Skip to main content
Top
Published in: International Orthopaedics 2/2008

01-04-2008 | Original Paper

Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem

Authors: H. Wangen, P. Lereim, I. Holm, R. Gunderson, O. Reikerås

Published in: International Orthopaedics | Issue 2/2008

Login to get access

Abstract

It is well accepted that youth and high activity levels are among the factors that increase the risk of mechanical failure of total hip prostheses. However, there are few reports of long-term results in very young patients. In this study, we evaluated the results of total 49 hip replacements (THRs) using an uncemented total hip prosthesis in 44 patients (28 females) who were 30 years or younger (range: 15–30 years). The diagnosis was ostearthritis due to congenital dislocations in 28 patients, with the remaining patients having diagnoses of sequelae of fracture, infection, Calve-Legg-Perthes disease, avascular necrosis, chondrodystrophia and epiphyseal dysplasia. In all cases we used an uncemented straight stem fully coated with hydroxyapatite (HA). In 36 cases we used a hemispherical cup inserted with press fit, and in seven cases we used a hemispherical screw cup. The patients were evaluated ten to 16 years (mean: 13 years) after the operation by radiographic and clinical examinations, including the Harris Hip, WOMAC and EuroQol-5D scores. In a sub-group of nine patients with a unilateral prosthesis, the muscle strength of the quadriceps and hamstrings was tested using a Cybex 6000. None of the stems were revised at the follow-up examination, and all were classified as well integrated, with no signs of radiological loosening. Twenty-four hips had revision of the acetabular component due to mechanical failure. The Harris Hip score was, on average, 88 (range: 62–100), the WOMAC score 80 (range: 37–100) and the EuroQol score 0.68 (range: −0.14–1). Isokinetic muscle strength testing showed that seven of the nine tested patients were weaker on the operated side. In conclusion, we found mechanical failures at the acetabular side, but excellent results with a fully HA-coated femoral stem, with no revisions after ten to 16 years.
Literature
1.
go back to reference Amstutz HC, Nasser S, More RC, Kabo JM (1989) The anthropometric total hip femoral prosthesis. Preliminary clinical and roentgenographic findings of exact-fit cementless application. Clin Orthop 242:104–119PubMed Amstutz HC, Nasser S, More RC, Kabo JM (1989) The anthropometric total hip femoral prosthesis. Preliminary clinical and roentgenographic findings of exact-fit cementless application. Clin Orthop 242:104–119PubMed
2.
go back to reference Bellamy N, Campbell J, Stevens J, Pilch L, Stewart C, Mahmood Z (1997) Validation study of a computerized version of the Western Ontario and McMaster Universities VA3.0 Osteoarthritis index. J Rheumatol 24:2413–2415PubMed Bellamy N, Campbell J, Stevens J, Pilch L, Stewart C, Mahmood Z (1997) Validation study of a computerized version of the Western Ontario and McMaster Universities VA3.0 Osteoarthritis index. J Rheumatol 24:2413–2415PubMed
3.
go back to reference Capello WN, D’Antonio JA, Feinberg JR, Manley MT (2003) Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old. A concise follow-up of a previous report. J Bone Joint Surg Am 85:885–889PubMed Capello WN, D’Antonio JA, Feinberg JR, Manley MT (2003) Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old. A concise follow-up of a previous report. J Bone Joint Surg Am 85:885–889PubMed
4.
go back to reference D’Antonio JA, Capello WN, Manley MT, Feinberg J (1997) Hydroxyapatite coated implants: total hip arthroplasty in the young patient and patients with avascular necrosis. Clin Orthop 344:124–138PubMed D’Antonio JA, Capello WN, Manley MT, Feinberg J (1997) Hydroxyapatite coated implants: total hip arthroplasty in the young patient and patients with avascular necrosis. Clin Orthop 344:124–138PubMed
