Late angiographic and clinical follow-up results of 100 consecutive aneurysms treated with Onyx reconstruction: largest single-center experience

Authors: H. Saruhan Cekirge, Isil Saatci, M. Halil Ozturk, Barbaros Cil, Anil Arat, Michel Mawad, Fikret Ergungor, Deniz Belen, Uygur Er, Sami Turk, Murat Bavbek, Zeki Sekerci, Ethem Beskonakli, Osman E. Ozcan, Tuncalp Ozgen

Published in: Neuroradiology | Issue 2/2006

Login to get access

Abstract

We present the long-term clinical and angiographic follow-up results of 100 consecutive intracranial aneurysms treated with Onyx liquid embolic system (MTI, Irvine, Calif.), either alone or combined with an adjunctive stent, in a single center. A total of 100 aneurysms in 94 patients were treated with endosaccular Onyx packing. Intracranial stenting was used adjunctively in 25 aneurysms including 19 during initial treatment and 6 during retreatment. All aneurysms except two were located in the internal carotid artery. Of the 100 aneurysms, 35 were giant or large/wide-necked, and 65 were small. Follow-up angiography was performed in all 91 surviving patients (96 aneurysms) at 3 and/or 6 months. Follow-up angiography was performed at 1, 2, 3, 4 and 5 years in 90, 41, 26, 6 and 2 patients, respectively. Overall, aneurysm recanalization was observed in 12 of 96 aneurysms with follow-up angiography (12.5%). All 12 were large or giant aneurysms, resulting in a 36% recanalization rate in the large and giant aneurysm group. One aneurysm out of 25 treated with the combination of a stent and Onyx showed recanalization. There was also no recanalization in the follow-up of small internal carotid artery aneurysms treated with balloon assistance only. At final follow-up, procedure- or device-related permanent neurological morbidity was present in eight patients (8.3%). There were two procedure-related and one disease-related (subarachnoid hemorrhage) deaths (mortality 3.2%). Delayed spontaneous asymptomatic occlusion of the parent vessel occurred in two patients, detected on routine follow-up. Onyx provides durable aneurysm occlusion with parent artery reconstruction resulting in perfectly stable 1-year to 5-year follow-up angiography both in small aneurysms treated with balloon assistance only (0% recanalization rate) and large or giant aneurysms treated with stent and Onyx combination (4% recanalization rate). Endosaccular Onyx packing with balloon assistance may not be adequate for stable long-term results in those with a large or giant aneurysm. However, the recanalization rate of 36% in these aneurysms is better than the reported results with other techniques, i.e., coils with or without adjunctive bare stents.
Literature
1.
go back to reference Mawad ME, Klucznik RP, Ciceri EF, Cekirge S, Moret J (2001) Endovascular treatment of cerebral aneurysms with the liquid polymer Onyx: initial clinical experience. Presented at the 39th Annual Meeting of the American Society of Neuroradiology, Boston, 23–27 April, p 290 Mawad ME, Klucznik RP, Ciceri EF, Cekirge S, Moret J (2001) Endovascular treatment of cerebral aneurysms with the liquid polymer Onyx: initial clinical experience. Presented at the 39th Annual Meeting of the American Society of Neuroradiology, Boston, 23–27 April, p 290
2.
go back to reference Murayama Y, Vinuela F, Tateshima S, Vinuela F Jr, Akiba Y (2000) Endovascular treatment of experimental aneurysms by use of a combination of liquid embolic agents and protective devices. AJNR Am J Neuroradiol 21(9):1726–1735PubMed Murayama Y, Vinuela F, Tateshima S, Vinuela F Jr, Akiba Y (2000) Endovascular treatment of experimental aneurysms by use of a combination of liquid embolic agents and protective devices. AJNR Am J Neuroradiol 21(9):1726–1735PubMed
3.
go back to reference Mawad ME, Cekirge S, Ciceri E, Saatci I (2002) Endovascular treatment of giant and large intracranial aneurysms by using a combination of stent placement and liquid polymer injection. J Neurosurg 96(3):474–482PubMed Mawad ME, Cekirge S, Ciceri E, Saatci I (2002) Endovascular treatment of giant and large intracranial aneurysms by using a combination of stent placement and liquid polymer injection. J Neurosurg 96(3):474–482PubMed
4.
go back to reference Molyneux AJ, Cekirge S, Saatci I, Gal G (2004) Onyx liquid embolic system in the treatment of cerebral aneurysms: results of a prospective observational study in 20 European centers: CAMEO Study. AJNR Am J Neuroradiol 25:39–51PubMed Molyneux AJ, Cekirge S, Saatci I, Gal G (2004) Onyx liquid embolic system in the treatment of cerebral aneurysms: results of a prospective observational study in 20 European centers: CAMEO Study. AJNR Am J Neuroradiol 25:39–51PubMed
5.
