Current applications of advanced cross-sectional imaging techniques in evaluating the painful arthroplasty

Author: Carolyn M. Sofka

Published in: Skeletal Radiology | Issue 3/2007

Login to get access

Abstract

Patients with a painful arthroplasty can present a clinical diagnostic dilemma. Aspirates are often negative for infection and alignment of the prosthesis on conventional radiographs is usually satisfactory. These patients can have a myriad of soft tissue as well as osseous pathologies, which may be clinically unsuspected or radiographically occult. The ability of advanced cross-sectional imaging to diagnose osseous and soft tissue injuries has been well documented, but applications to arthroplasty imaging are often limited by regional metallic artifacts. Adjustment of standard imaging parameters can make CT and MR imaging useful adjuncts in imaging the painful arthroplasty, especially in the setting of normal radiographs. Ultrasound can be used to evaluate the periprosthetic soft tissues and provide a real-time method of evaluating the dynamic relationship of the periprosthetic soft tissues to the arthroplasty components, and it also can be used as a guide for diagnostic and therapeutic interventions.
Literature
1.
go back to reference Gould ES, Potter HG, Bober SE. Role of routine percutaneous aspirations prior to prosthesis revision. Skeletal Radiol 1990;19(6):427–30.PubMedCrossRef Gould ES, Potter HG, Bober SE. Role of routine percutaneous aspirations prior to prosthesis revision. Skeletal Radiol 1990;19(6):427–30.PubMedCrossRef
2.
go back to reference Tate D Jr, Sculco TP. Advances in total hip arthroplasty. Am J Orthop 1998;27(4):274–82.PubMed Tate D Jr, Sculco TP. Advances in total hip arthroplasty. Am J Orthop 1998;27(4):274–82.PubMed
3.
go back to reference White LM, Buckwalter KA. Technical considerations: CT and MR imaging in the postoperative orthopedic patient. Sem Musculoskel Radiol 2002;6(1):5–17.CrossRef White LM, Buckwalter KA. Technical considerations: CT and MR imaging in the postoperative orthopedic patient. Sem Musculoskel Radiol 2002;6(1):5–17.CrossRef
4.
go back to reference Young Dr, Robb RA, Rock MG, Chao EY. Analysis of periprosthetic tissue formation around a porous titanium endoprosthesis using CT-based spatial reconstruction. J Comput Assist Tomogr 1994;18(3):461–8.PubMedCrossRef Young Dr, Robb RA, Rock MG, Chao EY. Analysis of periprosthetic tissue formation around a porous titanium endoprosthesis using CT-based spatial reconstruction. J Comput Assist Tomogr 1994;18(3):461–8.PubMedCrossRef
5.
go back to reference Fiala TG, Novelline RA, Yaremchuk MJ. Comparison of CT imaging artifacts from craniomaxillofacial internal fixation devices. Plast Reconstr Surg 1993;92(7):1227–32.PubMed Fiala TG, Novelline RA, Yaremchuk MJ. Comparison of CT imaging artifacts from craniomaxillofacial internal fixation devices. Plast Reconstr Surg 1993;92(7):1227–32.PubMed
6.
go back to reference Zhao S, Robertson DD, Wang G, Whiting B, Bae KT. X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses. IEEE Trans Medical Imag 2000;19(12):1238–47.CrossRef Zhao S, Robertson DD, Wang G, Whiting B, Bae KT. X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses. IEEE Trans Medical Imag 2000;19(12):1238–47.CrossRef
7.
go back to reference Mahnken AH, Raupach R, Wildberger JE, Jung B, Heussen N, Flohr TG, et al. A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement. Invest Radiol 2003;38(12):769–75.PubMedCrossRef Mahnken AH, Raupach R, Wildberger JE, Jung B, Heussen N, Flohr TG, et al. A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement. Invest Radiol 2003;38(12):769–75.PubMedCrossRef
8.
