Skip to main content
Top
Published in: Neuroradiology 7/2003

01-07-2003 | Interventional Neuroradiology

Spiral versus J-shaped coils for neurovascular embolisation—an in-vitro study

Authors: K. Sugiu, K. Tokunaga, S. Mandai, J. B. Martin, B. Jean, D. A. Rüfenacht

Published in: Neuroradiology | Issue 7/2003

Login to get access

Abstract

Our purpose was to compare the characteristics of J-shaped detachable platinum coils with those of spiral coils in in-vitro vascular models. J-shaped coils consist of distal semicircular and proximal straight segments, the latter extending for most of the length of the coil. Spiral coils have a helical shape memory and are thus limited in expansion. In in-vitro silicone vascular models simulating intracranial aneurysms and dural arteriovenous fistulae, we compared J-shaped and spiral coils with regard to ease of delivery, anchoring and folding patterns, and stability in various types of vascular lumen. Delivery and retrieval were comparable. In large and irregular aneurysms and venous sinuses, J-shaped coils could form a more complex basket which conformed to the shape of the vascular cavity. The J-shaped coil was always in contact with the vessel wall. In wide-necked aneurysms, coil protrusion was more frequent with J-shaped coils, while spiral coils tended to stay compact and circular. Arteries were occluded in a shorter segment with spiral coils. J-shaped coils were safe and superior for large and irregular aneurysms or sinuses. Spiral coils were preferable for spherical aneurysms and segmental occlusion of arteries.
Literature
1.
go back to reference Guglielmi G, Viñuela F, Sepetka I, Macellari V (1991) Electrothrombosis of saccular aneurysms via endovascular approach. Part 1: Electrochemical basis, technique, and experimental results. J Neurosurg 75: 1–7PubMed Guglielmi G, Viñuela F, Sepetka I, Macellari V (1991) Electrothrombosis of saccular aneurysms via endovascular approach. Part 1: Electrochemical basis, technique, and experimental results. J Neurosurg 75: 1–7PubMed
2.
go back to reference Guglielmi G, Viñuela F, Dion J, Duckwiler G (1991) Electrothrombosis of saccular aneurysms via endovascular approach. Part 2: Preliminary clinical experience. J Neurosurg 75: 8–14PubMed Guglielmi G, Viñuela F, Dion J, Duckwiler G (1991) Electrothrombosis of saccular aneurysms via endovascular approach. Part 2: Preliminary clinical experience. J Neurosurg 75: 8–14PubMed
3.
go back to reference Cognard C, Pierot L, Boulin A, et al (1997) Intracranial aneurysms: endovascular treatment with mechanical detachable spirals in 60 aneurysms. Radiology 202: 783–792PubMed Cognard C, Pierot L, Boulin A, et al (1997) Intracranial aneurysms: endovascular treatment with mechanical detachable spirals in 60 aneurysms. Radiology 202: 783–792PubMed
4.
go back to reference Cognard C, Weill A, Castaings L, Rey A, Moret J (1998) Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment. Radiology 206: 499–510PubMed Cognard C, Weill A, Castaings L, Rey A, Moret J (1998) Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment. Radiology 206: 499–510PubMed
5.
go back to reference Dawson RC 3rd, Joseph GJ, Owens DS, Barrow DL (1998) Transvenous embolisation as the primary therapy for arteriovenous fistulas of the lateral and sigmoid sinuses. AJNR 19: 571–576 Dawson RC 3rd, Joseph GJ, Owens DS, Barrow DL (1998) Transvenous embolisation as the primary therapy for arteriovenous fistulas of the lateral and sigmoid sinuses. AJNR 19: 571–576
6.
go back to reference Marks MP, Chee H, Liddell RP, Steinberg GK, Panahian N, Lane B (1994) A mechanically detachable coil for the treatment of aneurysms and occlusion of blood vessels. AJNR 15: 821–827 Marks MP, Chee H, Liddell RP, Steinberg GK, Panahian N, Lane B (1994) A mechanically detachable coil for the treatment of aneurysms and occlusion of blood vessels. AJNR 15: 821–827
7.
go back to reference Nichols DA, Brown RD Jr, Thelen KR, Meyer FB, Atkinson JLD, Piepgras DG (1997) Endovascular treatment of ruptured posterior circulation aneurysms using electrolytically detachable coils. J Neurosurg 87: 374–380PubMed Nichols DA, Brown RD Jr, Thelen KR, Meyer FB, Atkinson JLD, Piepgras DG (1997) Endovascular treatment of ruptured posterior circulation aneurysms using electrolytically detachable coils. J Neurosurg 87: 374–380PubMed
8.
go back to reference Roy D, Raymond J (1997) The role of transvenous embolization in the treatment of intracranial dural arteriovenous fistulas. Neurosurgery 40: 1133–1144PubMed Roy D, Raymond J (1997) The role of transvenous embolization in the treatment of intracranial dural arteriovenous fistulas. Neurosurgery 40: 1133–1144PubMed
9.
go back to reference Terada T, Kinoshita Y, Yokote M, et al (1996) Clinical use of mechanical detachable coils for dural arteriovenous fistula. AJNR 17: 1343–1348 Terada T, Kinoshita Y, Yokote M, et al (1996) Clinical use of mechanical detachable coils for dural arteriovenous fistula. AJNR 17: 1343–1348
10.
