Skip to main content
Top
Published in: Skeletal Radiology 3/2024

18-08-2023 | Scientific Article

2D shear wave elastography for the assessment of quadriceps entheses—a methodological study

Authors: Sook Sam Leong, Jeannie Hsiu Ding Wong, Faizatul Izza Rozalli, Fariz Yahya, Ying Chew Tee, Lyana Shahirah Mohamad Yamin, Mazuin Mohd Razalli, Hazlyna Baharuddin

Published in: Skeletal Radiology | Issue 3/2024

Login to get access

Abstract

Objective

To establish the scanning protocol for 2-dimensional shear wave elastography (SWE) on normal entheses by investigating the possible confounding factors that may increase the variability of measured elasticity.

Material and methods

30 normal quadriceps entheses were scanned using SWE to compare the stiffness and coefficient variation by changing the ultrasonic coupling gel thickness, knee position, region of interest size, and scanning plane.

Results

No significant difference in median shear wave velocity (SWV) was observed in different coupling gel thicknesses. The median SWV was higher in the knee flexion position than in the extended position (p < 0.001). Increased knee flexion led to stiffer quadriceps enthesis and higher SWV (ρ = 0.8, p < 0.001). The median SWV was higher when the diameter region of interest was 4.0 mm than 2.0 mm (p = 0.001). The median SWV was higher in the transverse plane than in the longitudinal plane (p < 0.001). Strong correlation was found between SWV and the degree of the shear wave to muscle fiber direction (ρ = 0.8, p < 0.001). The coefficient variation was lower in a gel thickness of 2.5 cm, with an extended knee, a region of interest of 2.0 mm, and a longitudinal plane (p > 0.05). For interobserver reliability for the proposed protocol, the intraclass correlation coefficients was 0.763.