go back to reference Buckwalter KA, Parr JA, Choplin RH, Capello WN. Multichannel CT imaging of orthopedic hardware and implants. Semin Musculoskel Radiol 2006;10(1):86–97.CrossRef Buckwalter KA, Parr JA, Choplin RH, Capello WN. Multichannel CT imaging of orthopedic hardware and implants. Semin Musculoskel Radiol 2006;10(1):86–97.CrossRef
9.
go back to reference Haramati N, Staron RB, Mazel-Sperling K, Freeman K, Nickoloff EL, Barax C, et al. CT scans through metal: scanning technique versus hardware composition. Comput Med Imag Graph 1994;18:429–34.CrossRef Haramati N, Staron RB, Mazel-Sperling K, Freeman K, Nickoloff EL, Barax C, et al. CT scans through metal: scanning technique versus hardware composition. Comput Med Imag Graph 1994;18:429–34.CrossRef
10.
go back to reference Van der Schaaf I, van Leeuwen M, Vlassenbroek A, Velthuis B. Minimizing clip artifacts in multi CT angiography of clipped patients. Am J Neuroradiol 2006;27:60–6.PubMed Van der Schaaf I, van Leeuwen M, Vlassenbroek A, Velthuis B. Minimizing clip artifacts in multi CT angiography of clipped patients. Am J Neuroradiol 2006;27:60–6.PubMed
11.
go back to reference Flohr T, Stierstorfer K, Bruder H, Simon J, Polacin A, Schaller S. Image reconstruction and image quality evaluation for a 16-slice CT scanner. Med Phys 2003;30(5):832–45.PubMedCrossRef Flohr T, Stierstorfer K, Bruder H, Simon J, Polacin A, Schaller S. Image reconstruction and image quality evaluation for a 16-slice CT scanner. Med Phys 2003;30(5):832–45.PubMedCrossRef
12.
go back to reference Dalal T, Kalra MK, Rizzo SMR, Schmidt B, Suess C, Flohr T, et al. Metallic prosthesis: technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients. Radiology 2005;236:671–5.PubMed Dalal T, Kalra MK, Rizzo SMR, Schmidt B, Suess C, Flohr T, et al. Metallic prosthesis: technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients. Radiology 2005;236:671–5.PubMed
13.
go back to reference Link TM, Berning W, Scherf S, Joosten U, Joist A, Engelke K, et al. CT of metal implants: reduction of artifacts using an extended CT scale technique. J Comput Assist Tomogr 2000;24(1):165–72.PubMedCrossRef Link TM, Berning W, Scherf S, Joosten U, Joist A, Engelke K, et al. CT of metal implants: reduction of artifacts using an extended CT scale technique. J Comput Assist Tomogr 2000;24(1):165–72.PubMedCrossRef
14.
go back to reference Fishman EK, Magid D, Robertson DD, Brooker AF, Weiss P, Siegelman SS. Metallic hip implants: CT with multiplanar reconstruction. Radiology 1986;160:675–81.PubMed Fishman EK, Magid D, Robertson DD, Brooker AF, Weiss P, Siegelman SS. Metallic hip implants: CT with multiplanar reconstruction. Radiology 1986;160:675–81.PubMed
15.
go back to reference Claus AM, Totterman SM, Sychterz CJ, Tamez-Pena JG, Looney RJ, Engh CA. Computed tomography to assess pelvic lysis after total hip replacement. Clin Orthop Rel Research 2004;422:167–74.CrossRef Claus AM, Totterman SM, Sychterz CJ, Tamez-Pena JG, Looney RJ, Engh CA. Computed tomography to assess pelvic lysis after total hip replacement. Clin Orthop Rel Research 2004;422:167–74.CrossRef
16.
go back to reference Yian EH, Werner CML, Nyffeler RW, Pfirrmann CW, Ramappa A, Sukthankar A, et al. Radiographic and computed tomography analysis of cemented pegged polyethylene glenoid components in total shoulder replacement. J Bone Joint Surg Am 2005;87-A(9):1928–36.CrossRef Yian EH, Werner CML, Nyffeler RW, Pfirrmann CW, Ramappa A, Sukthankar A, et al. Radiographic and computed tomography analysis of cemented pegged polyethylene glenoid components in total shoulder replacement. J Bone Joint Surg Am 2005;87-A(9):1928–36.CrossRef
17.
