Skip to main content
Top
Published in: International Orthopaedics 5/2008

01-10-2008 | Original Paper

Anterior cervical locking plate-related complications; prevention and treatment recommendations

Authors: Xie Ning, Yuan Wen, Ye Xiao-Jian, Ni Bin, Chen De-Yu, Xiao Jian-Ru, Jia Lian-Shun

Published in: International Orthopaedics | Issue 5/2008

Login to get access

Abstract

A retrospective study evaluating complications in 2,233 consecutive patients of subaxial cervical disorders treated with an anterior cervical locking plate was performed, and recommendations for prevention and treatment were made. The average length of follow-up was 1.3 years. Any loosening or breaking of the plates and screws or malpositions that threatened tracheoesophageal or neurovascular structures were defined as the complications. There were 239 cases (10.7%) with different kinds of complications. The complications included oblique plating in 56 cases in which the screw could irritate the nerve root. Screws were driven into the disc space in four cases, which ultimately led to plate loosening. Screws penetrated the endplate or passed excessively close to it producing a triangle fracture in 19 cases. Loosening or breaking of the plate and the screw was found in 115 cases. These phenomena were always associated with non-union. Three oesophageal perforations occurred and conservative treatments proved effective. Finally, overlong plates impinged on the adjacent level in 14 cases and promoted disc degeneration ultimately leading to revision surgery. Good training and careful operation may help to decrease the complication rate. Most hardware complications are not symptomatic and can be treated conservatively. Only a few of them need immediate reoperation.
Literature
1.
go back to reference Aebi M, Mohler J, Zach GA et al (1986) Indication, surgical technique, and results of 100 surgically-treated fractures and fracture-dislocations of the cervical spine. Clin Orthop 203:244–257PubMed Aebi M, Mohler J, Zach GA et al (1986) Indication, surgical technique, and results of 100 surgically-treated fractures and fracture-dislocations of the cervical spine. Clin Orthop 203:244–257PubMed
2.
go back to reference Böhler J, Gaudernak T (1980) Anterior plate stabilization for fracture-dislocations of the lower cervical spine. J Trauma 20:203–205PubMedCrossRef Böhler J, Gaudernak T (1980) Anterior plate stabilization for fracture-dislocations of the lower cervical spine. J Trauma 20:203–205PubMedCrossRef
3.
go back to reference Brown JA, Havel P, Ebraheim N et al (1988) Cervical stabilization by plate and bone fusion. Spine 13:236–240PubMedCrossRef Brown JA, Havel P, Ebraheim N et al (1988) Cervical stabilization by plate and bone fusion. Spine 13:236–240PubMedCrossRef
4.
go back to reference Casha S, Fehlings MG (2003) Clinical and radiological evaluation of the Codman semiconstrained load-sharing anterior cervical plate: prospective multicenter trial and independent blinded evaluation of outcome. J Neurosurg 99 (3 Suppl):264–270PubMed Casha S, Fehlings MG (2003) Clinical and radiological evaluation of the Codman semiconstrained load-sharing anterior cervical plate: prospective multicenter trial and independent blinded evaluation of outcome. J Neurosurg 99 (3 Suppl):264–270PubMed
5.
go back to reference Caspar W, Barbier DD, Klara PM (1989) Anterior cervical fusion and Caspar plate stabilization for cervical trauma. Neurosurgery 25:491–502PubMedCrossRef Caspar W, Barbier DD, Klara PM (1989) Anterior cervical fusion and Caspar plate stabilization for cervical trauma. Neurosurgery 25:491–502PubMedCrossRef
7.
go back to reference Grubb MR, Currter BL, Shih JS (1998) Biomechenical evaluation of anterior cervical spine stabilization. Spine 23:886–892PubMedCrossRef Grubb MR, Currter BL, Shih JS (1998) Biomechenical evaluation of anterior cervical spine stabilization. Spine 23:886–892PubMedCrossRef
8.
go back to reference Hanci M, Toprak M, Sarioglu AC et al (1995) Oesophageal perforation subsequent to anterior cervical spine screw/plate fixation. Paraplegia 33:606–609PubMed Hanci M, Toprak M, Sarioglu AC et al (1995) Oesophageal perforation subsequent to anterior cervical spine screw/plate fixation. Paraplegia 33:606–609PubMed
9.
go back to reference Kostuik JP, Connolly PJ, Esses SI et al (1993) Anterior cervical plate fixation with the titanium hollow screw plate system. Spine 18:1273–1278PubMedCrossRef Kostuik JP, Connolly PJ, Esses SI et al (1993) Anterior cervical plate fixation with the titanium hollow screw plate system. Spine 18:1273–1278PubMedCrossRef
10.
