Skip to main content
Top
Published in: International Orthopaedics 3/2010

01-03-2010 | Original Paper

Alendronate treatment improves bone–pedicle screw interface fixation in posterior lateral spine fusion: An experimental study in a porcine model

Authors: Qingyun Xue, Haisheng Li, Xuenong Zou, Michel Dalstra, Martin Lind, Finn B. Christensen, Cody Bünger

Published in: International Orthopaedics | Issue 3/2010

Login to get access

Abstract

The bone–screw interface has been indicated as the weak link in pedicle screw spine fixation. Bisphosphonate treatment may have the effect of improving bone–screw interface fixation in spine fusion by inhibiting bone resorption. An experimental study was conducted using a porcine model to evaluate the influence of alendronate treatment on bone–pedicle screw interface fixation. Eleven pigs in the treatment group received alendronate 10 mg/day orally for three months postoperatively. The other 11 pigs served as a control group. Posterior lateral fusion with the CD Horizon pedicle screw system was performed with autograft on the lumbar spine on all animals. Biomechanical torsion test and histomorphometric parameters of screw fixation were evaluated three months after the operation. The maximum torque and initial angular stiffness of the treatment group was higher than that of the control group, but there was no statistical significance. The bone–screw contact surface was 23.3 ± 10% for the treatment group and 9.8 ± 5.9% for the control group (P < 0.01). This study indicated that alendronate treatment increased bone purchase of stainless steel screw surfaces.
Literature
1.
go back to reference Chapman JR, Harrington RM, Lee KM (1996) Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng 118:391–398CrossRefPubMed Chapman JR, Harrington RM, Lee KM (1996) Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng 118:391–398CrossRefPubMed
2.
go back to reference Christensen FB, Dalstra M, Sejling F (2000) Titanium-alloy enhances bone-pedicle screw fixation: mechanical and histomorphometrical results of titanium-alloy versus stainless steel. Eur Spine J 9:97–103CrossRefPubMed Christensen FB, Dalstra M, Sejling F (2000) Titanium-alloy enhances bone-pedicle screw fixation: mechanical and histomorphometrical results of titanium-alloy versus stainless steel. Eur Spine J 9:97–103CrossRefPubMed
3.
go back to reference Davne SH, Myers DL (1992) Complications of lumbar spinal fusion with transpedicular instrumentation. Spine 17:S184–S189CrossRefPubMed Davne SH, Myers DL (1992) Complications of lumbar spinal fusion with transpedicular instrumentation. Spine 17:S184–S189CrossRefPubMed
4.
go back to reference DeCoster TA, Heetderks DB, Downey DJ (1990) Optimizing bone screw pullout force. J Orthop Trauma 4:169–174CrossRefPubMed DeCoster TA, Heetderks DB, Downey DJ (1990) Optimizing bone screw pullout force. J Orthop Trauma 4:169–174CrossRefPubMed
5.
go back to reference Dickman CA, Fessler RG, MacMillan M (1992) Transpedicular screw-rod fixation of the lumbar spine: operative technique and outcome in 104 cases. J Neurosurg 77:860–870CrossRefPubMed Dickman CA, Fessler RG, MacMillan M (1992) Transpedicular screw-rod fixation of the lumbar spine: operative technique and outcome in 104 cases. J Neurosurg 77:860–870CrossRefPubMed
6.
go back to reference Frenkel SR, Jaffe WL, Valle CD et al (2001) The effect of alendronate (Fosamax) and implant surface on bone integration and remodeling in a canine model. J Biomed Mater Res 58:645–650CrossRefPubMed Frenkel SR, Jaffe WL, Valle CD et al (2001) The effect of alendronate (Fosamax) and implant surface on bone integration and remodeling in a canine model. J Biomed Mater Res 58:645–650CrossRefPubMed
7.
go back to reference George DC, Krag MH, Johnson CC (1991) Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae. Spine 16:181–184PubMed George DC, Krag MH, Johnson CC (1991) Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae. Spine 16:181–184PubMed
8.
go back to reference Gundersen HJ, Jensen EB (1987) The efficiency of systematic sampling in stereology and its prediction. J Microsc 147(Pt 3):229–263PubMed Gundersen HJ, Jensen EB (1987) The efficiency of systematic sampling in stereology and its prediction. J Microsc 147(Pt 3):229–263PubMed
9.
go back to reference Hilding M, Ryd L, Toksvig-Larsen S (2000) Clodronate prevents prosthetic migration: a randomized radiostereometric study of 50 total knee patients. Acta Orthop Scand 71:553–557PubMed Hilding M, Ryd L, Toksvig-Larsen S (2000) Clodronate prevents prosthetic migration: a randomized radiostereometric study of 50 total knee patients. Acta Orthop Scand 71:553–557PubMed
10.
