Skip to main content
Top
Published in: International Orthopaedics 3/2009

01-06-2009 | Original Paper

Long-term results of the Wagner conical screw cup

Authors: Alexander Schuh, Annemarie Schraml, Gerd Hohenberger

Published in: International Orthopaedics | Issue 3/2009

Login to get access

Abstract

Thanks to its high primary stability, the concept of threaded cups has gained wide acceptance. The aim of this study is to report the long-term results of the Wagner conical screw cup. Between January 1993 and December 1994, 212 conical screw cup were implanted; 118 implants were clinically and radiographically followed up after a mean of 12.1 years. The Merle d’Aubigné score improved from a preoperative mean of 8.8 to 16.6 postoperatively. Four revisions were performed for heterotopic ossification. Three revisions were done to treat deep infection. Two isolated cup revisions and three more complete total hip joint revisions were required due to aseptic loosening. The overall survival rate at 12 years in this study was 93.2% (110/118); for aseptic loosening alone it was 95.8% (113/118). The Wagner conical screw cup by yields very good long-term results.
Literature
1.
go back to reference Aldinger PR, Thomsen M, Lukoschek M, Mau H, Ewerbeck V, Breusch SJ (2004) Long-term fate of cementless, threaded acetabular components with smooth surface treatment: minimum 10-year follow-up of two different designs. Arch Orthop Trauma Surg 124:469–475PubMedCrossRef Aldinger PR, Thomsen M, Lukoschek M, Mau H, Ewerbeck V, Breusch SJ (2004) Long-term fate of cementless, threaded acetabular components with smooth surface treatment: minimum 10-year follow-up of two different designs. Arch Orthop Trauma Surg 124:469–475PubMedCrossRef
2.
go back to reference Effenberger H, Imhof M, Witzel U (2001) Thread design of screw-in acetabulum prostheses (in German). Z Orthop Ihre Grenzgeb 139:428–434PubMedCrossRef Effenberger H, Imhof M, Witzel U (2001) Thread design of screw-in acetabulum prostheses (in German). Z Orthop Ihre Grenzgeb 139:428–434PubMedCrossRef
3.
go back to reference Effenberger H, Imhof M, Witzel U (2003) Criteria for success with threaded cups (design, material and modularity). Acta Chir Orthop Traumatol Cech 70:285–291PubMed Effenberger H, Imhof M, Witzel U (2003) Criteria for success with threaded cups (design, material and modularity). Acta Chir Orthop Traumatol Cech 70:285–291PubMed
4.
go back to reference Epinette JA, Manley MT, D, Antonio JA, Edidin AA, Capello WN (2003) A 10-year minimum follow-up of hydroxyapatite-coated threaded cups: clinical, radiographic and survivorship analyses with comparison to the literature. J Arthroplasty 18:140–148PubMedCrossRef Epinette JA, Manley MT, D, Antonio JA, Edidin AA, Capello WN (2003) A 10-year minimum follow-up of hydroxyapatite-coated threaded cups: clinical, radiographic and survivorship analyses with comparison to the literature. J Arthroplasty 18:140–148PubMedCrossRef
5.
go back to reference Fernández-González J, Canosa Sevillano R, García-Araujo C (1997) Cementless total hip arthroplasty with a threaded acetabular cup. Int Orthop 21:327–331PubMedCrossRef Fernández-González J, Canosa Sevillano R, García-Araujo C (1997) Cementless total hip arthroplasty with a threaded acetabular cup. Int Orthop 21:327–331PubMedCrossRef
6.
go back to reference Fink B, Protzen M, Hansen-Algenstaedt N, Berger J, Ruther W (2004) High migration rate of two types of threaded acetabular cups. Arch Orthop Trauma Surg 124:17–25PubMedCrossRef Fink B, Protzen M, Hansen-Algenstaedt N, Berger J, Ruther W (2004) High migration rate of two types of threaded acetabular cups. Arch Orthop Trauma Surg 124:17–25PubMedCrossRef
7.
go back to reference Grant P, Nordsletten L (2004) Total hip arthroplasty with the Lord prosthesis. A long-term follow-up study. J Bone Joint Surg Am 86-A:2636–2641PubMed Grant P, Nordsletten L (2004) Total hip arthroplasty with the Lord prosthesis. A long-term follow-up study. J Bone Joint Surg Am 86-A:2636–2641PubMed
8.
go back to reference Grübl A, Chiari C, Giurea A, Gruber M, Kaider A, Marker M, Zehetgruber H, Gottsauner-Wolf F (2006) Cementless total hip arthroplasty with the rectangular titanium Zweymuller stem. A concise follow-up, at a minimum of fifteen years, of a previous report. J Bone Joint Surg Am 88:2210–2215PubMedCrossRef Grübl A, Chiari C, Giurea A, Gruber M, Kaider A, Marker M, Zehetgruber H, Gottsauner-Wolf F (2006) Cementless total hip arthroplasty with the rectangular titanium Zweymuller stem. A concise follow-up, at a minimum of fifteen years, of a previous report. J Bone Joint Surg Am 88:2210–2215PubMedCrossRef
9.
go back to reference Havelin LI, Espehaug B, Engesaeter LB (2002) The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups. From the Norwegian Arthroplasty Register. J Bone Joint Surg Br 84:839–845PubMedCrossRef Havelin LI, Espehaug B, Engesaeter LB (2002) The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups. From the Norwegian Arthroplasty Register. J Bone Joint Surg Br 84:839–845PubMedCrossRef
