Published in: European Journal of Nuclear Medicine and Molecular Imaging 1/2011

Open Access 01-05-2011 | Review Article

Quantitative imaging of 124I and 86Y with PET

Authors: Mark Lubberink, Hans Herzog

Published in: European Journal of Nuclear Medicine and Molecular Imaging | Special Issue 1/2011

Login to get access

Abstract

The quantitative accuracy and image quality of positron emission tomography (PET) measurements with 124I and 86Y is affected by the prompt emission of gamma radiation and positrons in their decays, as well as the higher energy of the emitted positrons compared to those emitted by 18F. PET scanners cannot distinguish between true coincidences, involving two 511-keV annihilation photons, and coincidences involving one annihilation photon and a prompt gamma, if the energy of this prompt gamma is within the energy window of the scanner. The current review deals with a number of aspects of the challenge this poses for quantitative PET imaging. First, the effect of prompt gamma coincidences on quantitative accuracy of PET images is discussed and a number of suggested corrections are described. Then, the effect of prompt gamma coincidences and the increased singles count rates due to gamma radiation on the count rate performance of PET is addressed, as well as possible improvements based on modification of the scanner’s energy windows. Finally, the effect of positron energy on spatial resolution and recovery is assessed. The methods presented in this overview aim to overcome the challenges associated with the decay characteristics of 124I and 86Y. Careful application of the presented correction methods can allow for quantitatively accurate images with improved image contrast.
Literature
1.
go back to reference Jentzen W. Experimental investigation of factors affecting the absolute recovery coefficients in iodine-124 PET lesion imaging. Phys Med Biol 2010;55(8):2365–98.PubMedCrossRef Jentzen W. Experimental investigation of factors affecting the absolute recovery coefficients in iodine-124 PET lesion imaging. Phys Med Biol 2010;55(8):2365–98.PubMedCrossRef
2.
go back to reference Perk LR, Visser GW, Vosjan MJ, Stigter-van Walsum M, Tijink BM, Leemans CR, et al. (89)Zr as a PET surrogate radioisotope for scouting biodistribution of the therapeutic radiometals (90)Y and (177)Lu in tumor-bearing nude mice after coupling to the internalizing antibody cetuximab. J Nucl Med 2005;46(11):1898–906.PubMed Perk LR, Visser GW, Vosjan MJ, Stigter-van Walsum M, Tijink BM, Leemans CR, et al. (89)Zr as a PET surrogate radioisotope for scouting biodistribution of the therapeutic radiometals (90)Y and (177)Lu in tumor-bearing nude mice after coupling to the internalizing antibody cetuximab. J Nucl Med 2005;46(11):1898–906.PubMed
3.
go back to reference Martin CC, Christian BT, Satter MR, Nickerson LDH, Nickles RJ. Quantitative PET with positron emitters that emit prompt gamma rays. IEEE Trans Med Imaging 1995;14(4):681–7.PubMedCrossRef Martin CC, Christian BT, Satter MR, Nickerson LDH, Nickles RJ. Quantitative PET with positron emitters that emit prompt gamma rays. IEEE Trans Med Imaging 1995;14(4):681–7.PubMedCrossRef
4.
go back to reference Lubberink M, Schneider H, Bergström M, Lundqvist H. Quantitative imaging and correction for cascade gamma radiation of 76Br with 2D and 3D PET. Phys Med Biol 2002;47(19):3519–34.PubMedCrossRef Lubberink M, Schneider H, Bergström M, Lundqvist H. Quantitative imaging and correction for cascade gamma radiation of 76Br with 2D and 3D PET. Phys Med Biol 2002;47(19):3519–34.PubMedCrossRef
