Abstract

Purpose

To evaluate the risk factors correlated with loss of cemented vertebral body height after kyphoplasty in patients with osteoporotic vertebral compression fractures.

Methods

Thirty-four consecutive patients with single-level osteoporotic vertebral compression fractures who underwent kyphoplasty in the Affiliated Hospital of Jiangsu University between January 2012 and August 2014 were retrospectively analysed. Eight independent variables (age, gender, body mass index, pre-operative T-score in bone mineral density, the volume of polymethylmethacrylate injected, pre-operatively vertebral body height, the restoration of body height and the distance between polymethylmethacrylate and endplate) were assessed. The recompression of body height was the dependent variable. Multivariate linear regression analyses were used to determine the factors associated with recompression of body height.

Results

Multiple linear regression analyses indicated that the recompression of cemented vertebral body height was correlated with the distance between polymethylmethacrylate and endplate (P = 0.008, b’ = 0.489). The final multiple linear regression model, which included only the distance between polymethylmethacrylate and endplate, resulted in a formula that accounted for 41.02 % of the recompression of body height.

Conclusions

The distance between polymethylmethacrylate and endplate is an important risk factor of recompression of cemented vertebrae after kyphoplasty for patients with osteoporotic vertebral compression fractures.
Literature
3.
go back to reference Zou D, Zhang K, Ren Y (2015) Therapeutic effects of PKP on chronic painful osteoporotic vertebral compression fractures with or without intravertebral cleft. Int J Clin Exp Med 8(9):15780–15786PubMedPubMedCentral Zou D, Zhang K, Ren Y (2015) Therapeutic effects of PKP on chronic painful osteoporotic vertebral compression fractures with or without intravertebral cleft. Int J Clin Exp Med 8(9):15780–15786PubMedPubMedCentral
4.
go back to reference Lee SK, Lee SH, Yoon SP, Lee YT, Jang G, Lim SY, Lee HM, Moon SH, Song KS (2014) Quality of life comparison between vertebroplasty and kyphoplasty in patients with osteoporotic vertebral fractures. Asian Spine J 8(6):799–803CrossRefPubMedPubMedCentral Lee SK, Lee SH, Yoon SP, Lee YT, Jang G, Lim SY, Lee HM, Moon SH, Song KS (2014) Quality of life comparison between vertebroplasty and kyphoplasty in patients with osteoporotic vertebral fractures. Asian Spine J 8(6):799–803CrossRefPubMedPubMedCentral
8.
go back to reference Zhu SY, Zhong ZM, Wu Q, Chen JT (2016) Risk factors for bone cement leakage in percutaneous vertebroplasty: a retrospective study of four hundred and eighty five patients. Int Orthop. doi:10.1007/s00264-015-3102-2 Zhu SY, Zhong ZM, Wu Q, Chen JT (2016) Risk factors for bone cement leakage in percutaneous vertebroplasty: a retrospective study of four hundred and eighty five patients. Int Orthop. doi:10.​1007/​s00264-015-3102-2
9.
go back to reference Takahara K, Kamimura M, Moriya H, Ashizawa R, Koike T, Hidai Y, Ikegami S, Nakamura Y, Kato H (2016) Risk factors of adjacent vertebral collapse after percutaneous vertebroplasty for osteoporotic vertebral fracture in postmenopausal women. BMC Musculoskelet Disord 17(1):12. doi:10.1186/s12891-016-0887-0 CrossRefPubMedPubMedCentral Takahara K, Kamimura M, Moriya H, Ashizawa R, Koike T, Hidai Y, Ikegami S, Nakamura Y, Kato H (2016) Risk factors of adjacent vertebral collapse after percutaneous vertebroplasty for osteoporotic vertebral fracture in postmenopausal women. BMC Musculoskelet Disord 17(1):12. doi:10.​1186/​s12891-016-0887-0 CrossRefPubMedPubMedCentral
11.
go back to reference Balkarli H, Demirtas H, Kilic M, Ozturk I (2015) Treatment of osteoporotic vertebral compression fractures with percutaneous vertebroplasty under local anesthesia: clinical and radiological results. Int J Clin Exp Med 8(9):16287–16293PubMedPubMedCentral Balkarli H, Demirtas H, Kilic M, Ozturk I (2015) Treatment of osteoporotic vertebral compression fractures with percutaneous vertebroplasty under local anesthesia: clinical and radiological results. Int J Clin Exp Med 8(9):16287–16293PubMedPubMedCentral
12.
go back to reference Civelek E, Cansever T, Yilmaz C, Kabatas S, Gulsen S, Aydemir F, Altiotanors N, Caner H (2014) The retrospective analysis of the effect of balloon kyphoplasty to the adjacent-segment fracture in 171 patients. J Spinal Disord Tech 27(2):98–104CrossRefPubMed Civelek E, Cansever T, Yilmaz C, Kabatas S, Gulsen S, Aydemir F, Altiotanors N, Caner H (2014) The retrospective analysis of the effect of balloon kyphoplasty to the adjacent-segment fracture in 171 patients. J Spinal Disord Tech 27(2):98–104CrossRefPubMed
15.
