hyperparathyroidismWorld J. Surg.2413861390CrossRefPubMed Torregrosa, JV, Fernandez-Cruz, L, Canalejo, A,  et al. 200099mTc-sestamibi scintigraphy and cell cycle in parathyroid glands of secondary hyperparathyroidismWorld J. Surg.2413861390CrossRefPubMed
18.
go back to reference Takebayashi, S, Hidai, H, Chiba, T, et al. 1999Hyperfunctional parathyroid glands with 99mTc-MIBI scan: semiquantitative analysis correlated with histologic findingsJ. Nucl. Med.4017921797PubMed Takebayashi, S, Hidai, H, Chiba, T,  et al. 1999Hyperfunctional parathyroid glands with 99mTc-MIBI scan: semiquantitative analysis correlated with histologic findingsJ. Nucl. Med.4017921797PubMed
19.
go back to reference Bugis, SP, Berno, E, Rusnak, CH, et al. 1995Technetium99m-sestamibi scanning before initial neck exploration in patients with primary hyperparathyroidismEur. Arch. Oto-Rhino-Laryngol.252149152 Bugis, SP, Berno, E, Rusnak, CH,  et al. 1995Technetium99m-sestamibi scanning before initial neck exploration in patients with primary hyperparathyroidismEur. Arch. Oto-Rhino-Laryngol.252149152
20.
go back to reference Rauth, JD, Sessions, RB, Shupe, SC, et al. 1996Comparison of Tc-99m MIBI and TI-201/Tc-99m pertechnetate for diagnosis of primary hyperparathyroidismClin. Nucl. Med.21602608CrossRefPubMed Rauth, JD, Sessions, RB, Shupe, SC,  et al. 1996Comparison of Tc-99m MIBI and TI-201/Tc-99m pertechnetate for diagnosis of primary hyperparathyroidismClin. Nucl. Med.21602608CrossRefPubMed
21.
go back to reference Ishibashi, M, Nishida, H, Hiromatsu, Y, et al. 1997Localization of ectopic parathyroid glands using technetium-99m sestamibi imaging: comparison with magnetic resonance and computed tomographic imagingEur. J. Nucl. Med.24197201PubMed Ishibashi, M, Nishida, H, Hiromatsu, Y,  et al. 1997Localization of ectopic parathyroid glands using technetium-99m sestamibi imaging: comparison with magnetic resonance and computed tomographic imagingEur. J. Nucl. Med.24197201PubMed
22.
go back to reference Carter, WB, Sarfati, MR, Fox, KA, et al. 1997Preoperative detection of sporadic parathyroid adenomas using technetium-99m-sestamibi: what role in clinical practice?Am. Surg.63317321PubMed Carter, WB, Sarfati, MR, Fox, KA,  et al. 1997Preoperative detection of sporadic parathyroid adenomas using technetium-99m-sestamibi: what role in clinical practice?Am. Surg.63317321PubMed
23.
go back to reference Hindié, E, Melliere, D, Jeanguillaume, C, et al. 1998Parathyroid imaging using simultaneous double-window recording of 99mTc-sestamibi and 123IJ. Nucl. Med.3911001105PubMed Hindié, E, Melliere, D, Jeanguillaume, C,  et al. 1998Parathyroid imaging using simultaneous double-window recording of 99mTc-sestamibi and 123IJ. Nucl. Med.3911001105PubMed
24.
go back to reference Pinero, A, Rodriguez, JM, Ortiz, S, et al. 2000Relation of biochemical, cytologic, and morpholigic parameters to the result of gammagraphy with technetium 99m sestamibi in primary hyperparathyroidismOtolaryngol. Head Neck Surg.122851855PubMed Pinero, A, Rodriguez, JM, Ortiz, S,  et al. 2000Relation of biochemical, cytologic, and morpholigic parameters to the result of gammagraphy with technetium 99m sestamibi in primary hyperparathyroidismOtolaryngol. Head Neck Surg.122851855PubMed
25.
go back to reference Torregrosa, JV, Palomar, MR, Pons, F, et al. 1998Has double-phase MIBI scintigraphy usefulness in the diagnosis of hyperparathyroidism?Nephrol. Dial. Transplant.133740CrossRef Torregrosa, JV, Palomar, MR, Pons, F,  et al. 1998Has double-phase MIBI scintigraphy usefulness in the diagnosis of hyperparathyroidism?Nephrol. Dial. Transplant.133740CrossRef
26.
