Skip to main content
Top
Published in: Pediatric Radiology 2/2011

01-09-2011 | ALARA-CT

CT utilization – trends and developments beyond the United States’ borders

Author: Karen E. Thomas

Published in: Pediatric Radiology | Special Issue 2/2011

Login to get access

Abstract

There has been an exponential rise in the use of CT during the last 25 years, with similar trending of data from regions across the world. However, variability in levels of utilization and patterns of practice in both adult and pediatric populations can be identified. Multiple technical, health care, regulatory and cultural factors are shaping our use of this modality. Surveys of pediatric CT dose are now available from several countries with the development of proposed diagnostic reference levels. Challenges of this process will be discussed. This short presentation is not intended as a comprehensive review of the infrastructure and numerous advances in pediatric CT radiation protection occurring around the world but aims to highlight a few aspects.
Literature
2.
go back to reference Mettler FA, Thomadsen BR, Bhargavan M et al (2008) Medical radiation exposure in the US in 2006: preliminary results. Health Phys 95:502–507PubMedCrossRef Mettler FA, Thomadsen BR, Bhargavan M et al (2008) Medical radiation exposure in the US in 2006: preliminary results. Health Phys 95:502–507PubMedCrossRef
3.
go back to reference You JJ, Alter DA, Iron K et al (2007) Diagnostic Services in Ontario: Descriptive analysis and Juristictional Review. ICES Investigative Report. Institute for Clinical Evaluation Sciences, Toronto, Canada You JJ, Alter DA, Iron K et al (2007) Diagnostic Services in Ontario: Descriptive analysis and Juristictional Review. ICES Investigative Report. Institute for Clinical Evaluation Sciences, Toronto, Canada
5.
go back to reference Tsushima Y, Taketomi-Takahashi A, Takei H et al (2010) Radiation exposure from CT examinations in Japan. BMC Med Imaging 10:1–8CrossRef Tsushima Y, Taketomi-Takahashi A, Takei H et al (2010) Radiation exposure from CT examinations in Japan. BMC Med Imaging 10:1–8CrossRef
6.
go back to reference Chen J, Moir D (2010) An estimation of the annual effective dose to the Canadian population from medical CT examinations. J Radiol Prot 30:131–137PubMedCrossRef Chen J, Moir D (2010) An estimation of the annual effective dose to the Canadian population from medical CT examinations. J Radiol Prot 30:131–137PubMedCrossRef
9.
go back to reference Hart D, Wall BF, Hillier MC et al (2010) Frequency and collective dose for medical and dental X-ray examinations in the UK, 2008. Report HPA-CRCE-012 from the Health Protection Agency, Chilton, Oxfordshire, UK Hart D, Wall BF, Hillier MC et al (2010) Frequency and collective dose for medical and dental X-ray examinations in the UK, 2008. Report HPA-CRCE-012 from the Health Protection Agency, Chilton, Oxfordshire, UK
10.
go back to reference Borretzen I, Lysdahl KB, Olerud HM (2007) Diagnostic radiology in Norway – trends in examination frequency and collective effective dose. Radiat Protect Dosim 124:339–347CrossRef Borretzen I, Lysdahl KB, Olerud HM (2007) Diagnostic radiology in Norway – trends in examination frequency and collective effective dose. Radiat Protect Dosim 124:339–347CrossRef
11.
go back to reference National Council on Radiation Protection and Measurements (2009) Ionizing radiation exposure of the population of the United States: National Council on Radiation Protection and Measurements Report No. 160. Bethesda, MD National Council on Radiation Protection and Measurements (2009) Ionizing radiation exposure of the population of the United States: National Council on Radiation Protection and Measurements Report No. 160. Bethesda, MD
12.
go back to reference Aroura A, Bochud FO, Valley J-F et al (2007) Number of X-ray examinations performed on paediatric and geriatric patients compared with adult patients. Radiat Protect Dosim 123:402–408CrossRef Aroura A, Bochud FO, Valley J-F et al (2007) Number of X-ray examinations performed on paediatric and geriatric patients compared with adult patients. Radiat Protect Dosim 123:402–408CrossRef
13.
go back to reference Townsend BA, Callahan MJ, Zurakowski D et al (2010) Has pediatric CT at children’s hospitals reached its peak? AJR 194:1194–1196PubMedCrossRef Townsend BA, Callahan MJ, Zurakowski D et al (2010) Has pediatric CT at children’s hospitals reached its peak? AJR 194:1194–1196PubMedCrossRef
14.
go back to reference Shrimpton PB, Wall BF (2000) Reference doses for paediatric computed tomography. Radiat Protect Dosim 90:249–252 Shrimpton PB, Wall BF (2000) Reference doses for paediatric computed tomography. Radiat Protect Dosim 90:249–252