go back to reference Pamuk AG, Saatci I, Cekirge HS, Aypar U (2005) A contribution to the controversy over dimethyl sulfoxide toxicity: anesthesia monitoring results in patients treated with Onyx embolization for intracranial aneurysms. Neuroradiology 47:380–386PubMedCrossRef Pamuk AG, Saatci I, Cekirge HS, Aypar U (2005) A contribution to the controversy over dimethyl sulfoxide toxicity: anesthesia monitoring results in patients treated with Onyx embolization for intracranial aneurysms. Neuroradiology 47:380–386PubMedCrossRef
6.
go back to reference Molyneux A, Kerr R, Stratton I, et al (2002) International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 360:1267–1274PubMedCrossRef Molyneux A, Kerr R, Stratton I, et al (2002) International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 360:1267–1274PubMedCrossRef
7.
go back to reference International Study of Unruptured Intracranial Aneurysms (ISUIA) Investigators (1998) Unruptured intracranial aneurysms—risk of rupture and risks of surgical intervention. N Engl J Med 339:1725–1733CrossRef International Study of Unruptured Intracranial Aneurysms (ISUIA) Investigators (1998) Unruptured intracranial aneurysms—risk of rupture and risks of surgical intervention. N Engl J Med 339:1725–1733CrossRef
8.
go back to reference International Study of Unruptured Intracranial Aneurysms (ISUIA) Investigators (2003) Unruptured intracranial aneurysms: natural history, clinical outcome and risks of surgical and endovascular treatment. Lancet 362 (9378):103–110CrossRef International Study of Unruptured Intracranial Aneurysms (ISUIA) Investigators (2003) Unruptured intracranial aneurysms: natural history, clinical outcome and risks of surgical and endovascular treatment. Lancet 362 (9378):103–110CrossRef
9.
go back to reference Sluzewski M, Menovsky T, van Rooij WJ, Wijnada D (2003) Coiling of very large and giant aneurysm: long-term clinical and serial angiographic results. AJNR Am J Neuroradiol. 24:257–262PubMed Sluzewski M, Menovsky T, van Rooij WJ, Wijnada D (2003) Coiling of very large and giant aneurysm: long-term clinical and serial angiographic results. AJNR Am J Neuroradiol. 24:257–262PubMed
10.
go back to reference Gruber A, Killer M, Bavinzski G, Richling B (1999) Clinical and angiographic results of endosaccular coiling treatment of giant and very large intracranial aneurysms: a 7-year, single-center experience. Neurosurgery 45(4):793–803PubMedCrossRef Gruber A, Killer M, Bavinzski G, Richling B (1999) Clinical and angiographic results of endosaccular coiling treatment of giant and very large intracranial aneurysms: a 7-year, single-center experience. Neurosurgery 45(4):793–803PubMedCrossRef
11.
go back to reference Murayama Y, Nien YL, Duckwiler G, et al (2003) Gugliemi detachable coil embolization of cerebral aneurysms: 11 years experience. J Neurosurg 98:959–966PubMed Murayama Y, Nien YL, Duckwiler G, et al (2003) Gugliemi detachable coil embolization of cerebral aneurysms: 11 years experience. J Neurosurg 98:959–966PubMed
12.
go back to reference Lylyk P, Cohen JE, Ceratto R, Ferrario A, Miranda C (2002) Endovascular reconstruction of intracranial arteries by stent placement and combined techniques. J Neurosurg 97:1306–1313PubMedCrossRef Lylyk P, Cohen JE, Ceratto R, Ferrario A, Miranda C (2002) Endovascular reconstruction of intracranial arteries by stent placement and combined techniques. J Neurosurg 97:1306–1313PubMedCrossRef
13.
go back to reference Han PP, Albuquerque FC, Maccay CI, et al (2003) Percutaneous intracranial stent placement for aneurysms. J Neurosurg 99(1):23–30PubMed Han PP, Albuquerque FC, Maccay CI, et al (2003) Percutaneous intracranial stent placement for aneurysms. J Neurosurg 99(1):23–30PubMed
14.
go back to reference Benitez RP, Silva MT, Klem J, Veznedaroglu E, Rosenwasser RH (2004) Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neurosurgery 54(6):1359–1368PubMedCrossRef Benitez RP, Silva MT, Klem J, Veznedaroglu E, Rosenwasser RH (2004) Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neurosurgery 54(6):1359–1368PubMedCrossRef
15.
go back to reference Fiorella D, Albuquerque FC, Han P, McDougall CG (2004) Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery 54(1):6–17PubMedCrossRef Fiorella D, Albuquerque FC, Han P, McDougall CG (2004) Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery 54(1):6–17PubMedCrossRef
Metadata
Title
Late angiographic and clinical follow-up results of 100 consecutive aneurysms treated with Onyx reconstruction: largest single-center experience
Authors
H. Saruhan Cekirge
Isil Saatci
M. Halil Ozturk
Barbaros Cil
Anil Arat
Michel Mawad
Fikret Ergungor
Deniz Belen
Uygur Er
Sami Turk
Murat Bavbek
Zeki Sekerci
Ethem Beskonakli
Osman E. Ozcan
Tuncalp Ozgen
Publication date
01-02-2006
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 2/2006
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-005-0007-6

Other articles of this Issue 2/2006

Neuroradiology 2/2006 Go to the issue