go back to reference Viñuela F, Duckwiler G, Mawad M (1997) Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 86: 475–482PubMed Viñuela F, Duckwiler G, Mawad M (1997) Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 86: 475–482PubMed
11.
go back to reference Yoshimura S, Hashimoto N, Kazekawa K, Nishi S, Sampei K (1995) Embolization of dural arteriovenous fistulas with interlocking detachable coils. AJNR 16: 322–324 Yoshimura S, Hashimoto N, Kazekawa K, Nishi S, Sampei K (1995) Embolization of dural arteriovenous fistulas with interlocking detachable coils. AJNR 16: 322–324
12.
go back to reference Cloft HJ, Joseph GJ, Tong FC, Goldstein JH, Dion JE (2000) Use of three-dimensional Guglielmi detachable coils in the treatment of wide-necked cerebral aneurysms. AJNR 21: 1312–1314 Cloft HJ, Joseph GJ, Tong FC, Goldstein JH, Dion JE (2000) Use of three-dimensional Guglielmi detachable coils in the treatment of wide-necked cerebral aneurysms. AJNR 21: 1312–1314
13.
go back to reference Gailloud P, Pray JR, Muster M, Piotin M, Fasel JH, Rüfenacht DA (1997) An in vitro anatomic model of the human cerebral arteries with saccular arterial aneurysms. Surg Radiol Anat 19: 119–121PubMed Gailloud P, Pray JR, Muster M, Piotin M, Fasel JH, Rüfenacht DA (1997) An in vitro anatomic model of the human cerebral arteries with saccular arterial aneurysms. Surg Radiol Anat 19: 119–121PubMed
14.
go back to reference Gailloud P, Muster M, Piotin M, et al (1999) In vitro models of intracranial arteriovenous fistulas for the evaluation of new endovascular treatment materials. AJNR 20: 291–295 Gailloud P, Muster M, Piotin M, et al (1999) In vitro models of intracranial arteriovenous fistulas for the evaluation of new endovascular treatment materials. AJNR 20: 291–295
15.
go back to reference Piotin M, Mandai S, Murphy KJ, et al (2000) Dense packing of cerebral aneurysms: an in vitro study with detachable platinum coils. AJNR 21: 757–760 Piotin M, Mandai S, Murphy KJ, et al (2000) Dense packing of cerebral aneurysms: an in vitro study with detachable platinum coils. AJNR 21: 757–760
16.
go back to reference Piotin M, Mandai S, Sugiu K, Gailloud P, Rüfenacht DA (2001) Endovascular treatment of cerebral aneurysms: an in vitro study with detachable platinum coils and tricellulose acetate polymer. Am J Roentgenol 176: 235–239 Piotin M, Mandai S, Sugiu K, Gailloud P, Rüfenacht DA (2001) Endovascular treatment of cerebral aneurysms: an in vitro study with detachable platinum coils and tricellulose acetate polymer. Am J Roentgenol 176: 235–239
17.
go back to reference Moret J, Cognard C, Weill A, Castaings L, Rey A (1997) The "remodeling technique" in the treatment of wide neck intracranial aneurysms. Angiographic results and clinical follow-up in 56 cases. Intervent Neuroradiol 3: 21–35 Moret J, Cognard C, Weill A, Castaings L, Rey A (1997) The "remodeling technique" in the treatment of wide neck intracranial aneurysms. Angiographic results and clinical follow-up in 56 cases. Intervent Neuroradiol 3: 21–35
18.
go back to reference Higashida RT, Smith W, Gress D, et al (1997) Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery. Case report and review of the literature. J Neurosurg 87: 944–949PubMed Higashida RT, Smith W, Gress D, et al (1997) Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery. Case report and review of the literature. J Neurosurg 87: 944–949PubMed
19.
go back to reference Sekhon LH, Morgan MK, Sorby W, Grinnell V (1998) Combined endovascular stent implantation and endosaccular coil placement for the treatment of a wide-necked vertebral artery aneurysm: technical case report. Neurosurgery 43: 380–384 Sekhon LH, Morgan MK, Sorby W, Grinnell V (1998) Combined endovascular stent implantation and endosaccular coil placement for the treatment of a wide-necked vertebral artery aneurysm: technical case report. Neurosurgery 43: 380–384
20.
go back to reference Mericle RA, Lanzino G, Wakhloo AK, Guterman LR, Hopkins LN (1998) Stenting and secondary coiling of intracranial internal carotid artery aneurysm: technical case report. Neurosurgery 43: 1229–1234 Mericle RA, Lanzino G, Wakhloo AK, Guterman LR, Hopkins LN (1998) Stenting and secondary coiling of intracranial internal carotid artery aneurysm: technical case report. Neurosurgery 43: 1229–1234
21.
go back to reference McDougall CG, Halbach VV, Dowd CF, Higashida RT, Larsen DW, Hieshima GB (1998) Causes and management of aneurysmal hemorrhage occurring during embolization with Guglielmi detachable coils. J Neurosurg 89: 87–92PubMed McDougall CG, Halbach VV, Dowd CF, Higashida RT, Larsen DW, Hieshima GB (1998) Causes and management of aneurysmal hemorrhage occurring during embolization with Guglielmi detachable coils. J Neurosurg 89: 87–92PubMed
Metadata
Title
Spiral versus J-shaped coils for neurovascular embolisation—an in-vitro study
Authors
K. Sugiu
K. Tokunaga
S. Mandai
J. B. Martin
B. Jean
D. A. Rüfenacht
Publication date
01-07-2003
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 7/2003
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-003-1012-2

Other articles of this Issue 7/2003

Neuroradiology 7/2003 Go to the issue

Diagnostic Neuroradiology

MRI of medulloblastoma in adults