Skip to main content
Top
Published in: Pediatric Radiology 4/2014

01-04-2014 | Review

Fetal magnetic resonance imaging: jumping from 1.5 to 3 tesla (preliminary experience)

Authors: Teresa Victoria, Diego Jaramillo, Timothy Paul Leslie Roberts, Deborah Zarnow, Ann Michelle Johnson, Jorge Delgado, Erika Rubesova, Arastoo Vossough

Published in: Pediatric Radiology | Issue 4/2014

Login to get access

Abstract

Several attempts have been made at imaging the fetus at 3 T as part of the continuous search for increased image signal and better anatomical delineation of the developing fetus. Until very recently, imaging of the fetus at 3 T has been disappointing, with numerous artifacts impeding image analysis. Better magnets and coils and improved technology now allow imaging of the fetus at greater magnetic strength, some hurdles in the shape of imaging artifacts notwithstanding. In this paper we present the preliminary experience of evaluating the developing fetus at 3 T and discuss several artifacts encountered and techniques to decrease them, as well as safety concerns associated with scanning the fetus at higher magnetic strength.
Literature
2.
go back to reference Stark DD, McCarthy SM, Filly RA et al (1985) Pelvimetry by magnetic resonance imaging. AJR Am J Roentgenol 144:947–950PubMedCrossRef Stark DD, McCarthy SM, Filly RA et al (1985) Pelvimetry by magnetic resonance imaging. AJR Am J Roentgenol 144:947–950PubMedCrossRef
3.
4.
go back to reference Kuo R, Panchal M, Tanenbaum L et al (2007) 3.0 Tesla imaging of the musculoskeletal system. J Magn Reson Imaging 25:245–261PubMedCrossRef Kuo R, Panchal M, Tanenbaum L et al (2007) 3.0 Tesla imaging of the musculoskeletal system. J Magn Reson Imaging 25:245–261PubMedCrossRef
5.
go back to reference Chang KJ, Kamel IR, Macura KJ et al (2008) 3.0-T MR imaging of the abdomen: comparison with 1.5 T. Radiographics 28:1983–1998PubMedCrossRef Chang KJ, Kamel IR, Macura KJ et al (2008) 3.0-T MR imaging of the abdomen: comparison with 1.5 T. Radiographics 28:1983–1998PubMedCrossRef
6.
go back to reference Barth MM, Smith MP, Pedrosa I et al (2007) Body MR imaging at 3.0 T: understanding the opportunities and challenges. Radiographics 27:1445–1462, discussion 1462–1464 Barth MM, Smith MP, Pedrosa I et al (2007) Body MR imaging at 3.0 T: understanding the opportunities and challenges. Radiographics 27:1445–1462, discussion 1462–1464
7.
go back to reference Erturk SM, Alberich-Bayarri A, Herrmann KA et al (2009) Use of 3.0-T MR imaging for evaluation of the abdomen. Radiographics 29:1547–1563PubMedCrossRef Erturk SM, Alberich-Bayarri A, Herrmann KA et al (2009) Use of 3.0-T MR imaging for evaluation of the abdomen. Radiographics 29:1547–1563PubMedCrossRef
8.
go back to reference Glockner JF, Hu HH, Stanley DW et al (2005) Parallel MR imaging: a user’s guide. Radiographics 25:1279–1297PubMedCrossRef Glockner JF, Hu HH, Stanley DW et al (2005) Parallel MR imaging: a user’s guide. Radiographics 25:1279–1297PubMedCrossRef
9.
go back to reference De Bazelaire CM, Duhamel GD, Rofsky NM et al (2004) MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. Radiology 230:652–659PubMedCrossRef De Bazelaire CM, Duhamel GD, Rofsky NM et al (2004) MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. Radiology 230:652–659PubMedCrossRef
10.
go back to reference Hedrick HL, Danzer E, Merchant A et al (2007) Liver position and lung-to-head ratio for prediction of extracorporeal membrane oxygenation and survival in isolated left congenital diaphragmatic hernia. Am J Obstet Gynecol 197:e421–e424CrossRef Hedrick HL, Danzer E, Merchant A et al (2007) Liver position and lung-to-head ratio for prediction of extracorporeal membrane oxygenation and survival in isolated left congenital diaphragmatic hernia. Am J Obstet Gynecol 197:e421–e424CrossRef
11.
go back to reference Victoria T, Bebbington MW, Danzer E et al (2012) Use of magnetic resonance imaging in prenatal prognosis of the fetus with isolated left congenital diaphragmatic hernia. Prenat Diagn 32:715–723PubMedCrossRef Victoria T, Bebbington MW, Danzer E et al (2012) Use of magnetic resonance imaging in prenatal prognosis of the fetus with isolated left congenital diaphragmatic hernia. Prenat Diagn 32:715–723PubMedCrossRef
