Skip to main content
Top
Published in: European Journal of Nuclear Medicine and Molecular Imaging 4/2012

01-04-2012 | Original Article

The reliability of glomerular filtration rate measured from plasma clearance: a multi-centre study of 1,878 healthy potential renal transplant donors

Authors: A. Michael Peters, Bethany Howard, Mark D. J. Neilly, Nagabhushan Seshadri, Ravin Sobnack, Claire A. Hooker, Andrew Irwin, Hayley Snelling, Thomas Gruning, Laura Perry, Neva H. Patel, Richard S. Lawson, Gregory Shabo, Nigel Williams, Surendra Dave, Mark C Barnfield

Published in: European Journal of Nuclear Medicine and Molecular Imaging | Issue 4/2012

Login to get access

Abstract

Purpose

The objective of the study was to undertake a clinical audit of departmental performance in the measurement of glomerular filtration rate (GFR) using the coefficient of variation (CV) of extracellular fluid volume (ECFV) as the benchmark. ECFV is held within narrow limits in healthy subjects, narrower than GFR, and should therefore have a low CV.

Methods

Fifteen departments participated in this retrospective study of healthy renal transplant donors. Data were analysed separately for men (n ranged from 28 to 115 per centre; total = 819) and women (n = 28–146; 1,059). All centres used the slope-intercept method with blood sample numbers ranging from two to five. Subjects did not fast prior to GFR measurement. GFR was scaled to body surface area (BSA) and corrected for the single compartment assumption. GFR scaled to ECFV was calculated as the terminal slope rate constant and corrected for the single compartment assumption. ECFV/BSA was calculated as the ratio of GFR/BSA to GFR/ECFV.

Results

The departmental CVs of ECFV/BSA and GFR/BSA ranged from 8.3 to 25.8% and 12.8 to 21.9%, respectively, in men, and from 9.6 to 21.1% and 14.8 to 23.7%, respectively, in women. Both CVs correlated strongly between men and women from the same centre, suggesting department-specific systematic errors. GFR/BSA was higher in men in 14 of 15 centres, whereas GFR/ECFV was higher in women in 14 of 15 centres. Both correlated strongly between men and women, suggesting regional variation in GFR.

