Skip to main content
Top
Published in: Aesthetic Plastic Surgery 1/2011

01-02-2011 | Original Article

Rectus Diastasis Corrected with Absorbable Suture: A Long-Term Evaluation

Authors: Fabio Xerfan Nahas, Lydia Masako Ferreira, Pedro Bins Ely, Charles Ghelfond

Published in: Aesthetic Plastic Surgery | Issue 1/2011

Login to get access

Abstract

Background

Correction of rectus diastasis (RD) is performed during most abdominoplasties. This study aimed to evaluate the long-term result of RD correction when the plication of the anterior rectus sheath is performed with an absorbable suture.

Methods

Abdominoplasty was performed for 12 women who presented with Nahas’ type A musculoaponeurotic deformity. The RD was measured preoperatively with two computed tomography (CT) scan slices at two levels: 3 cm above and 2 cm below the umbilicus. The bony levels at which the slices were taken served as a reference for the postoperative CT scans. During the operation, the RD was measured with a ruler at the same levels as the preoperative CT scan slices. The force necessary to bring the medial edge of the rectus muscle to the midline was measured on both levels with a dynamometer. Plication of the anterior rectus sheath was performed using a double-layer 0-PDS (polydioxanone) suture. Postoperative CT scans were performed 3 weeks after the operation. A long-term follow-up CT scan was performed 32–48 months postoperatively for every patient.

Results

The 3-week postoperative CT scan proved that the correction of RD was achieved by the procedure. Despite the fact that there were different abdominal wall resistances and that the average weight gain during this period was 4.5 kg, the long-term CT-scans showed no recurrence of RD for any patient of this series in either the superior or inferior abdomen.

Conclusion

Plication of the anterior rectus sheath with PDS suture to correct RD seems to be a long-lasting procedure.
Footnotes
1
Personal communication: Product management. Ethicon Division of Johnson & Johnson Professional Products from Sao Paulo, SP, Brazil, 2009.
 