go back to reference Ishibashi, M, Nishida, H, Okuda, S, et al. 1998Localization of parathyroid glands in hemodialysis patients using Tc- 99m sestamibi imagingNephron784853PubMed Ishibashi, M, Nishida, H, Okuda, S,  et al. 1998Localization of parathyroid glands in hemodialysis patients using Tc- 99m sestamibi imagingNephron784853PubMed
27.
go back to reference Takami, H, Oshima, M, Sugawara, I, et al. 1999Pre-operative localization and tissue uptake study in parathyroid imaging with technetium-99m-sestamibiAust. N. Z. J. Surg.69629631CrossRefPubMed Takami, H, Oshima, M, Sugawara, I,  et al. 1999Pre-operative localization and tissue uptake study in parathyroid imaging with technetium-99m-sestamibiAust. N. Z. J. Surg.69629631CrossRefPubMed
28.
go back to reference Billy, HT, Rimkus, DR, Hartzmann, S, et al. 1995Technetium-99m-sestamibi single agent localization versus high resolution ultrasonography for the preoperative localization of parathyroid glands in patients with primary hyperparathyroidismAm. Surg.61882888PubMed Billy, HT, Rimkus, DR, Hartzmann, S,  et al. 1995Technetium-99m-sestamibi single agent localization versus high resolution ultrasonography for the preoperative localization of parathyroid glands in patients with primary hyperparathyroidismAm. Surg.61882888PubMed
29.
go back to reference Hindié, E, Urena, P, Jeanguillaume, C, et al. 1999Preoperative imaging of parathyroid glands with 99mTc-labelled sestamibi and 123I subtraction scanning in secondary hyperparathyroidismLancet35322002204CrossRefPubMed Hindié, E, Urena, P, Jeanguillaume, C,  et al. 1999Preoperative imaging of parathyroid glands with 99mTc-labelled sestamibi and 123I subtraction scanning in secondary hyperparathyroidismLancet35322002204CrossRefPubMed
30.
go back to reference Klieger, P, O’Mara, R 1998The diagnostic utility of dual phase 99mTc-sestamibi parathyroid imagingClin. Nucl. Med.23208211CrossRefPubMed Klieger, P, O’Mara, R 1998The diagnostic utility of dual phase 99mTc-sestamibi parathyroid imagingClin. Nucl. Med.23208211CrossRefPubMed
31.
go back to reference Mazzeo, S, Caramella, D, Lencioni, R, et al. 1996Comparison among sonography, double-tracer substraction scintigraphy and double-phase scintigraphy in the detection of parathyroid lesionsAm. J. Roentgenol.16614651470 Mazzeo, S, Caramella, D, Lencioni, R,  et al. 1996Comparison among sonography, double-tracer substraction scintigraphy and double-phase scintigraphy in the detection of parathyroid lesionsAm. J. Roentgenol.16614651470
32.
go back to reference Neumann, DR, Esselstyn, CB,Jr, Go, RT, et al. 1997Comparison of double-phase 99mTc-sestamibi with 123I-99mTc-sestamibi subtraction SPECT in hyperparathyroidismAm. J. Roentgenol.16916711674 Neumann, DR, Esselstyn, CB,Jr, Go, RT,  et al. 1997Comparison of double-phase 99mTc-sestamibi with 123I-99mTc-sestamibi subtraction SPECT in hyperparathyroidismAm. J. Roentgenol.16916711674
33.
go back to reference Berna, L, Piera, J, Rodrigues-Espinosa, J, et al. 1999Isotopic study with double phase 99mTc-sestamibi in the localization of parathyroid gland lesionsMed. Clin. (Barc).112201205 Berna, L, Piera, J, Rodrigues-Espinosa, J,  et al. 1999Isotopic study with double phase 99mTc-sestamibi in the localization of parathyroid gland lesionsMed. Clin. (Barc).112201205
34.
go back to reference Chen, CC, Holder, LE, Scovill, E, et al. 1997Comparison of parathyroid imaging with 99mTc-pertechnetate / sestamibi subtraction double-phase 99mTc-sestamibi, and 99mTc-sestamibi SPECTJ. Nucl. Med.38834839PubMed Chen, CC, Holder, LE, Scovill, E,  et al. 1997Comparison of parathyroid imaging with 99mTc-pertechnetate / sestamibi subtraction double-phase 99mTc-sestamibi, and 99mTc-sestamibi SPECTJ. Nucl. Med.38834839PubMed
35.