go back to reference Lowery GL, McDonough RF (1998) The significance of hardware failure in anterior cervical plate fixation. Patients with 2- to 7-year follow-up. Spine 23:181–186; Discussion 186–187 Lowery GL, McDonough RF (1998) The significance of hardware failure in anterior cervical plate fixation. Patients with 2- to 7-year follow-up. Spine 23:181–186; Discussion 186–187
11.
go back to reference Orlando ER, Caroli E, Ferrante L (2003) Management of the cervical esophagus and hypofarinx perforations complicating anterior cervical spine surgery. Spine 28:E290–E295PubMedCrossRef Orlando ER, Caroli E, Ferrante L (2003) Management of the cervical esophagus and hypofarinx perforations complicating anterior cervical spine surgery. Spine 28:E290–E295PubMedCrossRef
12.
go back to reference Paramore CG, Dickman CA, Sonntag VK (1996) Radiographic and clinical follow-up review of Caspar plates in 49 patients. J Neurosurg 84:957–961PubMedCrossRef Paramore CG, Dickman CA, Sonntag VK (1996) Radiographic and clinical follow-up review of Caspar plates in 49 patients. J Neurosurg 84:957–961PubMedCrossRef
13.
go back to reference Pompili A, Canitano S, Caroli F et al (2002) Asymptomatic esophageal perforation caused by late screw migration after anterior cervical plating: report of a case and review of relevant literature. Spine 27:E499–E502PubMedCrossRef Pompili A, Canitano S, Caroli F et al (2002) Asymptomatic esophageal perforation caused by late screw migration after anterior cervical plating: report of a case and review of relevant literature. Spine 27:E499–E502PubMedCrossRef
14.
go back to reference Rechtine GR, Cahill DW, Gruenberg M et al (1994) The synthes cervical spine locking plate and screw system in anterior cervical fusion. Tech Orthop 9:86–91CrossRef Rechtine GR, Cahill DW, Gruenberg M et al (1994) The synthes cervical spine locking plate and screw system in anterior cervical fusion. Tech Orthop 9:86–91CrossRef
15.
go back to reference Ripa DR, Kowall MG, Meyer PR et al (1991) Series of ninety-two traumatic cervical spine injuries stabilized with anterior ASIF plate fusion technique. Spine (16 Suppl):S46-S55 Ripa DR, Kowall MG, Meyer PR et al (1991) Series of ninety-two traumatic cervical spine injuries stabilized with anterior ASIF plate fusion technique. Spine (16 Suppl):S46-S55
16.
go back to reference Sasso RC, Ruggiero RA Jr, Reilly TM et al (2003) Early reconstruction failures after multilevel cervical corpectomy. Spine 28:140-142PubMedCrossRef Sasso RC, Ruggiero RA Jr, Reilly TM et al (2003) Early reconstruction failures after multilevel cervical corpectomy. Spine 28:140-142PubMedCrossRef
17.
go back to reference Tominaga T, Koshu K, MIzoi K et al (1994) Anterior cervical fixation with the titanium locking screw plate: a preliminary report. Surg Neurol 42:408-413PubMedCrossRef Tominaga T, Koshu K, MIzoi K et al (1994) Anterior cervical fixation with the titanium locking screw plate: a preliminary report. Surg Neurol 42:408-413PubMedCrossRef
18.
go back to reference Vaccaro AR, Abraham D, Cotle J et al (1995) Failure of multilevel anterior unicortical cervical plate instrumentation. Presented at the Cervical Spine Research Society, Santa Fe, New Mexico, November 30 Vaccaro AR, Abraham D, Cotle J et al (1995) Failure of multilevel anterior unicortical cervical plate instrumentation. Presented at the Cervical Spine Research Society, Santa Fe, New Mexico, November 30
19.
go back to reference Yee GKH, Terry AF (1993) Esophageal perforation by an anterior cervical fixation device. Spine 18:522-527PubMedCrossRef Yee GKH, Terry AF (1993) Esophageal perforation by an anterior cervical fixation device. Spine 18:522-527PubMedCrossRef
20.
go back to reference Yen CP, Hwang TY, Wang CJ et al (2005) Fracture of anterior cervical plate implant–report of two cases. Acta Neurochir (Wien) 147:665-667; discussion 667CrossRef Yen CP, Hwang TY, Wang CJ et al (2005) Fracture of anterior cervical plate implant–report of two cases. Acta Neurochir (Wien) 147:665-667; discussion 667CrossRef
21.
go back to reference Yue WM, Brodner W, Highland TR (2005) Long-term results after anterior cervical discectomy and fusion with allograft and plating: a 5- to 11-year radiologic and clinical follow-up study. Spine 30:2138–2144PubMedCrossRef Yue WM, Brodner W, Highland TR (2005) Long-term results after anterior cervical discectomy and fusion with allograft and plating: a 5- to 11-year radiologic and clinical follow-up study. Spine 30:2138–2144PubMedCrossRef
Metadata
Title
Anterior cervical locking plate-related complications; prevention and treatment recommendations
Authors
Xie Ning
Yuan Wen
Ye Xiao-Jian
Ni Bin
Chen De-Yu
Xiao Jian-Ru
Jia Lian-Shun
Publication date
01-10-2008
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 5/2008
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-007-0369-y

Other articles of this Issue 5/2008

International Orthopaedics 5/2008 Go to the issue