Skip to main content
Top
Published in: International Orthopaedics 3/2011

01-03-2011 | Original Paper

Surgical treatment of syndesmotic diastasis: emphasis on effect of syndesmotic screw on ankle function

Authors: Yi-Ton Hsu, Chi-Chuan Wu, Wei-Cheun Lee, Kuo-Feng Fan, I-Chuan Tseng, Po-Cheng Lee

Published in: International Orthopaedics | Issue 3/2011

Login to get access

Abstract

Fifty-two consecutive adult patients with syndesmotic diastasis (SD) were treated with closed anatomical reduction and stable fixation by a trans-syndesmotic cancellous screw. A short leg splint was prescribed for a six week postoperative period. Treatment outcomes of syndesmotic screw removal at various time points were studied and compared (group 1 at six weeks, group 2 at three months and group 3 at an average of nine months). Recurrence of SD, incidence of syndesmotic screw breakage and ankle function were compared among the three groups. Recurrence of SD occurred in 15.8% (3/19) of patients in group 1, 15.0% (3/20) in group 2 and 0% (0/13) in group 3 (p = 0.054). Breakage of the syndesmotic screw occurred in three patients within three months (group 2, 15.0%) and in two patients beyond three months (group 3, each at six and 12 months, 15.4%). None of the group 1 patients experienced screw breakage (p = 0.034). Forty-three patients (82.7%) were classified as having satisfactory outcomes. Ankle function did not significantly differ among the three groups (p = 0.191), with or without syndesmotic screw breakage (p = 0.343) and with or without SD recurrence (p = 0.218). In conclusion, restriction of daily activity for at least three months is required to prevent recurrence. Removal of the syndesmotic screw at six weeks may prevent its breakage but increases the risk of recurrence. Over an average follow-up of 19 months, SD recurrence does not lead to deterioration in ankle function.
Literature
1.
go back to reference Bauer M, Bergström B, Hemborg A, Sandegård J (1985) Malleolar fractures: nonoperative versus operative treatment. A controlled study. Clin Orthop Relat Res 199:17–27PubMed Bauer M, Bergström B, Hemborg A, Sandegård J (1985) Malleolar fractures: nonoperative versus operative treatment. A controlled study. Clin Orthop Relat Res 199:17–27PubMed
2.
go back to reference Bone LB (1987) Fractures of the tibial plafond. The pilon fracture. Orthop Clin North Am 18:95–104PubMed Bone LB (1987) Fractures of the tibial plafond. The pilon fracture. Orthop Clin North Am 18:95–104PubMed
3.
go back to reference Bray TJ, Endicott M, Capra SE (1989) Treatment of open ankle fractures. Immediate internal fixation versus closed immobilization and delayed fixation. Clin Orthop Relat Res 240:47–52PubMed Bray TJ, Endicott M, Capra SE (1989) Treatment of open ankle fractures. Immediate internal fixation versus closed immobilization and delayed fixation. Clin Orthop Relat Res 240:47–52PubMed
4.
go back to reference Cheng W, Li Y, Manyi W (2010) Comparison study of two surgical options for distal tibia fracture-minimally invasive plate osteosynthesis vs. open reduction and internal fixation. Int Orthop June 2 (Epub ahead of print) Cheng W, Li Y, Manyi W (2010) Comparison study of two surgical options for distal tibia fracture-minimally invasive plate osteosynthesis vs. open reduction and internal fixation. Int Orthop June 2 (Epub ahead of print)
5.
go back to reference Dattani R, Patnaik S, Kantak A, Srikanth B, Selvan TP (2008) Injuries to the tibiofibular syndesmosis. J Bone Joint Surg Br 90:405–410PubMedCrossRef Dattani R, Patnaik S, Kantak A, Srikanth B, Selvan TP (2008) Injuries to the tibiofibular syndesmosis. J Bone Joint Surg Br 90:405–410PubMedCrossRef
6.
go back to reference Donatelli R (1985) Normal biomechanics of the foot and ankle. J Orthop Sports Phys Ther 7:91–95PubMed Donatelli R (1985) Normal biomechanics of the foot and ankle. J Orthop Sports Phys Ther 7:91–95PubMed
7.
