Skip to main content
Top
Published in: Pediatric Radiology 1/2015

Open Access 01-01-2015 | Original Article

High-field MR imaging in pediatric congenital heart disease: Initial results

Authors: Kim-Lien Nguyen, Sarah N. Khan, John M. Moriarty, Kiyarash Mohajer, Pierangelo Renella, Gary Satou, Ihab Ayad, Swati Patel, M. Ines Boechat, J. Paul Finn

Published in: Pediatric Radiology | Issue 1/2015

Login to get access

Abstract

Background

Comprehensive assessment of pediatric congenital heart disease (CHD) at any field strength mandates evaluation of both vascular and dynamic cardiac anatomy for which diagnostic quality contrast-enhanced magnetic resonance angiography (CEMRA) and cardiac cine are crucial.

Objective

To determine whether high-resolution (HR) CEMRA and steady-state free precession (SSFP) cine can be performed reliably at 3.0 T in children with CHD and to compare the image quality to similar techniques performed at 1.5 T.

Materials and methods

Twenty-eight patients with a median age of 5 months and average weight 9.0 ± 7.8 kg with suspected or known CHD were evaluated at 3.0 T. SSFP cine (n = 86 series) and HR-CEMRA (n = 414 named vascular segments) were performed and images were scored for image quality and artifacts. The findings were compared to those of 28 patients with CHD of similar weight who were evaluated at 1.5 T.

Results

Overall image quality on HR-CEMRA was rated as excellent or good in 96% (397/414) of vascular segments at 3.0 T (k = 0.49) and in 94% (349/371) of vascular segments at 1.5 T (k = 0.36). Overall image quality of SSFP was rated excellent or good in 91% (78/86) of cine series at 3.0 T (k = 0.55) and in 81% (87/108) at 1.5 T (k = 0.47). Off-resonance artifact was common at both field strengths, varied over the cardiac cycle and was more prevalent at 3.0 T. At 3.0 T, off-resonance dark band artifact on SSFP cine was absent in 3% (3/86), mild in 69% (59/86), moderate in 27% (23/86) and severe in 1% (1/86) of images; at 1.5 T, dark band artifact was absent in 16% (17/108), mild in 69% (75/108), moderate in 12% (13/108) and severe in 3% (3/108) of cine images. The signal-to-noise ratio and contrast-to-noise ratio of both SSFP cine and HR-CEMRA images were significantly higher at 3.0 T than at 1.5 T (P < 0.001).

