Skip to main content
Top
Published in: International Orthopaedics 1/2007

01-08-2007 | Review

Enhanced acetabular component positioning through computer-assisted navigation

Authors: Thomas Ybinger, Wolfgang Kumpan

Published in: International Orthopaedics | Special Issue 1/2007

Login to get access

Abstract

Optimal positioning of the acetabular component improves the long-term success of total hip arthroplasty by reducing the rate of adverse outcomes, such as component wear and dislocation. Mechanical guides designed to facilitate proper component orientation are inadequate, as they do not account for variations in patient position and pelvic motion during surgery. Pioneering image-guided surgical navigation systems were developed to provide surgeons with improved methods for intraoperatively measuring orientation and alignment. Although enhanced orientation has been reported with such systems, they require preoperative CT scans and are therefore limited by the need for preplanning, the necessitiy of matching CT data with the actual patient position, and the additional costs associated with CT. The recent development of CT-free navigational tools addresses these disadvantages and offers real-time surgical feedback regarding the actual position of the acetabular component and instruments relative to the pelvis. Proper training and enhanced identification of bony landmarks will improve upon the success of these systems.
Literature
1.
go back to reference Ali Khan MA, Brakenbury PH, Reynolds IS (1981) Dislocation following total hip replacement. J Bone Joint Surg Br 63-B:214–218PubMed Ali Khan MA, Brakenbury PH, Reynolds IS (1981) Dislocation following total hip replacement. J Bone Joint Surg Br 63-B:214–218PubMed
2.
go back to reference Digioia AM 3rd, Jaramaz B, Plakseychuk AY, Moody JE Jr, Nikou C, Labarca RS, Levison TJ, Picard F (2002) Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty 17:359–364PubMedCrossRef Digioia AM 3rd, Jaramaz B, Plakseychuk AY, Moody JE Jr, Nikou C, Labarca RS, Levison TJ, Picard F (2002) Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty 17:359–364PubMedCrossRef
3.
go back to reference DiGioia AM, Simon DA, Jaramaz B, Blackwell M, Morgan FM, Colgan RD (1998) Intraoperative measurement of pelvic and acetabular component alignment using an image guided navigational tool. Trans Orthop Res Soc 23:198 DiGioia AM, Simon DA, Jaramaz B, Blackwell M, Morgan FM, Colgan RD (1998) Intraoperative measurement of pelvic and acetabular component alignment using an image guided navigational tool. Trans Orthop Res Soc 23:198
4.
go back to reference Dorr LD, Hishiki Y, Wan Z, Newton D, Yun A (2005) Development of imageless computer navigation for acetabular component position in total hip replacement. Iowa Orthop J 25:1–9PubMed Dorr LD, Hishiki Y, Wan Z, Newton D, Yun A (2005) Development of imageless computer navigation for acetabular component position in total hip replacement. Iowa Orthop J 25:1–9PubMed
5.
go back to reference Hassan DM, Johnston GH, Dust WN, Watson G, Dolovich AT (1998) Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty 13:80–84PubMedCrossRef Hassan DM, Johnston GH, Dust WN, Watson G, Dolovich AT (1998) Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty 13:80–84PubMedCrossRef
6.
go back to reference Hassan DM, Johnston GH, Dust WN, Watson LG, Cassidy D (1995) Radiographic calculation of anteversion in acetabular prostheses. J Arthroplasty 10:369–372PubMedCrossRef Hassan DM, Johnston GH, Dust WN, Watson LG, Cassidy D (1995) Radiographic calculation of anteversion in acetabular prostheses. J Arthroplasty 10:369–372PubMedCrossRef
7.
go back to reference Jaramaz B, DiGioia AM 3rd, Blackwell M, Nikou C (1998) Computer assisted measurement of cup placement in total hip replacement. Clin Orthop Relat Res 354:70–81PubMedCrossRef Jaramaz B, DiGioia AM 3rd, Blackwell M, Nikou C (1998) Computer assisted measurement of cup placement in total hip replacement. Clin Orthop Relat Res 354:70–81PubMedCrossRef
8.
go back to reference Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ (1998) Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty 13:530–534PubMedCrossRef Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ (1998) Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty 13:530–534PubMedCrossRef
9.
go back to reference Kummer FJ, Shah S, Iyer S, DiCesare PE (1999) The effect of acetabular cup orientations on limiting hip rotation. J Arthroplasty 14:509–513PubMedCrossRef Kummer FJ, Shah S, Iyer S, DiCesare PE (1999) The effect of acetabular cup orientations on limiting hip rotation. J Arthroplasty 14:509–513PubMedCrossRef
10.
go back to reference Leenders T, Vandevelde D, Mahieu G, Nuyts R (2002) Reduction in variability of acetabular cup abduction using computer assisted surgery: a prospective and randomized study. Comput Aided Surg 7:99–106PubMed Leenders T, Vandevelde D, Mahieu G, Nuyts R (2002) Reduction in variability of acetabular cup abduction using computer assisted surgery: a prospective and randomized study. Comput Aided Surg 7:99–106PubMed
11.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60:217–220PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60:217–220PubMed
12.
go back to reference Mahoney CR, Pellicci PM (2003) Complications in primary total hip arthroplasty: avoidance and management of dislocations. Instr Course Lect 52:247–255PubMed Mahoney CR, Pellicci PM (2003) Complications in primary total hip arthroplasty: avoidance and management of dislocations. Instr Course Lect 52:247–255PubMed
13.
go back to reference McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop Relat Res 261:159–170PubMed McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop Relat Res 261:159–170PubMed
14.
go back to reference Wentzensen A, Zheng G, Vock B, Langlotz U, Korber J, Nolte LP, Grutzner PA (2003) Image-based hip navigation. Int Orthop 27(Suppl 1):S43–S46PubMed Wentzensen A, Zheng G, Vock B, Langlotz U, Korber J, Nolte LP, Grutzner PA (2003) Image-based hip navigation. Int Orthop 27(Suppl 1):S43–S46PubMed
15.
go back to reference Widmer KH (2004) A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty 19:387–390PubMedCrossRef Widmer KH (2004) A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty 19:387–390PubMedCrossRef
16.
go back to reference Ybinger T, Kumpan W, Hoffart HE, Muschalik B, Bullman W, Zweymüller K (2007) Accuracy of navigation-assisted acetabular component positioning studied by CT measurements: methods and results. J Arthroplast (in press) Ybinger T, Kumpan W, Hoffart HE, Muschalik B, Bullman W, Zweymüller K (2007) Accuracy of navigation-assisted acetabular component positioning studied by CT measurements: methods and results. J Arthroplast (in press)
17.
go back to reference Zheng G, Marx A, Langlotz U, Widmer KH, Buttaro M, Nolte LP (2002) A hybrid CT-free navigation system for total hip arthroplasty. Comput Aided Surg 7:129–145PubMedCrossRef Zheng G, Marx A, Langlotz U, Widmer KH, Buttaro M, Nolte LP (2002) A hybrid CT-free navigation system for total hip arthroplasty. Comput Aided Surg 7:129–145PubMedCrossRef
Metadata
Title
Enhanced acetabular component positioning through computer-assisted navigation
Authors
Thomas Ybinger
Wolfgang Kumpan
Publication date
01-08-2007
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue Special Issue 1/2007
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-007-0430-x

Other articles of this Special Issue 1/2007

International Orthopaedics 1/2007 Go to the issue