Skip to main content
Top
Published in: International Orthopaedics 3/2010

01-03-2010 | Original Paper

Revision of total hip arthroplasty using the Kerboull and KT plates

Authors: Tomonori Baba, Katsuo Shitoto

Published in: International Orthopaedics | Issue 3/2010

Login to get access

Abstract

We reviewed 42 hips which had undergone revision THA between 1995 and 2005 (the Kerboull plate in 24 hips, and the KT plate in 18 hips). Patients were followed-up for a mean of 7.5 years (range 3–13). In the Kerboull plate group, the five- and ten-year survival rates were 89.9% and 79.4%, respectively. In the KT plate group, the five-year survival rate was 87.5%. The Kerboull and KT plates are placed as close as possible to the original acetabular position and used in combination with a bone graft for bone defects. In Japan, for patients with large bone defects, femoral heads with good quality which have been resected due to osteoarthritis are difficult to prepare as bone grafts. Therefore, use of the KT plate can reduce the bone graft volume to a certain extent by high placement, which was effective in our cases.
Literature
1.
go back to reference Amstutz HC, Ma SM, Jinnah RH et al (1982) Revision of aseptic loose total hip arthroplasties. Clin Orthop 170:21–23PubMed Amstutz HC, Ma SM, Jinnah RH et al (1982) Revision of aseptic loose total hip arthroplasties. Clin Orthop 170:21–23PubMed
2.
go back to reference Pellicci PM, Wilson PD Jr, Sledge CB et al (1982) Revision of total hip arthroplasty. Clin Orthop 170:34–41PubMed Pellicci PM, Wilson PD Jr, Sledge CB et al (1982) Revision of total hip arthroplasty. Clin Orthop 170:34–41PubMed
3.
go back to reference Kavanagh BF, Ilstrup DM, Fitzgerald RH (1985) Revision of total hip arthroplasty. J Bone Joint Surg Am 67:517–526PubMed Kavanagh BF, Ilstrup DM, Fitzgerald RH (1985) Revision of total hip arthroplasty. J Bone Joint Surg Am 67:517–526PubMed
4.
go back to reference Yoder SA, Brand RA, Pedersen DR et al (1988) Total hip acetabular component position affects component loosening rates. Clin Orthop 228:79–87PubMed Yoder SA, Brand RA, Pedersen DR et al (1988) Total hip acetabular component position affects component loosening rates. Clin Orthop 228:79–87PubMed
5.
go back to reference Kerboull M, Hamadouche M, Kerboull L (2000) The Kerboull acetabular reinforcement device in major acetabular reconstructions. Clin Orthop 378:155–168CrossRefPubMed Kerboull M, Hamadouche M, Kerboull L (2000) The Kerboull acetabular reinforcement device in major acetabular reconstructions. Clin Orthop 378:155–168CrossRefPubMed
6.
go back to reference Tanaka C, Shikata J, Ikenaga M et al (2003) Acetabular reconstruction using a Kerboull-type acetabular reinforcement granules. J Arthroplasty 18:719–725CrossRefPubMed Tanaka C, Shikata J, Ikenaga M et al (2003) Acetabular reconstruction using a Kerboull-type acetabular reinforcement granules. J Arthroplasty 18:719–725CrossRefPubMed
7.
go back to reference D’Antonio JA, Capello WN, Borden LS et al (1989) Classification and management of acetabular abnormalities in total hip arthroplasty. Clin Orthop 243:126PubMed D’Antonio JA, Capello WN, Borden LS et al (1989) Classification and management of acetabular abnormalities in total hip arthroplasty. Clin Orthop 243:126PubMed
8.
go back to reference Kokubo T, Shigematsu M, Nagashima Y et al (1982) Apatite- and wollastonite-containing glass-ceramics for prosthetic application. Bull Inst Chem Res, Kyoto Univ 60:260–268 Kokubo T, Shigematsu M, Nagashima Y et al (1982) Apatite- and wollastonite-containing glass-ceramics for prosthetic application. Bull Inst Chem Res, Kyoto Univ 60:260–268
9.
go back to reference Oonishi H, Yamamoto M, Ishimaru H et al (1989) The effect of hydroxyapatite coating on bone growth into porous titanium alloy implants. J Bone Joint Surg Br 71:213–216PubMed Oonishi H, Yamamoto M, Ishimaru H et al (1989) The effect of hydroxyapatite coating on bone growth into porous titanium alloy implants. J Bone Joint Surg Br 71:213–216PubMed
11.
go back to reference Merled’Aubigné PM (1954) Functional result of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 36:451–475 Merled’Aubigné PM (1954) Functional result of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 36:451–475
12.
go back to reference DeLee JG, Chanley J (1976) Radiological demarcation of cemented socket in total hip replacement. Clin Orthop 121:20–32PubMed DeLee JG, Chanley J (1976) Radiological demarcation of cemented socket in total hip replacement. Clin Orthop 121:20–32PubMed
13.
go back to reference Kawanabe K, Akiyama H, Onishi E et al (2007) Revision total hip replacement using the Kerboull acetabular reinforcement device with morsellised or bulk graft. J Bone Joint Surg Br 89:26–31PubMed Kawanabe K, Akiyama H, Onishi E et al (2007) Revision total hip replacement using the Kerboull acetabular reinforcement device with morsellised or bulk graft. J Bone Joint Surg Br 89:26–31PubMed
14.
go back to reference Lunn JV, Kearns SS, Quinlan W et al (2005) Impaction allografting and the Kerboull acetabular reinforcement device. Acta Orthop 76:296–302PubMed Lunn JV, Kearns SS, Quinlan W et al (2005) Impaction allografting and the Kerboull acetabular reinforcement device. Acta Orthop 76:296–302PubMed
15.
go back to reference Dearborn JT, Harris WH (1999) High placement of an acetabular component inserted without cement in a revision total hip arthroplasty. J Bone Joint Surg Am 81:469–480PubMed Dearborn JT, Harris WH (1999) High placement of an acetabular component inserted without cement in a revision total hip arthroplasty. J Bone Joint Surg Am 81:469–480PubMed
16.
go back to reference Manabe T, Mori S, Iwata K et al (2005) Revision total hip arthroplasty with allograft. Chubu Seikaisi 17:163–166 Manabe T, Mori S, Iwata K et al (2005) Revision total hip arthroplasty with allograft. Chubu Seikaisi 17:163–166
Metadata
Title
Revision of total hip arthroplasty using the Kerboull and KT plates
Authors
Tomonori Baba
Katsuo Shitoto
Publication date
01-03-2010
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 3/2010
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-009-0789-y

Other articles of this Issue 3/2010

International Orthopaedics 3/2010 Go to the issue