go back to reference Nishii T, Sugano N, Miki H, Koyama T, Yoshikawa H. Multidetector-CT evaluation of bone substitutes remodeling after revision hip surgery. Clin Orthop Rel Research 2006;442:158–64.CrossRef Nishii T, Sugano N, Miki H, Koyama T, Yoshikawa H. Multidetector-CT evaluation of bone substitutes remodeling after revision hip surgery. Clin Orthop Rel Research 2006;442:158–64.CrossRef
18.
go back to reference Math KR, Zaidi SF, Petchprapa C, Harwin SF. Imaging of total knee arthroplasty. Semin Musculoskel Radiol 2006;10(1):47–63.CrossRef Math KR, Zaidi SF, Petchprapa C, Harwin SF. Imaging of total knee arthroplasty. Semin Musculoskel Radiol 2006;10(1):47–63.CrossRef
19.
go back to reference Sofka CM, Potter HG. MR imaging of joint arthroplasty. Sem Musculoskel Radiol 2002;6(1):79–85.CrossRef Sofka CM, Potter HG. MR imaging of joint arthroplasty. Sem Musculoskel Radiol 2002;6(1):79–85.CrossRef
20.
go back to reference Olscamp AJ, Tao SS, Savolaine ER, Ebraheim NA. Postoperative magnetic resonance imaging evaluation of Pipkin fractures fixated with titanium implants: a report of two cases. Am J Orthoped 1997;26(4):294–7. Olscamp AJ, Tao SS, Savolaine ER, Ebraheim NA. Postoperative magnetic resonance imaging evaluation of Pipkin fractures fixated with titanium implants: a report of two cases. Am J Orthoped 1997;26(4):294–7.
21.
go back to reference Henk CB, Brodner W, Grampp S, Breitenscher M, Thurnher M, Mostbeck GH, et al. The postoperative spine. Top Magn Reson Imag 1999;10:247–64. Henk CB, Brodner W, Grampp S, Breitenscher M, Thurnher M, Mostbeck GH, et al. The postoperative spine. Top Magn Reson Imag 1999;10:247–64.
22.
go back to reference Mueller PR, Stark DD, Simeone JF, Saini S, Butch RS, Edelman RR, et al. MR-guided aspiration biopsy: needle design and clinical trials. Radiology 1986;161:605–9.PubMed Mueller PR, Stark DD, Simeone JF, Saini S, Butch RS, Edelman RR, et al. MR-guided aspiration biopsy: needle design and clinical trials. Radiology 1986;161:605–9.PubMed
23.
go back to reference White LM, Kim JK, Mehta M, Merchant N, Schweitzer ME, Morrison WB, et al. Complications of total hip arthroplasty: MR imaging-initial experience. Radiology 2000;215:254–62.PubMed White LM, Kim JK, Mehta M, Merchant N, Schweitzer ME, Morrison WB, et al. Complications of total hip arthroplasty: MR imaging-initial experience. Radiology 2000;215:254–62.PubMed
24.
go back to reference Frazzini VI, Kagetsu NJ, Johnson CE, Destian S. Internally stabilized spine: optimal choice of frequency-encoding gradient direction during MR imaging minimizes susceptibility artifact from titanium vertebral body screws. Radiology 1997;204:268–72.PubMed Frazzini VI, Kagetsu NJ, Johnson CE, Destian S. Internally stabilized spine: optimal choice of frequency-encoding gradient direction during MR imaging minimizes susceptibility artifact from titanium vertebral body screws. Radiology 1997;204:268–72.PubMed
25.