go back to reference Kusakabe, K, Oshima, M, Takami, H, et al. 1998Evaluation of clinical utility of 99m-Tc-MIBI scintigraphy in the localization of hyperfunctioning parathyroid lesions in patients with hyperparathyroidism—a report of multicentre phase III clinical trialsKaku Igaku35887899 Kusakabe, K, Oshima, M, Takami, H,  et al. 1998Evaluation of clinical utility of 99m-Tc-MIBI scintigraphy in the localization of hyperfunctioning parathyroid lesions in patients with hyperparathyroidism—a report of multicentre phase III clinical trialsKaku Igaku35887899
36.
go back to reference Blocklet, D, Martin, P, Schoutens, A, et al. 1997Presurgical localization of abnormal parathyroid glands using a single injection of technetium-99m methoxyisobutylisonitrile: comparison of different techniques including factor analysis of dynamic structuresEur. J. Nucl. Med.244651PubMed Blocklet, D, Martin, P, Schoutens, A,  et al. 1997Presurgical localization of abnormal parathyroid glands using a single injection of technetium-99m methoxyisobutylisonitrile: comparison of different techniques including factor analysis of dynamic structuresEur. J. Nucl. Med.244651PubMed
37.
go back to reference Light, VL, McHenry, CR, Jarjoura, D, et al. 1996Prospective comparison of dual-phase technetium-99m-sestamibi scintigraphy and high resolution ultrasonography in the evaluation of abnormal parathyroid glandsAm. Surg.62562567PubMed Light, VL, McHenry, CR, Jarjoura, D,  et al. 1996Prospective comparison of dual-phase technetium-99m-sestamibi scintigraphy and high resolution ultrasonography in the evaluation of abnormal parathyroid glandsAm. Surg.62562567PubMed
38.
go back to reference Caixas, A, Berna, L, Hernandez, A, et al. 1997Efficacy of preoperative diagnostic imaging localization of technetium 99m-sestamibi scintigraphy in hyperparathyroidismSurgery121535541PubMed Caixas, A, Berna, L, Hernandez, A,  et al. 1997Efficacy of preoperative diagnostic imaging localization of technetium 99m-sestamibi scintigraphy in hyperparathyroidismSurgery121535541PubMed
39.
go back to reference Fayet, P, Hoeffel, C, Fulla, Y, et al. 199799mTc-sestamibi scintigraphy, magnetic resonance imaging, and venous blood sampling in persistent and recurrent hyperparathyroidismBr. J. Radiol.70459464PubMed Fayet, P, Hoeffel, C, Fulla, Y,  et al. 199799mTc-sestamibi scintigraphy, magnetic resonance imaging, and venous blood sampling in persistent and recurrent hyperparathyroidismBr. J. Radiol.70459464PubMed
40.
go back to reference Neumann, DR, Esselstyn, CB,Jr, Kim, EY, et al. 1997Preliminary experience with double-phase SPECT using 99mTc-sestamibi in patients with hyperparathyroidismClin. Nucl. Med.22217221CrossRefPubMed Neumann, DR, Esselstyn, CB,Jr, Kim, EY,  et al. 1997Preliminary experience with double-phase SPECT using 99mTc-sestamibi in patients with hyperparathyroidismClin. Nucl. Med.22217221CrossRefPubMed
41.
go back to reference Pons, F, Torregrosa, JV, Vidal-Sicart, S, et al. 1997Preoperative parathyroid gland localization with technetium-99m sestamibi in secondary hyperparathyroidismEur. J. Nucl. Med.2414941498CrossRefPubMed Pons, F, Torregrosa, JV, Vidal-Sicart, S,  et al. 1997Preoperative parathyroid gland localization with technetium-99m sestamibi in secondary hyperparathyroidismEur. J. Nucl. Med.2414941498CrossRefPubMed
42.
go back to reference Castellani, M, Reschini, E, Longari, V, et al. 2001Role of Tc-99m sestamibi scintigraphy in the diagnosis and surgical decision-making process in primary hyperparathyroid diseaseClin. Nucl. Med.26139144CrossRefPubMed Castellani, M, Reschini, E, Longari, V,  et al. 2001Role of Tc-99m sestamibi scintigraphy in the diagnosis and surgical decision-making process in primary hyperparathyroid diseaseClin. Nucl. Med.26139144CrossRefPubMed
43.
go back to reference Cheung, AH, Wheeler, MS, Madanay, LD, et al. 1997Multi-center sestamibi parathyroid imaging study in HawaiiHawaii Med. J.56114117PubMed Cheung, AH, Wheeler, MS, Madanay, LD,  et al. 1997Multi-center sestamibi parathyroid imaging study in HawaiiHawaii Med. J.56114117PubMed
44.
