Skip to main content
Top
Published in: International Orthopaedics 9/2015

01-09-2015 | Original Paper

High incidence of stem loosening in association with periprosthetic femur fractures in previously well-fixed cementless grit-blasted tapered-wedge stems

Authors: Seung-Jae Lim, Kyung-Jae Lee, Byung-Woo Min, Joo-Hyoun Song, Sang-Yeon So, Youn-Soo Park

Published in: International Orthopaedics | Issue 9/2015

Login to get access

Abstract

Purpose

Periprosthetic femur fracture is a potentially worrisome phenomenon for cementless stem fixation. The aim of this study was to document the incidence of stem loosening following periprosthetic femur fracture in previously well-fixed cementless grit-blasted tapered-wedge stems.

Methods

We identified 36 periprosthetic femur fractures of either Vancouver B1 or B2 following hip arthroplasties using cementless grit-blasted tapered-wedge titanium stems at three participating institutions (GB group). The control group consisted of 21 periprosthetic femur fractures of either Vancouver B1 or B2 following hip arthroplasties using cementless proximal porous-coated stems at the same institutions during the same period of study (PC group). All femoral stems had been in a well-fixed state before occurrence of fracture. All patients were treated surgically and femoral stem stability was assessed using preoperative radiographs and confirmed by intraoperative scrutinization.

Results

Seven (19.4 %) of 36 fractures were Vancouver B1 and 29 (80.6 %) were Vancouver B2 in the GB group, whereas 18 (85.7 %) of 21 fractures were Vancouver B1 and 3 (14.3 %) were Vancouver B2 in the PC group (P < 0.0001). The odds ratio for stem loosening was 24.86 (95 % CI, 5.69–108.63) in the GB group versus the PC group.

