Assessment of the tibia using ultrasonic guided waves in pubertal girls

Authors: P. Moilanen, P. H. F. Nicholson, T. Kärkkäinen, Q. Wang, J. Timonen, S. Cheng

Published in: Osteoporosis International | Issue 12/2003

Login to get access

Abstract

The purpose of this study was to compare low frequency ultrasonic guided wave measurements with established ultrasound and bone density measurements in terms of their ability to characterize the tibia in pubertal girls. Subjects were 12–14-year-old girls (n=106) who were participating in a calcium and vitamin D intervention study. A prototype low frequency pulse transmission device consisting of a uniaxial scanning mechanism and low frequency transducers orientated perpendicularly to the limb was used to measure two ultrasound velocities in the tibia. The first velocity, V1, was that of the first arriving signal, similar to that measured by existing commercial tibial ultrasound devices. The second velocity, V2, was that of a slower wave propagating at 1,500–2,000 m/s, which has been shown elsewhere to be consistent with the lowest order antisymmetric guided mode in the bone. In addition, commercial ultrasound devices (Omnisense, Sunlight Ltd.; QUS-2, Quidel Corp.) were used to measure the speed of sound (SOS) in the tibia and the radius and attenuation (BUA) in the calcaneus. Cortical bone cross-sectional area (CSA), mineral density (BMD) and cortical thickness (cTh) of the tibia were measured using pQCT, site-matched to the ultrasound measurements. Both V1 and V2 correlated significantly with cortical BMD and with cTh and CSA. On the other hand, tibial SOS correlated with BMD, but not with cTh and CSA. These results indicate that the prototype device using guided waves captures aspects of tibial cortical bone geometry in addition to bone density, thereby potentially offering increased diagnostic information compared to existing tibial ultrasound devices.
Literature
1.
go back to reference National Consensus Development Panel (2002) Osteoporosis prevention, diagnosis, and therapy. JAMA 285:785–795 National Consensus Development Panel (2002) Osteoporosis prevention, diagnosis, and therapy. JAMA 285:785–795
2.
go back to reference Elliott ME, Meek PD, Kanous NL, Schill GR, Weinswig PA, Bohlman JP, Zimpel CL, Jensen BC, Walters DR, Sutter SL, Peterson AN, Peterson RM, Binkley NC (2002) Osteoporosis screening by community pharmacists: use of National Osteoporosis Foundation resources. J Am Pharm Assoc (Wash) 42:101–110, quiz 110–111 Elliott ME, Meek PD, Kanous NL, Schill GR, Weinswig PA, Bohlman JP, Zimpel CL, Jensen BC, Walters DR, Sutter SL, Peterson AN, Peterson RM, Binkley NC (2002) Osteoporosis screening by community pharmacists: use of National Osteoporosis Foundation resources. J Am Pharm Assoc (Wash) 42:101–110, quiz 110–111
3.
go back to reference Kanis JA, Gluer CC (2001) An update on the diagnosis and assessment of osteoporosis with densitometry. Osteoporos Int 11:192–202CrossRef Kanis JA, Gluer CC (2001) An update on the diagnosis and assessment of osteoporosis with densitometry. Osteoporos Int 11:192–202CrossRef
4.
go back to reference Bouxsein ML, Coan BS, Lee SC (1999) Prediction of the strength of the elderly proximal femur by bone mineral density and quantitative ultrasound measurements of the heel and tibia. Bone 25:49–54CrossRefPubMed Bouxsein ML, Coan BS, Lee SC (1999) Prediction of the strength of the elderly proximal femur by bone mineral density and quantitative ultrasound measurements of the heel and tibia. Bone 25:49–54CrossRefPubMed
5.