Conclusion

In this study, we determined supine position with the knee extended; using 2.0 mm diameter region of interest and image acquisition at the longitudinal plane with thicker layer coupling gel seems most appropriate to reliably image healthy quadriceps entheses with SWE.
Literature
1.
go back to reference Lu HH, Thomopoulos S. Functional attachment of soft tissues to bone: development, healing, and tissue engineering. Annu Rev Biomed. 2013;15:201.CrossRef Lu HH, Thomopoulos S. Functional attachment of soft tissues to bone: development, healing, and tissue engineering. Annu Rev Biomed. 2013;15:201.CrossRef
2.
go back to reference Claudepierre P, Voisin M-C. The entheses: histology, pathology, and pathophysiology. Jt Bone Spine. 2005;72(1):32–7.CrossRef Claudepierre P, Voisin M-C. The entheses: histology, pathology, and pathophysiology. Jt Bone Spine. 2005;72(1):32–7.CrossRef
3.
go back to reference Zabotti A, Bandinelli F, Batticciotto A, Scire CA, Iagnocco A, Sakellariou G, et al. Musculoskeletal ultrasonography for psoriatic arthritis and psoriasis patients: a systematic literature review. Rheumatology. 2017;56(9):1518–32.CrossRefPubMed Zabotti A, Bandinelli F, Batticciotto A, Scire CA, Iagnocco A, Sakellariou G, et al. Musculoskeletal ultrasonography for psoriatic arthritis and psoriasis patients: a systematic literature review. Rheumatology. 2017;56(9):1518–32.CrossRefPubMed
4.
go back to reference Elsherbiny DA, Habeeb RA, Rahman MAA, Mustafa HA, Hussein SA. Lower limb entheseal involvement in systemic lupus erythematosus patients: relation to disease activity. Egypt Rheumatologist. 2021;43(4):305–9.CrossRef Elsherbiny DA, Habeeb RA, Rahman MAA, Mustafa HA, Hussein SA. Lower limb entheseal involvement in systemic lupus erythematosus patients: relation to disease activity. Egypt Rheumatologist. 2021;43(4):305–9.CrossRef
5.
go back to reference Tang Y, Cheng S, Yang Y, Xiang X, Wang L, Zhang L, et al. Ultrasound assessment in psoriatic arthritis (PsA) and psoriasis vulgaris (non-PsA): which sites are most commonly involved and what features are more important in PsA? Quant Imaging Med Surg. 2020;10(1):86.CrossRefPubMedPubMedCentral Tang Y, Cheng S, Yang Y, Xiang X, Wang L, Zhang L, et al. Ultrasound assessment in psoriatic arthritis (PsA) and psoriasis vulgaris (non-PsA): which sites are most commonly involved and what features are more important in PsA? Quant Imaging Med Surg. 2020;10(1):86.CrossRefPubMedPubMedCentral
6.
go back to reference Eder L, Barzilai M, Peled N, Gladman DD, Zisman D. The use of ultrasound for the assessment of enthesitis in patients with spondyloarthritis. Clin Radiol. 2013;68(3):219–23.CrossRefPubMed Eder L, Barzilai M, Peled N, Gladman DD, Zisman D. The use of ultrasound for the assessment of enthesitis in patients with spondyloarthritis. Clin Radiol. 2013;68(3):219–23.CrossRefPubMed
7.
go back to reference Molina Collada J, Macía-Villa C, Plasencia C, Álvaro-Gracia JM, de Miguel E. Doppler enthesitis: a potential useful outcome in the assessment of axial spondyloarthritis and psoriatic arthritis. Clin Rheumatol. 2021;40:2013–20.CrossRefPubMed Molina Collada J, Macía-Villa C, Plasencia C, Álvaro-Gracia JM, de Miguel E. Doppler enthesitis: a potential useful outcome in the assessment of axial spondyloarthritis and psoriatic arthritis. Clin Rheumatol. 2021;40:2013–20.CrossRefPubMed
8.
go back to reference Wervers K, Vis M, Rasappu N, van der Ven M, Tchetverikov I, Kok MR, et al. Modification of a sonographic enthesitis score to differentiate between psoriatic arthritis and young healthy volunteers. Scand J Rheumatol. 2018;47(4):291–4.CrossRefPubMed Wervers K, Vis M, Rasappu N, van der Ven M, Tchetverikov I, Kok MR, et al. Modification of a sonographic enthesitis score to differentiate between psoriatic arthritis and young healthy volunteers. Scand J Rheumatol. 2018;47(4):291–4.CrossRefPubMed
9.
go back to reference Michelsen B, Diamantopoulos AP, Soldal DM, Hammer HB, Kavanaugh A, Haugeberg G. Achilles enthesitis defined by ultrasound is not associated with clinical enthesitis in patients with psoriatic arthritis. RMD Open. 2017;3(2):e000486.CrossRefPubMedPubMedCentral Michelsen B, Diamantopoulos AP, Soldal DM, Hammer HB, Kavanaugh A, Haugeberg G. Achilles enthesitis defined by ultrasound is not associated with clinical enthesitis in patients with psoriatic arthritis. RMD Open. 2017;3(2):e000486.CrossRefPubMedPubMedCentral