Conclusions

Hip arthroplasty using cementless grit-blasted tapered-wedge titanium stems showed higher incidence of stem loosening in association with periprosthetic femur fracture than hip arthroplasty conducted using proximal porous-coated stems. A high index of suspicion of stem loosening might be necessary in periprosthetic femur fracture following hip arthroplasty using this type of stems.
Literature
1.
go back to reference Delaunay C, Bonnomet F, North J, Jobard D, Cazeau C, Kempf JF (2001) Grit-blasted titanium femoral stem in cementless primary total hip arthroplasty: a 5- to 10-year multicenter study. J Arthroplast 16(1):47–54CrossRef Delaunay C, Bonnomet F, North J, Jobard D, Cazeau C, Kempf JF (2001) Grit-blasted titanium femoral stem in cementless primary total hip arthroplasty: a 5- to 10-year multicenter study. J Arthroplast 16(1):47–54CrossRef
2.
go back to reference Aldinger PR, Jung AW, Pritsch M et al (2009) Uncemented grit-blasted straight tapered titanium stems in patients younger than fifty-five years of age. Fifteen to twenty-year results. J Bone Joint Surg Am 91(6):1432–1439CrossRefPubMed Aldinger PR, Jung AW, Pritsch M et al (2009) Uncemented grit-blasted straight tapered titanium stems in patients younger than fifty-five years of age. Fifteen to twenty-year results. J Bone Joint Surg Am 91(6):1432–1439CrossRefPubMed
3.
go back to reference Sadoghi P, Janda W, Agreiter M, Rauf R, Leithner A, Labek G (2013) Pooled outcome of total hip arthroplasty with the CementLess Spotorno (CLS) system: a comparative analysis of clinical studies and worldwide arthroplasty register data. Int Orthop 37(6):995–999PubMedCentralCrossRefPubMed Sadoghi P, Janda W, Agreiter M, Rauf R, Leithner A, Labek G (2013) Pooled outcome of total hip arthroplasty with the CementLess Spotorno (CLS) system: a comparative analysis of clinical studies and worldwide arthroplasty register data. Int Orthop 37(6):995–999PubMedCentralCrossRefPubMed
4.
go back to reference Berry DJ (2003) Periprosthetic fractures associated with osteolysis: a problem on the rise. J Arthroplasty 18(3 Suppl 1):107–111CrossRefPubMed Berry DJ (2003) Periprosthetic fractures associated with osteolysis: a problem on the rise. J Arthroplasty 18(3 Suppl 1):107–111CrossRefPubMed
5.
go back to reference Lindahl H, Malchau H, Herberts P, Garellick G (2005) Periprosthetic femoral fractures classification and demographics of 1049 periprosthetic femoral fractures from the swedish national Hip arthroplasty register. J Arthoplast 20(7):857–865CrossRef Lindahl H, Malchau H, Herberts P, Garellick G (2005) Periprosthetic femoral fractures classification and demographics of 1049 periprosthetic femoral fractures from the swedish national Hip arthroplasty register. J Arthoplast 20(7):857–865CrossRef
6.
go back to reference Lindahl H, Garellick G, Regner H, Herberts P, Malchau H (2006) Three hundred and twenty-one periprosthetic femoral fractures. J Bone Joint Surg Am 88(6):1215–1222CrossRefPubMed Lindahl H, Garellick G, Regner H, Herberts P, Malchau H (2006) Three hundred and twenty-one periprosthetic femoral fractures. J Bone Joint Surg Am 88(6):1215–1222CrossRefPubMed
7.
go back to reference Meek RM, Norwood T, Smith R, Brenkel IJ, Howie CR (2011) The risk of peri-prosthetic fracture after primary and revision total hip and knee replacement. J Bone Joint Surg Br 93(1):96–101CrossRefPubMed Meek RM, Norwood T, Smith R, Brenkel IJ, Howie CR (2011) The risk of peri-prosthetic fracture after primary and revision total hip and knee replacement. J Bone Joint Surg Br 93(1):96–101CrossRefPubMed
8.
go back to reference Streit MR, Merle C, Clarius M, Aldinger PR (2011) Late peri-prosthetic femoral fracture as a major mode of failure in uncemented primary hip replacement. J Bone Joint Surg Br 93(2):178–183CrossRefPubMed Streit MR, Merle C, Clarius M, Aldinger PR (2011) Late peri-prosthetic femoral fracture as a major mode of failure in uncemented primary hip replacement. J Bone Joint Surg Br 93(2):178–183CrossRefPubMed
9.
go back to reference Lindahl H, Malchau H, Odén A, Garellick G (2006) Risk factors for failure after treatment of a periprosthetic fracture of the femur. J Bone Joint Surg Br 88(1):26–30CrossRefPubMed Lindahl H, Malchau H, Odén A, Garellick G (2006) Risk factors for failure after treatment of a periprosthetic fracture of the femur. J Bone Joint Surg Br 88(1):26–30CrossRefPubMed
10.
go back to reference Bhattacharyya T, Chang D, Meigs JB, Estok DM 2nd, Malchau H (2007) Mortality after periprosthetic fracture of the femur. J Bone Joint Surg Am 89(12):2658–2662CrossRefPubMed Bhattacharyya T, Chang D, Meigs JB, Estok DM 2nd, Malchau H (2007) Mortality after periprosthetic fracture of the femur. J Bone Joint Surg Am 89(12):2658–2662CrossRefPubMed
11.
go back to reference Bastian JD, Butscher A, Bigolin G, Zumstein MA, Nötzli HP (2014) Extracortical plate fixation with new plate inserts and cerclage wires for the treatment of periprosthetic hip fractures. Int Orthop 38(3):489–494PubMedCentralCrossRefPubMed Bastian JD, Butscher A, Bigolin G, Zumstein MA, Nötzli HP (2014) Extracortical plate fixation with new plate inserts and cerclage wires for the treatment of periprosthetic hip fractures. Int Orthop 38(3):489–494PubMedCentralCrossRefPubMed
12.
