Cervical disc prosthesis replacement and interbody fusion — a comparative study

Authors: Sun Peng-Fei, Jia Yu–Hua

Published in: International Orthopaedics | Issue 1/2008

Login to get access

Abstract

The purpose of this paper is to compare the new functional intervertebral cervical disc prosthesis replacement and the classical interbody fusion operation, including the clinical effect and maintenance of the stability and segmental motion of cervical vertebrae. Twenty-four patients with single C5-6 intervertebral disk hernias were specifically selected and divided randomly into two groups: One group underwent artificial cervical disc replacement and the other group received interbody fusion. All patients were followed up and evaluated. The operation time for the single disc replacement was (130 ± 50) minutes and interbody fusion was (105 ± 53) minutes. Neurological or vascular complications were not observed during or after operation. There was no prosthesis subsidence or extrusion. The JOA score of the group with prosthesis replacement increased from an average of 8.6 to 15.8. The JOA score of the group with interbody fusion increased from an average of 9 to 16.2. The clinical effect and the ROM of the adjacent space of the two groups showed no statistical difference. The short follow-up time does not support the advantage of the cervical disc prosthesis. The clinical effect and the maintenance of the function of the motion of the intervertebral space are no better than the interbody fusion. At least 5 years of follow-up is needed to assess the long-term functionality of the prosthesis and the influence on adjacent levels.
Literature
1.
go back to reference Anderson PA (2003) Wear analysis of the Bryan cervical disc prosthesis. Spine 28:186–194CrossRef Anderson PA (2003) Wear analysis of the Bryan cervical disc prosthesis. Spine 28:186–194CrossRef
2.
go back to reference Botelho RV (2003) Preliminary clinical experience with the Bryan cervical disc prosthesis. Neurosurgery 53:785–789PubMedCrossRef Botelho RV (2003) Preliminary clinical experience with the Bryan cervical disc prosthesis. Neurosurgery 53:785–789PubMedCrossRef
3.
go back to reference Bryan VE Jr (2002) Cervical motion segment replacement. Eur Spine J 11 (Suppl2):92–97 Bryan VE Jr (2002) Cervical motion segment replacement. Eur Spine J 11 (Suppl2):92–97
4.
go back to reference Goffin J, Casey A, Kehr P et al (2002) Preliminary clinical experience with the Bryan Cervical Disc Prosthesis. Neurosurgery 51:840–847PubMedCrossRef Goffin J, Casey A, Kehr P et al (2002) Preliminary clinical experience with the Bryan Cervical Disc Prosthesis. Neurosurgery 51:840–847PubMedCrossRef
5.
go back to reference Goffin J, Calenbergh FV, Loon JV (2003) Intermediate followup after treatment of degenerative disease with the Bryan cervical disc prosthesis: Single-level and bi-level. Spin 28:2673–2678CrossRef Goffin J, Calenbergh FV, Loon JV (2003) Intermediate followup after treatment of degenerative disease with the Bryan cervical disc prosthesis: Single-level and bi-level. Spin 28:2673–2678CrossRef
6.
go back to reference Mayer HM, Wiechert K, Korge A (2002) Minimal invasive total disc replacement: Surgical technique and preliminary clinical results. Eur Spine J 11:124–130 Mayer HM, Wiechert K, Korge A (2002) Minimal invasive total disc replacement: Surgical technique and preliminary clinical results. Eur Spine J 11:124–130
7.
go back to reference Pickett GE, Duggal N (2003) Artificial disc insertion following anterior cervical discectomy. Can J NeurolSc 30:278–281 Pickett GE, Duggal N (2003) Artificial disc insertion following anterior cervical discectomy. Can J NeurolSc 30:278–281
8.
go back to reference Sekhon LH (2003) Cervical arthroplasty in the management of spondylotic myelopathy. J Spinal Disord Tech 16:307–309PubMed Sekhon LH (2003) Cervical arthroplasty in the management of spondylotic myelopathy. J Spinal Disord Tech 16:307–309PubMed
Metadata
Title
Cervical disc prosthesis replacement and interbody fusion — a comparative study
Authors
Sun Peng-Fei
Jia Yu–Hua
Publication date
01-02-2008
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 1/2008
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0287-4

Other articles of this Issue 1/2008

International Orthopaedics 1/2008 Go to the issue