go back to reference Sinha, CK, Hamaker, R, Hamaker, RC, et al. 1997Utility of preoperative radionuclide scanning for primary hyperparathyroidismLaryngoscope107753758CrossRefPubMed Sinha, CK, Hamaker, R, Hamaker, RC,  et al. 1997Utility of preoperative radionuclide scanning for primary hyperparathyroidismLaryngoscope107753758CrossRefPubMed
45.
go back to reference Caixas, A, Berna, L, Piera, J, et al. 1995Utility of 99mTc-sestamibi scintigraphy as a first-line imaging procedure in the preoperative evaluation of hyperparathyroidismClin. Endocrinol.43525530 Caixas, A, Berna, L, Piera, J,  et al. 1995Utility of 99mTc-sestamibi scintigraphy as a first-line imaging procedure in the preoperative evaluation of hyperparathyroidismClin. Endocrinol.43525530
46.
go back to reference Purcell, GP, Dirbas, FM, Jeffrey, RB, et al. 1999Parathyroid localization with high-resolution ultrasound and 99mTc-sestamibiArch. Surg.134824828CrossRefPubMed Purcell, GP, Dirbas, FM, Jeffrey, RB,  et al. 1999Parathyroid localization with high-resolution ultrasound and 99mTc-sestamibiArch. Surg.134824828CrossRefPubMed
47.
go back to reference Piga, M, Bolasco, P, Satta, L, et al. 1996Double phase parathyroid technetium-99m-MIBI scintigraphy to identify functional autonomy in secondary hyperparathyroidismJ. Nucl. Med.37565569PubMed Piga, M, Bolasco, P, Satta, L,  et al. 1996Double phase parathyroid technetium-99m-MIBI scintigraphy to identify functional autonomy in secondary hyperparathyroidismJ. Nucl. Med.37565569PubMed
48.
go back to reference Takei, H, Iino, Y, Endo, K, et al. 1999The efficacy of 99mTc-MIBI scan and intraoperative methylene blue staining for the localization of abnormal parathyroid glandsSurg. Today29307312CrossRefPubMed Takei, H, Iino, Y, Endo, K,  et al. 1999The efficacy of 99mTc-MIBI scan and intraoperative methylene blue staining for the localization of abnormal parathyroid glandsSurg. Today29307312CrossRefPubMed
49.
go back to reference Olaizola, I, Zingraff, J, Heuguerot, C, et al. 200099mTc-sestamibi parathyroid scintigraphy in chronic hemodialysis patients: static and dynamic explorationsNephrol. Dial. Transplant.1512011206CrossRefPubMed Olaizola, I, Zingraff, J, Heuguerot, C,  et al. 200099mTc-sestamibi parathyroid scintigraphy in chronic hemodialysis patients: static and dynamic explorationsNephrol. Dial. Transplant.1512011206CrossRefPubMed
50.
go back to reference Martin, D, Rosen, IB, Ichise, M 1996Evaluation of single isotope technetium 99m-sestamibi in localization efficiency for hyperparathyroidismAm. J. Surg.172633636CrossRefPubMed Martin, D, Rosen, IB, Ichise, M 1996Evaluation of single isotope technetium 99m-sestamibi in localization efficiency for hyperparathyroidismAm. J. Surg.172633636CrossRefPubMed
51.
go back to reference Thompson, GB, Grant, CS, Perrier, ND, et al. 1999Reoperative parathyroid surgery in the era of sestamibi scanning and intraoperative parathyroid hormone monitoringArch. Surg.134699704CrossRefPubMed Thompson, GB, Grant, CS, Perrier, ND,  et al. 1999Reoperative parathyroid surgery in the era of sestamibi scanning and intraoperative parathyroid hormone monitoringArch. Surg.134699704CrossRefPubMed
52.
go back to reference Blanco, I, Carril, JM, Banzo, I, et al. 1998Double-phase Tc-99m sestamibi scintigraphy in the preoperative location of lesions causing hyperparathyroidismClin. Nucl. Med.23291297CrossRefPubMed Blanco, I, Carril, JM, Banzo, I,  et al. 1998Double-phase Tc-99m sestamibi scintigraphy in the preoperative location of lesions causing hyperparathyroidismClin. Nucl. Med.23291297CrossRefPubMed
53.
go back to reference Song, AU, Phillips, TE, Edmond, CV, et al. 1999Success of preoperative imaging and unilateral neck exploration for primary hyperparathyroidismOtorlaryngol. Head Neck Surg.121393397 Song, AU, Phillips, TE, Edmond, CV,  et al. 1999Success of preoperative imaging and unilateral neck exploration for primary hyperparathyroidismOtorlaryngol. Head Neck Surg.121393397
54.