go back to reference Guermazi A, Miaux Y, Zaim S, Peterfy CG, White D, Genant HK. Metallic artifacts in MR imaging: effects of main field orientation and strength. Clin Radiol 2003;58:322–8.PubMedCrossRef Guermazi A, Miaux Y, Zaim S, Peterfy CG, White D, Genant HK. Metallic artifacts in MR imaging: effects of main field orientation and strength. Clin Radiol 2003;58:322–8.PubMedCrossRef
26.
go back to reference Venook RD, Matter NI, Ramachandran M, Ungersma SE, Gold GE, Giori NJ, et al. Prepolarized magnetic resonance imaging around metal orthopedic implants. Mag Res Med 2006;56:177–86.CrossRef Venook RD, Matter NI, Ramachandran M, Ungersma SE, Gold GE, Giori NJ, et al. Prepolarized magnetic resonance imaging around metal orthopedic implants. Mag Res Med 2006;56:177–86.CrossRef
27.
go back to reference Tartaglino LM, Flanders AE, Vinitski S, Friedman DP. Metallic artifacts on MR images of the postoperative spine: reduction with fast spin-echo techniques. Radiology 1994;190:565–9.PubMed Tartaglino LM, Flanders AE, Vinitski S, Friedman DP. Metallic artifacts on MR images of the postoperative spine: reduction with fast spin-echo techniques. Radiology 1994;190:565–9.PubMed
28.
go back to reference Potter HG, Foo LF. Magnetic resonance imaging of joint arthroplasty. Orthop Clin NA 2006;37:361–73.CrossRef Potter HG, Foo LF. Magnetic resonance imaging of joint arthroplasty. Orthop Clin NA 2006;37:361–73.CrossRef
29.
go back to reference Naraghi AM, White LM. Magnetic resonance imaging of joint replacements. Semin Musculoskel Radiol 2006;10(1):98–106.CrossRef Naraghi AM, White LM. Magnetic resonance imaging of joint replacements. Semin Musculoskel Radiol 2006;10(1):98–106.CrossRef
30.
go back to reference Hilfiker P, Zanetti M, Debatin JF, McKinnon G, Hodler J. Fast spin-echo inversion-recovery imaging versus fast T2-weighted spin-echo imaging in bone marrow abnormalities. Invest Radiol 1995;30:110–4.PubMedCrossRef Hilfiker P, Zanetti M, Debatin JF, McKinnon G, Hodler J. Fast spin-echo inversion-recovery imaging versus fast T2-weighted spin-echo imaging in bone marrow abnormalities. Invest Radiol 1995;30:110–4.PubMedCrossRef
31.
go back to reference Hendrick RE. Basic physics of MR imaging: an introduction. Radiographics 1994;17:829–46. Hendrick RE. Basic physics of MR imaging: an introduction. Radiographics 1994;17:829–46.
32.
go back to reference Taber KH, Herrick RC, Weathers SW, Kumar AJ, Schomer DF, Hayman LA. Pitfalls and artifacts encountered in clinical MR imaging of the spine. Radiographics 1998;18:1499–521.PubMed Taber KH, Herrick RC, Weathers SW, Kumar AJ, Schomer DF, Hayman LA. Pitfalls and artifacts encountered in clinical MR imaging of the spine. Radiographics 1998;18:1499–521.PubMed
33.
go back to reference Cook SM, Pellicci PM, Potter HG. Use of magnetic resonance imaging in the diagnosis of an occult fracture of the femoral component after total hip arthroplasty. J Bone Joint Surg Am 2004;86-A(1):149–53.PubMed Cook SM, Pellicci PM, Potter HG. Use of magnetic resonance imaging in the diagnosis of an occult fracture of the femoral component after total hip arthroplasty. J Bone Joint Surg Am 2004;86-A(1):149–53.PubMed
34.
go back to reference Sperling JW, Potter HG, Craig EV, Flatow E, Warren RF. MRI of the painful shoulder arthroplasty. J Shoulder Elbow Surg 2002;11:315–21.PubMedCrossRef Sperling JW, Potter HG, Craig EV, Flatow E, Warren RF. MRI of the painful shoulder arthroplasty. J Shoulder Elbow Surg 2002;11:315–21.PubMedCrossRef
35.
