Abstract

Introduction

Imaging has an essential role in the evaluation of correct positioning of electrodes implanted for deep brain stimulation (DBS). Although MRI offers superior anatomic visualization of target sites, there are safety concerns in patients with implanted material; imaging guidelines are inconsistent and vary. The fusion of postoperative CT with preoperative MRI images can be an alternative for the assessment of electrode positioning. The purpose of this study was to assess the accuracy of measurements realized on fused images (acquired without a stereotactic frame) using a manufacturer-provided software.

Methods

Data from 23 Parkinson’s disease patients who underwent bilateral electrode placement for subthalamic nucleus (STN) DBS were acquired. Preoperative high-resolution T2-weighted sequences at 3 T, and postoperative CT series were fused using a commercially available software. Electrode tip position was measured on the obtained images in three directions (in relation to the midline, the AC-PC line and an AC-PC line orthogonal, respectively) and assessed in relation to measures realized on postoperative 3D T1 images acquired at 1.5 T.

Results

Mean differences between measures carried out on fused images and on postoperative MRI lay between 0.17 and 0.97 mm.

Conclusion

Fusion of CT and MRI images provides a safe and fast technique for postoperative assessment of electrode position in DBS.
Literature
1.
go back to reference Benabid AL, Pollak P, Gervason C, Hoffmann D, Gao DM, Hommel M, Perret JE, de Rougemont J (1991) Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus. Lancet 337(8738):403–406CrossRefPubMed Benabid AL, Pollak P, Gervason C, Hoffmann D, Gao DM, Hommel M, Perret JE, de Rougemont J (1991) Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus. Lancet 337(8738):403–406CrossRefPubMed
2.
go back to reference Benabid AL, Pollak P, Louveau A, Henry S, de Rougemont J (1987) Combined (thalamotomy and stimulation) stereotactic surgery of the VIM thalamic nucleus for bilateral Parkinson disease. Appl Neurophysiol 50(1–6):344–346PubMed Benabid AL, Pollak P, Louveau A, Henry S, de Rougemont J (1987) Combined (thalamotomy and stimulation) stereotactic surgery of the VIM thalamic nucleus for bilateral Parkinson disease. Appl Neurophysiol 50(1–6):344–346PubMed
4.
go back to reference Spiegel J, Fuss G, Backens M, Reith W, Magnus T, Becker G, Moringlane JR, Dillmann U (2003) Transient dystonia following magnetic resonance imaging in a patient with deep brain stimulation electrodes for the treatment of Parkinson disease. Case report. J Neurosurg 99(4):772–774. doi:10.3171/jns.2003.99.4.0772 CrossRefPubMed Spiegel J, Fuss G, Backens M, Reith W, Magnus T, Becker G, Moringlane JR, Dillmann U (2003) Transient dystonia following magnetic resonance imaging in a patient with deep brain stimulation electrodes for the treatment of Parkinson disease. Case report. J Neurosurg 99(4):772–774. doi:10.​3171/​jns.​2003.​99.​4.​0772 CrossRefPubMed
5.
go back to reference Henderson JM, Tkach J, Phillips M, Baker K, Shellock FG, Rezai AR (2005) Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson’s disease: case report. Neurosurgery 57(5):E1063, discussion E1063CrossRefPubMed Henderson JM, Tkach J, Phillips M, Baker K, Shellock FG, Rezai AR (2005) Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson’s disease: case report. Neurosurgery 57(5):E1063, discussion E1063CrossRefPubMed
6.
go back to reference Larson PS, Richardson RM, Starr PA, Martin AJ (2008) Magnetic resonance imaging of implanted deep brain stimulators: experience in a large series. Stereotact Funct Neurosurg 86((2):92–100. doi:10.1159/000112430 CrossRefPubMed Larson PS, Richardson RM, Starr PA, Martin AJ (2008) Magnetic resonance imaging of implanted deep brain stimulators: experience in a large series. Stereotact Funct Neurosurg 86((2):92–100. doi:10.​1159/​000112430 CrossRefPubMed
