Published in: Calcified Tissue International 5/2004

01-05-2004

Comparison of Microcomputed Tomographic and Microradiographic Measurements of Cortical Bone Porosity

Authors: D. M. L. Cooper, J. R. Matyas, M. A. Katzenberg, B. Hallgrimsson

Published in: Calcified Tissue International | Issue 5/2004

Login to get access

Abstract

Cortical bone is perforated by a network of canals that have a significant impact upon its material properties. Microcomputed tomography offers the possibility of noninvasively visualizing and quantifying cortical pores in both two and three dimensions. Establishing how two-dimensional (2D) microcomputed tomographic (μCT) analysis compares with conventional methods for analyzing cortical porosity is an important prerequisite for the wider adoption of this technique and the development of three-dimensional (3D) analysis. Therefore, we compared porosity-related parameters from 2D microcomputed tomographic images with those from matching microradiographic sections. Samples from five human femora were scanned at a 10-μm resolution and then sequentially sectioned and microradiographed. An average of eight image pairs were produced from each femur (total, n = 41). The repeatability and comparability of the two techniques was assessed for three parameters; cortical porosity (%), mean pore area (μm2), and pore density (pores/mm2). For repeatability, no significant difference (P > 0.05) was found between the two methods for cortical porosity and mean pore area; however, pore density differed significantly (P < 0.001). For comparability, the bias (± error) between the methods was found to be 0.51% (±0.31%) for cortical porosity and −155 μm2 (±293 μm2) for mean pore area. The bias for pore density was dependent upon measurement size with microcomputed tomographic images having 14% (±9.3%) fewer pores per millimeter squared. The qualitative and quantitative similarities between the two techniques demonstrated the utility of 2D microcomputed tomographic for cortical porosity analysis. However, the relatively poor results for pore density revealed that a higher resolution (<10 μm) is needed to consistently visualize all cortical pores in human bone.
Literature
1.
go back to reference Marotti, G, Zallone, AZ 1980Changes in the vascular network during the formation of Haversian systems.Acta Anat (Basel)10684100 Marotti, G, Zallone, AZ 1980Changes in the vascular network during the formation of Haversian systems.Acta Anat (Basel)10684100
2.
go back to reference Cohen, JWH 1958The three-dimensional anatomy of haversian systems.J Bone Joint Surg Am40419434 Cohen, JWH 1958The three-dimensional anatomy of haversian systems.J Bone Joint Surg Am40419434
3.
go back to reference Stout, SD, Brunsden, BS, Hildebolt, CF, Commean, PK, Smith, KE, et al. 1999Computer-assisted 3D reconstruction of serial sections of cortical bone to determine the 3D structure of osteons.Calcif Tissue Int65280284 Stout, SD, Brunsden, BS, Hildebolt, CF, Commean, PK, Smith, KE,  et al. 1999Computer-assisted 3D reconstruction of serial sections of cortical bone to determine the 3D structure of osteons.Calcif Tissue Int65280284
4.
go back to reference Hert, J, Fiala, P, Petrtyl, M 1994Osteon orientation of the diaphysis of the long bones in man.Bone15269277PubMed Hert, J, Fiala, P, Petrtyl, M 1994Osteon orientation of the diaphysis of the long bones in man.Bone15269277PubMed
5.
go back to reference Petrtyl, M, Hert, J, Fiala, P 1996Spatial organization of the haversian bone in man.J Biomech29161169CrossRefPubMed Petrtyl, M, Hert, J, Fiala, P 1996Spatial organization of the haversian bone in man.J Biomech29161169CrossRefPubMed
6.
go back to reference Currey, JD 1988The effect of porosity and mineral content on the Young’s modulus of elasticity of compact bone.J Biomech21131139 Currey, JD 1988The effect of porosity and mineral content on the Young’s modulus of elasticity of compact bone.J Biomech21131139
7.
go back to reference Martin, RB, Ishida, J 1989The relative effects of collagen fiber orientation, porosity, density, and mineralization on bone strength.J Biomech22419426PubMed Martin, RB, Ishida, J 1989The relative effects of collagen fiber orientation, porosity, density, and mineralization on bone strength.J Biomech22419426PubMed