5.
go back to reference Dorr LD, Kane TJ 3rd, Conaty JP (1994) Long-term results of cemented total hip arthroplasty in patients 45 years old or younger. A 16-year follow-up study. J Arthroplasty 19:453–456CrossRef Dorr LD, Kane TJ 3rd, Conaty JP (1994) Long-term results of cemented total hip arthroplasty in patients 45 years old or younger. A 16-year follow-up study. J Arthroplasty 19:453–456CrossRef
6.
go back to reference Dudkiewicz I, Salai M, Ganel A, Blankstein A, Chechik A (2002) Total hip arthroplasty in patients younger than 30 years of age following developmental dysplasia of hip in infancy. Arch Orthop Trauma Surg 122:134–142CrossRef Dudkiewicz I, Salai M, Ganel A, Blankstein A, Chechik A (2002) Total hip arthroplasty in patients younger than 30 years of age following developmental dysplasia of hip in infancy. Arch Orthop Trauma Surg 122:134–142CrossRef
7.
go back to reference Emery DF, Clarke HJ, Grover ML (1997) Stanmore total hip replacement in younger patients: review of a group of patients under 50 years of age at operation. J Bone Joint Surg [Br] 79:240–246 Emery DF, Clarke HJ, Grover ML (1997) Stanmore total hip replacement in younger patients: review of a group of patients under 50 years of age at operation. J Bone Joint Surg [Br] 79:240–246
8.
go back to reference Engh CA, Bobyn JD, Glassman AH (1987) Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg [Br] 69:45–55 Engh CA, Bobyn JD, Glassman AH (1987) Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg [Br] 69:45–55
9.
go back to reference Giannikas KA, Din R, Sadiq S, Dunningham TH (2002) Medium-term results of the ABG total hip arthroplasty in young patients. J Arthroplasty 17:184–188PubMedCrossRef Giannikas KA, Din R, Sadiq S, Dunningham TH (2002) Medium-term results of the ABG total hip arthroplasty in young patients. J Arthroplasty 17:184–188PubMedCrossRef
10.
go back to reference Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17–27PubMed
11.
go back to reference Holm I, Nordsletten L, Steen H, Folleras G, Bjerkreim I (1994) Muscel function after mid-shaft femoral shortening. A prospective study with a two year follow-up. J Bone Joint Surg [Br] 76:143–146 Holm I, Nordsletten L, Steen H, Folleras G, Bjerkreim I (1994) Muscel function after mid-shaft femoral shortening. A prospective study with a two year follow-up. J Bone Joint Surg [Br] 76:143–146
12.
go back to reference Kawamura H, Dunbar MJ, Murray P, Bourne RB, Rorabeck CH (2001) The porous coated anatomic total hip replacement. A ten to fourteen-year follow-up study of a cementless total hip arthroplasty. J Bone Joint Surg [Am] 83:1333–1338 Kawamura H, Dunbar MJ, Murray P, Bourne RB, Rorabeck CH (2001) The porous coated anatomic total hip replacement. A ten to fourteen-year follow-up study of a cementless total hip arthroplasty. J Bone Joint Surg [Am] 83:1333–1338
13.
go back to reference Kilgus DJ, Shimaoka EE, Tipton JS, Eberle RW (1993) Dual-enrgy X-ray absorbtiometry measurement of bone mineral density around porous-coated cementless femoral implants. Methods and preliminary results. J Bone Joint Surg Br 75:279–287PubMed Kilgus DJ, Shimaoka EE, Tipton JS, Eberle RW (1993) Dual-enrgy X-ray absorbtiometry measurement of bone mineral density around porous-coated cementless femoral implants. Methods and preliminary results. J Bone Joint Surg Br 75:279–287PubMed
14.
go back to reference Kind P, Dolan P, Gudex C, Williams A (1988) Variation in population health status: results from a United Kingdom national questionnaire survey. Br Med 316:734–741 Kind P, Dolan P, Gudex C, Williams A (1988) Variation in population health status: results from a United Kingdom national questionnaire survey. Br Med 316:734–741