go back to reference Frost ML, Blake GM, Fogelman I (2001) Quantitative ultrasound and bone mineral density are equally strongly associated with risk factors for osteoporosis. J Bone Miner Res 16:406–416PubMed Frost ML, Blake GM, Fogelman I (2001) Quantitative ultrasound and bone mineral density are equally strongly associated with risk factors for osteoporosis. J Bone Miner Res 16:406–416PubMed
6.
go back to reference Hans D, Dargent-Molina P, Schott AM, Sebert JL, Cormier C, Kotzki PO, Delmas PD, Pouilles JM, Breart G, Meunier PJ (1996) Ultrasonographic heel measurements to predict hip fracture in elderly women: the EPIDOS prospective study. Lancet 348:511–514PubMed Hans D, Dargent-Molina P, Schott AM, Sebert JL, Cormier C, Kotzki PO, Delmas PD, Pouilles JM, Breart G, Meunier PJ (1996) Ultrasonographic heel measurements to predict hip fracture in elderly women: the EPIDOS prospective study. Lancet 348:511–514PubMed
7.
go back to reference Huang C, Ross PD, Yates AJ, Walker RE, Imose K, Emi K, Wasnich RD (1998) Prediction of fracture risk by radiographic absorptiometry and quantitative ultrasound: a prospective study. Calcif Tissue Int 63:380–384CrossRefPubMed Huang C, Ross PD, Yates AJ, Walker RE, Imose K, Emi K, Wasnich RD (1998) Prediction of fracture risk by radiographic absorptiometry and quantitative ultrasound: a prospective study. Calcif Tissue Int 63:380–384CrossRefPubMed
8.
go back to reference Ross P, Huang C, Davis J, Imose K, Yates J, Vogel J, Wasnich R (1995) Predicting vertebral deformity using bone densitometry at various skeletal sites and calcaneus ultrasound. Bone 16:325–332CrossRefPubMed Ross P, Huang C, Davis J, Imose K, Yates J, Vogel J, Wasnich R (1995) Predicting vertebral deformity using bone densitometry at various skeletal sites and calcaneus ultrasound. Bone 16:325–332CrossRefPubMed
9.
go back to reference Camus E, Talmant M, Berger G, Laugier P (2000) Analysis of the axial transmission technique for the assessment of skeletal status. J Acoust Soc Am 108:3058–3065CrossRefPubMed Camus E, Talmant M, Berger G, Laugier P (2000) Analysis of the axial transmission technique for the assessment of skeletal status. J Acoust Soc Am 108:3058–3065CrossRefPubMed
10.
go back to reference Gerlanc M, Haddad D, Hyatt GW, Langloh JT, St Hilaire P (1975) Ultrasonic study of normal and fractured bone. Clin Orthop 111:175–180PubMed Gerlanc M, Haddad D, Hyatt GW, Langloh JT, St Hilaire P (1975) Ultrasonic study of normal and fractured bone. Clin Orthop 111:175–180PubMed
11.
go back to reference Siegel IM, Anast GT, Fields T (1958) The determination of fracture healing by measurement of sound velocity across the fracture site. Surg Gynecol Obstet 107:327–332PubMed Siegel IM, Anast GT, Fields T (1958) The determination of fracture healing by measurement of sound velocity across the fracture site. Surg Gynecol Obstet 107:327–332PubMed
12.
go back to reference Van der Perre G, Lowet G (1996) In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis. Bone 18 [Suppl 1]:29S–35S Van der Perre G, Lowet G (1996) In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis. Bone 18 [Suppl 1]:29S–35S
13.
go back to reference Hans D, Fan B, Fuerst T (1999). Non-heel quantitative ultrasound devices. In: Njeh CF, Hans D, Fuerst T, Gluer CC, Genant HK (eds) Quantitative ultrasound: assessment of osteoporosis and bone status. Martin Dunitz, London, pp 145–162 Hans D, Fan B, Fuerst T (1999). Non-heel quantitative ultrasound devices. In: Njeh CF, Hans D, Fuerst T, Gluer CC, Genant HK (eds) Quantitative ultrasound: assessment of osteoporosis and bone status. Martin Dunitz, London, pp 145–162