8.
go back to reference McCalden, RW, McGeough, JA, Barker, MB, Court-Brown, CM 1993Age-related changes in the tensile properties of cortical bone. The relative importance of changes in porosity, mineralization, and microstructure.J Bone Joint Surg Am7511931205PubMed McCalden, RW, McGeough, JA, Barker, MB, Court-Brown, CM 1993Age-related changes in the tensile properties of cortical bone. The relative importance of changes in porosity, mineralization, and microstructure.J Bone Joint Surg Am7511931205PubMed
9.
go back to reference Schaffler, MB, Burr, DB 1988Stiffness of compact bone: effects of porosity and density.J Biomech211316 Schaffler, MB, Burr, DB 1988Stiffness of compact bone: effects of porosity and density.J Biomech211316
10.
go back to reference Barth, RW, Williams, JL, Kaplan, FS 1992Osteon morphometry in females with femoral neck fractures.Clin Orthop.178186 Barth, RW, Williams, JL, Kaplan, FS 1992Osteon morphometry in females with femoral neck fractures.Clin Orthop.178186
11.
go back to reference Bell, KL, Loveridge, N, Reeve, J, Thomas, CD, Feik, SA, et al. 2001Super-osteons (remodeling clusters) in the cortex of the femoral shaft: influence of age and gender.Anat Rec264378386CrossRefPubMed Bell, KL, Loveridge, N, Reeve, J, Thomas, CD, Feik, SA,  et al. 2001Super-osteons (remodeling clusters) in the cortex of the femoral shaft: influence of age and gender.Anat Rec264378386CrossRefPubMed
12.
go back to reference Jordan, GR, Loveridge, N, Bell, KL, Power, J, Rushton, N, et al. 2000Spatial clustering of remodeling osteons in the femoral neck cortex: a cause of weakness in hip fracture?Bone26305313CrossRefPubMed Jordan, GR, Loveridge, N, Bell, KL, Power, J, Rushton, N,  et al. 2000Spatial clustering of remodeling osteons in the femoral neck cortex: a cause of weakness in hip fracture?Bone26305313CrossRefPubMed
13.
go back to reference Yeni, YN, Norman, TL 2000Fracture toughness of human femoral neck: effect of microstructure, composition, and age.Bone26499504CrossRefPubMed Yeni, YN, Norman, TL 2000Fracture toughness of human femoral neck: effect of microstructure, composition, and age.Bone26499504CrossRefPubMed
14.
go back to reference Yeni, YN, Brown, CU, Wang, Z, Norman, TL 1997The influence of bone morphology on fracture toughness of the human femur and tibia.Bone21453459CrossRefPubMed Yeni, YN, Brown, CU, Wang, Z, Norman, TL 1997The influence of bone morphology on fracture toughness of the human femur and tibia.Bone21453459CrossRefPubMed
15.
go back to reference Tappen, NC 1977Three-dimensional studies of resorption spaces and developing osteons.Am J Anat149301332PubMed Tappen, NC 1977Three-dimensional studies of resorption spaces and developing osteons.Am J Anat149301332PubMed
16.
go back to reference Jaworski, ZF, Meunier, P, Frost, HM 1972Observations on two types of resorption cavities in human lamellar cortical bone.Clin Orthop83279285PubMed Jaworski, ZF, Meunier, P, Frost, HM 1972Observations on two types of resorption cavities in human lamellar cortical bone.Clin Orthop83279285PubMed
17.
go back to reference Wachter, NJ, Augat, P, Krischak, GD, Mentzel, M, Kinzl, L, et al. 2001Prediction of cortical bone porosity in vitro by microcomputed tomography.Calcif Tissue Int683842 Wachter, NJ, Augat, P, Krischak, GD, Mentzel, M, Kinzl, L,  et al. 2001Prediction of cortical bone porosity in vitro by microcomputed tomography.Calcif Tissue Int683842
18.
go back to reference Bonse, U, Busch, F, Gunnewig, O, Beckmann, F, Pahl, R, et al. 19943D computed X-ray tomography of human cancellous bone at 8 microns spatial and 10(-4) energy resolution.Bone Miner252538 Bonse, U, Busch, F, Gunnewig, O, Beckmann, F, Pahl, R,  et al. 19943D computed X-ray tomography of human cancellous bone at 8 microns spatial and 10(-4) energy resolution.Bone Miner252538
19.
go back to reference Cooper, DML, Hallgrimsson, B 2001The application of 3D μCT to the analysis of cortical bone porosity.Am J Phys Anthropol11756 Cooper, DML, Hallgrimsson, B 2001The application of 3D μCT to the analysis of cortical bone porosity.Am J Phys Anthropol11756
20.