Conclusion

The CV of ECFV/BSA in normal subjects is a useful indicator of the technical robustness with which GFR is measured and, in this study, indicated a wide variation in departmental performance.
Literature
1.
go back to reference Bröchner-Mortensen J, Giese J, Rossing N. Renal inulin clearance versus total plasma clearance of 51Cr-EDTA. Scand J Clin Lab Invest 1969;23:301–5.PubMedCrossRef Bröchner-Mortensen J, Giese J, Rossing N. Renal inulin clearance versus total plasma clearance of 51Cr-EDTA. Scand J Clin Lab Invest 1969;23:301–5.PubMedCrossRef
3.
go back to reference Chantler C, Garnett ES, Parsons V, Veall N. Glomerular filtration rate measurement in man by the single injection method using 51Cr-EDTA. Clin Sci 1969;37:169–80.PubMed Chantler C, Garnett ES, Parsons V, Veall N. Glomerular filtration rate measurement in man by the single injection method using 51Cr-EDTA. Clin Sci 1969;37:169–80.PubMed
4.
go back to reference Gaspari F, Perico N, Ruggenenti P, Mosconi L, Amuchastequi CS, Guerini E, et al. Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate. J Am Soc Nephrol 1995;6:257–63.PubMed Gaspari F, Perico N, Ruggenenti P, Mosconi L, Amuchastequi CS, Guerini E, et al. Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate. J Am Soc Nephrol 1995;6:257–63.PubMed
5.
go back to reference Peters AM. Expressing glomerular filtration rate in terms of extracellular fluid volume. Nephrol Dial Transplant 1992;7:205–10.PubMed Peters AM. Expressing glomerular filtration rate in terms of extracellular fluid volume. Nephrol Dial Transplant 1992;7:205–10.PubMed
6.
go back to reference Bird NJ, Michell AR, Peters AM. Accurate measurement of extracellular fluid volume from the slope/intercept technique after bolus injection of a filtration marker. Physiol Meas 2009;30:1371–9.PubMedCrossRef Bird NJ, Michell AR, Peters AM. Accurate measurement of extracellular fluid volume from the slope/intercept technique after bolus injection of a filtration marker. Physiol Meas 2009;30:1371–9.PubMedCrossRef
7.
go back to reference Cowley Jr AW, Roman RJ. Control of blood and extracellular volume. Baillieres Clin Endocrinol Metab 1989;3:331–69.PubMedCrossRef Cowley Jr AW, Roman RJ. Control of blood and extracellular volume. Baillieres Clin Endocrinol Metab 1989;3:331–69.PubMedCrossRef
8.
go back to reference Skorecki KL, Brenner BM. Body fluid homeostasis in man. A contemporary overview. Am J Med 1981;70:77–88.PubMedCrossRef Skorecki KL, Brenner BM. Body fluid homeostasis in man. A contemporary overview. Am J Med 1981;70:77–88.PubMedCrossRef
9.
go back to reference Peters AM. The kinetic basis of glomerular filtration rate measurement and new concepts of indexation to body size. Eur J Nucl Med Mol Imaging 2004;31:137–49.PubMedCrossRef Peters AM. The kinetic basis of glomerular filtration rate measurement and new concepts of indexation to body size. Eur J Nucl Med Mol Imaging 2004;31:137–49.PubMedCrossRef
10.
go back to reference Haycock GB, Schwartz GJ, Wisotsky DH. Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults. J Pediatr 1978;93:62–6.PubMedCrossRef Haycock GB, Schwartz GJ, Wisotsky DH. Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults. J Pediatr 1978;93:62–6.PubMedCrossRef
11.
go back to reference Bröchner-Mortensen J. A simple method for the determination of glomerular filtration rate. Scand J Clin Lab Invest 1972;30:271–4.PubMedCrossRef Bröchner-Mortensen J. A simple method for the determination of glomerular filtration rate. Scand J Clin Lab Invest 1972;30:271–4.PubMedCrossRef
12.
go back to reference Boer P. Estimated lean body mass as an index for normalization of body fluid volumes in man. Am J Physiol 1984;247:F632–5.PubMed Boer P. Estimated lean body mass as an index for normalization of body fluid volumes in man. Am J Physiol 1984;247:F632–5.PubMed
13.
go back to reference Bird NJ, Peters C, Michell AR, Peters AM. Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate. Nucl Med Commun 2008;29:1086–92.PubMedCrossRef Bird NJ, Peters C, Michell AR, Peters AM. Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate. Nucl Med Commun 2008;29:1086–92.PubMedCrossRef
14.
go back to reference Vervoort G, Willems HL, Wetzels JFM. Assessment of glomerular filtration rate in healthy subjects and normoalbuminuric diabetic patients: validity of a new (MDRD) prediction equation. Nephrol Dial Transplant 2002;17:1909–13.PubMedCrossRef Vervoort G, Willems HL, Wetzels JFM. Assessment of glomerular filtration rate in healthy subjects and normoalbuminuric diabetic patients: validity of a new (MDRD) prediction equation. Nephrol Dial Transplant 2002;17:1909–13.PubMedCrossRef
15.
go back to reference Bird NJ, Peters C, Michell AR, Peters AM. Association between glomerular filtration rate and extracellular fluid volume in normal subjects and patients with renal impairment. Scand J Clin Lab Invest 2008;68:39–49.PubMedCrossRef Bird NJ, Peters C, Michell AR, Peters AM. Association between glomerular filtration rate and extracellular fluid volume in normal subjects and patients with renal impairment. Scand J Clin Lab Invest 2008;68:39–49.PubMedCrossRef
16.
go back to reference Simon AHR, Lima PRM, Almerinda M, Ribeiro Alves VF, Bottini PV, Lopes de Faria JB. Renal haemodynamic responses to a chicken or beef meal in normal individuals. Nephrol Dial Transplant 1998;13:2261–4.PubMedCrossRef Simon AHR, Lima PRM, Almerinda M, Ribeiro Alves VF, Bottini PV, Lopes de Faria JB. Renal haemodynamic responses to a chicken or beef meal in normal individuals. Nephrol Dial Transplant 1998;13:2261–4.PubMedCrossRef
17.
go back to reference Wesson LG. Renal hemodynamics in physiological states. In: Wesson LG, editor. Physiology of the human kidney. New York: Grune & Stratton; 1969. p. 96–108. Wesson LG. Renal hemodynamics in physiological states. In: Wesson LG, editor. Physiology of the human kidney. New York: Grune & Stratton; 1969. p. 96–108.
18.
go back to reference Poulsen HL, Jensen HE, Parving HH. Extracellular fluid volume determined by a single injection of inulin in men with untreated essential hypertension. Scand J Clin Lab Invest 1977;37:691–6.PubMedCrossRef Poulsen HL, Jensen HE, Parving HH. Extracellular fluid volume determined by a single injection of inulin in men with untreated essential hypertension. Scand J Clin Lab Invest 1977;37:691–6.PubMedCrossRef
19.
go back to reference Ladegaard-Pedersen HJ. Measurement of extracellular volume and renal clearance by a single injection of inulin. Scand J Clin Lab Invest 1972;29:145–53.PubMedCrossRef Ladegaard-Pedersen HJ. Measurement of extracellular volume and renal clearance by a single injection of inulin. Scand J Clin Lab Invest 1972;29:145–53.PubMedCrossRef
20.
go back to reference Bird NJ, Peters C, Michell AR, Peters AM. Comparison of GFR measurements assessed from single versus multiple samples. Am J Kidney Dis 2009;54:278–88.PubMedCrossRef Bird NJ, Peters C, Michell AR, Peters AM. Comparison of GFR measurements assessed from single versus multiple samples. Am J Kidney Dis 2009;54:278–88.PubMedCrossRef
Metadata
Title
The reliability of glomerular filtration rate measured from plasma clearance: a multi-centre study of 1,878 healthy potential renal transplant donors
Authors
A. Michael Peters
Bethany Howard
Mark D. J. Neilly
Nagabhushan Seshadri
Ravin Sobnack
Claire A. Hooker
Andrew Irwin
Hayley Snelling
Thomas Gruning
Laura Perry
Neva H. Patel
Richard S. Lawson
Gregory Shabo
Nigel Williams
Surendra Dave
Mark C Barnfield
Publication date
01-04-2012
Publisher
Springer-Verlag
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue 4/2012
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-011-2024-5

Other articles of this Issue 4/2012

European Journal of Nuclear Medicine and Molecular Imaging 4/2012 Go to the issue