14.
go back to reference Foldes AJ, Rimon A, Keinan DD, Popovtzer MM (1995) Quantitative ultrasound of the tibia: a novel approach for assessment of bone status. Bone 17:363–367CrossRefPubMed Foldes AJ, Rimon A, Keinan DD, Popovtzer MM (1995) Quantitative ultrasound of the tibia: a novel approach for assessment of bone status. Bone 17:363–367CrossRefPubMed
15.
go back to reference Lee SC, Coan BS, Bouxsein ML (1997) Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone. Bone 21:119–125CrossRefPubMed Lee SC, Coan BS, Bouxsein ML (1997) Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone. Bone 21:119–125CrossRefPubMed
16.
go back to reference Prevrhal S, Fuerst T, Fan B, Njeh C, Hans D, Uffmann M, Srivastav S, Genant HK (2001) Quantitative ultrasound of the tibia depends on both cortical density and thickness. Osteoporos Int 12:28–34CrossRefPubMed Prevrhal S, Fuerst T, Fan B, Njeh C, Hans D, Uffmann M, Srivastav S, Genant HK (2001) Quantitative ultrasound of the tibia depends on both cortical density and thickness. Osteoporos Int 12:28–34CrossRefPubMed
17.
go back to reference Sievanen H, Cheng S, Ollikainen S, Uusi-Rasi K (2001) Ultrasound velocity and cortical bone characteristics in vivo. Osteoporos Int 12:399–405CrossRefPubMed Sievanen H, Cheng S, Ollikainen S, Uusi-Rasi K (2001) Ultrasound velocity and cortical bone characteristics in vivo. Osteoporos Int 12:399–405CrossRefPubMed
18.
go back to reference Wang SF, Chang CY, Shih C, Teng MM (1997) Measuring tibial cortical bone status by ultrasonic velocity. Zhonghua Yi Xue Za Zhi (Taipei) 60:199–204 Wang SF, Chang CY, Shih C, Teng MM (1997) Measuring tibial cortical bone status by ultrasonic velocity. Zhonghua Yi Xue Za Zhi (Taipei) 60:199–204
19.
go back to reference Stegman MR, Heaney RP, Recker RR (1995) Comparison of speed of sound ultrasound with single photon absorptiometry for determining fracture odds ratios. J Bone Miner Res 10:346–352PubMed Stegman MR, Heaney RP, Recker RR (1995) Comparison of speed of sound ultrasound with single photon absorptiometry for determining fracture odds ratios. J Bone Miner Res 10:346–352PubMed
20.
go back to reference Bossy E, Talmant M, Laugier P (2002) Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: a 2D simulation study. J Acoust Soc Am 112:297–307CrossRefPubMed Bossy E, Talmant M, Laugier P (2002) Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: a 2D simulation study. J Acoust Soc Am 112:297–307CrossRefPubMed
21.
go back to reference Njeh CF, Hans D, Wu C, Kantorovich E, Sister M, Fuerst T, Genant HK (1999) An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen. Med Eng Phys 21:651–659CrossRefPubMed Njeh CF, Hans D, Wu C, Kantorovich E, Sister M, Fuerst T, Genant HK (1999) An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen. Med Eng Phys 21:651–659CrossRefPubMed
22.
go back to reference Graff KF (1991) Wave motion in elastic solids. Dover, New York Graff KF (1991) Wave motion in elastic solids. Dover, New York
23.
go back to reference Viktorov IA (1967) Rayleigh and Lamb waves. Plenum, New York Viktorov IA (1967) Rayleigh and Lamb waves. Plenum, New York
24.
go back to reference Cheeke JDN, Li X, Wang Z (1998) Observation of flexural Lamb waves (A0 mode) on water-filled cylindrical shells. J Acoust Soc Am 104:3678–3680CrossRef Cheeke JDN, Li X, Wang Z (1998) Observation of flexural Lamb waves (A0 mode) on water-filled cylindrical shells. J Acoust Soc Am 104:3678–3680CrossRef
25.