go back to reference Cooper, DML, Turinsky, AL, Sensen, CW, Hallgrimsson, B 2003Quantitative 3D analysis of the canal network in cortical bone by micro-computed tomography.Anat Rec..in press Cooper, DML, Turinsky, AL, Sensen, CW, Hallgrimsson, B 2003Quantitative 3D analysis of the canal network in cortical bone by micro-computed tomography.Anat Rec..in press
21.
go back to reference Barbier, A, Martel, C, Vernejoul, MC, Tirode, F, Nys, M, et al. 1999The visualization and evaluation of bone architecture in the rat using three-dimensional X-ray microcomputed tomography.J Bone Miner Metab173744CrossRefPubMed Barbier, A, Martel, C, Vernejoul, MC, Tirode, F, Nys, M,  et al. 1999The visualization and evaluation of bone architecture in the rat using three-dimensional X-ray microcomputed tomography.J Bone Miner Metab173744CrossRefPubMed
22.
go back to reference Barou, O, Valentin, D, Vico, L, Tirode, C, Barbier, A, et al. 2002High-resolution three-dimensional micro-computed tomography detects bone loss and changes in trabecular architecture early: comparison with DEXA and bone histomorphometry in a rat model of disuse osteoporosis.Invest Radiol374046CrossRefPubMed Barou, O, Valentin, D, Vico, L, Tirode, C, Barbier, A,  et al. 2002High-resolution three-dimensional micro-computed tomography detects bone loss and changes in trabecular architecture early: comparison with DEXA and bone histomorphometry in a rat model of disuse osteoporosis.Invest Radiol374046CrossRefPubMed
23.
go back to reference Ding, M, Odgaard, A, Hvid, I 1999Accuracy of cancellous bone volume fraction measured by micro-CT scanning.J Biomech32323326CrossRefPubMed Ding, M, Odgaard, A, Hvid, I 1999Accuracy of cancellous bone volume fraction measured by micro-CT scanning.J Biomech32323326CrossRefPubMed
24.
go back to reference Fajardo, RJ, Ryan, TM, Kappelman, J 2002Assessing the accuracy of high-resolution X-ray computed tomography of primate trabecular bone by comparisons with histological sections.Am J Phys Anthropol118110 Fajardo, RJ, Ryan, TM, Kappelman, J 2002Assessing the accuracy of high-resolution X-ray computed tomography of primate trabecular bone by comparisons with histological sections.Am J Phys Anthropol118110
25.
go back to reference Ito, M, Nakamura, T, Matsumoto, T, Tsurusaki, K, Hayashi, K 1998Analysis of trabecular microarchitecture of human iliac bone using microcomputed tomography in patients with hip arthrosis with or without vertebral fracture.Bone23163169CrossRefPubMed Ito, M, Nakamura, T, Matsumoto, T, Tsurusaki, K, Hayashi, K 1998Analysis of trabecular microarchitecture of human iliac bone using microcomputed tomography in patients with hip arthrosis with or without vertebral fracture.Bone23163169CrossRefPubMed
26.
go back to reference Kuhn, JL, Goldstein, SA, Feldkamp, LA, Goulet, RW, Jesion, G 1990Evaluation of a microcomputed tomography system to study trabecular bone structure.J Orthop Res8833842PubMed Kuhn, JL, Goldstein, SA, Feldkamp, LA, Goulet, RW, Jesion, G 1990Evaluation of a microcomputed tomography system to study trabecular bone structure.J Orthop Res8833842PubMed
27.
go back to reference Muller, R, Hahn, M, Vogel, M, Delling, G, Ruegsegger, P 1996Morphometric analysis of noninvasively assessed bone biopsies: comparison of high-resolution computed tomography and histologic sections.Bone18215220CrossRefPubMed Muller, R, Hahn, M, Vogel, M, Delling, G, Ruegsegger, P 1996Morphometric analysis of noninvasively assessed bone biopsies: comparison of high-resolution computed tomography and histologic sections.Bone18215220CrossRefPubMed
28.
go back to reference Muller, R, Campenhout, H, Damme, B, Perre, G, Dequeker, J, et al. 1998Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography.Bone235966CrossRefPubMed Muller, R, Campenhout, H, Damme, B, Perre, G, Dequeker, J,  et al. 1998Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography.Bone235966CrossRefPubMed
29.
go back to reference Uchiyama, T, Tanizawa, T, Muramatsu, H, Endo, N, Takahashi, HE, et al. 1997A morphometric comparison of trabecular structure of human ilium between microcomputed tomography and conventional histomorphometry.Calcif Tissue Int61493498 Uchiyama, T, Tanizawa, T, Muramatsu, H, Endo, N, Takahashi, HE,  et al. 1997A morphometric comparison of trabecular structure of human ilium between microcomputed tomography and conventional histomorphometry.Calcif Tissue Int61493498