10.
go back to reference Dattola A, Altobelli S, Marsico S, Plastina D, Nistico SP, Cavallo A, et al. Hypodermal adipose tissue sonoelastography for monitoring treatment response in patients with plaque psoriasis. Photomed Laser Surg. 2017;35(9):484–91.CrossRefPubMed Dattola A, Altobelli S, Marsico S, Plastina D, Nistico SP, Cavallo A, et al. Hypodermal adipose tissue sonoelastography for monitoring treatment response in patients with plaque psoriasis. Photomed Laser Surg. 2017;35(9):484–91.CrossRefPubMed
11.
go back to reference Taljanovic MS, Gimber LH, Becker GW, Latt LD, Klauser AS, Melville DM, et al. Shear-wave elastography: basic physics and musculoskeletal applications. Radiographics : Rev Publ Radiol Soc North Am, Inc. 2017;37(3):855–70.CrossRef Taljanovic MS, Gimber LH, Becker GW, Latt LD, Klauser AS, Melville DM, et al. Shear-wave elastography: basic physics and musculoskeletal applications. Radiographics : Rev Publ Radiol Soc North Am, Inc. 2017;37(3):855–70.CrossRef
12.
go back to reference Heales LJ, Badya R, Ziegenfuss B, Hug F, Coombes JS, van den Hoorn W, et al. Shear-wave velocity of the patellar tendon and quadriceps muscle is increased immediately after maximal eccentric exercise. Eur J Appl Physiol. 2018;118(8):1715–24.CrossRefPubMed Heales LJ, Badya R, Ziegenfuss B, Hug F, Coombes JS, van den Hoorn W, et al. Shear-wave velocity of the patellar tendon and quadriceps muscle is increased immediately after maximal eccentric exercise. Eur J Appl Physiol. 2018;118(8):1715–24.CrossRefPubMed
13.
go back to reference Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155–63.CrossRefPubMedPubMedCentral Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155–63.CrossRefPubMedPubMedCentral
14.
go back to reference Konar S, Bolam SM, Coleman B, Dalbeth N, McGlashan SR, Leung S, et al. Changes in physiological tendon substrate stiffness have moderate effects on tendon-derived cell growth and immune cell activation. Front Bioeng Biotechnol. 2022;10:800748.CrossRefPubMedPubMedCentral Konar S, Bolam SM, Coleman B, Dalbeth N, McGlashan SR, Leung S, et al. Changes in physiological tendon substrate stiffness have moderate effects on tendon-derived cell growth and immune cell activation. Front Bioeng Biotechnol. 2022;10:800748.CrossRefPubMedPubMedCentral
15.
go back to reference De Zordo T, Chhem R, Smekal V, Feuchtner G, Reindl M, Fink C, et al. Real-time sonoelastography: findings in patients with symptomatic achilles tendons and comparison to healthy volunteers. Ultraschall Med. 2010;31(4):394–400.CrossRefPubMed De Zordo T, Chhem R, Smekal V, Feuchtner G, Reindl M, Fink C, et al. Real-time sonoelastography: findings in patients with symptomatic achilles tendons and comparison to healthy volunteers. Ultraschall Med. 2010;31(4):394–400.CrossRefPubMed
16.
go back to reference Moon JH, Hwang JY, Park JS, Koh SH, Park SY. Impact of region of interest (ROI) size on the diagnostic performance of shear wave elastography in differentiating solid breast lesions. Acta Radiol. 2018;59(6):657–63.CrossRefPubMed Moon JH, Hwang JY, Park JS, Koh SH, Park SY. Impact of region of interest (ROI) size on the diagnostic performance of shear wave elastography in differentiating solid breast lesions. Acta Radiol. 2018;59(6):657–63.CrossRefPubMed
17.
go back to reference Prado-Costa R, Rebelo J, Monteiro-Barroso J, Preto AS. Ultrasound elastography: compression elastography and shear-wave elastography in the assessment of tendon injury. Insights Imaging. 2018;9(5):791–814.CrossRefPubMedPubMedCentral Prado-Costa R, Rebelo J, Monteiro-Barroso J, Preto AS. Ultrasound elastography: compression elastography and shear-wave elastography in the assessment of tendon injury. Insights Imaging. 2018;9(5):791–814.CrossRefPubMedPubMedCentral
18.
go back to reference Bianchi S, Martinoli C. Ultrasound of the musculoskeletal system. Springer Science & Business Media; 2007. Bianchi S, Martinoli C. Ultrasound of the musculoskeletal system. Springer Science & Business Media; 2007.
19.