10.
go back to reference Hendrich C, Ak D, Sauer U, Kirschner S, Rader CP (2004) Long-term results of cementless Parhofer-Mönch screw rings (in German). Z Orthop Ihre Grenzgeb 142:292–297PubMedCrossRef Hendrich C, Ak D, Sauer U, Kirschner S, Rader CP (2004) Long-term results of cementless Parhofer-Mönch screw rings (in German). Z Orthop Ihre Grenzgeb 142:292–297PubMedCrossRef
11.
go back to reference Hernandez-Vaquero D, Suarez-Vazquez A, Fernandez-Corona C, Menendez-Vinuela G, Alegre-Mateo R, Garcia-Sandoval MA (1996) Loosening of threaded acetabular cups in arthroplasty of the hip. The association with different types of coxarthrosis. Int Orthop 20:70–74PubMedCrossRef Hernandez-Vaquero D, Suarez-Vazquez A, Fernandez-Corona C, Menendez-Vinuela G, Alegre-Mateo R, Garcia-Sandoval MA (1996) Loosening of threaded acetabular cups in arthroplasty of the hip. The association with different types of coxarthrosis. Int Orthop 20:70–74PubMedCrossRef
12.
go back to reference Milosev I, Trebse R, Kovac S, Cor A, Pisot V (2006) Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of seven years. J Bone Joint Surg Am 88:1173–1182PubMedCrossRef Milosev I, Trebse R, Kovac S, Cor A, Pisot V (2006) Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of seven years. J Bone Joint Surg Am 88:1173–1182PubMedCrossRef
13.
go back to reference Nieuwenhuis JJ, Malefijt Jde W, Hendriks JC, Gosens T, Bonnet M (2005) Unsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis. Acta Orthop Belg 71:294–302PubMed Nieuwenhuis JJ, Malefijt Jde W, Hendriks JC, Gosens T, Bonnet M (2005) Unsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis. Acta Orthop Belg 71:294–302PubMed
14.
go back to reference Pazdirek P, Bartonicek J, Dzupa V (2001) The uncemented self-threading Ultima cup: first 5 years’ experience (in Czech). Acta Chir Orthop Traumatol Cech 68:24–30PubMed Pazdirek P, Bartonicek J, Dzupa V (2001) The uncemented self-threading Ultima cup: first 5 years’ experience (in Czech). Acta Chir Orthop Traumatol Cech 68:24–30PubMed
15.
go back to reference Pellengahr C, Wegener B, Anetzberger H, Maier M, Muller PE, Durr HR, Schulz C, Troullier H, Kuhne L, Refior HJ (2004) Medium to long-term results with the cementless threaded Acetabular Munich II type cup. Acta Chir Belg 104:413–417PubMed Pellengahr C, Wegener B, Anetzberger H, Maier M, Muller PE, Durr HR, Schulz C, Troullier H, Kuhne L, Refior HJ (2004) Medium to long-term results with the cementless threaded Acetabular Munich II type cup. Acta Chir Belg 104:413–417PubMed
16.
go back to reference Reikeras O, Gunderson RB (2006) Long-term results of HA coated threaded versus HA coated hemispheric press fit cups: 287 hips followed for 11 to 16 years. Arch Orthop Trauma Surg 126:503–508PubMedCrossRef Reikeras O, Gunderson RB (2006) Long-term results of HA coated threaded versus HA coated hemispheric press fit cups: 287 hips followed for 11 to 16 years. Arch Orthop Trauma Surg 126:503–508PubMedCrossRef
17.
go back to reference Robertson A, Lavalette D, Morgan S, Angus PD (2005) The hydroxyapatite-coated JRI-furlong hip. Outcome in patients under the age of 55 years. J Bone Joint Surg Br 87:12–15PubMed Robertson A, Lavalette D, Morgan S, Angus PD (2005) The hydroxyapatite-coated JRI-furlong hip. Outcome in patients under the age of 55 years. J Bone Joint Surg Br 87:12–15PubMed
18.
go back to reference Volkmann R, Schneider MA, Bretschneider C, Weise K (1999) More failures of cementless acetabular screw-rings than of cemented polyethylene cups in total hip arthroplasties. Int Orthop 23:138–139PubMedCrossRef Volkmann R, Schneider MA, Bretschneider C, Weise K (1999) More failures of cementless acetabular screw-rings than of cemented polyethylene cups in total hip arthroplasties. Int Orthop 23:138–139PubMedCrossRef
19.
go back to reference von Schulze Pellengahr C, Dull T, Muller PE, Durr HR, Baur-Melnyk A, Maier M, Birkenmaier C, Jansson V (2007) Long-term results of 58 hip cup revision arthroplasties using a threaded ring implant. Arch Orthop Trauma Surg 127:71–74CrossRef von Schulze Pellengahr C, Dull T, Muller PE, Durr HR, Baur-Melnyk A, Maier M, Birkenmaier C, Jansson V (2007) Long-term results of 58 hip cup revision arthroplasties using a threaded ring implant. Arch Orthop Trauma Surg 127:71–74CrossRef
Metadata
Title
Long-term results of the Wagner conical screw cup
Authors
Alexander Schuh
Annemarie Schraml
Gerd Hohenberger
Publication date
01-06-2009
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 3/2009
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-008-0569-0

Other articles of this Issue 3/2009

International Orthopaedics 3/2009 Go to the issue