5.
go back to reference Walrand S, Jamar F, Mathieu I, De Camps J, Lonneux M, Sibomana M, et al. Quantitation in PET using isotopes emitting prompt single gammas: application to yttrium-86. Eur J Nucl Med Mol Imaging 2003;30(3):354–61.PubMedCrossRef Walrand S, Jamar F, Mathieu I, De Camps J, Lonneux M, Sibomana M, et al. Quantitation in PET using isotopes emitting prompt single gammas: application to yttrium-86. Eur J Nucl Med Mol Imaging 2003;30(3):354–61.PubMedCrossRef
6.
go back to reference Beattie BJ, Finn RD, Rowland DJ, Pentlow KS. Quantitative imaging of bromine-76 and yttrium-86 with PET: a method for the removal of spurious activity introduced by cascade gamma rays. Med Phys 2003;30(9):2410–23.PubMedCrossRef Beattie BJ, Finn RD, Rowland DJ, Pentlow KS. Quantitative imaging of bromine-76 and yttrium-86 with PET: a method for the removal of spurious activity introduced by cascade gamma rays. Med Phys 2003;30(9):2410–23.PubMedCrossRef
7.
go back to reference Lubberink M, van Schie A, de Jong HW, van Dongen GA, Teule GJ. Acquisition settings for PET of 124I administered simultaneously with therapeutic amounts of 131I. J Nucl Med 2006;47(8):1375–81.PubMed Lubberink M, van Schie A, de Jong HW, van Dongen GA, Teule GJ. Acquisition settings for PET of 124I administered simultaneously with therapeutic amounts of 131I. J Nucl Med 2006;47(8):1375–81.PubMed
8.
go back to reference Monaro S, Vingiani GB, van Lieshout R. Aspects of decay of 27Mg and of 89Zr. Physica 1961;27(10):985–993.CrossRef Monaro S, Vingiani GB, van Lieshout R. Aspects of decay of 27Mg and of 89Zr. Physica 1961;27(10):985–993.CrossRef
9.
go back to reference Kolthammer JA, Salem N, Fiedler K, Gagnon D. Downscatter contamination from high-energy photons of 124I in 2D and 3D PET. IEEE Nucl Sci Symp Conf Rec 2004;6:3629–33.CrossRef Kolthammer JA, Salem N, Fiedler K, Gagnon D. Downscatter contamination from high-energy photons of 124I in 2D and 3D PET. IEEE Nucl Sci Symp Conf Rec 2004;6:3629–33.CrossRef
10.
go back to reference Herzog H, Tellmann L, Qaim SM, Spellerberg S, Schmid A, Coenen HH. PET quantitation and imaging of the non-pure positron-emitting iodine isotope 124I. Appl Radiat Isot 2002;56(5):673–9.PubMedCrossRef Herzog H, Tellmann L, Qaim SM, Spellerberg S, Schmid A, Coenen HH. PET quantitation and imaging of the non-pure positron-emitting iodine isotope 124I. Appl Radiat Isot 2002;56(5):673–9.PubMedCrossRef
11.
go back to reference Pentlow KS, Graham MC, Lambrecht RM, Cheung NK, Larson SM. Quantitative imaging of I-124 using positron emission tomography with applications to radioimmunodiagnosis and radioimmunotherapy. Med Phys 1991;18(3):357–66.PubMedCrossRef Pentlow KS, Graham MC, Lambrecht RM, Cheung NK, Larson SM. Quantitative imaging of I-124 using positron emission tomography with applications to radioimmunodiagnosis and radioimmunotherapy. Med Phys 1991;18(3):357–66.PubMedCrossRef
12.
go back to reference Pentlow KS, Graham MC, Lambrecht RM, Daghighian F, Bacharach SL, Bendriem B, et al. Quantitative imaging of iodine-124 with PET. J Nucl Med 1996;37(9):1557–62.PubMed Pentlow KS, Graham MC, Lambrecht RM, Daghighian F, Bacharach SL, Bendriem B, et al. Quantitative imaging of iodine-124 with PET. J Nucl Med 1996;37(9):1557–62.PubMed
13.
