Skip to main content
Top
Published in: Neuroradiology 3/2016

01-03-2016 | Diagnostic Neuroradiology

4D flow MRI assessment of extracranial-intracranial bypass: qualitative and quantitative evaluation of the hemodynamics

Authors: Tetsuro Sekine, Ryo Takagi, Yasuo Amano, Yasuo Murai, Erika Orita, Yoshio Matsumura, Shin-ichiro Kumita

Published in: Neuroradiology | Issue 3/2016

Login to get access

Abstract

Introduction

Our aim was to assess the feasibility of using time-resolved 3D phase-contrast (4D flow) MRI to characterize extracranial-intracranial (EC-IC) bypass.

Methods

We enrolled 32 patients who underwent EC-IC bypass (15 men, 17 women; mean age 66.4 years). In all, 16 underwent radial artery graft (RAG) bypass and 16 underwent superficial temporal artery (STA) bypass. 4D flow MRI, time-of-flight (TOF) magnetic resonance angiography (MRA), and computed tomography angiography (CTA) were performed. Bypass patency, flow direction, and blood flow volume (BFV) of each artery were determined by 4D flow MRI. Arterial diameters were measured by TOF-MRA and CTA. We compared RAG and STA bypasses by evaluating the flow direction and BFV of each artery. We evaluated the correlation between arterial diameters (measured by CTA or MRA) and the BFV and the detectability of flow direction (measured by 4D flow MRI) of each artery.

Results

4D flow MRI confirmed the patency of each bypass artery. Flow direction of the M1 segment of the middle cerebral artery and BFV in the bypass artery differed between RAG and STA groups (p < 0.01). BFV in the bypass slightly correlated with the diameters on CTA (p < 0.05, R 2 = 0.287). Of the 29 arteries in the circle of Willis, nine were not depicted on 4D flow MRI. Cutoff values for arterial diameters on CTA and TOF-MRA for detecting the artery on 4D flow MRI were 2.4 and 1.8 mm, respectively.