go back to reference Sofka CM, Potter HG, Figgie M, Laskin R. Magnetic resonance imaging of total knee arthroplasty. Clin Orthop Relat Res 2003;406:129–35.PubMedCrossRef Sofka CM, Potter HG, Figgie M, Laskin R. Magnetic resonance imaging of total knee arthroplasty. Clin Orthop Relat Res 2003;406:129–35.PubMedCrossRef
36.
go back to reference Potter HG, Nestor BJ, Sofka CM, Ho ST, Peters LE, Salvati E. Magnetic resonance imaging after total hip arthroplasty: evaluation of periprosthetic soft tissue. J Bone Joint Surg Am 2004;86-A(9):1947–54.PubMed Potter HG, Nestor BJ, Sofka CM, Ho ST, Peters LE, Salvati E. Magnetic resonance imaging after total hip arthroplasty: evaluation of periprosthetic soft tissue. J Bone Joint Surg Am 2004;86-A(9):1947–54.PubMed
37.
go back to reference Twain A, Ryan M, O’Connell M, Powell T, O’Byrne J, Eustace S. MRI of failed total hip replacement caused by abductor muscle avulsion. AJR Am J Roentgenol 2003;181:1547–50. Twain A, Ryan M, O’Connell M, Powell T, O’Byrne J, Eustace S. MRI of failed total hip replacement caused by abductor muscle avulsion. AJR Am J Roentgenol 2003;181:1547–50.
38.
go back to reference Pfirrmann CWA, Notzli HP, Dora C, Hodler J, Zanetti M. Abductor tendons and muscles assessed at MR imaging after total hip arthroplasty in asymptomatic and symptomatic patients. Radiology 2005;235:969–76.PubMed Pfirrmann CWA, Notzli HP, Dora C, Hodler J, Zanetti M. Abductor tendons and muscles assessed at MR imaging after total hip arthroplasty in asymptomatic and symptomatic patients. Radiology 2005;235:969–76.PubMed
39.
go back to reference Weiland DE, Walde TA, Leung SB, Sychterz CJ, Ho S, Engh CA, et al. Magnetic resonance imaging in the evaluation if periprosthetic acetabular osteolysis: a cadaveric study. J Orthop Research 2005;23:713–9.CrossRef Weiland DE, Walde TA, Leung SB, Sychterz CJ, Ho S, Engh CA, et al. Magnetic resonance imaging in the evaluation if periprosthetic acetabular osteolysis: a cadaveric study. J Orthop Research 2005;23:713–9.CrossRef
40.
go back to reference Sofka CM, Adler RS. Sonographic evaluation of shoulder arthroplasty. AJR Am J Roentgenol 2003;180(4):1117–20.PubMed Sofka CM, Adler RS. Sonographic evaluation of shoulder arthroplasty. AJR Am J Roentgenol 2003;180(4):1117–20.PubMed
41.
go back to reference Cuomo F, Checroun A. Avoiding pitfalls and complications in total shoulder arthroplasty. Ortho Clin North Am 1998;29:507–18.CrossRef Cuomo F, Checroun A. Avoiding pitfalls and complications in total shoulder arthroplasty. Ortho Clin North Am 1998;29:507–18.CrossRef
42.
go back to reference Jacobson JA, Lax MJ. Musculoskeletal sonography of the postoperative orthopedic patient. Sem Musculoskel Radiol 2002;6(1):67–77.CrossRef Jacobson JA, Lax MJ. Musculoskeletal sonography of the postoperative orthopedic patient. Sem Musculoskel Radiol 2002;6(1):67–77.CrossRef
43.
go back to reference Wank R, Miller TT, Shapiro JF. Sonographically guided injection of anesthetic for iliopsoas tendinopathy after total hip arthroplasty. J Clin Ultrasound 2004;32(7):354–7.PubMedCrossRef Wank R, Miller TT, Shapiro JF. Sonographically guided injection of anesthetic for iliopsoas tendinopathy after total hip arthroplasty. J Clin Ultrasound 2004;32(7):354–7.PubMedCrossRef
44.
