Skip to main content
Top
Published in: International Orthopaedics 6/2004

01-12-2004 | Original Paper

Clinical and radiological results of hydroxyapatite-coated acetabular cups

Authors: J. Blacha, J. Gągała

Published in: International Orthopaedics | Issue 6/2004

Login to get access

Abstract

We prospectively studied a consecutive series of 60 primary total hip arthroplasties in 52 patients. All patients had a hydroxyapatite-coated hemispherical acetabular cup (OCTOFIT). Mean patient age was 52.5 (34–73) years. In 38 hips, a 28-mm and in 22 hips a 32-mm diameter cobalt-chrome femoral head was used. We could follow 53 hips for a mean of 81 (28–125) months. Four cups were revised because of osteolysis, and in another six cups, slight osteolysis without migration was seen. The average annual linear wear rate was 0.05 mm (±0.05) for 28-mm heads and 0.16 mm (±0.09) for 32-mm heads (p<0.0001). Survivorship analysis predicted a survival rate of 86±6.7% at 10 years.
Literature
1.
go back to reference Barrack RL, Folgueras A, Munn B, Tvetden D, Sharkey P (1997) Pelvic lysis and polyethylene wear at 5–8 years in an uncemented total hip. Clin Orthop 335:211–217PubMed Barrack RL, Folgueras A, Munn B, Tvetden D, Sharkey P (1997) Pelvic lysis and polyethylene wear at 5–8 years in an uncemented total hip. Clin Orthop 335:211–217PubMed
2.
go back to reference Blacha J (2004) High osteolysis and revision ratio after total hip arthroplasty with hydroxyapatite coated ABG hip prostheses followed 5–9 years. Acta Orthop Scand (in press) Blacha J (2004) High osteolysis and revision ratio after total hip arthroplasty with hydroxyapatite coated ABG hip prostheses followed 5–9 years. Acta Orthop Scand (in press)
3.
go back to reference Brooker AF, Bowerman JW, Robinson RA, Riley LH (1973) Ectopic ossification following total hip arthroplasty: incidence and method of classification. J Bone Joint Surg Am 55:1629–1632PubMed Brooker AF, Bowerman JW, Robinson RA, Riley LH (1973) Ectopic ossification following total hip arthroplasty: incidence and method of classification. J Bone Joint Surg Am 55:1629–1632PubMed
4.
go back to reference Capello WN, D’Antonio JA, Manley MT, Feinberg JR (1998) Hydroxyapatite in total hip arthroplasty. Clin Orthop 355:200–211CrossRefPubMed Capello WN, D’Antonio JA, Manley MT, Feinberg JR (1998) Hydroxyapatite in total hip arthroplasty. Clin Orthop 355:200–211CrossRefPubMed
5.
go back to reference Chung YY, Kim HD, Kim KS (2002) Bone ingrowth on smooth-surfaced hydroxyapatite-coated acetabular cup. Int Orthop 26:283–286CrossRefPubMed Chung YY, Kim HD, Kim KS (2002) Bone ingrowth on smooth-surfaced hydroxyapatite-coated acetabular cup. Int Orthop 26:283–286CrossRefPubMed
6.
go back to reference Claus AM, Sychterz CJ, Hopper RH Jr, Engh CA (2001) Pattern of osteolysis around two different cementless metal-backed cups: retrospective, radiographic analysis at minimum 10 years follow-up. J Arthroplasty 16:177–182CrossRefPubMed Claus AM, Sychterz CJ, Hopper RH Jr, Engh CA (2001) Pattern of osteolysis around two different cementless metal-backed cups: retrospective, radiographic analysis at minimum 10 years follow-up. J Arthroplasty 16:177–182CrossRefPubMed
7.
go back to reference D’Antonio JA, Capello WN, Manley MT, Feinberg J (1997) Hydroxyapatite coated implants. Total hip arthroplasty in the young patients and patients with avascular necrosis. Clin Orthop 344:124–138PubMed D’Antonio JA, Capello WN, Manley MT, Feinberg J (1997) Hydroxyapatite coated implants. Total hip arthroplasty in the young patients and patients with avascular necrosis. Clin Orthop 344:124–138PubMed
8.
go back to reference DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20–32PubMed DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20–32PubMed
9.
go back to reference Dorr LD, Wan Z, Cohen J (1998) Hemispheric titanium porous coated acetabular component without screw fixation. Clin Orthop 351:158–168PubMed Dorr LD, Wan Z, Cohen J (1998) Hemispheric titanium porous coated acetabular component without screw fixation. Clin Orthop 351:158–168PubMed
10.
go back to reference Dunkley AB, Eldridge JDJ, Lee MB, Smith EJ, Learmonth ID (2000) Cementless acetabular replacement in the young. A 5 to 10 year prospective study. Clin Orthop 376:149–155CrossRefPubMed Dunkley AB, Eldridge JDJ, Lee MB, Smith EJ, Learmonth ID (2000) Cementless acetabular replacement in the young. A 5 to 10 year prospective study. Clin Orthop 376:149–155CrossRefPubMed
11.
go back to reference Giannikas KA, Din R, Sadiq S, Dunningham TH (2002) Medium-term result of the ABG total hip arthroplasty in young patients. J Arthroplasty 17:184–188CrossRefPubMed Giannikas KA, Din R, Sadiq S, Dunningham TH (2002) Medium-term result of the ABG total hip arthroplasty in young patients. J Arthroplasty 17:184–188CrossRefPubMed
12.
go back to reference Gruen TA, McNeice GM, Amstutz HC (1976) Modes of failure of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17–27 Gruen TA, McNeice GM, Amstutz HC (1976) Modes of failure of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17–27
13.