go back to reference Duncan CP, Masri BA (1995) Fractures of the femur after hip replacement. Instr Course Lect 44:293–304PubMed Duncan CP, Masri BA (1995) Fractures of the femur after hip replacement. Instr Course Lect 44:293–304PubMed
13.
go back to reference Learmonth ID (2004) The management of periprosthetic fractures around the femoral stem. J Bone Joint Surg Br 86(1):13–19PubMed Learmonth ID (2004) The management of periprosthetic fractures around the femoral stem. J Bone Joint Surg Br 86(1):13–19PubMed
14.
go back to reference Corten K, Vanrykel F, Bellemans J, Frederix PR, Simon JP, Broos PL (2009) An algorithm for the surgical treatment of periprosthetic fractures of the femur around a well-fixed femoral component. J Bone Joint Surg Br 91(11):1424–1430CrossRefPubMed Corten K, Vanrykel F, Bellemans J, Frederix PR, Simon JP, Broos PL (2009) An algorithm for the surgical treatment of periprosthetic fractures of the femur around a well-fixed femoral component. J Bone Joint Surg Br 91(11):1424–1430CrossRefPubMed
15.
go back to reference Mukundan C, Rayan F, Kheir E, Macdonald D (2010) Management of late periprosthetic femur fractures: a retrospective cohort of 72 patients. Int Orthop 34(4):485–489PubMedCentralCrossRefPubMed Mukundan C, Rayan F, Kheir E, Macdonald D (2010) Management of late periprosthetic femur fractures: a retrospective cohort of 72 patients. Int Orthop 34(4):485–489PubMedCentralCrossRefPubMed
16.
go back to reference Neumann D, Thaler C (2012) Dorn U (2012) Management of Vancouver B2 and B3 femoral periprosthetic fractures using a modular cementless stem without allografting. Int Orthop 36(5):1045–1050PubMedCentralCrossRefPubMed Neumann D, Thaler C (2012) Dorn U (2012) Management of Vancouver B2 and B3 femoral periprosthetic fractures using a modular cementless stem without allografting. Int Orthop 36(5):1045–1050PubMedCentralCrossRefPubMed
17.
go back to reference Brady OH, Garbuz DS, Masri BA, Duncan CP (1999) Classification of the hip. Orthop Clin North Am 30(2):215–220CrossRefPubMed Brady OH, Garbuz DS, Masri BA, Duncan CP (1999) Classification of the hip. Orthop Clin North Am 30(2):215–220CrossRefPubMed
18.
go back to reference Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH (1993) Structural and cellular assessment of bone quality of proximal femur. Bone 14(3):231–242CrossRefPubMed Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH (1993) Structural and cellular assessment of bone quality of proximal femur. Bone 14(3):231–242CrossRefPubMed
19.
go back to reference Min BW, Song KS, Bae KC, Cho CH, Kang CH, Kim SY (2008) The effect of stem alignment on results of total hip arthroplasty with a cementless tapered-wedge femoral component. J Arthroplasty 23(3):418–423CrossRefPubMed Min BW, Song KS, Bae KC, Cho CH, Kang CH, Kim SY (2008) The effect of stem alignment on results of total hip arthroplasty with a cementless tapered-wedge femoral component. J Arthroplasty 23(3):418–423CrossRefPubMed
20.
go back to reference Engh CA, Massin P, Suthers KE (1990) Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res 257:107–128PubMed Engh CA, Massin P, Suthers KE (1990) Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res 257:107–128PubMed
21.
go back to reference Cooper HJ, Rodriguez JA (2010) Early post-operative periprosthetic femur fracture in the presence of a non-cemented tapered wedge femoral stem. HSS J 6(2):150–154PubMedCentralCrossRefPubMed Cooper HJ, Rodriguez JA (2010) Early post-operative periprosthetic femur fracture in the presence of a non-cemented tapered wedge femoral stem. HSS J 6(2):150–154PubMedCentralCrossRefPubMed
22.
go back to reference Thomsen MN, Jakubowitz E, Seeger JB, Lee C, Kretzer JP, Clarius M (2008) Fracture load for periprosthetic femoral fractures in cemented versus uncemented hip stems: an experimental in vitro study. Orthopedics 31(7):653PubMed Thomsen MN, Jakubowitz E, Seeger JB, Lee C, Kretzer JP, Clarius M (2008) Fracture load for periprosthetic femoral fractures in cemented versus uncemented hip stems: an experimental in vitro study. Orthopedics 31(7):653PubMed
23.
go back to reference Maniatopoulos C, Pilliar RM, Smith DC (1986) Threaded versus porous-surfaced designs for implant stabilization in bone-endodontic implant model. J Biomed Mater Res 20(9):1309–1333CrossRefPubMed Maniatopoulos C, Pilliar RM, Smith DC (1986) Threaded versus porous-surfaced designs for implant stabilization in bone-endodontic implant model. J Biomed Mater Res 20(9):1309–1333CrossRefPubMed
24.
go back to reference Friedman RJ, An YH, Ming J, Draughn RA, Bauer TW (1996) Influence of biomaterial surface texture on bone ingrowth in the rabbit femur. J Orthop Res 14(3):455–464CrossRefPubMed Friedman RJ, An YH, Ming J, Draughn RA, Bauer TW (1996) Influence of biomaterial surface texture on bone ingrowth in the rabbit femur. J Orthop Res 14(3):455–464CrossRefPubMed
Metadata
Title
High incidence of stem loosening in association with periprosthetic femur fractures in previously well-fixed cementless grit-blasted tapered-wedge stems
Authors
Seung-Jae Lim
Kyung-Jae Lee
Byung-Woo Min
Joo-Hyoun Song
Sang-Yeon So
Youn-Soo Park
Publication date
01-09-2015
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 9/2015
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-014-2586-5