30.
go back to reference Altman, DG, Bland, JM 1983Measurement in medicine: the analysis of method comparison studies.Statistician32307317 Altman, DG, Bland, JM 1983Measurement in medicine: the analysis of method comparison studies.Statistician32307317
31.
go back to reference Feldkamp, LA, Goldstein, SA, Parfitt, AM, Jesion, G, Kleerekoper, M 1989The direct examination of three-dimensional bone architecture in vitro by computed tomography.J Bone Miner Res4311PubMed Feldkamp, LA, Goldstein, SA, Parfitt, AM, Jesion, G, Kleerekoper, M 1989The direct examination of three-dimensional bone architecture in vitro by computed tomography.J Bone Miner Res4311PubMed
32.
go back to reference Kothari, M, Keaveny, TM, Lin, JC, Newitt, DC, Genant, HK, et al. 1998Impact of spatial resolution on the prediction of trabecular architecture parameters.Bone22437443CrossRefPubMed Kothari, M, Keaveny, TM, Lin, JC, Newitt, DC, Genant, HK,  et al. 1998Impact of spatial resolution on the prediction of trabecular architecture parameters.Bone22437443CrossRefPubMed
33.
go back to reference Muller, R, Koller, B, Hildebrand, T, Laib, A, Gianolini, S, et al. 1996Resolution dependency of microstructural properties of cancellous bone based on three-dimensional μ tomography.Technol Health Care4113119PubMed Muller, R, Koller, B, Hildebrand, T, Laib, A, Gianolini, S,  et al. 1996Resolution dependency of microstructural properties of cancellous bone based on three-dimensional μ tomography.Technol Health Care4113119PubMed
34.
go back to reference Jowsey, J 1966Studies of Haversian systems in man and some animals.J Anat100857864PubMed Jowsey, J 1966Studies of Haversian systems in man and some animals.J Anat100857864PubMed
35.
go back to reference Engelke, K, Graeff, W, Meiss, L, Hahn, M, Delling, G 1993High spatial resolution imaging of bone mineral using computed microtomography. Comparison with microradiography and undecalcified histologic sections.Invest Radiol28341349PubMed Engelke, K, Graeff, W, Meiss, L, Hahn, M, Delling, G 1993High spatial resolution imaging of bone mineral using computed microtomography. Comparison with microradiography and undecalcified histologic sections.Invest Radiol28341349PubMed
36.
go back to reference Wachter, NJ, Augat, P, Krischak, GD, Sarkar, MR, Mentzel, M, et al. 2001Prediction of strength of cortical bone in vitro by microcomputed tomography.Clin Biomech (Bristol, Avon)16252256 Wachter, NJ, Augat, P, Krischak, GD, Sarkar, MR, Mentzel, M,  et al. 2001Prediction of strength of cortical bone in vitro by microcomputed tomography.Clin Biomech (Bristol, Avon)16252256
37.
go back to reference Uchiyama, T, Tanizawa, T, Ito, A, Endo, N, Takahashi, HE 1999Microstructure of the trabecula and cortex of iliac bone in primary hyperparathyroidism patients determined using histomorphometry and node-strut analysis.J Bone Miner Metab17283288CrossRefPubMed Uchiyama, T, Tanizawa, T, Ito, A, Endo, N, Takahashi, HE 1999Microstructure of the trabecula and cortex of iliac bone in primary hyperparathyroidism patients determined using histomorphometry and node-strut analysis.J Bone Miner Metab17283288CrossRefPubMed
38.
go back to reference Roschger, P, Rinnerthaler, S, Yates, J, Rodan, GA, Fratzl, P, et al. 2001Alendronate increases degree and uniformity of mineralization in cancellous bone and decreases the porosity in cortical bone of osteoporotic women.Bone29185191CrossRefPubMed Roschger, P, Rinnerthaler, S, Yates, J, Rodan, GA, Fratzl, P,  et al. 2001Alendronate increases degree and uniformity of mineralization in cancellous bone and decreases the porosity in cortical bone of osteoporotic women.Bone29185191CrossRefPubMed
Metadata
Title
Comparison of Microcomputed Tomographic and Microradiographic Measurements of Cortical Bone Porosity
Authors
D. M. L. Cooper
J. R. Matyas
M. A. Katzenberg
B. Hallgrimsson
Publication date
01-05-2004
Publisher
Springer-Verlag
Published in
Calcified Tissue International / Issue 5/2004
Print ISSN: 0171-967X
Electronic ISSN: 1432-0827
DOI
https://doi.org/10.1007/s00223-003-0071-z

Other articles of this Issue 5/2004

Calcified Tissue International 5/2004 Go to the issue

OriginalPaper

Announcements

Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine