Published in: Pediatric Cardiology 5/2014

01-06-2014 | Original Article

Measurement of Oxygen Consumption in Children Undergoing Cardiac Catheterization: Comparison Between Mass Spectrometry and the Breath-by-Breath Method

Authors: Long Guo, Yong Cui, Scott Pharis, Mark Walsh, Joseph Atallah, Meng-Wei Tan, Jennifer Rutledge, J. Y. Coe, Ian Adatia

Published in: Pediatric Cardiology | Issue 5/2014

Login to get access

Abstract

Accurate measurement of oxygen consumption (VO2) is important to precise calculation of blood flow using the Fick equation. This study aimed to validate the breath-by-breath method (BBBM) of measuring oxygen consumption VO2 compared with respiratory mass spectroscopy (MS) for intubated children during cardiac catheterization. The study used MS and BBBM to measure VO2 continuously and simultaneously for 10 min in consecutive anesthetized children undergoing cardiac catheterization who were intubated with a cuffed endotracheal tube, ventilated mechanically, and hemodynamically stable, with normal body temperature. From 26 patients, 520 data points were obtained. The mean VO2 was 94.5 ml/min (95 % confidence interval [CI] 65.7–123.3 ml/min) as measured by MS and 91.4 ml/min (95 % CI 64.9–117.9 ml/min) as measured by BBBM. The mean difference in VO2 measurements between MS and BBBM (3.1 ml/min; 95 % CI −1.7 to +7.9 ml/min) was not significant (p = 0.19). The MS and BBBM VO2 measurements were highly correlated (R 2 = 0.98; P < 0.0001). Bland–Altman analysis showed good correspondence between MS and BBBM, with a mean difference of −3.01 and 95 % limits of agreement ranging from −26.2 to +20.0. The mean VO2 indexed to body surface area did not differ significantly between MS and BBBM (3.4 ml/min m2; 95 % CI −1.4 to 8.2; p = 0.162). The mean difference and limits of agreement were −3.8 ml/min m2 (range, −19.9 to 26.7). Both MS and BBBM may be used to measure VO2 in anesthetized intubated children undergoing cardiac catheterization. The two methods demonstrated excellent agreement. However, BBBM may be more suited to clinical use with children.
Literature
1.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310CrossRefPubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310CrossRefPubMed
2.
go back to reference Carter J, Jeukendrup AE (2002) Validity and reliability of three commercially available breath-by-breath respiratory systems. Eur J Appl Physiol 86:435–441CrossRefPubMed Carter J, Jeukendrup AE (2002) Validity and reliability of three commercially available breath-by-breath respiratory systems. Eur J Appl Physiol 86:435–441CrossRefPubMed
3.
go back to reference Cigarroa RG, Lange RA, Williams RH et al (1989) Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation. Am J Med 86:417–420CrossRefPubMed Cigarroa RG, Lange RA, Williams RH et al (1989) Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation. Am J Med 86:417–420CrossRefPubMed
4.
go back to reference Davies NJ, Denison DM (1979) The measurement of metabolic gas exchange and minute volume by mass spectrometry alone. Respir Physiol 36:261–267CrossRefPubMed Davies NJ, Denison DM (1979) The measurement of metabolic gas exchange and minute volume by mass spectrometry alone. Respir Physiol 36:261–267CrossRefPubMed
5.
go back to reference Hammarlund K (1984) Measurement of oxygen consumption in preterm infants: assessment of a method using a mass spectrometer. Clin Physiol 4:519–531CrossRefPubMed Hammarlund K (1984) Measurement of oxygen consumption in preterm infants: assessment of a method using a mass spectrometer. Clin Physiol 4:519–531CrossRefPubMed
6.
go back to reference Hillis LD, Firth BG, Winniford MD (1985) Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output. Am J Cardiol 56:764–768CrossRefPubMed Hillis LD, Firth BG, Winniford MD (1985) Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output. Am J Cardiol 56:764–768CrossRefPubMed
7.
go back to reference Hoeper MM, Maier R, Tongers J et al (1999) Determination of cardiac output by the Fick method, thermodilution, and acetylene rebreathing in pulmonary hypertension. Am J Respir Crit Care Med 160:535–541CrossRefPubMed Hoeper MM, Maier R, Tongers J et al (1999) Determination of cardiac output by the Fick method, thermodilution, and acetylene rebreathing in pulmonary hypertension. Am J Respir Crit Care Med 160:535–541CrossRefPubMed
8.
go back to reference Li J, Bush A, Schulze-Neick I et al (2003) Measured versus estimated oxygen consumption in ventilated patients with congenital heart disease: the validity of predictive equations. Crit Care Med 31:1235–1240CrossRefPubMed Li J, Bush A, Schulze-Neick I et al (2003) Measured versus estimated oxygen consumption in ventilated patients with congenital heart disease: the validity of predictive equations. Crit Care Med 31:1235–1240CrossRefPubMed
9.
go back to reference Lundell BP, Casas ML, Wallgren CG (1996) Oxygen consumption in infants and children during heart catheterization. Pediatr Cardiol 17:207–213CrossRefPubMed Lundell BP, Casas ML, Wallgren CG (1996) Oxygen consumption in infants and children during heart catheterization. Pediatr Cardiol 17:207–213CrossRefPubMed
10.
go back to reference Nishikawa T, Dohi S (1993) Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 40:142–153CrossRefPubMed Nishikawa T, Dohi S (1993) Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 40:142–153CrossRefPubMed
11.
go back to reference Reybrouck T, Deroost F, Van der Hauwaert LG (1992) Evaluation of breath-by-breath measurement of respiratory gas exchange in pediatric exercise testing. Chest 102:147–152CrossRefPubMed Reybrouck T, Deroost F, Van der Hauwaert LG (1992) Evaluation of breath-by-breath measurement of respiratory gas exchange in pediatric exercise testing. Chest 102:147–152CrossRefPubMed
12.
go back to reference Schmitz A, Kretschmar O, Knirsch W et al (2008) Comparison of calculated with measured oxygen consumption in children undergoing cardiac catheterization. Pediatr Cardiol 29:1054–1058CrossRefPubMed Schmitz A, Kretschmar O, Knirsch W et al (2008) Comparison of calculated with measured oxygen consumption in children undergoing cardiac catheterization. Pediatr Cardiol 29:1054–1058CrossRefPubMed
13.
go back to reference Shekerdemian L, Shore D, Lincoln C et al (1996) Negative-pressure ventilation improves cardiac output after right heart surgery. Circulation 94:II-49–II-55 Shekerdemian L, Shore D, Lincoln C et al (1996) Negative-pressure ventilation improves cardiac output after right heart surgery. Circulation 94:II-49–II-55
14.
go back to reference Sodal IE (1989) The medical mass spectrometer. Biomed Instrum Technol 23:469–476PubMed Sodal IE (1989) The medical mass spectrometer. Biomed Instrum Technol 23:469–476PubMed
Metadata
Title
Measurement of Oxygen Consumption in Children Undergoing Cardiac Catheterization: Comparison Between Mass Spectrometry and the Breath-by-Breath Method
Authors
Long Guo
Yong Cui
Scott Pharis
Mark Walsh
Joseph Atallah
Meng-Wei Tan
Jennifer Rutledge
J. Y. Coe
Ian Adatia
Publication date
01-06-2014
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 5/2014
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-013-0855-5

Other articles of this Issue 5/2014

Pediatric Cardiology 5/2014 Go to the issue