Abstract

A central venous catheter is typically made of silicone rubber or polyurethane and inserted into a large central vein to provide prolonged and direct access to central venous circulation. These catheters provide a safe and effective method to administer intravenous medications, nutritional supplements, fluids and blood products. However, a myriad of complications is associated with central venous catheters, including, but not limited to, mechanical malfunction or fracture, kinking, erroneous placement, line infection, fibrin sheath formation and venous thrombosis. Following clinical and radiographic evaluation, contrast-enhanced line studies constitute the next best diagnostic tool to assess the functionality of central venous catheters. However, there is a lack of standardization in the literature outlining how these studies should be performed. In addition, the interpretation of these studies can be problematic for general pediatric radiologists, many of whom are often not familiar with placement or manipulation of these catheters. In this pictorial review, we highlight the challenges associated with performing and interpreting fluoroscopically guided contrast injection studies, using case studies drawn from a large tertiary children’s hospital database for illustration. Revealing these challenges and understanding their causative mechanisms can improve the performance of these line studies.
Appendix
Available only for authorised users
Literature
1.
go back to reference Jaffray J, Bauman M, Massicotte P (2017) The impact of central venous catheters on pediatric venous thromboembolism. Front Pediatr 5:5CrossRef Jaffray J, Bauman M, Massicotte P (2017) The impact of central venous catheters on pediatric venous thromboembolism. Front Pediatr 5:5CrossRef
2.
go back to reference Racadio JM, Doellman DA, Johnson ND et al (2001) Pediatric peripherally inserted central catheters: complication rates related to catheter tip location. Pediatrics 107:e28–e28CrossRef Racadio JM, Doellman DA, Johnson ND et al (2001) Pediatric peripherally inserted central catheters: complication rates related to catheter tip location. Pediatrics 107:e28–e28CrossRef
3.
go back to reference de Jonge RC, Polderman KH, Gemke RJ (2005) Central venous catheter use in the pediatric patient: mechanical and infectious complications. Pediatr Crit Care Med 6:329–339CrossRef de Jonge RC, Polderman KH, Gemke RJ (2005) Central venous catheter use in the pediatric patient: mechanical and infectious complications. Pediatr Crit Care Med 6:329–339CrossRef
4.
go back to reference Kim FM, Burrows PE, Hoffer FA, Chung T (1996) Interpreting the results of pediatric central venous catheter studies. Radiographics 16:747–754CrossRef Kim FM, Burrows PE, Hoffer FA, Chung T (1996) Interpreting the results of pediatric central venous catheter studies. Radiographics 16:747–754CrossRef
5.
go back to reference Boardman P, Hughes JP (1998) Radiological evaluation and management of malfunctioning central venous catheters. Clin Radiol 53:10–16CrossRef Boardman P, Hughes JP (1998) Radiological evaluation and management of malfunctioning central venous catheters. Clin Radiol 53:10–16CrossRef
6.
go back to reference Barnacle A, Arthurs OJ, Roebuck D, Hiorns MP (2008) Malfunctioning central venous catheters in children: a diagnostic approach. Pediatr Radiol 38:363–378, quiz 486–367 Barnacle A, Arthurs OJ, Roebuck D, Hiorns MP (2008) Malfunctioning central venous catheters in children: a diagnostic approach. Pediatr Radiol 38:363–378, quiz 486–367
7.
go back to reference Faintuch S, Salazar GM (2008) Malfunction of dialysis catheters: management of fibrin sheath and related problems. Tech Vasc Interv Radiol 11:195–200CrossRef Faintuch S, Salazar GM (2008) Malfunction of dialysis catheters: management of fibrin sheath and related problems. Tech Vasc Interv Radiol 11:195–200CrossRef
8.
go back to reference Knutstad K, Hager B, Hauser M (2003) Radiologic diagnosis and management of complications related to central venous access. Acta Radiol 44:508–516CrossRef Knutstad K, Hager B, Hauser M (2003) Radiologic diagnosis and management of complications related to central venous access. Acta Radiol 44:508–516CrossRef
9.
go back to reference Crain MR, Horton MG, Mewissen MW (1998) Fibrin sheaths complicating central venous catheters. AJR Am J Roentgenol 171:341–346CrossRef Crain MR, Horton MG, Mewissen MW (1998) Fibrin sheaths complicating central venous catheters. AJR Am J Roentgenol 171:341–346CrossRef
10.
go back to reference Tomaszewski M, Kosiak W, Irga N, Połczyńska K (2013) Ultrasound assessment of thrombotic complications in pediatric patients with tunneled central venous catheters. J Ultrason 13:451–459CrossRef Tomaszewski M, Kosiak W, Irga N, Połczyńska K (2013) Ultrasound assessment of thrombotic complications in pediatric patients with tunneled central venous catheters. J Ultrason 13:451–459CrossRef
11.
go back to reference Zens T, Nichol P, Leys C et al (2019) Fractured pediatric central venous catheters - Repair or replace? J Pediatr Surg 54:165–169CrossRef Zens T, Nichol P, Leys C et al (2019) Fractured pediatric central venous catheters - Repair or replace? J Pediatr Surg 54:165–169CrossRef
12.
go back to reference Cho JB, Park IY, Sung KY et al (2013) Pinch-off syndrome. J Korean Surg Soc 85:139–144CrossRef Cho JB, Park IY, Sung KY et al (2013) Pinch-off syndrome. J Korean Surg Soc 85:139–144CrossRef
13.
go back to reference Hayward WA, Haseler LJ, Kettwich LG et al (2011) Pressure generated by syringes: implications for hydrodissection and injection of dense connective tissue lesions. Scand J Rheumatol 40:379–382CrossRef Hayward WA, Haseler LJ, Kettwich LG et al (2011) Pressure generated by syringes: implications for hydrodissection and injection of dense connective tissue lesions. Scand J Rheumatol 40:379–382CrossRef
Metadata
Title
Diagnostic challenges with central venous catheter studies
Authors
Kumar K. Shashi
Michael J. Callahan
Andy Tsai
Publication date
23-04-2022
Publisher
Springer Berlin Heidelberg
Published in
Pediatric Radiology / Issue 8/2022
Print ISSN: 0301-0449
Electronic ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-022-05362-2

Other articles of this Issue 8/2022

Pediatric Radiology 8/2022 Go to the issue