go back to reference Zhai W, Jia Y, Wang J, Cheng L (2015) The clinical application and efficacy of percutaneous kyphoplasty via unilateral pedicular approach guided by CT image measurement. Int J Clin Exp Med 8(11):20861–20868PubMedPubMedCentral Zhai W, Jia Y, Wang J, Cheng L (2015) The clinical application and efficacy of percutaneous kyphoplasty via unilateral pedicular approach guided by CT image measurement. Int J Clin Exp Med 8(11):20861–20868PubMedPubMedCentral
16.
go back to reference Chang X, Lv YF, Chen B, Li HY, Han XB, Yang K, Zhang W, Zhou Y, Li CQ (2015) Vertebroplasty versus kyphoplasty in osteoporotic vertebral compression fracture: a meta-analysis of prospective comparative studies. Int Orthop 39(3):491–500. doi:10.1007/s00264-014-2525-5 CrossRefPubMed Chang X, Lv YF, Chen B, Li HY, Han XB, Yang K, Zhang W, Zhou Y, Li CQ (2015) Vertebroplasty versus kyphoplasty in osteoporotic vertebral compression fracture: a meta-analysis of prospective comparative studies. Int Orthop 39(3):491–500. doi:10.​1007/​s00264-014-2525-5 CrossRefPubMed
17.
go back to reference Niu J, Zhou H, Meng Q, Shi J, Meng B, Yang H (2015) Factors affecting recompression of augmented vertebrae after successful percutaneous balloon kyphoplasty: a retrospective analysis. Acta Radiol 56(11):1380–1387. doi:10.1177/0284185114556016 CrossRefPubMed Niu J, Zhou H, Meng Q, Shi J, Meng B, Yang H (2015) Factors affecting recompression of augmented vertebrae after successful percutaneous balloon kyphoplasty: a retrospective analysis. Acta Radiol 56(11):1380–1387. doi:10.​1177/​0284185114556016​ CrossRefPubMed
19.
go back to reference Boonen S, Van Meirhaeghe J, Bastian L, Cummings SR, Ranstam J, Tillman JB, Eastell R, Talmadge K, Wardlaw D (2011) Balloon kyphoplasty for the treatment of acute vertebral compression fractures: 2-year results from a randomized trial. J Bone Miner Res Off J Am Soc Bone Miner Res 26(7):1627–1637. doi:10.1002/jbmr.364 CrossRef Boonen S, Van Meirhaeghe J, Bastian L, Cummings SR, Ranstam J, Tillman JB, Eastell R, Talmadge K, Wardlaw D (2011) Balloon kyphoplasty for the treatment of acute vertebral compression fractures: 2-year results from a randomized trial. J Bone Miner Res Off J Am Soc Bone Miner Res 26(7):1627–1637. doi:10.​1002/​jbmr.​364 CrossRef
21.
go back to reference Zhai W, Jia Y, Wang J, Cheng L, Zeng Z, Yu Y, Chen L (2015) The clinical effect of percutaneous kyphoplasty for the treatment of multiple osteoporotic vertebral compression fractures and the prevention of new vertebral fractures. Int J Clin Exp Med 8(8):13473–13481PubMedPubMedCentral Zhai W, Jia Y, Wang J, Cheng L, Zeng Z, Yu Y, Chen L (2015) The clinical effect of percutaneous kyphoplasty for the treatment of multiple osteoporotic vertebral compression fractures and the prevention of new vertebral fractures. Int J Clin Exp Med 8(8):13473–13481PubMedPubMedCentral
23.
go back to reference Xiao H, Yang J, Feng X, Chen P, Li Y, Huang C, Liang Y, Chen H (2015) Comparing complications of vertebroplasty and kyphoplasty for treating osteoporotic vertebral compression fractures: a meta-analysis of the randomized and non-randomized controlled studies. Eur J Orthop Surg Traumatol 25(Suppl 1):S77–85. doi:10.1007/s00590-014-1502-4 CrossRefPubMed Xiao H, Yang J, Feng X, Chen P, Li Y, Huang C, Liang Y, Chen H (2015) Comparing complications of vertebroplasty and kyphoplasty for treating osteoporotic vertebral compression fractures: a meta-analysis of the randomized and non-randomized controlled studies. Eur J Orthop Surg Traumatol 25(Suppl 1):S77–85. doi:10.​1007/​s00590-014-1502-4 CrossRefPubMed
24.
go back to reference Abduljabbar FH, Al-Jurayyan A, Alqahtani S, Sardar ZM, Saluja RS, Ouellet J, Weber M, Steffen T, Beckman L, Jarzem P (2015) Does balloon kyphoplasty deliver more cement safely into osteoporotic vertebrae with compression fractures compared with vertebroplasty? A study in vertebral analogues. Glob Spine J 5(4):300–307. doi:10.1055/s-0035-1546818 CrossRef Abduljabbar FH, Al-Jurayyan A, Alqahtani S, Sardar ZM, Saluja RS, Ouellet J, Weber M, Steffen T, Beckman L, Jarzem P (2015) Does balloon kyphoplasty deliver more cement safely into osteoporotic vertebrae with compression fractures compared with vertebroplasty? A study in vertebral analogues. Glob Spine J 5(4):300–307. doi:10.​1055/​s-0035-1546818 CrossRef
Metadata
Title
Risk factors of recompression of cemented vertebrae after kyphoplasty for osteoporotic vertebral compression fractures
Authors
Dapeng Li
Yan Wu
Yonghui Huang
Balaara Augustine
Jiawei Yue
Publication date
01-06-2016
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 6/2016
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3203-6

Other articles of this Issue 6/2016

International Orthopaedics 6/2016 Go to the issue