go back to reference Harris WH (1969) Traumatic arthritis of hip after dislocation and acetabular fractures. Treatment by mold arthroplasty. An end result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755PubMed Harris WH (1969) Traumatic arthritis of hip after dislocation and acetabular fractures. Treatment by mold arthroplasty. An end result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755PubMed
14.
go back to reference Kim YH, Oh SH, Kim JS (2003) Primary total hip arthroplasty with a second-generation cementless total hip prosthesis in patients younger than fifty years of age. J Bone Joint Surg Am 85:109–114CrossRef Kim YH, Oh SH, Kim JS (2003) Primary total hip arthroplasty with a second-generation cementless total hip prosthesis in patients younger than fifty years of age. J Bone Joint Surg Am 85:109–114CrossRef
15.
go back to reference Latimer HA, Lachiewicz PF (1996) Porous-coated acetabular components with screw fixation. J Bone Joint Surg Am 78:975–981PubMed Latimer HA, Lachiewicz PF (1996) Porous-coated acetabular components with screw fixation. J Bone Joint Surg Am 78:975–981PubMed
16.
go back to reference Livermore J, Ilstrup MS, Morrey B (1999) Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 72:518–528 Livermore J, Ilstrup MS, Morrey B (1999) Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 72:518–528
17.
go back to reference Manley MT, Capello WN, D’Antonio JA, Edidin AA, Geesink RG (1998) Fixation of acetabular cups without cement in total hip arthroplasty. A comparison of three different implant surfaces at a minimum duration of follow-up of five years. J Bone Joint Surg Am 80:1175–1185PubMed Manley MT, Capello WN, D’Antonio JA, Edidin AA, Geesink RG (1998) Fixation of acetabular cups without cement in total hip arthroplasty. A comparison of three different implant surfaces at a minimum duration of follow-up of five years. J Bone Joint Surg Am 80:1175–1185PubMed
18.
go back to reference Manley MT, D’Antonio JA, Capello WN, Edidin AA (2002) Osteolysis: a disease of access to fixation interfaces. Clin Orthop 405:129–137PubMed Manley MT, D’Antonio JA, Capello WN, Edidin AA (2002) Osteolysis: a disease of access to fixation interfaces. Clin Orthop 405:129–137PubMed
19.
go back to reference Morscher EW, Hefti A, Aebi U (1998) Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating. J Bone Joint Surg Br 80:267–272CrossRefPubMed Morscher EW, Hefti A, Aebi U (1998) Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating. J Bone Joint Surg Br 80:267–272CrossRefPubMed
20.
go back to reference Oosterbos CJM, Rahmy AIA, Tonino AJ (2001) Hydroxyapatite-coated hip prosthesis followed up for five years. Int Orthop 25:17–21CrossRefPubMed Oosterbos CJM, Rahmy AIA, Tonino AJ (2001) Hydroxyapatite-coated hip prosthesis followed up for five years. Int Orthop 25:17–21CrossRefPubMed
21.
go back to reference Rokkum M, Brandt M, Bye K, Hetland KR, Waage S, Reigstad A (1999) Polyethylene wear, osteolysis and acetabular loosening with an HA-coated hip prosthesis. A follow-up of 94 consecutive arthroplasties. J. Bone Joint Surg Br 81:582–589CrossRefPubMed Rokkum M, Brandt M, Bye K, Hetland KR, Waage S, Reigstad A (1999) Polyethylene wear, osteolysis and acetabular loosening with an HA-coated hip prosthesis. A follow-up of 94 consecutive arthroplasties. J. Bone Joint Surg Br 81:582–589CrossRefPubMed
22.
go back to reference Soballe K, Hansen ES, Brockstedt-Rasmussen H, Hjortdal VE, Juhl GI, Pedersen CM, Hvid I, Buenger C (1991) Gap healing enhanced by hydroxyapatite coating in dogs. Clin Orthop 272:300–307PubMed Soballe K, Hansen ES, Brockstedt-Rasmussen H, Hjortdal VE, Juhl GI, Pedersen CM, Hvid I, Buenger C (1991) Gap healing enhanced by hydroxyapatite coating in dogs. Clin Orthop 272:300–307PubMed
23.
go back to reference Thanner J, Karrholm J, Malchau H, Herberts P (1999) Poor outcome of the PCA and Harris-Galante hip prostheses. Randomized study of 171 artrhroplasties with 9-year follow-up. Acta Orthop Scand 70:155–162PubMed Thanner J, Karrholm J, Malchau H, Herberts P (1999) Poor outcome of the PCA and Harris-Galante hip prostheses. Randomized study of 171 artrhroplasties with 9-year follow-up. Acta Orthop Scand 70:155–162PubMed
24.
go back to reference Thanner J, Karrholm J, Herberts P, Malchau H (2000) Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips. J Arthroplasty 15:405–412CrossRefPubMed Thanner J, Karrholm J, Herberts P, Malchau H (2000) Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips. J Arthroplasty 15:405–412CrossRefPubMed
25.
go back to reference Tonino AJ, Rahmy AIA, International ABG study Group (2000) The hydroxyapatite—ABG hip system. 5 to 7 year results from an International Multicenter Study. J Arthroplasty 15:274–282PubMed Tonino AJ, Rahmy AIA, International ABG study Group (2000) The hydroxyapatite—ABG hip system. 5 to 7 year results from an International Multicenter Study. J Arthroplasty 15:274–282PubMed
Metadata
Title
Clinical and radiological results of hydroxyapatite-coated acetabular cups
Authors
J. Blacha
J. Gągała
Publication date
01-12-2004
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 6/2004
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-004-0563-0

Other articles of this Issue 6/2004

International Orthopaedics 6/2004 Go to the issue