Conclusion

4D flow MRI provided unique information for characterizing EC-IC bypasses, although this detectability is limited when addressing small arteries with slow flow.
Appendix
Available only for authorised users
Literature
1.
go back to reference Hanggi D, Steiger HJ, Vajkoczy P (2014) The role of MCA-STA bypass surgery after COSS and JET: the European point of view. Acta Neurochir Suppl 119:77–78PubMed Hanggi D, Steiger HJ, Vajkoczy P (2014) The role of MCA-STA bypass surgery after COSS and JET: the European point of view. Acta Neurochir Suppl 119:77–78PubMed
2.
go back to reference Vilela MD, Newell DW (2008) Superficial temporal artery to middle cerebral artery bypass: past, present, and future. Neurosurg Focus 24:2CrossRef Vilela MD, Newell DW (2008) Superficial temporal artery to middle cerebral artery bypass: past, present, and future. Neurosurg Focus 24:2CrossRef
3.
go back to reference Sia SF, Morgan MK (2013) High flow extracranial-to-intracranial brain bypass surgery. J Clin Neurosci 20:1–5CrossRefPubMed Sia SF, Morgan MK (2013) High flow extracranial-to-intracranial brain bypass surgery. J Clin Neurosci 20:1–5CrossRefPubMed
4.
go back to reference Murai Y, Mizunari T, Umeoka K, Tateyama K, Kobayashi S, Teramoto A (2011) Radial artery grafts for symptomatic cavernous carotid aneurysms in elderly patients. Neurol India 59:537–541CrossRefPubMed Murai Y, Mizunari T, Umeoka K, Tateyama K, Kobayashi S, Teramoto A (2011) Radial artery grafts for symptomatic cavernous carotid aneurysms in elderly patients. Neurol India 59:537–541CrossRefPubMed
5.
go back to reference Kataoka H, Miyamoto S, Ogasawara K et al (2015) Results of prospective cohort study on symptomatic cerebrovascular occlusive disease showing mild hemodynamic compromise [Japanese extracranial-intracranial bypass trial (JET)-2 study]. Neurol Med Chir (Tokyo) 55:460–468CrossRef Kataoka H, Miyamoto S, Ogasawara K et al (2015) Results of prospective cohort study on symptomatic cerebrovascular occlusive disease showing mild hemodynamic compromise [Japanese extracranial-intracranial bypass trial (JET)-2 study]. Neurol Med Chir (Tokyo) 55:460–468CrossRef
6.
go back to reference Kaufmann TJ, Huston J 3rd, Mandrekar JN, Schleck CD, Thielen KR, Kallmes DF (2007) Complications of diagnostic cerebral angiography: evaluation of 19,826 consecutive patients. Radiology 243:812–819CrossRefPubMed Kaufmann TJ, Huston J 3rd, Mandrekar JN, Schleck CD, Thielen KR, Kallmes DF (2007) Complications of diagnostic cerebral angiography: evaluation of 19,826 consecutive patients. Radiology 243:812–819CrossRefPubMed
7.
go back to reference Schaller B (2008) Extracranial-intracranial bypass to reduce the risk of ischemic stroke in intracranial aneurysms of the anterior cerebral circulation: a systematic review. J Stroke Cerebrovasc Dis 17:287–298CrossRefPubMed Schaller B (2008) Extracranial-intracranial bypass to reduce the risk of ischemic stroke in intracranial aneurysms of the anterior cerebral circulation: a systematic review. J Stroke Cerebrovasc Dis 17:287–298CrossRefPubMed
8.
go back to reference Thines L, Agid R, Dehdashti AR et al (2009) Assessment of extracranial-intracranial bypass patency with 64-slice multidetector computerized tomography angiography. Neuroradiology 51:505–515CrossRefPubMed Thines L, Agid R, Dehdashti AR et al (2009) Assessment of extracranial-intracranial bypass patency with 64-slice multidetector computerized tomography angiography. Neuroradiology 51:505–515CrossRefPubMed
9.
go back to reference Praharaj SS, Coulthard A, Gholkar A, English P, Mendelow AD (1996) Magnetic resonance angiographic assessment after extracranial-intracranial bypass surgery. J Neurol Neurosurg Psychiatry 60:439–441CrossRefPubMedPubMedCentral Praharaj SS, Coulthard A, Gholkar A, English P, Mendelow AD (1996) Magnetic resonance angiographic assessment after extracranial-intracranial bypass surgery. J Neurol Neurosurg Psychiatry 60:439–441CrossRefPubMedPubMedCentral
10.
go back to reference Tsuchiya K, Imai M, Nitatori T, Kimura T (2013) Postoperative evaluation of superficial temporal artery-middle cerebral artery bypass using an MR angiography technique with combined white-blood and black-blood sequences. J Magn Reson Imaging 38:671–676CrossRefPubMed Tsuchiya K, Imai M, Nitatori T, Kimura T (2013) Postoperative evaluation of superficial temporal artery-middle cerebral artery bypass using an MR angiography technique with combined white-blood and black-blood sequences. J Magn Reson Imaging 38:671–676CrossRefPubMed
11.
go back to reference Tsuchiya K, Honya K, Fujikawa A, Tateishi H, Shiokawa Y (2005) Postoperative assessment of extracranial–intracranial bypass by time-resolved 3D contrast-enhanced MR angiography using parallel imaging. Am J Neuroradiol 26:2243–2247PubMed Tsuchiya K, Honya K, Fujikawa A, Tateishi H, Shiokawa Y (2005) Postoperative assessment of extracranial–intracranial bypass by time-resolved 3D contrast-enhanced MR angiography using parallel imaging. Am J Neuroradiol 26:2243–2247PubMed
12.
go back to reference Akashi T, Taoka T, Miyasaka T et al (2010) Magnetic resonance angiography with midsagittal saturation for the assessment of blood flow from superficial temporal artery-to-middle cerebral artery bypass. J Comput Assist Tomogr 34:89–92CrossRefPubMed Akashi T, Taoka T, Miyasaka T et al (2010) Magnetic resonance angiography with midsagittal saturation for the assessment of blood flow from superficial temporal artery-to-middle cerebral artery bypass. J Comput Assist Tomogr 34:89–92CrossRefPubMed
13.
go back to reference Neff KW, Horn P, Dinter D, Vajkoczy P, Schmiedek P, Duber C (2004) Extracranial-intracranial arterial bypass surgery improves total brain blood supply in selected symptomatic patients with unilateral internal carotid artery occlusion and insufficient collateralization. Neuroradiology 46:730–737CrossRefPubMed Neff KW, Horn P, Dinter D, Vajkoczy P, Schmiedek P, Duber C (2004) Extracranial-intracranial arterial bypass surgery improves total brain blood supply in selected symptomatic patients with unilateral internal carotid artery occlusion and insufficient collateralization. Neuroradiology 46:730–737CrossRefPubMed
14.
go back to reference Amin-Hanjani S, Shin JH, Zhao M, Du X, Charbel FT (2007) Evaluation of extracranial-intracranial bypass using quantitative magnetic resonance angiography. J Neurosurg 106:291–298CrossRefPubMed Amin-Hanjani S, Shin JH, Zhao M, Du X, Charbel FT (2007) Evaluation of extracranial-intracranial bypass using quantitative magnetic resonance angiography. J Neurosurg 106:291–298CrossRefPubMed
15.
go back to reference Horn P, Vajkoczy P, Schmiedek P, Neff W (2004) Evaluation of extracranial-intracranial arterial bypass function with magnetic resonance angiography. Neuroradiology 46:723–729CrossRefPubMed Horn P, Vajkoczy P, Schmiedek P, Neff W (2004) Evaluation of extracranial-intracranial arterial bypass function with magnetic resonance angiography. Neuroradiology 46:723–729CrossRefPubMed
16.
go back to reference Lanzman R, Kröpil P, Schmitt P et al (2011) Nonenhanced ECG-gated time-resolved 4D Steady-state free precession (SSFP) MR angiography (MRA) for assessment of cerebral collateral flow: comparison with digital subtraction angiography (DSA). Eur Radiol 21:1329–1338CrossRefPubMed Lanzman R, Kröpil P, Schmitt P et al (2011) Nonenhanced ECG-gated time-resolved 4D Steady-state free precession (SSFP) MR angiography (MRA) for assessment of cerebral collateral flow: comparison with digital subtraction angiography (DSA). Eur Radiol 21:1329–1338CrossRefPubMed
17.
go back to reference Markl M, Frydrychowicz A, Kozerke S, Hope M, Wieben O (2012) 4D flow MRI. J Magn Reson Imaging 36:1015–1036CrossRefPubMed Markl M, Frydrychowicz A, Kozerke S, Hope M, Wieben O (2012) 4D flow MRI. J Magn Reson Imaging 36:1015–1036CrossRefPubMed
18.
go back to reference Meckel S, Leitner L, Bonati LH et al (2013) Intracranial artery velocity measurement using 4D PC MRI at 3 T: comparison with transcranial ultrasound techniques and 2D PC MRI. Neuroradiology 55:389–398CrossRefPubMed Meckel S, Leitner L, Bonati LH et al (2013) Intracranial artery velocity measurement using 4D PC MRI at 3 T: comparison with transcranial ultrasound techniques and 2D PC MRI. Neuroradiology 55:389–398CrossRefPubMed
19.
go back to reference Sekine T, Amano Y, Takagi R, Matsumura Y, Murai Y, Kumita S (2014) Feasibility of 4D flow MR imaging of the brain with either Cartesian y-z radial sampling or k-t SENSE: comparison with 4D flow MR imaging using SENSE. Magn Reson Med Sci 13:15–24CrossRefPubMed Sekine T, Amano Y, Takagi R, Matsumura Y, Murai Y, Kumita S (2014) Feasibility of 4D flow MR imaging of the brain with either Cartesian y-z radial sampling or k-t SENSE: comparison with 4D flow MR imaging using SENSE. Magn Reson Med Sci 13:15–24CrossRefPubMed