go back to reference Jacobs JJ, Sumner DR, Galante JO (1993) Mechanisms of bone loss associated with total hip replacement. Orthop Clin North Am 24:583–590PubMed Jacobs JJ, Sumner DR, Galante JO (1993) Mechanisms of bone loss associated with total hip replacement. Orthop Clin North Am 24:583–590PubMed
11.
go back to reference Krag MH (1990) Spinal instrumentation: biomechanics of transpedicle spinal fixation. In: Weinstein JN, Wiesel SW (eds) In the lumbar spine. W.B. Saunders, Philadelphia, pp 916–940 Krag MH (1990) Spinal instrumentation: biomechanics of transpedicle spinal fixation. In: Weinstein JN, Wiesel SW (eds) In the lumbar spine. W.B. Saunders, Philadelphia, pp 916–940
12.
go back to reference Krag MH, Beynnon BD, Pope MH (1988) Depth of insertion of transpedicular vertebral screws into human vertebrae: effect upon screw-vertebra interface strength. J Spinal Disord 1:287–294CrossRefPubMed Krag MH, Beynnon BD, Pope MH (1988) Depth of insertion of transpedicular vertebral screws into human vertebrae: effect upon screw-vertebra interface strength. J Spinal Disord 1:287–294CrossRefPubMed
13.
go back to reference Kwok AW, Finkelstein JA, Woodside T (1996) Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone. Spine 21:2429–2434CrossRefPubMed Kwok AW, Finkelstein JA, Woodside T (1996) Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone. Spine 21:2429–2434CrossRefPubMed
14.
go back to reference Li J, Mori S, Kaji Y (2000) Concentration of bisphosphonate (incadronate) in callus area and its effects on fracture healing in rats. J Bone Miner Res 15:2042–2051CrossRefPubMed Li J, Mori S, Kaji Y (2000) Concentration of bisphosphonate (incadronate) in callus area and its effects on fracture healing in rats. J Bone Miner Res 15:2042–2051CrossRefPubMed
15.
go back to reference Luckman SP, Hughes DE, Coxon FP (1998) Nitrogen-containing bisphosphonates inhibit the mevalonate pathway and prevent post-translational prenylation of GTP-binding proteins, including Ras. J Bone Miner Res 13:581–589CrossRefPubMed Luckman SP, Hughes DE, Coxon FP (1998) Nitrogen-containing bisphosphonates inhibit the mevalonate pathway and prevent post-translational prenylation of GTP-binding proteins, including Ras. J Bone Miner Res 13:581–589CrossRefPubMed
16.
go back to reference Lugero GG, de Falco Caparbo V, Guzzo ML (2000) Histomorphometric evaluation of titanium implants in osteoporotic rabbits. Implant Dent 9:303–309CrossRefPubMed Lugero GG, de Falco Caparbo V, Guzzo ML (2000) Histomorphometric evaluation of titanium implants in osteoporotic rabbits. Implant Dent 9:303–309CrossRefPubMed
17.
go back to reference Mochida Y, Bauer TW, Akisue T (2002) Alendronate does not inhibit early bone apposition to hydroxyapatite-coated total joint implants: a preliminary study. J Bone Joint Surg 84A:226–235 Mochida Y, Bauer TW, Akisue T (2002) Alendronate does not inhibit early bone apposition to hydroxyapatite-coated total joint implants: a preliminary study. J Bone Joint Surg 84A:226–235
18.
go back to reference Ohlin A, Karlsson M, Duppe H (1994) Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases. Spine 19:2774–2779CrossRefPubMed Ohlin A, Karlsson M, Duppe H (1994) Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases. Spine 19:2774–2779CrossRefPubMed
19.
go back to reference Petersen MM, Lauritzen JB, Pedersen JG (1996) Decreased bone density of the distal femur after uncemented knee arthroplasty. A 1-year follow-up of 29 knees. Acta Orthop Scand 67:339–344PubMed Petersen MM, Lauritzen JB, Pedersen JG (1996) Decreased bone density of the distal femur after uncemented knee arthroplasty. A 1-year follow-up of 29 knees. Acta Orthop Scand 67:339–344PubMed
20.
go back to reference Pihlajamaki H, Myllynen P, Bostman O (1997) Complications of transpedicular lumbosacral fixation for non-traumatic disorders. J Bone Joint Surg Br 79:183–189CrossRef Pihlajamaki H, Myllynen P, Bostman O (1997) Complications of transpedicular lumbosacral fixation for non-traumatic disorders. J Bone Joint Surg Br 79:183–189CrossRef
21.
go back to reference Russell RG, Rogers MJ (1999) Bisphosphonates: from the laboratory to the clinic and back again. Bone 25:97–106CrossRefPubMed Russell RG, Rogers MJ (1999) Bisphosphonates: from the laboratory to the clinic and back again. Bone 25:97–106CrossRefPubMed
22.
go back to reference Sanden B, Olerud C, Johansson C (2001) Improved bone-screw interface with hydroxyapatite coating: an in vivo study of loaded pedicle screws in sheep. Spine 26:2673–2678CrossRefPubMed Sanden B, Olerud C, Johansson C (2001) Improved bone-screw interface with hydroxyapatite coating: an in vivo study of loaded pedicle screws in sheep. Spine 26:2673–2678CrossRefPubMed