Conclusion

Signal-to-noise ratio and contrast-to-noise ratio of high-resolution contrast-enhanced magnetic resonance angiography and SSFP cine were higher at 3.0 T than at 1.5 T. Artifacts on SSFP cine were cardiac phase specific and more prevalent at 3.0 T such that frequency-tuning was required in one-third of exams. In neonates, high spatial resolution CEMRA was highly reliable in defining extracardiac vascular anatomy.
Literature
1.
go back to reference Hundley WG, Bluemke DA, Finn JP et al (2010) ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents. J Am Coll Cardiol 55:2614–2662PubMedCrossRef Hundley WG, Bluemke DA, Finn JP et al (2010) ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents. J Am Coll Cardiol 55:2614–2662PubMedCrossRef
2.
go back to reference Woodard PK, Bhalla S, Javidan-Nejad C et al (2008) Cardiac MRI in the management of congenital heart disease in children, adolescents, and young adults. Curr Treat Options Cardiovasc Med 10:419–424PubMedCrossRef Woodard PK, Bhalla S, Javidan-Nejad C et al (2008) Cardiac MRI in the management of congenital heart disease in children, adolescents, and young adults. Curr Treat Options Cardiovasc Med 10:419–424PubMedCrossRef
4.
go back to reference Frayne R, Goodyear BG, Dickhoff P et al (2003) Magnetic resonance imaging at 3.0 Tesla: challenges and advantages in clinical neurological imaging. Invest Radiol 38:385–402PubMed Frayne R, Goodyear BG, Dickhoff P et al (2003) Magnetic resonance imaging at 3.0 Tesla: challenges and advantages in clinical neurological imaging. Invest Radiol 38:385–402PubMed
5.
go back to reference Kuhl CK, Traber F, Schild HH (2008) Whole-body high-field-strength (3.0-T) MR Imaging in Clinical Practice. Part I. Technical considerations and clinical applications. Radiology 246:675–696PubMedCrossRef Kuhl CK, Traber F, Schild HH (2008) Whole-body high-field-strength (3.0-T) MR Imaging in Clinical Practice. Part I. Technical considerations and clinical applications. Radiology 246:675–696PubMedCrossRef
6.
go back to reference Kuhl CK, Traber F, Gieseke J et al (2008) Whole-body high-field-strength (3.0-T) MR imaging in clinical practice. Part II. Technical considerations and clinical applications. Radiology 247:16–35PubMedCrossRef Kuhl CK, Traber F, Gieseke J et al (2008) Whole-body high-field-strength (3.0-T) MR imaging in clinical practice. Part II. Technical considerations and clinical applications. Radiology 247:16–35PubMedCrossRef
7.
go back to reference Nael K, Villablanca JP, Pope WB et al (2007) Supraaortic arteries: contrast-enhanced MR angiography at 3.0 T–highly accelerated parallel acquisition for improved spatial resolution over an extended field of view. Radiology 242:600–609PubMedCrossRef Nael K, Villablanca JP, Pope WB et al (2007) Supraaortic arteries: contrast-enhanced MR angiography at 3.0 T–highly accelerated parallel acquisition for improved spatial resolution over an extended field of view. Radiology 242:600–609PubMedCrossRef
8.
go back to reference DeMarco JK, Willinek WA, Finn JP et al (2012) Current state-of-the-art 1.5 T and 3 T extracranial carotid contrast-enhanced magnetic resonance angiography. Neuroimaging Clin N Am 22:235–257PubMedCrossRef DeMarco JK, Willinek WA, Finn JP et al (2012) Current state-of-the-art 1.5 T and 3 T extracranial carotid contrast-enhanced magnetic resonance angiography. Neuroimaging Clin N Am 22:235–257PubMedCrossRef
9.
go back to reference Saleh RS, Patel S, Lee MH et al (2007) Contrast-enhanced MR angiography of the chest and abdomen with use of controlled apnea in children. Radiology 243:837–846PubMedCrossRef Saleh RS, Patel S, Lee MH et al (2007) Contrast-enhanced MR angiography of the chest and abdomen with use of controlled apnea in children. Radiology 243:837–846PubMedCrossRef
10.
go back to reference Odegard KC, DiNardo JA, Tsai-Goodman B et al (2004) Anaesthesia considerations for cardiac MRI in infants and small children. Paediatr Anaesth 14:471–476PubMedCrossRef Odegard KC, DiNardo JA, Tsai-Goodman B et al (2004) Anaesthesia considerations for cardiac MRI in infants and small children. Paediatr Anaesth 14:471–476PubMedCrossRef