12.
go back to reference Jani J, Cannie M, Sonigo P et al (2008) Value of prenatal magnetic resonance imaging in the prediction of postnatal outcome in fetuses with diaphragmatic hernia. Ultrasound Obstet Gynecol 32:793–799PubMedCrossRef Jani J, Cannie M, Sonigo P et al (2008) Value of prenatal magnetic resonance imaging in the prediction of postnatal outcome in fetuses with diaphragmatic hernia. Ultrasound Obstet Gynecol 32:793–799PubMedCrossRef
13.
go back to reference Victoria T, Danzer E, Adzick NS (2013) Use of ultrasound and MRI for evaluation of lung volumes in fetuses with isolated left congenital diaphragmatic hernia. Semin Pediatr Surg 22:30–36PubMedCrossRef Victoria T, Danzer E, Adzick NS (2013) Use of ultrasound and MRI for evaluation of lung volumes in fetuses with isolated left congenital diaphragmatic hernia. Semin Pediatr Surg 22:30–36PubMedCrossRef
14.
go back to reference Victoria T, Epelman M, Coleman BG et al (2013) Low-dose fetal CT in the prenatal evaluation of skeletal dysplasias and other severe skeletal abnormalities. AJR Am J Roentgenol 200:989–1000PubMedCrossRef Victoria T, Epelman M, Coleman BG et al (2013) Low-dose fetal CT in the prenatal evaluation of skeletal dysplasias and other severe skeletal abnormalities. AJR Am J Roentgenol 200:989–1000PubMedCrossRef
15.
go back to reference Zizka J, Elias P, Hodik K et al (2006) Liver, meconium, haemorrhage: the value of T1-weighted images in fetal MRI. Pediatr Radiol 36:792–801PubMedCrossRef Zizka J, Elias P, Hodik K et al (2006) Liver, meconium, haemorrhage: the value of T1-weighted images in fetal MRI. Pediatr Radiol 36:792–801PubMedCrossRef
16.
go back to reference Saguintaah M, Couture A, Veyrac C et al (2002) MRI of the fetal gastrointestinal tract. Pediatr Radiol 32:395–404PubMedCrossRef Saguintaah M, Couture A, Veyrac C et al (2002) MRI of the fetal gastrointestinal tract. Pediatr Radiol 32:395–404PubMedCrossRef
17.
go back to reference Rubesova E, Vance CJ, Ringertz HG et al (2009) Three-dimensional MRI volumetric measurements of the normal fetal colon. AJR Am J Roentgenol 192:761–765PubMedCrossRef Rubesova E, Vance CJ, Ringertz HG et al (2009) Three-dimensional MRI volumetric measurements of the normal fetal colon. AJR Am J Roentgenol 192:761–765PubMedCrossRef
18.
go back to reference Soher BJ, Dale BM, Merkle EM (2007) A review of MR physics: 3 T versus 1.5 T. Magn Reson Imaging Clin N Am 15:277–290PubMedCrossRef Soher BJ, Dale BM, Merkle EM (2007) A review of MR physics: 3 T versus 1.5 T. Magn Reson Imaging Clin N Am 15:277–290PubMedCrossRef
19.
go back to reference Franklin KM, Dale BM, Merkle EM (2008) Improvement in B1-inhomogeneity artifacts in the abdomen at 3 T MR imaging using a radiofrequency cushion. J Magn Reson Imaging 27:1443–1447PubMedCrossRef Franklin KM, Dale BM, Merkle EM (2008) Improvement in B1-inhomogeneity artifacts in the abdomen at 3 T MR imaging using a radiofrequency cushion. J Magn Reson Imaging 27:1443–1447PubMedCrossRef
20.
go back to reference Kataoka M, Isoda H, Maetani Y et al (2007) MR imaging of the female pelvis at 3 tesla: evaluation of image homogeneity using different dielectric pads. J Magn Reson Imaging 26:1572–1577PubMedCrossRef Kataoka M, Isoda H, Maetani Y et al (2007) MR imaging of the female pelvis at 3 tesla: evaluation of image homogeneity using different dielectric pads. J Magn Reson Imaging 26:1572–1577PubMedCrossRef
21.
go back to reference Vernickel P, Roschmann P, Findeklee C et al (2007) Eight-channel transmit/receive body MRI coil at 3 T. Magn Reson Med 58:381–389PubMedCrossRef Vernickel P, Roschmann P, Findeklee C et al (2007) Eight-channel transmit/receive body MRI coil at 3 T. Magn Reson Med 58:381–389PubMedCrossRef
22.
go back to reference Ullmann P, Junge S, Wick M et al (2005) Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels. Magn Reson Med 54:994–1001PubMedCrossRef Ullmann P, Junge S, Wick M et al (2005) Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels. Magn Reson Med 54:994–1001PubMedCrossRef
