Skip to main content
Top
Published in: International Orthopaedics 4/2003

01-08-2003 | Original Article

Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices

Authors: L. Audigé, B. Hanson, M. F. Swiontkowski

Published in: International Orthopaedics | Issue 4/2003

Login to get access

Abstract

The choice between dynamic screw-intramedullary nail (DSIN) devices and dynamic screw-plate (DSP) devices for the fixation of unstable trochanteric fractures remains controversial. This study presents a meta-analysis of fixation failures in unstable trochanteric femoral fractures using DSP devices or DSIN devices. Two independent assessors selected randomised controlled trials using a range of electronic databases, as well as reference lists of selected articles. A study quality checklist was used. The occurrence of fixation failure, in particular cut-out, was the primary subject of analysis using descriptive statistics and random-effect meta-analyses. Seventeen trials were identified. Meta-analyses showed no significant difference in the frequency of implant-related complications between the two types of devices. Iatrogenic femoral fractures associated with the use of DSIN devices represent a rare, but persistent, risk. There was a tendency for less frequent cut-out with intramedullary devices compared with DSP devices.
Literature
1.
go back to reference Adams CI, Robinson CM, Court-Brown CM, McQueen MM (2001) Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur. J Orthop Trauma 15:394–400CrossRefPubMed Adams CI, Robinson CM, Court-Brown CM, McQueen MM (2001) Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur. J Orthop Trauma 15:394–400CrossRefPubMed
2.
go back to reference Ahrengart L, Tornkvist H, Fornander P, Thorngren KG, Pasanen L, Wahlstrom P, Honkonen S, Lindgren U (2002) A randomized study of the compression hip screw and Gamma nail in 426 fractures. Clin Orthop 209–222 Ahrengart L, Tornkvist H, Fornander P, Thorngren KG, Pasanen L, Wahlstrom P, Honkonen S, Lindgren U (2002) A randomized study of the compression hip screw and Gamma nail in 426 fractures. Clin Orthop 209–222
3.
go back to reference Baumgaertner MR, Curtin SL, Lindskog DM (1998) Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop 348:87–94PubMed Baumgaertner MR, Curtin SL, Lindskog DM (1998) Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop 348:87–94PubMed
4.
go back to reference Bridle SH, Patel AD, Bircher M, Calvert PT (1991) Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw. J Bone Joint Surg [Br] 73:330–334 Bridle SH, Patel AD, Bircher M, Calvert PT (1991) Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw. J Bone Joint Surg [Br] 73:330–334
5.
go back to reference Butt MS, Krikler SJ, Nafie S, Ali MS (1995) Comparison of dynamic hip screw and gamma nail: a prospective, randomized, controlled trial. Injury 26:615–618CrossRefPubMed Butt MS, Krikler SJ, Nafie S, Ali MS (1995) Comparison of dynamic hip screw and gamma nail: a prospective, randomized, controlled trial. Injury 26:615–618CrossRefPubMed
6.
go back to reference Egger M, Smith GD, O'Rourke K (2001) Rationale, potentials, and promise of systematic reviews. In: Egger M, Smith G D, Altman DG (eds) Systematic Reviews in Health Care—meta-analysis in context. BMJ Publishing, London pp 3–19 Egger M, Smith GD, O'Rourke K (2001) Rationale, potentials, and promise of systematic reviews. In: Egger M, Smith G D, Altman DG (eds) Systematic Reviews in Health Care—meta-analysis in context. BMJ Publishing, London pp 3–19
7.
go back to reference Egger M, Smith GD, Phillips AN (1997) Meta-analysis: principles and procedures. BMJ 315:1533–1537PubMed Egger M, Smith GD, Phillips AN (1997) Meta-analysis: principles and procedures. BMJ 315:1533–1537PubMed
8.