20.
go back to reference Stankovic Z, Jung B, Collins J et al (2014) Reproducibility study of four-dimensional flow MRI of arterial and portal venous liver hemodynamics: influence of spatio-temporal resolution. Magn Reson Med 72:477–484CrossRefPubMedPubMedCentral Stankovic Z, Jung B, Collins J et al (2014) Reproducibility study of four-dimensional flow MRI of arterial and portal venous liver hemodynamics: influence of spatio-temporal resolution. Magn Reson Med 72:477–484CrossRefPubMedPubMedCentral
21.
go back to reference Lotz J, Meier C, Leppert A, Galanski M (2002) Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Radiographics 22:651–671CrossRefPubMed Lotz J, Meier C, Leppert A, Galanski M (2002) Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Radiographics 22:651–671CrossRefPubMed
22.
go back to reference Brockmann C, Gerigk L, Vajkoczy P, Groden C, Neumaier-Probst E (2012) Magnetic resonance imaging flow quantification of non-occlusive excimer laser-assisted EC-IC high-flow bypass in the treatment of complex intracranial aneurysms. Clin Neuroradiol 22:39–45CrossRefPubMed Brockmann C, Gerigk L, Vajkoczy P, Groden C, Neumaier-Probst E (2012) Magnetic resonance imaging flow quantification of non-occlusive excimer laser-assisted EC-IC high-flow bypass in the treatment of complex intracranial aneurysms. Clin Neuroradiol 22:39–45CrossRefPubMed
23.
go back to reference Ikari Y, Nishio T, Makishi Y et al (2012) Head motion evaluation and correction for PET scans with 18F-FDG in the Japanese Alzheimer’s disease neuroimaging initiative (J-ADNI) multi-center study. Ann Nucl Med 26:535–544CrossRefPubMed Ikari Y, Nishio T, Makishi Y et al (2012) Head motion evaluation and correction for PET scans with 18F-FDG in the Japanese Alzheimer’s disease neuroimaging initiative (J-ADNI) multi-center study. Ann Nucl Med 26:535–544CrossRefPubMed
24.
25.
go back to reference van Ooij P, Zwanenburg JJ, Visser F et al (2013) Quantification and visualization of flow in the circle of willis: time-resolved three-dimensional phase contrast MRI at 7 T compared with 3 T. Magn Reson Med 69:868–876CrossRefPubMed van Ooij P, Zwanenburg JJ, Visser F et al (2013) Quantification and visualization of flow in the circle of willis: time-resolved three-dimensional phase contrast MRI at 7 T compared with 3 T. Magn Reson Med 69:868–876CrossRefPubMed
26.
go back to reference Pedersen H, Kozerke S, Ringgaard S, Nehrke K, Kim WY (2009) k-t PCA: temporally constrained k-t BLAST reconstruction using principal component analysis. Magn Reson Med 62:706–716CrossRefPubMed Pedersen H, Kozerke S, Ringgaard S, Nehrke K, Kim WY (2009) k-t PCA: temporally constrained k-t BLAST reconstruction using principal component analysis. Magn Reson Med 62:706–716CrossRefPubMed
27.
go back to reference Bock J, Frydrychowicz A, Stalder AF et al (2010) 4D phase contrast MRI at 3 T: effect of standard and blood-pool contrast agents on SNR, PC-MRA, and blood flow visualization. Magn Reson Med 63:330–338CrossRefPubMed Bock J, Frydrychowicz A, Stalder AF et al (2010) 4D phase contrast MRI at 3 T: effect of standard and blood-pool contrast agents on SNR, PC-MRA, and blood flow visualization. Magn Reson Med 63:330–338CrossRefPubMed
28.
go back to reference Ha H, Kim GB, Kweon J et al (2015) Multi-VENC acquisition of four-dimensional phase-contrast MRI to improve precision of velocity field measurement. Magn Reson Med. doi:10.1002/mrm.25715 Ha H, Kim GB, Kweon J et al (2015) Multi-VENC acquisition of four-dimensional phase-contrast MRI to improve precision of velocity field measurement. Magn Reson Med. doi:10.​1002/​mrm.​25715
Metadata
Title
4D flow MRI assessment of extracranial-intracranial bypass: qualitative and quantitative evaluation of the hemodynamics
Authors
Tetsuro Sekine
Ryo Takagi
Yasuo Amano
Yasuo Murai
Erika Orita
Yoshio Matsumura
Shin-ichiro Kumita
Publication date
01-03-2016
Publisher
Springer Berlin Heidelberg
Published in
Neuroradiology / Issue 3/2016
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-015-1626-1

Other articles of this Issue 3/2016

Neuroradiology 3/2016 Go to the issue