go back to reference Egol KA, Pahk B, Walsh M, Tejwani NC, Davidovitch RI, Koval KJ (2010) Outcome after unstable ankle fracture: effect of syndesmotic stabilization. J Orthop Trauma 24:7–11PubMedCrossRef Egol KA, Pahk B, Walsh M, Tejwani NC, Davidovitch RI, Koval KJ (2010) Outcome after unstable ankle fracture: effect of syndesmotic stabilization. J Orthop Trauma 24:7–11PubMedCrossRef
8.
go back to reference Fogel GR, Morrey BF (1987) Delayed open reduction and fixation of ankle fractures. Clin Orthop Relat Res 215:187–195PubMed Fogel GR, Morrey BF (1987) Delayed open reduction and fixation of ankle fractures. Clin Orthop Relat Res 215:187–195PubMed
9.
go back to reference Frankel VH, Nordin M (1989) Biomechanics of the ankle. In: Nordin M, Frankel VH (eds) Basic biomechanics of the musculoskeletal system, 7th edn. Lea & Febiger, Philadelphia, pp 153–161 Frankel VH, Nordin M (1989) Biomechanics of the ankle. In: Nordin M, Frankel VH (eds) Basic biomechanics of the musculoskeletal system, 7th edn. Lea & Febiger, Philadelphia, pp 153–161
10.
go back to reference Hamid N, Loeffler BJ, Braddy W, Kellam JF, Cohen BE, Bosse MJ (2009) Outcome after fixation of ankle fractures with an injury to the syndesmosis: the effect of the syndesmosis screw. J Bone Joint Surg Br 91:1069–1073PubMedCrossRef Hamid N, Loeffler BJ, Braddy W, Kellam JF, Cohen BE, Bosse MJ (2009) Outcome after fixation of ankle fractures with an injury to the syndesmosis: the effect of the syndesmosis screw. J Bone Joint Surg Br 91:1069–1073PubMedCrossRef
11.
go back to reference Hughes LY (1985) Biomechanical analysis of the foot and ankle for predisposition to developing stress fractures. J Orthop Sports Phys Ther 7:96–101PubMed Hughes LY (1985) Biomechanical analysis of the foot and ankle for predisposition to developing stress fractures. J Orthop Sports Phys Ther 7:96–101PubMed
12.
go back to reference Lee YS, Hsu TL, Huang CR, Chen SH (2010) Lateral fixation of AO type-B2 ankle fractures: the Acutrak plus compression screw technique. Int Orthop 34:903–907PubMedCrossRef Lee YS, Hsu TL, Huang CR, Chen SH (2010) Lateral fixation of AO type-B2 ankle fractures: the Acutrak plus compression screw technique. Int Orthop 34:903–907PubMedCrossRef
13.
go back to reference Manjoo A, Sanders DW, Tieszer C, MacLeod MD (2010) Functional and radiographic results of patients with syndesmotic screw fixation: implications for screw removal. J Orthop Trauma 24:2–6PubMedCrossRef Manjoo A, Sanders DW, Tieszer C, MacLeod MD (2010) Functional and radiographic results of patients with syndesmotic screw fixation: implications for screw removal. J Orthop Trauma 24:2–6PubMedCrossRef
14.
go back to reference Marks R (2005) Foot and ankle trauma. In: Vaccaro AR (ed) Orthopedic knowledge update 8, vol 2. American Academy of Orthopedic Surgeons, Rosemont, pp 471–485 Marks R (2005) Foot and ankle trauma. In: Vaccaro AR (ed) Orthopedic knowledge update 8, vol 2. American Academy of Orthopedic Surgeons, Rosemont, pp 471–485
15.
go back to reference Marsh JL, Saltzman CL (2006) Ankle fractures. In: Bucholz RW, Heckman JB, Court-Brown C (eds) Rockwood and Green’s fractures in adults, vol 2, 6th edn. Lippincott Williams & Wilkins, Philadelphia, pp 2147–2247 Marsh JL, Saltzman CL (2006) Ankle fractures. In: Bucholz RW, Heckman JB, Court-Brown C (eds) Rockwood and Green’s fractures in adults, vol 2, 6th edn. Lippincott Williams & Wilkins, Philadelphia, pp 2147–2247
16.
go back to reference Melvin JS, Downing KL, Ogilvie CM (2008) A technique for removal of broken cannulated tricortical syndesmotic screws. J Orthop Trauma 22:648–651PubMedCrossRef Melvin JS, Downing KL, Ogilvie CM (2008) A technique for removal of broken cannulated tricortical syndesmotic screws. J Orthop Trauma 22:648–651PubMedCrossRef
17.
go back to reference Michelson JD (1995) Current concepts review: fractures about the ankle. J Bone Joint Surg Am 77:142–152PubMed Michelson JD (1995) Current concepts review: fractures about the ankle. J Bone Joint Surg Am 77:142–152PubMed
18.