go back to reference Fornander P, Thorngren K-G, Törnqvist H, Ahrengart L, Lindgren U (1994) Swedish experience with the Gamma nail versus sliding hip screw in 209 randomised cases. Int J Orthop Trauma 4:118–122 Fornander P, Thorngren K-G, Törnqvist H, Ahrengart L, Lindgren U (1994) Swedish experience with the Gamma nail versus sliding hip screw in 209 randomised cases. Int J Orthop Trauma 4:118–122
9.
go back to reference Gehrchen PM, Nielsen JO, Olesen B (1993) Poor reproducibility of Evans' classification of the trochanteric fracture. Assessment of 4 observers in 52 cases. Acta Orthop Scand 64:71–72PubMed Gehrchen PM, Nielsen JO, Olesen B (1993) Poor reproducibility of Evans' classification of the trochanteric fracture. Assessment of 4 observers in 52 cases. Acta Orthop Scand 64:71–72PubMed
10.
go back to reference Goldhagen PR, O'Connor DR, Schwarze D, Schwartz E (1994) A prospective comparative study of the compression hip screw and the gamma nail. J Orthop Trauma 8:367–372PubMed Goldhagen PR, O'Connor DR, Schwarze D, Schwartz E (1994) A prospective comparative study of the compression hip screw and the gamma nail. J Orthop Trauma 8:367–372PubMed
11.
go back to reference Guyer P, Landolt M, Keller H, Eberle C (1993) The Gamma nail in per- and intertrochanteric femoral fractures—alternative or complementary to the DHS? A prospective randomised study. In: Marti R K, Dunki Jacobs P B (eds) Proximal femoral fractures—operative technique and complications. Medical Press, London pp 481–498 Guyer P, Landolt M, Keller H, Eberle C (1993) The Gamma nail in per- and intertrochanteric femoral fractures—alternative or complementary to the DHS? A prospective randomised study. In: Marti R K, Dunki Jacobs P B (eds) Proximal femoral fractures—operative technique and complications. Medical Press, London pp 481–498
12.
go back to reference Hardy DC, Descamps PY, Krallis P, Fabeck L, Smets P, Bertens CL, Delince PE (1998) Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J.Bone Joint Surg [Am] 80:618–630 Hardy DC, Descamps PY, Krallis P, Fabeck L, Smets P, Bertens CL, Delince PE (1998) Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J.Bone Joint Surg [Am] 80:618–630
13.
go back to reference Harrington P, Nihal A, Singhania AK, Howell FR (2002) Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly. Injury 33:23–28CrossRefPubMed Harrington P, Nihal A, Singhania AK, Howell FR (2002) Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly. Injury 33:23–28CrossRefPubMed
14.
go back to reference Hoffmann R, Schmidmaier G, Schulz R, Schutz M, Sudkamp NP (1999) [Classic nail versus DHS. A prospective randomised study of fixation of trochanteric femur fractures]. Unfallchirurg 102:182–190CrossRefPubMed Hoffmann R, Schmidmaier G, Schulz R, Schutz M, Sudkamp NP (1999) [Classic nail versus DHS. A prospective randomised study of fixation of trochanteric femur fractures]. Unfallchirurg 102:182–190CrossRefPubMed
15.
go back to reference Johnstone DJ, Radford WJ, Parnell EJ (1993) Interobserver variation using the AO/ASIF classification of long bone fractures. Injury 24:163–165PubMed Johnstone DJ, Radford WJ, Parnell EJ (1993) Interobserver variation using the AO/ASIF classification of long bone fractures. Injury 24:163–165PubMed
16.
go back to reference Koval KJ, Zuckerman JD (2000) Hip fractures—a practical guide to management. Springer, Berlin Heidelberg New York Koval KJ, Zuckerman JD (2000) Hip fractures—a practical guide to management. Springer, Berlin Heidelberg New York
17.
go back to reference Kukla C, Heinz T, Berger G, Kwasny O, Rosenberger A, Vécsei V (1997) Gamma nail vs. dynamic hip screw in 120 patients over 60 years—a randomized trial. Acta Chir Austriaca 290–293 Kukla C, Heinz T, Berger G, Kwasny O, Rosenberger A, Vécsei V (1997) Gamma nail vs. dynamic hip screw in 120 patients over 60 years—a randomized trial. Acta Chir Austriaca 290–293
18.