15.
go back to reference Loupasis G, Hyde ID, Morris EW (1998) The furlong hydroxyapatite coated femoral prosthesis: a 4 to 7 year follow up study. Arch Orthop Traum Surg 117:132–135CrossRef Loupasis G, Hyde ID, Morris EW (1998) The furlong hydroxyapatite coated femoral prosthesis: a 4 to 7 year follow up study. Arch Orthop Traum Surg 117:132–135CrossRef
16.
go back to reference Malchau H, Karrholm J, Wang YX, Herberts P (1995) Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiosterometry in 51 patients. Acta Orthop Scand 66:418–424PubMedCrossRef Malchau H, Karrholm J, Wang YX, Herberts P (1995) Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiosterometry in 51 patients. Acta Orthop Scand 66:418–424PubMedCrossRef
17.
go back to reference Malchau P, Herberts P, Soderman P, Oden A (2000) Update and validation of results from the Swedish Hip Arthroplasty Registry 1979–1998. In: Proc 67th Annu Meet Am Acad Orthop Surg. Orlando, Florida Malchau P, Herberts P, Soderman P, Oden A (2000) Update and validation of results from the Swedish Hip Arthroplasty Registry 1979–1998. In: Proc 67th Annu Meet Am Acad Orthop Surg. Orlando, Florida
18.
go back to reference Nilsdotter A-K, Peterson IF, Roos EM, Lohmander LS (2003) Predictors of patient relevant outcome after total hip replacement for osteoarthritis: a prospective study. Ann Rheum Dis 62:923–930PubMedCrossRef Nilsdotter A-K, Peterson IF, Roos EM, Lohmander LS (2003) Predictors of patient relevant outcome after total hip replacement for osteoarthritis: a prospective study. Ann Rheum Dis 62:923–930PubMedCrossRef
19.
go back to reference Overgaard S, Soballe K, Lind M, Bunger C (1997) Resorption of hydroxyapatite and fluorapatite coatings in man. An experimental study in trabecular bone. J Bone Joint Surg [Br] 79:654–659CrossRef Overgaard S, Soballe K, Lind M, Bunger C (1997) Resorption of hydroxyapatite and fluorapatite coatings in man. An experimental study in trabecular bone. J Bone Joint Surg [Br] 79:654–659CrossRef
20.
go back to reference Reikeras O, Gunderson RB (2002) Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7–10 years. Acta Orthop Scand 73:104–108PubMedCrossRef Reikeras O, Gunderson RB (2002) Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7–10 years. Acta Orthop Scand 73:104–108PubMedCrossRef
21.
go back to reference Reikeras O, Gunderson RB (2003) Excellent results of HA coating on a grit-blasted stem: 245 patients followed for 8–12 years. Acta Orthop Scand 74:140–145PubMedCrossRef Reikeras O, Gunderson RB (2003) Excellent results of HA coating on a grit-blasted stem: 245 patients followed for 8–12 years. Acta Orthop Scand 74:140–145PubMedCrossRef
22.
go back to reference Wroblewski BM, Siney PD, Fleming PA (2002) Charnley low-frictional torque arthroplasty in patients under the age of 51 years. Follow-up to 33 years. J Bone Joint Surg [Br] 84:540–543CrossRef Wroblewski BM, Siney PD, Fleming PA (2002) Charnley low-frictional torque arthroplasty in patients under the age of 51 years. Follow-up to 33 years. J Bone Joint Surg [Br] 84:540–543CrossRef
23.
go back to reference Zicat B, Engh CA, Gokcen E (1995) Pattern of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg [Am] 77:432–539 Zicat B, Engh CA, Gokcen E (1995) Pattern of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg [Am] 77:432–539
Metadata
Title
Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem
Authors
H. Wangen
P. Lereim
I. Holm
R. Gunderson
O. Reikerås
Publication date
01-04-2008
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 2/2008
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0309-2

Other articles of this Issue 2/2008

International Orthopaedics 2/2008 Go to the issue