go back to reference Xu J, Hug F, Fu SN. Stiffness of individual quadriceps muscle assessed using ultrasound shear wave elastography during passive stretching. J Sport Health Sci. 2018;7(2):245–9.CrossRefPubMed Xu J, Hug F, Fu SN. Stiffness of individual quadriceps muscle assessed using ultrasound shear wave elastography during passive stretching. J Sport Health Sci. 2018;7(2):245–9.CrossRefPubMed
20.
go back to reference Innocenti B, Galbusera F, editors. Human Orthopaedic Biomechanics: Fundamentals, Devices and Applications. Academic Press; 2022. Innocenti B, Galbusera F, editors. Human Orthopaedic Biomechanics: Fundamentals, Devices and Applications. Academic Press; 2022.
21.
go back to reference Bulum A, Ivanac G, Divjak E, BiondićŠpoljar I, DžoićDominković M, Bojanić K, et al. Elastic modulus and elasticity ratio of malignant breast lesions with shear wave ultrasound elastography: variations with different region of interest and lesion size. Diagnostics. 2021;11(6):1015.CrossRefPubMedPubMedCentral Bulum A, Ivanac G, Divjak E, BiondićŠpoljar I, DžoićDominković M, Bojanić K, et al. Elastic modulus and elasticity ratio of malignant breast lesions with shear wave ultrasound elastography: variations with different region of interest and lesion size. Diagnostics. 2021;11(6):1015.CrossRefPubMedPubMedCentral
22.
go back to reference Gennisson J-L, Deffieux T, Macé E, Montaldo G, Fink M, Tanter M. Viscoelastic and anisotropic mechanical properties of in vivo muscle tissue assessed by supersonic shear imaging. Ultrasound Med Biol. 2010;36(5):789–801.CrossRefPubMed Gennisson J-L, Deffieux T, Macé E, Montaldo G, Fink M, Tanter M. Viscoelastic and anisotropic mechanical properties of in vivo muscle tissue assessed by supersonic shear imaging. Ultrasound Med Biol. 2010;36(5):789–801.CrossRefPubMed
23.
go back to reference Wang X, Zhu J, Liu Y, Li W, Chen S, Zhang H. Assessment of ultrasound shear wave elastography: An animal ex-vivo study. J Appl Clin Med Phys. 2023;24(4). Wang X, Zhu J, Liu Y, Li W, Chen S, Zhang H. Assessment of ultrasound shear wave elastography: An animal ex-vivo study. J Appl Clin Med Phys. 2023;24(4).
24.
go back to reference Cortez CD, Hermitte L, Ramain A, Mesmann C, Lefort T, Pialat J. Ultrasound shear wave velocity in skeletal muscle: a reproducibility study. Diagn Interv Imaging. 2016;97(1):71–9.CrossRefPubMed Cortez CD, Hermitte L, Ramain A, Mesmann C, Lefort T, Pialat J. Ultrasound shear wave velocity in skeletal muscle: a reproducibility study. Diagn Interv Imaging. 2016;97(1):71–9.CrossRefPubMed
25.
go back to reference Kot BC, Zhang ZJ, Lee AW, Leung VY, Fu SN. Elastic modulus of muscle and tendon with shear wave ultrasound elastography: variations with different technical settings. PLoS ONE. 2012;7(8). Kot BC, Zhang ZJ, Lee AW, Leung VY, Fu SN. Elastic modulus of muscle and tendon with shear wave ultrasound elastography: variations with different technical settings. PLoS ONE. 2012;7(8).
26.
go back to reference Leong SS, Jalalonmuhali M, Md Shah MN, Ng KH, Vijayananthan A, Hisham R, et al. Ultrasound shear wave elastography for the evaluation of renal pathological changes in adult patients. Br J Radiol. 2023;96(1144):20220288.CrossRefPubMed Leong SS, Jalalonmuhali M, Md Shah MN, Ng KH, Vijayananthan A, Hisham R, et al. Ultrasound shear wave elastography for the evaluation of renal pathological changes in adult patients. Br J Radiol. 2023;96(1144):20220288.CrossRefPubMed
27.
go back to reference Lee SM, Kim M-J, Yoon JH, Hong W, Ha HI, Lee K, et al. Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis. Ultrasonography. 2020;39(3):288.CrossRefPubMedPubMedCentral Lee SM, Kim M-J, Yoon JH, Hong W, Ha HI, Lee K, et al. Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis. Ultrasonography. 2020;39(3):288.CrossRefPubMedPubMedCentral
Metadata
Title
2D shear wave elastography for the assessment of quadriceps entheses—a methodological study
Authors
Sook Sam Leong
Jeannie Hsiu Ding Wong
Faizatul Izza Rozalli
Fariz Yahya
Ying Chew Tee
Lyana Shahirah Mohamad Yamin
Mazuin Mohd Razalli
Hazlyna Baharuddin
Publication date
18-08-2023
Publisher
Springer Berlin Heidelberg
Published in
Skeletal Radiology / Issue 3/2024
Print ISSN: 0364-2348
Electronic ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-023-04425-1

Other articles of this Issue 3/2024

Skeletal Radiology 3/2024 Go to the issue