7.
go back to reference Weise LM, Schneider GH, Kupsch A, Haumesser J, Hoffmann KT Postoperative MRI examinations in patients treated by deep brain stimulation using a non-standard protocol. Acta Neurochir (Wien) 152 (12):2021–2027. doi:10.1007/s00701-010-0738-y Weise LM, Schneider GH, Kupsch A, Haumesser J, Hoffmann KT Postoperative MRI examinations in patients treated by deep brain stimulation using a non-standard protocol. Acta Neurochir (Wien) 152 (12):2021–2027. doi:10.​1007/​s00701-010-0738-y
8.
go back to reference Pinsker MO, Herzog J, Falk D, Volkmann J, Deuschl G, Mehdorn M (2008) Accuracy and distortion of deep brain stimulation electrodes on postoperative MRI and CT. Zentralbl Neurochir 69(3):144–147. doi:10.1055/s-2008-1077075 CrossRefPubMed Pinsker MO, Herzog J, Falk D, Volkmann J, Deuschl G, Mehdorn M (2008) Accuracy and distortion of deep brain stimulation electrodes on postoperative MRI and CT. Zentralbl Neurochir 69(3):144–147. doi:10.​1055/​s-2008-1077075 CrossRefPubMed
9.
go back to reference Ferroli P, Franzini A, Marras C, Maccagnano E, D’Incerti L, Broggi G (2004) A simple method to assess accuracy of deep brain stimulation electrode placement: pre-operative stereotactic CT + postoperative MR image fusion. Stereotact Funct Neurosurg 82(1):14–19. doi:10.1159/000076655-76655 CrossRefPubMed Ferroli P, Franzini A, Marras C, Maccagnano E, D’Incerti L, Broggi G (2004) A simple method to assess accuracy of deep brain stimulation electrode placement: pre-operative stereotactic CT + postoperative MR image fusion. Stereotact Funct Neurosurg 82(1):14–19. doi:10.​1159/​000076655-76655 CrossRefPubMed
10.
go back to reference O’Gorman RL, Jarosz JM, Samuel M, Clough C, Selway RP, Ashkan K (2009) CT/MR image fusion in the postoperative assessment of electrodes implanted for deep brain stimulation. Stereotact Funct Neurosurg 87(4):205–210. doi:10.1159/000225973 CrossRefPubMed O’Gorman RL, Jarosz JM, Samuel M, Clough C, Selway RP, Ashkan K (2009) CT/MR image fusion in the postoperative assessment of electrodes implanted for deep brain stimulation. Stereotact Funct Neurosurg 87(4):205–210. doi:10.​1159/​000225973 CrossRefPubMed
11.
go back to reference Shin M, Lefaucheur JP, Penholate MF, Brugieres P, Gurruchaga JM, Nguyen JP (2007) Subthalamic nucleus stimulation in Parkinson’s disease: postoperative CT-MRI fusion images confirm accuracy of electrode placement using intraoperative multi-unit recording. Neurophysiol Clin 37(6):457–466. doi:10.1016/j.neucli.2007.09.005 CrossRefPubMed Shin M, Lefaucheur JP, Penholate MF, Brugieres P, Gurruchaga JM, Nguyen JP (2007) Subthalamic nucleus stimulation in Parkinson’s disease: postoperative CT-MRI fusion images confirm accuracy of electrode placement using intraoperative multi-unit recording. Neurophysiol Clin 37(6):457–466. doi:10.​1016/​j.​neucli.​2007.​09.​005 CrossRefPubMed
12.
go back to reference Yoshida F, Miyagi Y, Morioka T, Hashiguchi K, Murakami N, Matsumoto K, Nagata S, Sasaki T (2008) Assessment of contact location in subthalamic stimulation for Parkinson’s disease by co-registration of computed tomography images. Stereotact Funct Neurosurg 86(3):162–166. doi:10.1159/000120428 CrossRefPubMed Yoshida F, Miyagi Y, Morioka T, Hashiguchi K, Murakami N, Matsumoto K, Nagata S, Sasaki T (2008) Assessment of contact location in subthalamic stimulation for Parkinson’s disease by co-registration of computed tomography images. Stereotact Funct Neurosurg 86(3):162–166. doi:10.​1159/​000120428 CrossRefPubMed
13.