11.
go back to reference Carr JC, Simonetti O, Bundy J et al (2001) Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 219:828–834PubMedCrossRef Carr JC, Simonetti O, Bundy J et al (2001) Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 219:828–834PubMedCrossRef
12.
go back to reference Young AA, Imai H, Chang CN et al (1994) Two-dimensional left ventricular deformation during systole using magnetic resonance imaging with spatial modulation of magnetization. Circulation 89:740–752PubMedCrossRef Young AA, Imai H, Chang CN et al (1994) Two-dimensional left ventricular deformation during systole using magnetic resonance imaging with spatial modulation of magnetization. Circulation 89:740–752PubMedCrossRef
13.
go back to reference Beerbaum P, Korperich H, Gieseke J et al (2003) Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding (SENSE). Circulation 108:1355–1361PubMedCrossRef Beerbaum P, Korperich H, Gieseke J et al (2003) Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding (SENSE). Circulation 108:1355–1361PubMedCrossRef
14.
go back to reference Li W, Storey P, Chen Q et al (2004) Dark flow artifacts with steady-state free precession cine MR technique: causes and implications for cardiac MR imaging. Radiology 230:569–575PubMedCrossRef Li W, Storey P, Chen Q et al (2004) Dark flow artifacts with steady-state free precession cine MR technique: causes and implications for cardiac MR imaging. Radiology 230:569–575PubMedCrossRef
15.
go back to reference Michaely HJ, Nael K, Schoenberg SO et al (2006) Analysis of cardiac function–comparison between 1.5 Tesla and 3.0 Tesla cardiac cine magnetic resonance imaging: preliminary experience. Invest Radiol 41:133–140PubMedCrossRef Michaely HJ, Nael K, Schoenberg SO et al (2006) Analysis of cardiac function–comparison between 1.5 Tesla and 3.0 Tesla cardiac cine magnetic resonance imaging: preliminary experience. Invest Radiol 41:133–140PubMedCrossRef
16.
go back to reference Krishnam MS, Tomasian A, Lohan DG et al (2008) Low-dose, time-resolved, contrast-enhanced 3D MR angiography in cardiac and vascular diseases: correlation to high spatial resolution 3D contrast-enhanced MRA. Clin Radiol 63:744–755PubMedCrossRef Krishnam MS, Tomasian A, Lohan DG et al (2008) Low-dose, time-resolved, contrast-enhanced 3D MR angiography in cardiac and vascular diseases: correlation to high spatial resolution 3D contrast-enhanced MRA. Clin Radiol 63:744–755PubMedCrossRef
17.
go back to reference Niendorf T, Sodickson DK (2006) Parallel imaging in cardiovascular MRI: methods and applications. NMR Biomed 19:325–341PubMedCrossRef Niendorf T, Sodickson DK (2006) Parallel imaging in cardiovascular MRI: methods and applications. NMR Biomed 19:325–341PubMedCrossRef
18.
go back to reference Bammer R, Schoenberg SO (2004) Current concepts and advances in clinical parallel magnetic resonance imaging. Top Magn Reson Imaging 15:129–158PubMedCrossRef Bammer R, Schoenberg SO (2004) Current concepts and advances in clinical parallel magnetic resonance imaging. Top Magn Reson Imaging 15:129–158PubMedCrossRef
19.
go back to reference Heidemann R (2006) Perspectives and limitations of parallel MR imaging at high field strengths. Neuroimaging Clin N Am 16:311–320PubMedCrossRef Heidemann R (2006) Perspectives and limitations of parallel MR imaging at high field strengths. Neuroimaging Clin N Am 16:311–320PubMedCrossRef
20.
go back to reference Feinstein AR, Cicchetti DV (1990) High agreement but low kappa: I. The problems of two paradoxes. J Clin Epidemiol 43:543–549PubMedCrossRef Feinstein AR, Cicchetti DV (1990) High agreement but low kappa: I. The problems of two paradoxes. J Clin Epidemiol 43:543–549PubMedCrossRef
21.
go back to reference Gwet KL (2008) Computing inter-rater reliability and its variance in the presence of high agreement. Br J Math Stat Psychol 61:29–48PubMedCrossRef Gwet KL (2008) Computing inter-rater reliability and its variance in the presence of high agreement. Br J Math Stat Psychol 61:29–48PubMedCrossRef