go back to reference Chimenti DE (1997) Guided waves in plates and their use in materials characterization. Appl Mech Rev 50:247–284 Chimenti DE (1997) Guided waves in plates and their use in materials characterization. Appl Mech Rev 50:247–284
26.
go back to reference Chimenti DE, Martin RW (1991) Nondestructive evaluation of composite laminates by leaky Lamb waves. Ultrasonics 29:13CrossRef Chimenti DE, Martin RW (1991) Nondestructive evaluation of composite laminates by leaky Lamb waves. Ultrasonics 29:13CrossRef
27.
go back to reference Karim MR, Mal AK, Bar-Cohen Y (1990) Inversion of leaky Lamb wave data by simplex algorithm. J Acoust Soc Am 88:482–491 Karim MR, Mal AK, Bar-Cohen Y (1990) Inversion of leaky Lamb wave data by simplex algorithm. J Acoust Soc Am 88:482–491
28.
go back to reference Moilanen P, Timonen J, Karkkainen T, Nicholson PHF, Cheng S (2001) Investigation of guided ultrasonic waves in bone phantoms using an axial transmission method. In: Pierce AD (ed) Acoust Soc Am 110:2622 Moilanen P, Timonen J, Karkkainen T, Nicholson PHF, Cheng S (2001) Investigation of guided ultrasonic waves in bone phantoms using an axial transmission method. In: Pierce AD (ed) Acoust Soc Am 110:2622
29.
go back to reference Nicholson PHF, Cheng S, Karkkainen T, Moilanen P, Timonen J (2001) Measurement of guided ultrasonic waves in the human tibia. In: Pierce AD (ed) Acoust Soc Am 110:2622 Nicholson PHF, Cheng S, Karkkainen T, Moilanen P, Timonen J (2001) Measurement of guided ultrasonic waves in the human tibia. In: Pierce AD (ed) Acoust Soc Am 110:2622
30.
go back to reference Nicholson PHF, Moilanen P, Karkkainen T, Timonen J, Cheng S (2002) Guided ultrasonic waves in long bones: modelling, experiment and in vivo application. Physiol Meas 23:755–768 Nicholson PHF, Moilanen P, Karkkainen T, Timonen J, Cheng S (2002) Guided ultrasonic waves in long bones: modelling, experiment and in vivo application. Physiol Meas 23:755–768
31.
go back to reference Cheng S, Tylavsky F, Karkkainen M, Lyytikainen A, Koistinen A, Mahonen A, Halleen J, Vaananen K, Kroger H, Lamberg-Allardt C (2002) Low 25-hydroxy-vitamin D concentrations are associated with lower cortical bone mass in prepubertal Finnish girls. Am J Clin Nutr (in press) Cheng S, Tylavsky F, Karkkainen M, Lyytikainen A, Koistinen A, Mahonen A, Halleen J, Vaananen K, Kroger H, Lamberg-Allardt C (2002) Low 25-hydroxy-vitamin D concentrations are associated with lower cortical bone mass in prepubertal Finnish girls. Am J Clin Nutr (in press)
32.
go back to reference Lowet G, Van der Perre G (1996) Ultrasound velocity measurement in long bones: measurement method and simulation of ultrasound wave propagation. J Biomech 29:1255–1262CrossRefPubMed Lowet G, Van der Perre G (1996) Ultrasound velocity measurement in long bones: measurement method and simulation of ultrasound wave propagation. J Biomech 29:1255–1262CrossRefPubMed
33.
go back to reference Gluer CC, Blake G, Lu Y, Blunt BA, Jergas M, Genant HK (1995) Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques. Osteoporos Int 5:262–270PubMed Gluer CC, Blake G, Lu Y, Blunt BA, Jergas M, Genant HK (1995) Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques. Osteoporos Int 5:262–270PubMed
Metadata
Title
Assessment of the tibia using ultrasonic guided waves in pubertal girls
Authors
P. Moilanen
P. H. F. Nicholson
T. Kärkkäinen
Q. Wang
J. Timonen
S. Cheng
Publication date
01-12-2003
Publisher
Springer-Verlag
Published in
Osteoporosis International / Issue 12/2003
Print ISSN: 0937-941X
Electronic ISSN: 1433-2965
DOI
https://doi.org/10.1007/s00198-003-1528-7

Other articles of this Issue 12/2003

Osteoporosis International 12/2003 Go to the issue