go back to reference Rezig R, Copercini M, Montet X, Martinoli C, Bianchi S. Ultrasound diagnosis of anterior iliopsoas impingement in total hip replacement. Skeletal Radiol 2004;33:112–6.PubMedCrossRef Rezig R, Copercini M, Montet X, Martinoli C, Bianchi S. Ultrasound diagnosis of anterior iliopsoas impingement in total hip replacement. Skeletal Radiol 2004;33:112–6.PubMedCrossRef
45.
go back to reference Adler RS, Buly R, Ambrose R, Sculco T. Diagnostic and therapeutic use of sonography-guided iliopsoas peritendinous injections. AJR Am J Roentgenol 2005;185:940–3.PubMedCrossRef Adler RS, Buly R, Ambrose R, Sculco T. Diagnostic and therapeutic use of sonography-guided iliopsoas peritendinous injections. AJR Am J Roentgenol 2005;185:940–3.PubMedCrossRef
46.
go back to reference Blankenbaker DG, DeSmet AA, Keene JS. Sonography of the iliopsoas tendon and injection of the iliopsoas bursa for diagnosis and management of the painful snapping hip. Skeletal Radiol 2006;35:565–71.PubMedCrossRef Blankenbaker DG, DeSmet AA, Keene JS. Sonography of the iliopsoas tendon and injection of the iliopsoas bursa for diagnosis and management of the painful snapping hip. Skeletal Radiol 2006;35:565–71.PubMedCrossRef
47.
go back to reference van Holsbeeck MT, Eyler WR, Sherman LS, Lombardi TJ, Mezger E, Verner JJ, et al. Detection of infection in loosened hip prostheses: efficacy of sonography. Am J Roentgenol 1994;163(2):381–4. van Holsbeeck MT, Eyler WR, Sherman LS, Lombardi TJ, Mezger E, Verner JJ, et al. Detection of infection in loosened hip prostheses: efficacy of sonography. Am J Roentgenol 1994;163(2):381–4.
48.
go back to reference Fessell DP, Jacobson JA, Craig J, Habra G, Prasad A, Radcliff A, et al. Using sonography to reveal and aspirate joint effusions. Am J Roentgenol 2000;174(5):1353–62. Fessell DP, Jacobson JA, Craig J, Habra G, Prasad A, Radcliff A, et al. Using sonography to reveal and aspirate joint effusions. Am J Roentgenol 2000;174(5):1353–62.
49.
go back to reference Weybright PN, Jacobson JA, Murry KH, Lin J, Fessell DP, Jamador DA, et al. Limited effectiveness of sonography in revealing hip joint effusion: preliminary results in 21 adult patients, with native and post operative hips. AJR Am J Roentgenol 2003;181:215–8.PubMed Weybright PN, Jacobson JA, Murry KH, Lin J, Fessell DP, Jamador DA, et al. Limited effectiveness of sonography in revealing hip joint effusion: preliminary results in 21 adult patients, with native and post operative hips. AJR Am J Roentgenol 2003;181:215–8.PubMed
50.
go back to reference Sofka CM, Adler RS, Laskin R. Sonography of polyethylene liners used in total knee arthroplasty. AJR Am J Roentgenol 2003;180(5):1437–41.PubMed Sofka CM, Adler RS, Laskin R. Sonography of polyethylene liners used in total knee arthroplasty. AJR Am J Roentgenol 2003;180(5):1437–41.PubMed
Metadata
Title
Current applications of advanced cross-sectional imaging techniques in evaluating the painful arthroplasty
Author
Carolyn M. Sofka
Publication date
01-03-2007
Publisher
Springer-Verlag
Published in
Skeletal Radiology / Issue 3/2007
Print ISSN: 0364-2348
Electronic ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-006-0226-x

Other articles of this Issue 3/2007

Skeletal Radiology 3/2007 Go to the issue

Browser's Notes

Browser’s Notes