go back to reference Kyle RF, Cabanela ME, Russell TA, Swiontkowski MF, Winquist RA, Zuckerman JD, Schmidt AH, Koval KJ (1994) Fractures of the proximal part of the femur. J Bone Joint Surg [Am] 76:924–950 Kyle RF, Cabanela ME, Russell TA, Swiontkowski MF, Winquist RA, Zuckerman JD, Schmidt AH, Koval KJ (1994) Fractures of the proximal part of the femur. J Bone Joint Surg [Am] 76:924–950
19.
go back to reference Leung KS, So WS, Shen WY, Hui PW (1992) Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients. J Bone Joint Surg [Br] 74:345–351 Leung KS, So WS, Shen WY, Hui PW (1992) Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients. J Bone Joint Surg [Br] 74:345–351
20.
go back to reference Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Stromsoe K (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. J Orthop Trauma 12:241–248CrossRefPubMed Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Stromsoe K (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. J Orthop Trauma 12:241–248CrossRefPubMed
21.
go back to reference O'Brien PJ, Meek RN, Blachut PA, Broekhuyse HM, Sabharwal S (1995) Fixation of intertrochanteric hip fractures: gamma nail versus dynamic hip screw. A randomized, prospective study. Can J Surg 38:516–520PubMed O'Brien PJ, Meek RN, Blachut PA, Broekhuyse HM, Sabharwal S (1995) Fixation of intertrochanteric hip fractures: gamma nail versus dynamic hip screw. A randomized, prospective study. Can J Surg 38:516–520PubMed
22.
go back to reference Pahlplatz PVM, Langius FB (1993) Comparing the gamma nail and the dynamic hip screw in the treatment of pertrochanteric fractures. Preliminary results of a prospective randomised study. In: Marti RK, Dunki Jacobs P B (eds) Proximal femoral fractures—operative techniques and complications. Medical Press, London pp 475–480 Pahlplatz PVM, Langius FB (1993) Comparing the gamma nail and the dynamic hip screw in the treatment of pertrochanteric fractures. Preliminary results of a prospective randomised study. In: Marti RK, Dunki Jacobs P B (eds) Proximal femoral fractures—operative techniques and complications. Medical Press, London pp 475–480
23.
go back to reference Park SR, Kang JS, Kim HS, Lee WH, Kim YH (1998) Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw—a randomised prospective trial. Int Orthop 22:157–160CrossRefPubMed Park SR, Kang JS, Kim HS, Lee WH, Kim YH (1998) Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw—a randomised prospective trial. Int Orthop 22:157–160CrossRefPubMed
24.
go back to reference Parker MJ, Handoll HH (2002) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures. In: The Cochrane Library, Update Software, Oxford Parker MJ, Handoll HH (2002) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures. In: The Cochrane Library, Update Software, Oxford
25.
go back to reference Parker MJ, Handoll HH, Bhonsle S, Gillespie WJ (2002) Condylocephalic nails versus extramedullary implants for extracapsular hip fractures. In: The Cochrane Library, Update Software, Oxford Parker MJ, Handoll HH, Bhonsle S, Gillespie WJ (2002) Condylocephalic nails versus extramedullary implants for extracapsular hip fractures. In: The Cochrane Library, Update Software, Oxford
26.
go back to reference Walheim G, Barrios C, Stark A, Brostrom LA, Olsson E (1990) Postoperative improvement of walking capacity in patients with trochanteric hip fracture: a prospective analysis 3 and 6 months after surgery. J Orthop Trauma 4:137–143PubMed Walheim G, Barrios C, Stark A, Brostrom LA, Olsson E (1990) Postoperative improvement of walking capacity in patients with trochanteric hip fracture: a prospective analysis 3 and 6 months after surgery. J Orthop Trauma 4:137–143PubMed
Metadata
Title
Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices
Authors
L. Audigé
B. Hanson
M. F. Swiontkowski
Publication date
01-08-2003
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 4/2003
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-003-0457-6

Other articles of this Issue 4/2003

International Orthopaedics 4/2003 Go to the issue