16.
go back to reference Verdun FR, Gutierrez D, Vader JP et al (2008) CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland. Eur Radiol 18:1980–1986PubMedCrossRef Verdun FR, Gutierrez D, Vader JP et al (2008) CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland. Eur Radiol 18:1980–1986PubMedCrossRef
17.
go back to reference Brisse HJ, Aubert B (2009) CT exposure from pediatric MDCT: results from the 2007–2008 SFIPP/ISRN survey. J Radiol 90:207–215PubMedCrossRef Brisse HJ, Aubert B (2009) CT exposure from pediatric MDCT: results from the 2007–2008 SFIPP/ISRN survey. J Radiol 90:207–215PubMedCrossRef
18.
go back to reference Pages J, Buls N, Osteaux M (2003) CT doses in Children: a multicentre study. Br J Radiol 76:803–811PubMedCrossRef Pages J, Buls N, Osteaux M (2003) CT doses in Children: a multicentre study. Br J Radiol 76:803–811PubMedCrossRef
19.
go back to reference Yakoumakis E, Karlatira M, Gialousis G et al (2009) Effective dose variation in pediatric computed tomography: dose reference levels in Greece. Health Phys 97:595–603PubMedCrossRef Yakoumakis E, Karlatira M, Gialousis G et al (2009) Effective dose variation in pediatric computed tomography: dose reference levels in Greece. Health Phys 97:595–603PubMedCrossRef
20.
go back to reference Etude des doses en tomodensitometrie (CT Scan). Association des physiciens et ingenieurs biomedicaux du Quebec. Comite de radioprotection, 25 Feb 2008 Etude des doses en tomodensitometrie (CT Scan). Association des physiciens et ingenieurs biomedicaux du Quebec. Comite de radioprotection, 25 Feb 2008
21.
go back to reference Moss M, McLean D (2006) Paediatric and adult computed tomography practice and patient dose in Australia. Australas Radiol 50:33–40PubMedCrossRef Moss M, McLean D (2006) Paediatric and adult computed tomography practice and patient dose in Australia. Australas Radiol 50:33–40PubMedCrossRef
22.
go back to reference Muhogora N, Ahmed NA, AlSuwaidi JS et al (2010) Paediatric CT examinations in 19 developing countries: frequency and radiation dose. Radiat Protect Dosim 140:49–58CrossRef Muhogora N, Ahmed NA, AlSuwaidi JS et al (2010) Paediatric CT examinations in 19 developing countries: frequency and radiation dose. Radiat Protect Dosim 140:49–58CrossRef
23.
go back to reference Buls N, Bosmans H, Mommaert C et al (2009) Current status on pediatric CT doses: a multicenter study. Abstract SST13-06, RSNA, Chicago, IL Buls N, Bosmans H, Mommaert C et al (2009) Current status on pediatric CT doses: a multicenter study. Abstract SST13-06, RSNA, Chicago, IL
24.
go back to reference International Commission on Radiological Protection. ICRP Publication 73. Radiological protection and safety in medicine. A report of the International Commission on Radiological Protection. Ann ICRP 1996; 26:1–47 International Commission on Radiological Protection. ICRP Publication 73. Radiological protection and safety in medicine. A report of the International Commission on Radiological Protection. Ann ICRP 1996; 26:1–47
26.
go back to reference Leitz W, Almen A (2005) Unsolved or unsolvable problems with diagnostic reference levels. Radiat Protect Dosim 114:180–182CrossRef Leitz W, Almen A (2005) Unsolved or unsolvable problems with diagnostic reference levels. Radiat Protect Dosim 114:180–182CrossRef
27.
go back to reference Statutory Instruments 2000 No. 1059. The Ionising Radiation (Medical Exposure) Regulations 2000. (London: The Stationary Office) Available via www.dh.gov.uk. Accessed 10 Jan 2011 Statutory Instruments 2000 No. 1059. The Ionising Radiation (Medical Exposure) Regulations 2000. (London: The Stationary Office) Available via www.​dh.​gov.​uk. Accessed 10 Jan 2011
28.
go back to reference Presentation des principales dispositions reglementaires de radioprotection applicable en radiologie medicale et dentaire (2009). Autorite de surete nucleaire. Available via www.asn.fr. Accessed 10 Jan 2011 Presentation des principales dispositions reglementaires de radioprotection applicable en radiologie medicale et dentaire (2009). Autorite de surete nucleaire. Available via www.​asn.​fr. Accessed 10 Jan 2011
Metadata
Title
CT utilization – trends and developments beyond the United States’ borders
Author
Karen E. Thomas
Publication date
01-09-2011
Publisher
Springer-Verlag
Published in
Pediatric Radiology / Issue Special Issue 2/2011
Print ISSN: 0301-0449
Electronic ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-011-2101-8

Other articles of this Special Issue 2/2011

Pediatric Radiology 2/2011 Go to the issue