Literature
1.
go back to reference Nahas FX (1996) Studies on the endoscopic correction of diastasis recti. Oper Tech Plast Reconstr Surg 3:58CrossRef Nahas FX (1996) Studies on the endoscopic correction of diastasis recti. Oper Tech Plast Reconstr Surg 3:58CrossRef
2.
go back to reference Nahas FX, Ferreira LM (2003) Experimental model to study correction of rectus diastasis by laparoscopy, in pigs. Acta Cir Bras 18:69 Nahas FX, Ferreira LM (2003) Experimental model to study correction of rectus diastasis by laparoscopy, in pigs. Acta Cir Bras 18:69
3.
go back to reference Ferreira LM, Castilho HT, Hochberg J et al (2001) Triangular mattress suture in abdominal diastasis to prevent epigastric bulging. Ann Plast Surg 46:130CrossRefPubMed Ferreira LM, Castilho HT, Hochberg J et al (2001) Triangular mattress suture in abdominal diastasis to prevent epigastric bulging. Ann Plast Surg 46:130CrossRefPubMed
4.
go back to reference Birdsell DC, Gavelin GE, Kemsley GM, Hein KS (1981) “Staying power”: absorbable vs nonabsorbable. Plast Reconstr Surg 68:742CrossRefPubMed Birdsell DC, Gavelin GE, Kemsley GM, Hein KS (1981) “Staying power”: absorbable vs nonabsorbable. Plast Reconstr Surg 68:742CrossRefPubMed
5.
go back to reference Nahas FX, Augusto SM, Ghelfond C (1997) Should diastasis recti be corrected? Aesthetic Plast Surg 21:285CrossRefPubMed Nahas FX, Augusto SM, Ghelfond C (1997) Should diastasis recti be corrected? Aesthetic Plast Surg 21:285CrossRefPubMed
6.
go back to reference Nahas FX, Augusto SM, Ghelfond C (2001) Nylon versus PDS (polydioxanone) in the correction of rectus diastasis. Plast Reconstr Surg 107:700CrossRefPubMed Nahas FX, Augusto SM, Ghelfond C (2001) Nylon versus PDS (polydioxanone) in the correction of rectus diastasis. Plast Reconstr Surg 107:700CrossRefPubMed
7.
go back to reference Van Uchelen JH, Kon M, Werker PM (2001) The long-term durability of plication of the anterior rectus sheath assessed by ultrasonography. Plast Reconstr Surg 107:1578CrossRefPubMed Van Uchelen JH, Kon M, Werker PM (2001) The long-term durability of plication of the anterior rectus sheath assessed by ultrasonography. Plast Reconstr Surg 107:1578CrossRefPubMed
9.
go back to reference Nahas FX, Ferreira LM, Augusto SM, Ghelfond C (2005) Long term follow-up of correction of rectus diastasis. Plast Reconstr Surg 115:1736–1741CrossRefPubMed Nahas FX, Ferreira LM, Augusto SM, Ghelfond C (2005) Long term follow-up of correction of rectus diastasis. Plast Reconstr Surg 115:1736–1741CrossRefPubMed
10.
go back to reference Hodgson NC, Malthaner RA, Ostbye T (2000) The search for an ideal method of abdominal fascial closure: a meta-analysis. Ann Surg 231:436–442CrossRefPubMed Hodgson NC, Malthaner RA, Ostbye T (2000) The search for an ideal method of abdominal fascial closure: a meta-analysis. Ann Surg 231:436–442CrossRefPubMed
11.
go back to reference Nahas FX (2001) An aesthetic classification of the abdomen based on the myoaponeurotic layer. Plast Reconstr Surg 108:1787CrossRefPubMed Nahas FX (2001) An aesthetic classification of the abdomen based on the myoaponeurotic layer. Plast Reconstr Surg 108:1787CrossRefPubMed
12.
go back to reference Chang TN (2006) Abdominoplasty techniques. In: Mathes SJ (ed) Plastic surgery, vol 6, 1st edn. Saunders Elsevier, Philadelphia, pp 119–191 Chang TN (2006) Abdominoplasty techniques. In: Mathes SJ (ed) Plastic surgery, vol 6, 1st edn. Saunders Elsevier, Philadelphia, pp 119–191
13.
go back to reference Nahas FX, Barbosa MVJ, Ferreira LM (2009) Factors that may influence failure of the correction of the musculoaponeurotic deformities of the abdomen. Plast Reconstr Surg 124:334CrossRefPubMed Nahas FX, Barbosa MVJ, Ferreira LM (2009) Factors that may influence failure of the correction of the musculoaponeurotic deformities of the abdomen. Plast Reconstr Surg 124:334CrossRefPubMed
14.
15.
go back to reference Nahas FX, Ferreira LM, Mendes JA (2004) An efficient way to correct recurrent rectus diastasis. Aesthetic Plast Surg 28:189–196CrossRefPubMed Nahas FX, Ferreira LM, Mendes JA (2004) An efficient way to correct recurrent rectus diastasis. Aesthetic Plast Surg 28:189–196CrossRefPubMed
16.
go back to reference Mendes DA, Nahas FX, Veiga DF et al (2007) Ultrasonography for measuring rectus abdominis diastasis muscles. Acta Cir Bras 22:182–186CrossRefPubMed Mendes DA, Nahas FX, Veiga DF et al (2007) Ultrasonography for measuring rectus abdominis diastasis muscles. Acta Cir Bras 22:182–186CrossRefPubMed
Metadata
Title
Rectus Diastasis Corrected with Absorbable Suture: A Long-Term Evaluation
Authors
Fabio Xerfan Nahas
Lydia Masako Ferreira
Pedro Bins Ely
Charles Ghelfond
Publication date
01-02-2011
Publisher
Springer-Verlag
Published in
Aesthetic Plastic Surgery / Issue 1/2011
Print ISSN: 0364-216X
Electronic ISSN: 1432-5241
DOI
https://doi.org/10.1007/s00266-010-9554-2

Other articles of this Issue 1/2011

Aesthetic Plastic Surgery 1/2011 Go to the issue