go back to reference Miller AN, Paul O, Boraiah S, Parker RJ, Helfet DL, Lorich DG (2010) Functional outcomes after syndesmotic screw fixation and removal. J Orthop Trauma 24:12–16PubMedCrossRef Miller AN, Paul O, Boraiah S, Parker RJ, Helfet DL, Lorich DG (2010) Functional outcomes after syndesmotic screw fixation and removal. J Orthop Trauma 24:12–16PubMedCrossRef
19.
go back to reference Nousiainen MT, McConnell AJ, Zdero R, McKee MD, Bhandari M, Schemitsch EH (2008) The influence of the number of cortices of screw purchase and ankle position in Weber C ankle fracture fixation. J Orthop Trauma 22:473–478PubMedCrossRef Nousiainen MT, McConnell AJ, Zdero R, McKee MD, Bhandari M, Schemitsch EH (2008) The influence of the number of cortices of screw purchase and ankle position in Weber C ankle fracture fixation. J Orthop Trauma 22:473–478PubMedCrossRef
20.
go back to reference Sanders DA, Sirkin M (2005) Fractures of the ankle and distal tibial pilon. In: Baumgaertner MR, Tornetta P III (eds) Orthopedic knowledge update trauma 3. American Academy of Orthopedic Surgeons, Rosemont, pp 441–452 Sanders DA, Sirkin M (2005) Fractures of the ankle and distal tibial pilon. In: Baumgaertner MR, Tornetta P III (eds) Orthopedic knowledge update trauma 3. American Academy of Orthopedic Surgeons, Rosemont, pp 441–452
21.
go back to reference Schaffer JJ, Manoli A II (1987) The antiglide plate for distal fibular fixation. A biomechanical comparison with fixation with a lateral plate. J Bone Joint Surg Am 69:596–604PubMed Schaffer JJ, Manoli A II (1987) The antiglide plate for distal fibular fixation. A biomechanical comparison with fixation with a lateral plate. J Bone Joint Surg Am 69:596–604PubMed
22.
go back to reference Stark E, Tornetta P III, Creevy WR (2007) Syndesmotic instability in Weber B ankle fractures: a clinical evaluation. J Orthop Trauma 21:643–646PubMedCrossRef Stark E, Tornetta P III, Creevy WR (2007) Syndesmotic instability in Weber B ankle fractures: a clinical evaluation. J Orthop Trauma 21:643–646PubMedCrossRef
23.
go back to reference Stiehl JB (1990) Complex ankle fracture dislocations with syndesmotic diastasis. Orthop Rev 19:499–507PubMed Stiehl JB (1990) Complex ankle fracture dislocations with syndesmotic diastasis. Orthop Rev 19:499–507PubMed
24.
go back to reference Stoffel K, Wysocki D, Baddour E, Nicholls R, Yates P (2009) Comparison of two intraoperative assessment methods for injuries to the ankle syndesmosis. A cadaveric study. J Bone Joint Surg Am 91:2646–2652PubMedCrossRef Stoffel K, Wysocki D, Baddour E, Nicholls R, Yates P (2009) Comparison of two intraoperative assessment methods for injuries to the ankle syndesmosis. A cadaveric study. J Bone Joint Surg Am 91:2646–2652PubMedCrossRef
25.
go back to reference Whittle AP (2008) Fractures of the lower extremity. In: Canale ST, Beaty JH (eds) Campbell’s operative orthopedics, vol 3, 11th edn. Mosby, Philadelphia, pp 3085–3237 Whittle AP (2008) Fractures of the lower extremity. In: Canale ST, Beaty JH (eds) Campbell’s operative orthopedics, vol 3, 11th edn. Mosby, Philadelphia, pp 3085–3237
26.
go back to reference Wikerøy AKB, Høiness PR, Andreassen GS, Hellund JC, Madsen JE (2010) No difference in functional and radiographic results 8.4 years after quadricortical compared with tricortical syndesmosis fixation in ankle fractures. J Orthop Trauma 24:17–23PubMedCrossRef Wikerøy AKB, Høiness PR, Andreassen GS, Hellund JC, Madsen JE (2010) No difference in functional and radiographic results 8.4 years after quadricortical compared with tricortical syndesmosis fixation in ankle fractures. J Orthop Trauma 24:17–23PubMedCrossRef
Metadata
Title
Surgical treatment of syndesmotic diastasis: emphasis on effect of syndesmotic screw on ankle function
Authors
Yi-Ton Hsu
Chi-Chuan Wu
Wei-Cheun Lee
Kuo-Feng Fan
I-Chuan Tseng
Po-Cheng Lee
Publication date
01-03-2011
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 3/2011
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-010-1147-9

Other articles of this Issue 3/2011

International Orthopaedics 3/2011 Go to the issue