go back to reference Peeler, BB, Martin, WH, Sandler, MP, et al. 1997Sestamibi parathyroid scanning and preoperative localization studies for patients with recurrent/persistent hyperparathyroidism or significant comorbid conditions: development of an optimal localization strategyAm. Surg.633746PubMed Peeler, BB, Martin, WH, Sandler, MP,  et al. 1997Sestamibi parathyroid scanning and preoperative localization studies for patients with recurrent/persistent hyperparathyroidism or significant comorbid conditions: development of an optimal localization strategyAm. Surg.633746PubMed
55.
go back to reference Martin, RCG, Greenwell, D, Flynn, MB 2000Initial neck exploration for untreated hyperparathyroidismAm. Surg.66269372PubMed Martin, RCG, Greenwell, D, Flynn, MB 2000Initial neck exploration for untreated hyperparathyroidismAm. Surg.66269372PubMed
56.
go back to reference Soffermann, RA, Nathan, MH, Fairbank, JT, et al. 1996Preoperative technetium Tc 99m sestamibi imaging. Paving the way to minimal-access parathyroid surgeryArch. Otolaryngol. Head Neck Surg.122369374PubMed Soffermann, RA, Nathan, MH, Fairbank, JT,  et al. 1996Preoperative technetium Tc 99m sestamibi imaging. Paving the way to minimal-access parathyroid surgeryArch. Otolaryngol. Head Neck Surg.122369374PubMed
57.
go back to reference Pattou, F, Oudar, C, Huglo, D, et al. 1998Localization of abnormal parathyroid glands with jugular sampling for parathyroid hormone, and subtraction scanning with sestamibi or tetrofosminAust. N. Z. J. Surg.68108111PubMed Pattou, F, Oudar, C, Huglo, D,  et al. 1998Localization of abnormal parathyroid glands with jugular sampling for parathyroid hormone, and subtraction scanning with sestamibi or tetrofosminAust. N. Z. J. Surg.68108111PubMed
58.
go back to reference Ruf, J, Lopez-Hônninen, E, Ulrich, F, et al. 2001Diagnostic imaging of adenomas of the parathyroid gland: use of MRI, scintigraphy and image fusion in the pre-operative phaseEur. J. Nucl. Med.281055 Ruf, J, Lopez-Hônninen, E, Ulrich, F,  et al. 2001Diagnostic imaging of adenomas of the parathyroid gland: use of MRI, scintigraphy and image fusion in the pre-operative phaseEur. J. Nucl. Med.281055
59.
go back to reference Otto, D, Behrend, M, Börner, AR, et al. 2001Prospective PET study with 11C-methionine in patients with hyperparathyroidismEur. J. Nucl. Med.281056 Otto, D, Behrend, M, Börner, AR,  et al. 2001Prospective PET study with 11C-methionine in patients with hyperparathyroidismEur. J. Nucl. Med.281056
60.
go back to reference Sofferman, AR, Nathan, MD 1998The ectopic parathyroid adenoma. A cost justification for routine preoperative localization with 99mTc-Sestamibi scanArch. Otolaryngol. Head Neck Surg.124649654PubMed Sofferman, AR, Nathan, MD 1998The ectopic parathyroid adenoma. A cost justification for routine preoperative localization with 99mTc-Sestamibi scanArch. Otolaryngol. Head Neck Surg.124649654PubMed
Metadata
Title
Clinical Value of Parathyroid Scintigraphy with Technetium-99m Methoxyisobutylisonitrile: Discrepancies in Clinical Data and a Systematic Metaanalysis of the Literature
Authors
Martin Gotthardt, M.D.
Bodo Lohmann, M.D.
Thomas M. Behr, M.D.
Artur Bauhofer, Ph.D.
Christiane Franzius, M.D.
Meike L. Schipper, M.D.
Maria Wagner, M.D.
Helmut Höffken, M.D.
Helmut Sitter, Ph.D.
Matthias Rothmund, M.D.
Klaus Joseph, M.D.
Christoph Nies, M.D.
Publication date
01-01-2004
Publisher
Springer-Verlag
Published in
World Journal of Surgery / Issue 1/2004
Print ISSN: 0364-2313
Electronic ISSN: 1432-2323
DOI
https://doi.org/10.1007/s00268-003-6991-y

Other articles of this Issue 1/2004

World Journal of Surgery 1/2004 Go to the issue