22.
go back to reference Price AN, Malik SJ, Broadhouse KM et al (2012) Neonatal cardiac MRI using prolonged balanced SSFP imaging at 3 T with active frequency stabilization. Magn Reson Med 70:776–784CrossRef Price AN, Malik SJ, Broadhouse KM et al (2012) Neonatal cardiac MRI using prolonged balanced SSFP imaging at 3 T with active frequency stabilization. Magn Reson Med 70:776–784CrossRef
23.
go back to reference Ntsinjana HN, Hughes ML, Taylor AM (2011) The role of cardiovascular magnetic resonance in pediatric congenital heart disease. J Cardiovasc Magn Reson 13:51PubMedCentralPubMedCrossRef Ntsinjana HN, Hughes ML, Taylor AM (2011) The role of cardiovascular magnetic resonance in pediatric congenital heart disease. J Cardiovasc Magn Reson 13:51PubMedCentralPubMedCrossRef
24.
go back to reference Masui T, Katayama M, Kobayashi S et al (2000) Gadolinium-enhanced MR angiography in the evaluation of congenital cardiovascular disease pre- and postoperative states in infants and children. J Magn Reson Imaging 12:1034–1042PubMedCrossRef Masui T, Katayama M, Kobayashi S et al (2000) Gadolinium-enhanced MR angiography in the evaluation of congenital cardiovascular disease pre- and postoperative states in infants and children. J Magn Reson Imaging 12:1034–1042PubMedCrossRef
25.
go back to reference Kellenberger CJ, Yoo SJ, Büchel ER (2007) Cardiovascular MR imaging in neonates and infants with congenital heart disease. Radiographics 27:5–18PubMedCrossRef Kellenberger CJ, Yoo SJ, Büchel ER (2007) Cardiovascular MR imaging in neonates and infants with congenital heart disease. Radiographics 27:5–18PubMedCrossRef
26.
go back to reference Marcotte F, Poirier N, Pressacco J et al (2009) Evaluation of adult congenital heart disease by cardiac magnetic resonance imaging. Congenit Heart Dis 4:216–230PubMedCrossRef Marcotte F, Poirier N, Pressacco J et al (2009) Evaluation of adult congenital heart disease by cardiac magnetic resonance imaging. Congenit Heart Dis 4:216–230PubMedCrossRef
27.
go back to reference Dinh HV, Alvergue J, Sayre J et al (2008) Isovolumic cardiac contraction on high-temporal-resolution cine MR images: study in heart failure patients and healthy volunteers. Radiology 248:458–465PubMedCrossRef Dinh HV, Alvergue J, Sayre J et al (2008) Isovolumic cardiac contraction on high-temporal-resolution cine MR images: study in heart failure patients and healthy volunteers. Radiology 248:458–465PubMedCrossRef
28.
go back to reference Sarikouch S, Schaeffler R, Korperich H et al (2009) Cardiovascular magnetic resonance imaging for intensive care infants: safe and effective? Pediatr Cardiol 30:146–152PubMedCrossRef Sarikouch S, Schaeffler R, Korperich H et al (2009) Cardiovascular magnetic resonance imaging for intensive care infants: safe and effective? Pediatr Cardiol 30:146–152PubMedCrossRef
29.
go back to reference Dagia C, Ditchfield M (2008) 3 T MRI in paediatrics: Challenges and clinical applications. Eur J Radiol 68:309–319PubMedCrossRef Dagia C, Ditchfield M (2008) 3 T MRI in paediatrics: Challenges and clinical applications. Eur J Radiol 68:309–319PubMedCrossRef
30.
go back to reference Kreitner KF, Kunz RP, Kalden P et al (2001) Contrast-enhanced three-dimensional MR angiography of the thoracic aorta: experiences after 118 examinations with a standard dose contrast administration and different injection protocols. Eur Radiol 11:1355–1363PubMedCrossRef Kreitner KF, Kunz RP, Kalden P et al (2001) Contrast-enhanced three-dimensional MR angiography of the thoracic aorta: experiences after 118 examinations with a standard dose contrast administration and different injection protocols. Eur Radiol 11:1355–1363PubMedCrossRef
31.
go back to reference Lee VS (2006) Cardiovascular MRI: physical principles to practical protocols. Lippincott Williams & Wilkins, Philadelphia Lee VS (2006) Cardiovascular MRI: physical principles to practical protocols. Lippincott Williams & Wilkins, Philadelphia
32.