go back to reference Yelnik J, Damier P, Demeret S, Gervais D, Bardinet E, Bejjani BP, Francois C, Houeto JL, Arnule I, Dormont D, Galanaud D, Pidoux B, Cornu P, Agid Y (2003) Localization of stimulating electrodes in patients with Parkinson disease by using a three-dimensional atlas-magnetic resonance imaging coregistration method. J Neurosurg 99(1):89–99. doi:10.3171/jns.2003.99.1.0089 CrossRefPubMed Yelnik J, Damier P, Demeret S, Gervais D, Bardinet E, Bejjani BP, Francois C, Houeto JL, Arnule I, Dormont D, Galanaud D, Pidoux B, Cornu P, Agid Y (2003) Localization of stimulating electrodes in patients with Parkinson disease by using a three-dimensional atlas-magnetic resonance imaging coregistration method. J Neurosurg 99(1):89–99. doi:10.​3171/​jns.​2003.​99.​1.​0089 CrossRefPubMed
14.
go back to reference van Rooijen BD, Backes WH, Schijns OE, Colon A, Hofman PA Brain imaging in chronic epilepsy patients after depth electrode (stereoelectroencephalography) implantation: magnetic resonance imaging or computed tomography? Neurosurgery 73 (3):543–549. doi:10.1227/01.neu.0000431478.79536.68 van Rooijen BD, Backes WH, Schijns OE, Colon A, Hofman PA Brain imaging in chronic epilepsy patients after depth electrode (stereoelectroencephalography) implantation: magnetic resonance imaging or computed tomography? Neurosurgery 73 (3):543–549. doi:10.​1227/​01.​neu.​0000431478.​79536.​68
15.
go back to reference Kondziolka D, Dempsey PK, Lunsford LD, Kestle JR, Dolan EJ, Kanal E, Tasker RR (1992) A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination. Neurosurgery 30(3):402–406, discussion 406–407CrossRefPubMed Kondziolka D, Dempsey PK, Lunsford LD, Kestle JR, Dolan EJ, Kanal E, Tasker RR (1992) A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination. Neurosurgery 30(3):402–406, discussion 406–407CrossRefPubMed
16.
go back to reference Sumanaweera TS, Adler JR Jr, Napel S, Glover GH (1994) Characterization of spatial distortion in magnetic resonance imaging and its implications for stereotactic surgery. Neurosurgery 35(4):696–703, discussion 703–694CrossRefPubMed Sumanaweera TS, Adler JR Jr, Napel S, Glover GH (1994) Characterization of spatial distortion in magnetic resonance imaging and its implications for stereotactic surgery. Neurosurgery 35(4):696–703, discussion 703–694CrossRefPubMed
17.
go back to reference Lee JY, Jeon BS, Paek SH, Lim YH, Kim MR, Kim C Reprogramming guided by the fused images of MRI and CT in subthalamic nucleus stimulation in Parkinson disease. Clin Neurol Neurosurg 112 (1):47–53. doi:10.1016/j.clineuro.2009.10.008 Lee JY, Jeon BS, Paek SH, Lim YH, Kim MR, Kim C Reprogramming guided by the fused images of MRI and CT in subthalamic nucleus stimulation in Parkinson disease. Clin Neurol Neurosurg 112 (1):47–53. doi:10.​1016/​j.​clineuro.​2009.​10.​008
19.
go back to reference Bondallaz P, Boex C, Rossetti AO, Foletti G, Spinelli L, Vulliemoz S, Seeck M, Pollo C Electrode location and clinical outcome in hippocampal electrical stimulation for mesial temporal lobe epilepsy. Seizure 22 (5):390–395. doi:10.1016/j.seizure.2013.02.007 Bondallaz P, Boex C, Rossetti AO, Foletti G, Spinelli L, Vulliemoz S, Seeck M, Pollo C Electrode location and clinical outcome in hippocampal electrical stimulation for mesial temporal lobe epilepsy. Seizure 22 (5):390–395. doi:10.​1016/​j.​seizure.​2013.​02.​007
Metadata
Title
Evaluation of electrode position in deep brain stimulation by image fusion (MRI and CT)
Authors
I. Barnaure
P. Pollak
S. Momjian
J. Horvath
K. O. Lovblad
C. Boëx
J. Remuinan
P. Burkhard
M. I. Vargas
Publication date
01-09-2015
Publisher
Springer Berlin Heidelberg
Published in
Neuroradiology / Issue 9/2015
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-015-1547-z

Other articles of this Issue 9/2015

Neuroradiology 9/2015 Go to the issue