23.
go back to reference Willinek WA, Gieseke J, Kukuk GM et al (2010) Dual-source parallel radiofrequency excitation body MR imaging compared with standard MR imaging at 3.0 T: initial clinical experience. Radiology 256:966–975PubMedCrossRef Willinek WA, Gieseke J, Kukuk GM et al (2010) Dual-source parallel radiofrequency excitation body MR imaging compared with standard MR imaging at 3.0 T: initial clinical experience. Radiology 256:966–975PubMedCrossRef
24.
go back to reference Baker PN, Johnson IR, Harvey PR et al (1994) A three-year follow-up of children imaged in utero with echo-planar magnetic resonance. Am J Obstet Gynecol 170:32–33PubMedCrossRef Baker PN, Johnson IR, Harvey PR et al (1994) A three-year follow-up of children imaged in utero with echo-planar magnetic resonance. Am J Obstet Gynecol 170:32–33PubMedCrossRef
25.
go back to reference Kanal E, Gillen J, Evans JA et al (1993) Survey of reproductive health among female MR workers. Radiology 187:395–399PubMed Kanal E, Gillen J, Evans JA et al (1993) Survey of reproductive health among female MR workers. Radiology 187:395–399PubMed
26.
go back to reference Myers C, Duncan KR, Gowland PA et al (1998) Failure to detect intrauterine growth restriction following in utero exposure to MRI. Br J Radiol 71:549–551PubMed Myers C, Duncan KR, Gowland PA et al (1998) Failure to detect intrauterine growth restriction following in utero exposure to MRI. Br J Radiol 71:549–551PubMed
27.
go back to reference Denegre JM, Valles JM Jr, Lin K et al (1998) Cleavage planes in frog eggs are altered by strong magnetic fields. Proc Natl Acad Sci U S A 95:14729–14732PubMedCentralPubMedCrossRef Denegre JM, Valles JM Jr, Lin K et al (1998) Cleavage planes in frog eggs are altered by strong magnetic fields. Proc Natl Acad Sci U S A 95:14729–14732PubMedCentralPubMedCrossRef
28.
go back to reference Hand JW, Li Y, Hajnal JV (2010) Numerical study of RF exposure and the resulting temperature rise in the foetus during a magnetic resonance procedure. Phys Med Biol 55:913–930PubMedCrossRef Hand JW, Li Y, Hajnal JV (2010) Numerical study of RF exposure and the resulting temperature rise in the foetus during a magnetic resonance procedure. Phys Med Biol 55:913–930PubMedCrossRef
29.
go back to reference Hand JW, Li Y, Thomas EL et al (2006) Prediction of specific absorption rate in mother and fetus associated with MRI examinations during pregnancy. Magn Reson Med 55:883–893PubMedCrossRef Hand JW, Li Y, Thomas EL et al (2006) Prediction of specific absorption rate in mother and fetus associated with MRI examinations during pregnancy. Magn Reson Med 55:883–893PubMedCrossRef
30.
go back to reference Van den Berg CA, van den Bergen B, Van de Kamer JB et al (2007) Simultaneous B1 + homogenization and specific absorption rate hotspot suppression using a magnetic resonance phased array transmit coil. Magn Reson Med 57:577–586PubMedCrossRef Van den Berg CA, van den Bergen B, Van de Kamer JB et al (2007) Simultaneous B1 + homogenization and specific absorption rate hotspot suppression using a magnetic resonance phased array transmit coil. Magn Reson Med 57:577–586PubMedCrossRef
31.
go back to reference Homann H, Graesslin I, Eggers H et al (2012) Local SAR management by RF shimming: a simulation study with multiple human body models. MAGMA 25:193–204PubMedCrossRef Homann H, Graesslin I, Eggers H et al (2012) Local SAR management by RF shimming: a simulation study with multiple human body models. MAGMA 25:193–204PubMedCrossRef
Metadata
Title
Fetal magnetic resonance imaging: jumping from 1.5 to 3 tesla (preliminary experience)
Authors
Teresa Victoria
Diego Jaramillo
Timothy Paul Leslie Roberts
Deborah Zarnow
Ann Michelle Johnson
Jorge Delgado
Erika Rubesova
Arastoo Vossough
Publication date
01-04-2014
Publisher
Springer Berlin Heidelberg
Published in
Pediatric Radiology / Issue 4/2014
Print ISSN: 0301-0449
Electronic ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-013-2857-0

Other articles of this Issue 4/2014

Pediatric Radiology 4/2014 Go to the issue

Hermes

Hermes