go back to reference Naehle CP, Kaestner M, Muller A et al (2010) First-pass and steady-state MR angiography of thoracic vasculature in children and adolescents. JACC Cardiovasc Imaging 3:504–513PubMedCrossRef Naehle CP, Kaestner M, Muller A et al (2010) First-pass and steady-state MR angiography of thoracic vasculature in children and adolescents. JACC Cardiovasc Imaging 3:504–513PubMedCrossRef
33.
go back to reference Prakash A, Torres AJ, Printz BF et al (2007) Usefulness of magnetic resonance angiography in the evaluation of complex congenital heart disease in newborns and infants. Am J Cardiol 100:715–721PubMedCrossRef Prakash A, Torres AJ, Printz BF et al (2007) Usefulness of magnetic resonance angiography in the evaluation of complex congenital heart disease in newborns and infants. Am J Cardiol 100:715–721PubMedCrossRef
34.
go back to reference Willmann JK, Wildermuth S, Pfammatter T et al (2003) Aortoiliac and renal arteries: prospective intraindividual comparison of contrast-enhanced three-dimensional MR angiography and multi-detector row CT angiography. Radiology 226:798–811PubMedCrossRef Willmann JK, Wildermuth S, Pfammatter T et al (2003) Aortoiliac and renal arteries: prospective intraindividual comparison of contrast-enhanced three-dimensional MR angiography and multi-detector row CT angiography. Radiology 226:798–811PubMedCrossRef
35.
go back to reference Tyler DJ, Hudsmith LE, Petersen SE et al (2006) Cardiac cine MR-imaging at 3 T: FLASH vs SSFP. J Cardiovasc Magn Reson 8:709–715PubMedCrossRef Tyler DJ, Hudsmith LE, Petersen SE et al (2006) Cardiac cine MR-imaging at 3 T: FLASH vs SSFP. J Cardiovasc Magn Reson 8:709–715PubMedCrossRef
36.
go back to reference Gutberlet M, Noeske R, Schwinge K et al (2006) Comprehensive cardiac magnetic resonance imaging at 3.0 Tesla: feasibility and implications for clinical applications. Invest Radiol 41:154–167PubMedCrossRef Gutberlet M, Noeske R, Schwinge K et al (2006) Comprehensive cardiac magnetic resonance imaging at 3.0 Tesla: feasibility and implications for clinical applications. Invest Radiol 41:154–167PubMedCrossRef
37.
go back to reference Schar M, Kozerke S, Fischer SE et al (2004) Cardiac SSFP imaging at 3 Tesla. Magn Reson Med 51:799–806PubMedCrossRef Schar M, Kozerke S, Fischer SE et al (2004) Cardiac SSFP imaging at 3 Tesla. Magn Reson Med 51:799–806PubMedCrossRef
38.
go back to reference Leupold J, Hennig J, Scheffler K (2006) Alternating repetition time balanced steady state free precession. Magn Reson Med 55:557–565PubMedCrossRef Leupold J, Hennig J, Scheffler K (2006) Alternating repetition time balanced steady state free precession. Magn Reson Med 55:557–565PubMedCrossRef
40.
go back to reference Reeder SB, Wintersperger BJ, Dietrich O et al (2005) Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: Application with cardiac imaging and a 32-channel cardiac coil. Magn Reson Med 54:748–754PubMedCrossRef Reeder SB, Wintersperger BJ, Dietrich O et al (2005) Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: Application with cardiac imaging and a 32-channel cardiac coil. Magn Reson Med 54:748–754PubMedCrossRef
41.
go back to reference Firbank MJ, Coulthard A, Harrison RM et al (1999) A comparison of two methods for measuring the signal to noise ratio on MR images. Phys Med Biol 44:N261–264PubMedCrossRef Firbank MJ, Coulthard A, Harrison RM et al (1999) A comparison of two methods for measuring the signal to noise ratio on MR images. Phys Med Biol 44:N261–264PubMedCrossRef
Metadata
Title
High-field MR imaging in pediatric congenital heart disease: Initial results
Authors
Kim-Lien Nguyen
Sarah N. Khan
John M. Moriarty
Kiyarash Mohajer
Pierangelo Renella
Gary Satou
Ihab Ayad
Swati Patel
M. Ines Boechat
J. Paul Finn
Publication date
01-01-2015
Publisher
Springer Berlin Heidelberg
Published in
Pediatric Radiology / Issue 1/2015
Print ISSN: 0301-0449
Electronic ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-014-3093-y

Other articles of this Issue 1/2015

Pediatric Radiology 1/2015 Go to the issue

Research Forum

Why measure tumours?