go back to reference Lubberink M, Lundqvist H, Westlin JE, Tolmachev V, Schneider H, Lövqvist A, et al. Positron emission tomography and radioimmunotargeting–aspects of quantification and dosimetry. Acta Oncol 1999;38(3):343–9.PubMedCrossRef Lubberink M, Lundqvist H, Westlin JE, Tolmachev V, Schneider H, Lövqvist A, et al. Positron emission tomography and radioimmunotargeting–aspects of quantification and dosimetry. Acta Oncol 1999;38(3):343–9.PubMedCrossRef
14.
go back to reference Pentlow KS, Finn RD, Larson SM, Erdi YE, Beattie BJ, Humm JL. Quantitative imaging of yttrium-86 with PET. The occurrence and correction of anomalous apparent activity in high density regions. Clin Positron Imaging 2000;3(3):85–90.PubMedCrossRef Pentlow KS, Finn RD, Larson SM, Erdi YE, Beattie BJ, Humm JL. Quantitative imaging of yttrium-86 with PET. The occurrence and correction of anomalous apparent activity in high density regions. Clin Positron Imaging 2000;3(3):85–90.PubMedCrossRef
15.
go back to reference Kull T, Ruckgaber J, Weller R, Reske S, Glatting G. Quantitative imaging of yttrium-86 PET with the ECAT EXACT HR+ in 2D mode. Cancer Biother Radiopharm 2004;19(4):482–90.PubMed Kull T, Ruckgaber J, Weller R, Reske S, Glatting G. Quantitative imaging of yttrium-86 PET with the ECAT EXACT HR+ in 2D mode. Cancer Biother Radiopharm 2004;19(4):482–90.PubMed
16.
go back to reference Herzog H, Tellmann L, Scholten B, Coenen HH, Qaim SM. PET imaging problems with the non-standard positron emitters yttrium-86 and iodine-124. Q J Nucl Med Mol Imaging 2008;52(2):159–65.PubMed Herzog H, Tellmann L, Scholten B, Coenen HH, Qaim SM. PET imaging problems with the non-standard positron emitters yttrium-86 and iodine-124. Q J Nucl Med Mol Imaging 2008;52(2):159–65.PubMed
17.
go back to reference Buchholz HG, Herzog H, Förster GJ, Reber H, Nickel O, Rösch F, et al. PET imaging with yttrium-86: comparison of phantom measurements acquired with different PET scanners before and after applying background subtraction. Eur J Nucl Med Mol Imaging 2003;30(5):716–20.PubMedCrossRef Buchholz HG, Herzog H, Förster GJ, Reber H, Nickel O, Rösch F, et al. PET imaging with yttrium-86: comparison of phantom measurements acquired with different PET scanners before and after applying background subtraction. Eur J Nucl Med Mol Imaging 2003;30(5):716–20.PubMedCrossRef
18.
go back to reference Bergström M, Eriksson L, Bohm C, Blomqvist G, Litton J. Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections. J Comput Assist Tomogr 1983;7(1):42–50.PubMedCrossRef Bergström M, Eriksson L, Bohm C, Blomqvist G, Litton J. Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections. J Comput Assist Tomogr 1983;7(1):42–50.PubMedCrossRef
19.
go back to reference Schweizer B, von Busch H. Koninklijke Philips Electronics, assignee. Dirty isotope PET reconstruction. United States patent 20090057561. 2009. Schweizer B, von Busch H. Koninklijke Philips Electronics, assignee. Dirty isotope PET reconstruction. United States patent 20090057561. 2009.
20.
go back to reference Watson CC. New, faster, image-based scatter correction for 3D PET. IEEE Trans Nucl Sci 2000;47(4):1587–94.CrossRef Watson CC. New, faster, image-based scatter correction for 3D PET. IEEE Trans Nucl Sci 2000;47(4):1587–94.CrossRef
21.
go back to reference Gregory R, Partridge M, Flux GD. Assessment of cascade correction methods for quantitative 124I PET imaging. Eur J Nucl Med Mol Imaging 2009;36:OP066.CrossRef Gregory R, Partridge M, Flux GD. Assessment of cascade correction methods for quantitative 124I PET imaging. Eur J Nucl Med Mol Imaging 2009;36:OP066.CrossRef
22.