23.
go back to reference Soininvaara TA, Jurvelin JS, Miettinen HJ (2002) Effect of alendronate on periprosthetic bone loss after total knee arthroplasty: a one-year, randomized, controlled trial of 19 patients. Calcif Tissue Int 71:472–477CrossRefPubMed Soininvaara TA, Jurvelin JS, Miettinen HJ (2002) Effect of alendronate on periprosthetic bone loss after total knee arthroplasty: a one-year, randomized, controlled trial of 19 patients. Calcif Tissue Int 71:472–477CrossRefPubMed
24.
go back to reference Tokugawa Y, Shirota T, Ohno K (2003) Effects of bisphosphonate on bone reaction after placement of titanium implants in tibiae of ovariectomized rats. Int J Oral Maxillofac Implants 18:66–74PubMed Tokugawa Y, Shirota T, Ohno K (2003) Effects of bisphosphonate on bone reaction after placement of titanium implants in tibiae of ovariectomized rats. Int J Oral Maxillofac Implants 18:66–74PubMed
25.
go back to reference Tonino RP, Meunier PJ, Emkey R et al (2000) Skeletal benefits of alendronate: 7-year treatment of postmenopausal osteoporotic women. Phase III Osteoporosis Treatment Study Group. J Clin Endocrinol Metab 85:3109–3115CrossRefPubMed Tonino RP, Meunier PJ, Emkey R et al (2000) Skeletal benefits of alendronate: 7-year treatment of postmenopausal osteoporotic women. Phase III Osteoporosis Treatment Study Group. J Clin Endocrinol Metab 85:3109–3115CrossRefPubMed
26.
go back to reference Venesmaa PK, Kroger HP, Jurvelin JS (2003) Periprosthetic bone loss after cemented total hip arthroplasty: a prospective 5-year dual energy radiographic absorptiometry study of 15 patients. Acta Orthop Scand 74:31–36PubMedCrossRef Venesmaa PK, Kroger HP, Jurvelin JS (2003) Periprosthetic bone loss after cemented total hip arthroplasty: a prospective 5-year dual energy radiographic absorptiometry study of 15 patients. Acta Orthop Scand 74:31–36PubMedCrossRef
27.
go back to reference Venesmaa PK, Kroger HP, Miettinen HJ (2001) Alendronate reduces periprosthetic bone loss after uncemented primary total hip arthroplasty: a prospective randomized study. J Bone Miner Res 16:2126–2131CrossRefPubMed Venesmaa PK, Kroger HP, Miettinen HJ (2001) Alendronate reduces periprosthetic bone loss after uncemented primary total hip arthroplasty: a prospective randomized study. J Bone Miner Res 16:2126–2131CrossRefPubMed
28.
go back to reference Wilkinson JM, Hamer AJ, Rogers A (2003) Bone mineral density and biochemical markers of bone turnover in aseptic loosening after total hip arthroplasty. J Orthop Res 21:691–696CrossRefPubMed Wilkinson JM, Hamer AJ, Rogers A (2003) Bone mineral density and biochemical markers of bone turnover in aseptic loosening after total hip arthroplasty. J Orthop Res 21:691–696CrossRefPubMed
29.
go back to reference Wilkinson JM, Stockley I, Peel NF et al (2001) Effect of pamidronate in preventing local bone loss after total hip arthroplasty: a randomized, double-blind, controlled trial. J Bone Miner Res 16:556–564CrossRefPubMed Wilkinson JM, Stockley I, Peel NF et al (2001) Effect of pamidronate in preventing local bone loss after total hip arthroplasty: a randomized, double-blind, controlled trial. J Bone Miner Res 16:556–564CrossRefPubMed
30.
go back to reference Wittenberg RH, Shea M, Swartz DE (1991) Importance of bone mineral density in instrumented spine fusions. Spine 16:647–652PubMedCrossRef Wittenberg RH, Shea M, Swartz DE (1991) Importance of bone mineral density in instrumented spine fusions. Spine 16:647–652PubMedCrossRef
31.
go back to reference Yaffe A, Iztkovich M, Earon Y (1997) Local delivery of an amino bisphosphonate prevents the resorptive phase of alveolar bone following mucoperiosteal flap surgery in rats. J Periodontol 68:884–889PubMed Yaffe A, Iztkovich M, Earon Y (1997) Local delivery of an amino bisphosphonate prevents the resorptive phase of alveolar bone following mucoperiosteal flap surgery in rats. J Periodontol 68:884–889PubMed
32.
go back to reference Zindrick MR, Wiltse LL, Widell EH et al (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop 99–112 Zindrick MR, Wiltse LL, Widell EH et al (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop 99–112
Metadata
Title
Alendronate treatment improves bone–pedicle screw interface fixation in posterior lateral spine fusion: An experimental study in a porcine model
Authors
Qingyun Xue
Haisheng Li
Xuenong Zou
Michel Dalstra
Martin Lind
Finn B. Christensen
Cody Bünger
Publication date
01-03-2010
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 3/2010
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-009-0759-4

Other articles of this Issue 3/2010

International Orthopaedics 3/2010 Go to the issue