go back to reference Surti S, Scheuermann R, Karp JS. Correction technique for cascade gammas in I-124 imaging on a fully-3D, time-of-flight PET scanner. IEEE Trans Nucl Sci 2009;56(3):653–60.PubMedCrossRef Surti S, Scheuermann R, Karp JS. Correction technique for cascade gammas in I-124 imaging on a fully-3D, time-of-flight PET scanner. IEEE Trans Nucl Sci 2009;56(3):653–60.PubMedCrossRef
23.
go back to reference Lubberink M. Quantitative imaging with PET - performance and applications of 76Br, 52Fe, 110mIn and 134La. Uppsala: Acta Universitatis Upsaliensis. Comprehensive summaries of Uppsala dissertations from the faculty of medicine 2001;1034. Lubberink M. Quantitative imaging with PET - performance and applications of 76Br, 52Fe, 110mIn and 134La. Uppsala: Acta Universitatis Upsaliensis. Comprehensive summaries of Uppsala dissertations from the faculty of medicine 2001;1034.
24.
go back to reference Watson CC, Hayden C, Casey ME, Hamill J, Bendriem B. Prompt gamma correction for improved quantification in 82Rb PET. J Nucl Med 2008;49:64P.CrossRef Watson CC, Hayden C, Casey ME, Hamill J, Bendriem B. Prompt gamma correction for improved quantification in 82Rb PET. J Nucl Med 2008;49:64P.CrossRef
25.
go back to reference Hayden CH, Casey ME, Watson CC. Siemens Medical Solutions, assignee. Prompt gamma correction for non-standard isotopes in a PET scanner. United States patent 20080283758. 2008. Hayden CH, Casey ME, Watson CC. Siemens Medical Solutions, assignee. Prompt gamma correction for non-standard isotopes in a PET scanner. United States patent 20080283758. 2008.
26.
go back to reference Strother SC, Casey ME, Hoffman EJ. Measuring PET scanner sensitivity: relating count rates to image signal-to-noise ratios using noise equivalent counts. IEEE Trans Nucl Sci 1990;37(2):783–8.CrossRef Strother SC, Casey ME, Hoffman EJ. Measuring PET scanner sensitivity: relating count rates to image signal-to-noise ratios using noise equivalent counts. IEEE Trans Nucl Sci 1990;37(2):783–8.CrossRef
27.
go back to reference de Jong HW, Lubberink M, Watabe H, Iida H, Lammertsma AA. A method to measure PET scatter fractions for daily quality control. Med Phys 2009;36(10):4609–15.PubMedCrossRef de Jong HW, Lubberink M, Watabe H, Iida H, Lammertsma AA. A method to measure PET scatter fractions for daily quality control. Med Phys 2009;36(10):4609–15.PubMedCrossRef
28.
go back to reference Gregory RA, Hooker CA, Partridge M, Flux GD. Optimization and assessment of quantitative 124I imaging on a Philips Gemini dual GS PET/CT system. Eur J Nucl Med Mol Imaging 2009;36(7):1037–48.PubMedCrossRef Gregory RA, Hooker CA, Partridge M, Flux GD. Optimization and assessment of quantitative 124I imaging on a Philips Gemini dual GS PET/CT system. Eur J Nucl Med Mol Imaging 2009;36(7):1037–48.PubMedCrossRef
29.
go back to reference Lubberink M, Schneider H, Bergström M, Lundqvist H. Count rate characteristics of PET with bromine-76. Eur J Nucl Med 2001;28(8):1008. Lubberink M, Schneider H, Bergström M, Lundqvist H. Count rate characteristics of PET with bromine-76. Eur J Nucl Med 2001;28(8):1008.
30.
go back to reference Vandenberghe S. Three-dimensional positron emission tomography imaging with 124I and 86Y. Nucl Med Commun 2006;27(3):237–45.PubMedCrossRef Vandenberghe S. Three-dimensional positron emission tomography imaging with 124I and 86Y. Nucl Med Commun 2006;27(3):237–45.PubMedCrossRef
31.
go back to reference Bol K. Performance, quality and optimization of 124I imaged with the Phillips GEMINI TF PET/CT [Master’s thesis]. Amsterdam: VU University; 2009. Bol K. Performance, quality and optimization of 124I imaged with the Phillips GEMINI TF PET/CT [Master’s thesis]. Amsterdam: VU University; 2009.
32.
go back to reference Moses WW, Derenzo SE. Empirical observation of resolution degradation in positron emission tomographs utilizing block detectors. J Nucl Med 1993;34:101P. Moses WW, Derenzo SE. Empirical observation of resolution degradation in positron emission tomographs utilizing block detectors. J Nucl Med 1993;34:101P.
33.
go back to reference ICRP Publication 38: Radionuclide transformations: energy and intensity of emissions. Ottawa: International Commission on Radiological Protection; 1983. ICRP Publication 38: Radionuclide transformations: energy and intensity of emissions. Ottawa: International Commission on Radiological Protection; 1983.
34.
go back to reference Evans RD. The atomic nucleus. New York: McGraw-Hill; 1972. Evans RD. The atomic nucleus. New York: McGraw-Hill; 1972.
35.
go back to reference González Trotter DE, Manjeshwar RM, Doss M, Shaller C, Robinson MK, Tandon R, et al. Quantitation of small-animal (124)I activity distributions using a clinical PET/CT scanner. J Nucl Med 2004;45(7):1237–44.PubMed González Trotter DE, Manjeshwar RM, Doss M, Shaller C, Robinson MK, Tandon R, et al. Quantitation of small-animal (124)I activity distributions using a clinical PET/CT scanner. J Nucl Med 2004;45(7):1237–44.PubMed
36.
go back to reference Bading JR, Hörling M, Williams LE, Colcher D, Raubitschek A, Strand SE. Quantitative serial imaging of an 124I anti-CEA monoclonal antibody in tumor-bearing mice. Cancer Biother Radiopharm 2008;23(4):399–409.PubMedCrossRef Bading JR, Hörling M, Williams LE, Colcher D, Raubitschek A, Strand SE. Quantitative serial imaging of an 124I anti-CEA monoclonal antibody in tumor-bearing mice. Cancer Biother Radiopharm 2008;23(4):399–409.PubMedCrossRef
37.
go back to reference Zhu X, El Fakhri G. Monte Carlo modeling of cascade gamma rays in (86)Y PET imaging: preliminary results. Phys Med Biol 2009;54(13):4181–93.PubMedCrossRef Zhu X, El Fakhri G. Monte Carlo modeling of cascade gamma rays in (86)Y PET imaging: preliminary results. Phys Med Biol 2009;54(13):4181–93.PubMedCrossRef
38.
go back to reference Jentzen W, Weise R, Kupferschläger J, Freudenberg L, Brandau W, Bares R, et al. Iodine-124 PET dosimetry in differentiated thyroid cancer: recovery coefficient in 2D and 3D modes for PET(/CT) systems. Eur J Nucl Med Mol Imaging 2008;35(3):611–23.PubMedCrossRef Jentzen W, Weise R, Kupferschläger J, Freudenberg L, Brandau W, Bares R, et al. Iodine-124 PET dosimetry in differentiated thyroid cancer: recovery coefficient in 2D and 3D modes for PET(/CT) systems. Eur J Nucl Med Mol Imaging 2008;35(3):611–23.PubMedCrossRef
40.
go back to reference Surti S, Kuhn A, Werner ME, Perkins AE, Kolthammer J, Karp JS. Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities. J Nucl Med 2007;48(3):471–80.PubMed Surti S, Kuhn A, Werner ME, Perkins AE, Kolthammer J, Karp JS. Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities. J Nucl Med 2007;48(3):471–80.PubMed
Metadata
Title
Quantitative imaging of 124I and 86Y with PET
Authors
Mark Lubberink
Hans Herzog
Publication date
01-05-2011
Publisher
Springer-Verlag
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue Special Issue 1/2011
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-011-1768-2

Other articles of this Special Issue 1/2011

European Journal of Nuclear Medicine and Molecular Imaging 1/2011 Go to the issue